{"id":5167,"date":"2026-05-09T09:54:07","date_gmt":"2026-05-09T09:54:07","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5167"},"modified":"2026-05-09T09:54:09","modified_gmt":"2026-05-09T09:54:09","slug":"sodium-ion-vs-agm-batteries-is-your-ups-ready-for-the-sodium-revolution","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sv\/news\/sodium-ion-vs-agm-batteries-is-your-ups-ready-for-the-sodium-revolution\/","title":{"rendered":"Sodium-ion vs. AGM Batteries: Is Your UPS Ready for the Sodium Revolution?"},"content":{"rendered":"<p>AGM (Absorbent Glass Mat) batteries have long been the industry standard for standby power, but their sensitivity to thermal stress and float-charging degradation is forcing a global shift. As Sodium-ion (Na-ion) emerges as a high-performance alternative, the real hurdle for procurement officers and industrial engineers in the US and Europe isn&#8217;t just cost\u2014it\u2019s technical integration. Can <strong><a href=\"https:\/\/www.kmdpower.com\/sv\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natriumjonbatteri<\/a><\/strong> truly replace AGM within your existing UPS infrastructure without compromising safety or reliability?<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-12v-100ah-sodium-ion-battery-main-image-002.jpg\" alt=\"\" class=\"wp-image-1181\"\/><\/figure><p class=\"has-text-align-center\"><strong><a href=\"https:\/\/www.kmdpower.com\/sv\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100Ah natriumjonbatteri<\/a><\/strong><\/p><h2 class=\"wp-block-heading\" id=\"sodium-ion-vs-agm-the-battle-for-the-future-of-standby-power\">Natriumjonbatteri vs. AGM: Kampen om framtidens standby-str\u00f6m<\/h2><p>The energy landscape is shifting away from the &#8220;Lead-Acid Trap.&#8221; While Lithium-ion (LFP) has dominated the EV market, Sodium-ion is carving out a dynamic niche in stationary storage. Why? Because sodium is geologically abundant, immune to the price volatility of lithium, and\u2014from a chemical standpoint\u2014significantly more robust in high-demand industrial scenarios.<\/p><p>V\u00e5r erfarenhet av att arbeta med datacenter och telekomleverant\u00f6rer visar att \u00f6verg\u00e5ngen oftast handlar om \"Triad of Reliability\": Cykellivsl\u00e4ngd, temperaturt\u00e5lighet och enkel integrering. H\u00e4r \u00e4r en teknisk j\u00e4mf\u00f6relse baserad p\u00e5 nuvarande natriumjonbatterier av kommersiell kvalitet (Layered Oxide) j\u00e4mf\u00f6rt med premium AGM-batterier f\u00f6r industrin:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Funktion<\/th><th>AGM (bly-syra)<\/th><th>Natriumjon (Na-jon)<\/th><th>Informationsvinst \/ expertutl\u00e5tande<\/th><\/tr><\/thead><tbody><tr><td><strong>Livscykel (80% DoD)<\/strong><\/td><td>300 - 600 cykler<\/td><td>4.000+ cykler<\/td><td>Na-joncykelns livsl\u00e4ngd beror p\u00e5 katodtypen (Layered Oxide vs Prussian Blue).<\/td><\/tr><tr><td><strong>Laddningstemperaturintervall<\/strong><\/td><td>0\u00b0C till 40\u00b0C (b\u00e4st vid 25\u00b0C)<\/td><td>-10\u00b0C till 70\u00b0C<\/td><td>Na-jon kan laddas vid l\u00e4gre temperaturer utan risk f\u00f6r litiumpl\u00e4tering.<\/td><\/tr><tr><td><strong>Omr\u00e5de f\u00f6r utloppstemperatur<\/strong><\/td><td>-15\u00b0C till 50\u00b0C<\/td><td>-40\u00b0C till 70\u00b0C<\/td><td>Na-jon bibeh\u00e5ller &gt;80% kapacitet vid frystemperaturer.