A fully charged liftgate battery does not guarantee enough energy for the last delivery. Repeated hydraulic operations, short journeys and restricted winter charging create cumulative deficits. For liftgate OEMs and vehicle upfitters, sodium battery suitability depends on usable energy at the hardest point on the route, sufficient motor power and replenishment before the next working day.

Kamada Power 12v 100Ah Sodium ion Battery
Why Do Repeated Stops Create a Liftgate Energy Deficit?
A liftgate battery powers hydraulic equipment at stops and may recharge in transit. A fleet case reported by Purkeys describes discharged batteries preventing platforms from rising, requiring road service. This is not a sodium-ion field trial.
A truck may unload several pallets and drive only minutes to the next customer. A full battery can mask undercharging on day one if overnight depot charging is insufficient.
Winter affects both energy supply and demand. Cold batteries may have less accessible energy and lower charging limits. Cold hydraulic fluid can affect operating duration and motor demand, depending on fluid, pump and equipment design. Measure these effects rather than applying a universal winter correction factor.
Long cables and connections can reduce charging voltage. A dedicated liftgate DC-to-DC charger can compensate for this loss, but its presence does not establish sodium-ion compatibility.
How Much Energy Does a Loaded Delivery Route Consume?
Motor nameplate power does not establish daily energy demand. Cargo weight, lifting height, hydraulic efficiency and operating duration influence consumption, as does powered versus gravity-assisted lowering.
Measure voltage and current at the battery terminals throughout representative liftgate operations. The electrical energy consumed by a cycle is:
Cycle energy (Wh) = integral of V(t) × I(t) over time ÷ 3,600
Voltage is measured in volts, current in amperes and time in seconds.
Log loaded lifts, unloaded movements, returns and standby separately, including unusually demanding stops. Do not count returns twice if already included in a complete cycle.
The following hypothetical route illustrates the calculation. For scale, the MAXON GPC X1-LD/LDF operator handbook, page 5 cites 150A at 12V and recommends an 88Ah battery for its 600 kg capacity example. At 12V and 150A, 36 seconds of equivalent powered operation consumes 18 Wh. This is an order-of-magnitude illustration, not a measured cycle or a claim that the current remains constant.
| Route energy parameter | Illustrative value |
|---|
| Complete lift-and-return cycles | 30 |
| Average energy per cycle | 18 Wh |
| Liftgate operating energy | 540 Wh |
| Controller and standby consumption | 60 Wh |
| Total battery-terminal energy demand | 600 Wh |
| Effective vehicle charging time | 2 hours |
| Average accepted charging power | 120 W |
| Energy supplied to battery terminals | 240 Wh |
| Daily terminal-energy deficit | 360 Wh |
The vehicle restores only 40% of the energy consumed. The remaining 360 Wh must be drawn from existing battery storage, with further allowance for internal battery losses. Five identical working days without additional charging would produce a cumulative terminal-energy deficit of 1,800 Wh.
Energy sufficiency is not motor compatibility. A Kamada Power 12V/100Ah engineering reference lists 100A maximum continuous discharge and a 150A pulse lasting less than 3 milliseconds. Those figures do not qualify a single pack for a 150A lift lasting several seconds. Check the motor current-duration profile, including starting inrush, loaded restarts and repeated-cycle thermal limits, against approved pack limits at the expected temperature. Verify minimum motor-terminal voltage. Excessive cable drop or a battery management system (BMS) disconnect can interrupt operation even when stored energy remains. The 8V protective cutoff in that reference is not an acceptable motor operating voltage by default.
Can Winter Driving Time Replace the Energy Used at Each Stop?
A DC-to-DC charger rated at 40A does not necessarily deliver 40A to the liftgate battery throughout a winter journey. Accepted charging current depends on the vehicle electrical supply, the charger’s output characteristics, the battery’s temperature and state of charge (SOC), and the limits specified for the finished battery.