<\/td><\/tr><tr><td><strong>Laddningsl\u00e4ge<\/strong><\/td><td>3-stegs flott\u00f6r<\/td><td>CC\/CV (konstant str\u00f6m\/sp\u00e4nning)<\/td><td>Na-ion kr\u00e4ver en BMS-kontrollerad avslutning.<\/td><\/tr><tr><td><strong>Sj\u00e4lvurladdning<\/strong><\/td><td>3% - 5% \/ m\u00e5nad<\/td><td>&lt;1% - 2% \/ m\u00e5nad<\/td><td>AGM:s \"hyll\u00e5ldring\" leder till irreversibel sulfatering.<\/td><\/tr><tr><td><strong>Energidensitet<\/strong><\/td><td>30 - 50 Wh\/kg<\/td><td>100 - 150 Wh\/kg<\/td><td>3x viktreduktion s\u00e4nker avsev\u00e4rt kostnaderna f\u00f6r lastning av golv.<\/td><\/tr><tr><td><strong>S\u00e4kerhetsstandard<\/strong><\/td><td>UL 1989<\/td><td>UL 1973 \/ UL 9540A<\/td><td>Na-jon testas f\u00f6r \"icke-spridning\" i brandscenarier.<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"wp-block-heading\" id=\"the-crucial-difference-in-charge-modes-cccv-vs-float\">Den avg\u00f6rande skillnaden mellan olika laddningsl\u00e4gen: CCCV j\u00e4mf\u00f6rt med flott\u00f6r<\/h2><p>Det enskilt st\u00f6rsta tekniska hindret f\u00f6r att ers\u00e4tta AGM med natriumjon \u00e4r den grundl\u00e4ggande skillnaden i hur dessa kemier tar emot elektricitet.<\/p><p><strong>AGM:s komfortzon: Det st\u00e4ndiga droppet<\/strong>&nbsp;Bly-syra-batterier kr\u00e4ver&nbsp;<strong>Laddning av flott\u00f6r<\/strong>. T\u00e4nk p\u00e5 det som en konstant \"dropp\" av energi med l\u00e5gt tryck som h\u00e5ller batteriet p\u00e5 100%. Eftersom AGM-batterier har h\u00f6g intern sj\u00e4lvurladdning \u00e4r denna underh\u00e5llsladdning obligatorisk f\u00f6r att f\u00f6rhindra&nbsp;<strong>sulfatering<\/strong>-uppbyggnad av blysulfatkristaller som h\u00e4rdar och d\u00f6dar batteriet.<\/p><p><strong>Natriumjonens logik: Den trycksatta tanken<\/strong>&nbsp;Natriumjon, liksom dess kusin litiumjon, drivs av en&nbsp;<strong>CC\/CV (konstant str\u00f6m\/konstant sp\u00e4nning)<\/strong>&nbsp;protokoll. Den tar snabbt emot en stor m\u00e4ngd str\u00f6m, n\u00e5r ett sp\u00e4nningstak och sedan avtar str\u00f6mmen tills batteriet \u00e4r \"m\u00e4ttat\".<\/p><p><strong>Konflikten: H\u00f6g SOC-stress<\/strong>&nbsp;Det \u00e4r h\u00e4r det blir knepigt f\u00f6r UPS-k\u00f6pare. Om du s\u00e4tter ett natriumjonbatteri p\u00e5 en traditionell AGM-flott\u00f6rladdare kommer laddaren att f\u00f6rs\u00f6ka h\u00e5lla en konstant sp\u00e4nning i det o\u00e4ndliga. Ett v\u00e4ldesignat batterihanteringssystem (BMS) skyddar cellerna,&nbsp;<strong>L\u00e5ngvarig h\u00f6g laddningsstatus (SOC) i kombination med konstant sp\u00e4nningsp\u00e5frestning<\/strong>&nbsp;kan leda till elektrolytoxidation och f\u00f6rtjockning av SEI-skiktet (Solid Electrolyte Interphase). Till skillnad fr\u00e5n AGM vill natriumjonbatterier inte \"petas p\u00e5\" hela tiden n\u00e4r de v\u00e4l \u00e4r fulla; de f\u00f6redrar att sitta stilla tills de beh\u00f6ver anv\u00e4ndas.<\/p><h2 class=\"wp-block-heading\" id=\"float-voltage-compatibility-the-drop-in-myth\">Kompatibilitet med flott\u00f6rsp\u00e4nning: Myten om \"drop-in\"-system<\/h2><p>I v\u00e5rt konsultarbete ser vi ofta marknadsf\u00f6ringsmaterial som p\u00e5st\u00e5r \"100% Drop-in Replacement\". Som ingenj\u00f6r r\u00e5der jag dig att f\u00f6rh\u00e5lla dig skeptisk till detta.