The energy supplied during each driving interval is:
Charging energy (Wh) = integral of Vcharge(t) × Iaccepted(t) over time ÷ 3,600
Use the current actually accepted by the battery, not the charger’s maximum nameplate rating. Where auxiliary loads remain active during driving, account for them separately or use net battery-terminal power consistently.
Consider a hypothetical charging voltage of 13.5V and a 15-minute driving interval. At 10A, the battery receives 33.75 Wh. At 20A, it receives 67.5 Wh. At 40A, it receives 135 Wh. These values assume constant voltage and current, and exclude internal storage losses. They are not charging-current specifications for a Kamada Power battery.
For context, the 12V/100Ah engineering reference lists 10A from −20°C to −10°C and 20A from −10°C to 0°C. These limits are revision-specific. The reference describes standard CC/CV charging at 0–45°C; confirm subzero voltage, current, termination, temperature boundaries and BMS behavior separately. A larger charger cannot override those limits. Nor should routine current regulation depend on BMS protective shutdowns. The Purkeys Direct installation guide describes raising charging voltage in cold weather. An existing lead-acid temperature-compensation profile must therefore be checked against the sodium-ion pack’s approved voltage and current limits; the reference maximum of 15.6V is a ceiling, not a universal charging setpoint.
A pack approved for subzero charging may offer an alternative to systems that restrict charging below freezing, provided motor-current and voltage requirements are met. Cell research alone cannot establish finished-pack charging limits or winter energy recovery.
Battery temperature, not ambient temperature, determines the applicable charging limit. A trailer-mounted pack may remain cold after the engine warms, restricting replenishment throughout short journeys.
A five-minute driving interval at 120W supplies only 10 Wh. If the preceding liftgate operation consumed 18 Wh, another 8 Wh of terminal-energy deficit is carried forward, even before storage losses. Longer driving intervals later in the day may recover that deficit, but they cannot help a delivery that occurs before those intervals.
Where Does the Route Reach Its Lowest Energy Reserve?
Routes with identical daily consumption, charging input and final reserve can have different minimum energy requirements because delivery and charging events occur in different orders.
Return to the hypothetical route consuming 600 Wh and receiving 240 Wh of charging energy. Assume it starts with 800 Wh of accessible stored energy. Divide the demand into three delivery blocks of 200 Wh, including allocated standby consumption, and the charging supply into two blocks of 120 Wh. For this simplified comparison, assume charging energy is fully recoverable, temperature is constant, and neither charging block encounters a full battery.
| Operating stage | Route A — Distributed deliveries | Route B — Concentrated deliveries |
|---|
| Departure | 800 Wh | 800 Wh |
| First delivery block | 600 Wh | 600 Wh |
| Next event | 720 Wh (charge) | 400 Wh (delivery) |
| Next event | 520 Wh (delivery) | 520 Wh (charge) |
| Next charging block | 640 Wh | 640 Wh |
| Final delivery block | 440 Wh | 440 Wh |
| Minimum remaining energy | 440 Wh | 400 Wh |

Both routes finish with 440 Wh. Route B, however, reaches its lowest reserve before the first substantial charging opportunity. With an assumed minimum operating reserve of 420 Wh, Route A passes the energy requirement while Route B fails it.
For the simplified constant-temperature, loss-free model:
Required starting usable energy ≥ maximum cumulative route energy deficit + required operating reserve.
Under the illustrative conditions, the maximum cumulative deficit is 360 Wh for Route A and 400 Wh for Route B. Maintaining a 420 Wh reserve requires at least 780 Wh and 820 Wh of starting usable energy, respectively. The 420 Wh reserve is illustrative, not a universal recommendation. Set the actual reserve from essential remaining lift cycles, unexpected deliveries, aging and cold-weather uncertainty; verify loaded voltage independently.
In practice, track accessible energy after each delivery and charging segment. Cap replenishment at available storage headroom and account for internal losses. Reassess accessible energy as operating temperature changes.
When Is a Charging-System Upgrade More Effective Than Another Battery?
For OEMs evaluating a 12V 100Ah sodium-ion battery, manufacturer-approved parallel configurations provide a potential way to increase storage. On an illustrative 12V nominal design basis, 1P, 2P, 3P and 4P represent 100Ah, 200Ah, 300Ah and 400Ah, or 1,200Wh, 2,400Wh, 3,600Wh and 4,800Wh respectively. These are nominal calculations, not measured usable energy. The linked catalog lists a 12.8V model; the 12V engineering reference used here must not be treated as the same revision without confirmation. Obtain the exact SKU and approved limits before design release.

If one pack cannot supply the concentrated route’s required 820 Wh, evaluate a larger approved configuration. Determine accessible energy at the expected temperature and equipment operating voltage, not from nominal capacity alone.
With sufficient overnight depot charging, a larger bank can cover concentrated deliveries without a higher-rated vehicle charger.
Without overnight charging, additional capacity only delays the recurring 360 Wh daily deficit.
For the example route, balancing 600 Wh of daily terminal demand over two hours of effective charging requires an average of at least 300W. At an illustrative charging voltage of 13.5V, that is approximately 22.2A of accepted current, before accounting for internal storage losses. At 13.5V, a single pack limited to 10A or 20A receives only 270Wh or 540Wh in two hours, leaving 330Wh or 60Wh of deficit before losses. Consider approved parallel charging capacity, longer charging intervals or depot charging; a larger charger alone cannot overcome pack limits.
The procurement decision follows four conditions:
- Temporary energy shortage: Increase usable storage or move an available charging opportunity ahead of the demanding delivery cluster.
- Recurring undercharging: Improve compatible replenishment through vehicle or depot charging.
- Both conditions: Compare the combined storage and charging requirements using the chronological route ledger.
- Motor or voltage incompatibility: Reject direct substitution and consider a separately engineered OEM platform.
For a 150A operating load, ideal sharing across 1P, 2P, 3P and 4P gives 150A, 75A, 50A and 37.5A per pack, respectively. With the reference 100A continuous limit, 1P fails this initial sustained-current screen; 2P–4P merit evaluation, not automatic approval. A 2P bank could leave the remaining pack carrying 150A if one branch disconnects. Actual sharing, cold-temperature limits, branch protection and safe shutdown behavior must be established. If approved parallel arrangements cannot meet motor or charging requirements, evaluate a high-power OEM pack rather than bypassing protection. Retrofits must meet vehicle and liftgate manufacturers electrical requirements and approval conditions.

FAQ
Can a 100Ah pack drive a liftgate?
Potentially. A finished 100Ah sodium-ion battery must satisfy the hydraulic motor’s current-duration requirements, loaded voltage limits and maximum cumulative route energy deficit. If one pack is insufficient, manufacturer-approved parallel configurations or an independently engineered OEM battery may be considered. Nominal capacity does not establish direct replacement compatibility.
Will two batteries fix short driving intervals?
Two approved parallel batteries can provide more operating reserve between charging opportunities. They do not necessarily increase the energy restored during short journeys. If daily consumption continues to exceed replenishment, a compatible charging upgrade or additional depot charging is still necessary.
Does a DC/DC charger need a sodium-ion profile?
The charger must meet the selected battery’s voltage, current, temperature and charging termination requirements. A dedicated sodium-ion profile may be appropriate, but its name does not establish compatibility. Existing lead-acid or lithium-ion settings should only be used if their actual behavior is approved for the specific battery and equipment configuration.
Conclusion
Sodium-ion batteries are a candidate for winter truck liftgate systems when their usable energy, motor current capability, operating voltage and temperature-dependent charging limits match the delivery duty cycle. The maximum cumulative route deficit determines the necessary starting energy, while the daily replenishment balance determines whether the system can sustain consecutive working days. For standard 12V 100Ah sodium-ion battery, approved parallel configurations or potential custom liftgate battery designs, contact Kamada Power with your longest winter delivery route, hydraulic motor current profile, vehicle charging specifications and expected battery temperature range to discuss an application-specific battery and charging architecture.