<\/p><p><strong>Problemet med sp\u00e4nningsf\u00f6nstret<\/strong>\u00a0Ett standard 12V AGM-batteri ligger vanligtvis mellan\u00a0<strong>13,5 V och 13,8 V<\/strong>. <strong><a href=\"https:\/\/www.kmdpower.com\/sv\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natriumjonbatterier<\/a><\/strong> have a much wider and more linear voltage curve (typically 2.0V to 4.0V per cell). If your UPS firmware is hard-coded for AGM, it might &#8220;think&#8221; the Sodium-ion battery is empty when it is actually at 30% capacity, or it might never trigger the &#8220;Charge Complete&#8221; signal, causing the BMS to trip an Over-Voltage Protection (OVP) alarm.<\/p><p><strong>Kommunikationsgapet: sluten slinga kontra \u00f6ppen slinga<\/strong>&nbsp;I ett modernt natriumjonst\u00e4ll m\u00e5ste BMS prata med UPS:en.<\/p><ul class=\"wp-block-list\"><li><strong>\u00d6ppen slinga:<\/strong>\u00a0UPS:en levererar bara str\u00f6m baserat p\u00e5 sp\u00e4nning. (Riskabelt f\u00f6r natriumjon).<\/li>\n\n<li><strong>Slutet kretslopp:<\/strong>\u00a0UPS:en tar emot data via\u00a0<strong>Modbus TCP\/IP, CANbus eller SNMP<\/strong>\u00a0fr\u00e5n BMS. Batteriet s\u00e4ger till UPS:en: \"Jag \u00e4r full, sluta ladda.\"<\/li>\n\n<li><strong>Expertinsikt:<\/strong>\u00a0Om du \u00e4r upphandlare ska du alltid fr\u00e5ga:\u00a0<em>\"St\u00f6der detta batteribaserade BMS kommunikation i sluten krets med mitt specifika UPS-varum\u00e4rke (t.ex. Vertiv, Eaton eller APC)?\"<\/em><\/li><\/ul><h2 class=\"wp-block-heading\" id=\"standby-self-discharge-and-the-0v-reality\">Sj\u00e4lvurladdning i standby och 0V-verkligheten<\/h2><p>Om ett batteri ligger i ett avl\u00e4gset telekomsk\u00e5p i sex m\u00e5nader, kommer det d\u00e5 fortfarande att fungera?<\/p><p>AGM-batterier \u00e4r \u00f6k\u00e4nda f\u00f6r att \"\u00e5ldras p\u00e5 hyllan\". Om de inte st\u00e5r p\u00e5 en laddare f\u00f6rlorar de tillr\u00e4ckligt med energi f\u00f6r att b\u00f6rja sulfatera inom n\u00e5gra m\u00e5nader. I avl\u00e4gsna telekombasstationer - s\u00e4rskilt i omr\u00e5den utan eln\u00e4t eller med instabilt eln\u00e4t - \u00e4r detta en d\u00f6dsdom f\u00f6r blybatterier.<\/p><p><strong>Natriumjonens hemliga vapen: 0V-transporter<\/strong>&nbsp;En av de mest imponerande tekniska f\u00f6rdelarna med natriumjon \u00e4r m\u00f6jligheten att anv\u00e4nda&nbsp;<strong>Str\u00f6mavtagare av aluminium<\/strong>&nbsp;p\u00e5 b\u00e5de anoden och katoden. I litiumjon l\u00f6ses kopparkollektorn upp vid l\u00e5ga sp\u00e4nningar. Natriumjon kan vara&nbsp;<strong>urladdad till 0,0 V f\u00f6r s\u00e4ker flygfrakt och l\u00e5ngtidsf\u00f6rvaring<\/strong>&nbsp;utan att skada kemin.<\/p><ul class=\"wp-block-list\"><li><strong>R\u00e4ttelse f\u00f6r ingenj\u00f6rer:<\/strong>\u00a0Medan Na-ion kan vara\u00a0<em>lagras<\/em>\u00a0vid 0V, men operativa system kr\u00e4ver fortfarande en\u00a0<strong>Avst\u00e4ngning vid l\u00e5g sp\u00e4nning (~2,0V)<\/strong>. L\u00e5t inte UPS:en t\u00f6mma ett batteri till 0 V i f\u00e4lt, eftersom BMS kr\u00e4ver en l\u00e4gsta sp\u00e4nning f\u00f6r att h\u00e5lla str\u00f6mf\u00f6rs\u00f6rjningen och \"v\u00e4cka\" systemet.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"safety-and-thermal-runaway-moving-beyond-the-fear\">S\u00e4kerhet och termisk rusning: Att g\u00e5 bortom r\u00e4dslan<\/h2><p>F\u00f6r fastighetsf\u00f6rvaltare \u00e4r s\u00e4kerheten \"elefanten i rummet\". AGM-batterier \u00e4r relativt s\u00e4kra men kan avge v\u00e4tgas vid \u00f6verladdning (vilket leder till \"termisk rusning\").<\/p><p>Natriumjonbatterier \u00e4r i sig mer stabila \u00e4n litium NMC-batterier. P\u00e5 grund av h\u00f6gre inre motst\u00e5nd vid kortslutning och h\u00f6gre termisk stabilitet hos elektrolyten \u00e4r det mycket mindre sannolikt att natriumjonbatterier drabbas av katastrofal brandspridning.<\/p><ul class=\"wp-block-list\"><li><strong>UL 9540A-faktorn:<\/strong>\u00a0N\u00e4r du upphandlar USA-baserade datacenter ska du leta efter\u00a0<strong>UL 9540A testresultat<\/strong>. Detta test avg\u00f6r om en brand i en batterimodul kommer att sprida sig till n\u00e4sta. Natriumjonenheter av h\u00f6g kvalitet \u00e4r konstruerade f\u00f6r \"icke-spridning\", vilket inneb\u00e4r att \u00e4ven om en cell g\u00e5r s\u00f6nder f\u00f6rblir racket s\u00e4kert. Detta ger betydligt l\u00e4gre f\u00f6rs\u00e4kringspremier och l\u00e4gre krav p\u00e5 efterlevnad av NFPA 855.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"suitability-for-ups-standby-applications\">L\u00e4mplighet f\u00f6r UPS- och standby-applikationer<\/h2><p>L\u00e5t oss titta p\u00e5 avv\u00e4gningen \"utrymme kontra effekt\". I ett serverrum med h\u00f6g densitet \u00e4r golvutrymmet en viktig tillg\u00e5ng.<\/p><ol class=\"wp-block-list\"><li><strong>Golvbelastning och vikt:<\/strong>\u00a0Natriumjonbatterier \u00e4r betydligt l\u00e4ttare \u00e4n AGM-batterier. En AGM-bank f\u00f6r en UPS p\u00e5 100 kW kan v\u00e4ga flera ton och kr\u00e4ver ett golv av armerad betong. Natriumjon ger samma drifttid vid\u00a0<strong>en tredjedel av vikten<\/strong>.<\/li>\n\n<li><strong>Dynamiskt avgiftsgodk\u00e4nnande (DCA):<\/strong>\u00a0Natriumjonbatterier kan laddas mycket snabbare \u00e4n AGM-batterier. Efter ett str\u00f6mavbrott kan det ta 10-24 timmar f\u00f6r ett AGM-batteri att n\u00e5 100% igen. Natriumjonbatterier kan ofta n\u00e5 80% SOC p\u00e5 mindre \u00e4n en timme, vilket g\u00f6r dem helt \u00f6verl\u00e4gsna f\u00f6r platser med frekventa \"mikroavbrott\" eller instabila eln\u00e4t.<\/li>\n\n<li><strong>Total \u00e4gandekostnad (TCO):<\/strong>\u00a0Att g\u00e5 fr\u00e5n CAPEX till OPEX. Ett AGM-system kan kosta $10.000 p\u00e5 f\u00f6rhand men m\u00e5ste bytas ut vart 3-4:e \u00e5r. Ett natriumjonsystem kan kosta $15.000 men h\u00e5ller i 8-10 \u00e5r. N\u00e4r du r\u00e4knar in\u00a0<strong>Kostnader f\u00f6r \"Truck Roll\"<\/strong>\u00a0(arbete, bortskaffande av bly och installation) betalar sig Sodium-ion normalt redan under det femte \u00e5ret.<\/li><\/ol><h2 class=\"wp-block-heading\" id=\"should-you-switch-today-\">Ska du byta idag?<\/h2><p>\"Natriumrevolutionen\" \u00e4r inte bara en hype - det \u00e4r ett svar p\u00e5 de tekniska begr\u00e4nsningarna med bly-syra och kostnadsbegr\u00e4nsningarna med litium.<\/p><ul class=\"wp-block-list\"><li><strong>H\u00e5ll dig till \u00e5rsst\u00e4mman om:<\/strong>\u00a0Du har en liten, \u00e4ldre UPS utan m\u00f6jlighet att justera den inbyggda programvaran, din milj\u00f6 \u00e4r strikt klimatkontrollerad och du har en mycket begr\u00e4nsad initial budget.<\/li>\n\n<li><strong>Switch to Sodium-ion if:<\/strong>\u00a0Du bygger ett nytt datacenter, arbetar i milj\u00f6er med h\u00f6ga temperaturer (Mellan\u00f6stern, s\u00f6dra USA, Afrika) eller har att g\u00f6ra med frekventa str\u00f6mavbrott som skulle \"cykeld\u00f6da\" ett AGM-batteri.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"-conclusion-\"><strong>Slutsats<\/strong><\/h2><p><strong><a href=\"https:\/\/www.kmdpower.com\/sv\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natriumjonbatteri<\/a><\/strong> \u00e4r det \u00f6verl\u00e4gsna valet f\u00f6r modern standby-kraft, med exceptionell termisk stabilitet och en livsl\u00e4ngd som \u00f6vertr\u00e4ffar traditionell AGM. Det \u00e4r dock inte en \"blind\" plug-and-play-l\u00f6sning. F\u00f6r att lyckas kr\u00e4vs en strategi p\u00e5 systemniv\u00e5: matchning av UPS-laddningsfirmware till natriumjonsp\u00e4nningskurvan och s\u00e4kerst\u00e4llande av robust BMS-kommunikation. Genom att \u00f6verg\u00e5 till en konstruerad natriumjonl\u00f6sning byter du ut batteribyten med stort underh\u00e5llsbehov mot en tillf\u00f6rlitlig, l\u00e5ngsiktig backupstrategi som s\u00e4nker din TCO och f\u00f6rb\u00e4ttrar anl\u00e4ggningens ESG-betyg. <strong><a href=\"https:\/\/www.kmdpower.com\/sv\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kontakta Kamada Power<\/a><\/strong> our engineering team to audit your UPS compatibility for Sodium-ion today.<\/p><h2 class=\"wp-block-heading\" id=\"-faq-\"><strong>VANLIGA FR\u00c5GOR<\/strong><\/h2><h3 class=\"wp-block-heading\" id=\"-can-i-mix-agm-and-sodium-ion-batteries-in-the-same-string-or-rack-\"><strong>Kan jag blanda AGM- och natriumjonbatterier i samma str\u00e4ng eller rack?<\/strong><\/h3><p>Nej, absolut inte. De har helt olika inre resistans och sp\u00e4nningskurvor. Om du blandar dem kommer batterierna att \"sl\u00e5ss\" mot varandra, vilket kan leda till brandrisk eller omedelbart systemfel.<\/p><h3 class=\"wp-block-heading\" id=\"-is-sodium-ion-non-flammable-\"><strong>Is Sodium-ion &#8220;non-flammable&#8221;?<\/strong><\/h3><p>No battery is inherently non-flammable, but Sodium-ion has a significantly higher thermal stability threshold than Lithium NMC. It is much less likely to catch fire under physical stress, making it the preferred choice for high-occupancy buildings.<\/p><h3 class=\"wp-block-heading\" id=\"-what-if-my-ups-doesn-t-have-a-specific-sodium-setting-\"><strong>What if my UPS doesn&#8217;t have a specific &#8220;Sodium&#8221; setting?<\/strong><\/h3><p><strong>A:<\/strong>&nbsp;Most modern UPS units have a &#8220;User Defined&#8221; or &#8220;Custom Lithium&#8221; setting. You can manually input the Bulk and Float voltages provided by the Sodium-ion manufacturer. If your UPS only has a fixed &#8220;Lead-Acid&#8221; switch, you must consult an integrator before upgrading.<\/p><h3 class=\"wp-block-heading\" id=\"-how-does-the-self-discharge-rate-affect-my-black-start-capability-\"><strong>Hur p\u00e5verkar sj\u00e4lvurladdningshastigheten min \"Black Start\"-f\u00f6rm\u00e5ga?<\/strong><\/h3><p>Eftersom natriumjonbatterier f\u00f6rlorar mindre \u00e4n 1% per m\u00e5nad i standby (om BMS vilostr\u00f6m \u00e4r l\u00e5g) s\u00e4kerst\u00e4ller det att din \"svartstartskapacitet\" bevaras \u00e4ven efter m\u00e5nader av n\u00e4tstabilitet. AGM-batterier kan \"soft-faila\" under samma tidsram om flott\u00f6rladdaren inte fungerar.<\/p>","protected":false},"excerpt":{"rendered":"<p>AGM (Absorbent Glass Mat) batteries have long been the industry standard for standby power, but their sensitivity to thermal stress and float-charging degradation is forcing a global shift. As Sodium-ion (Na-ion) emerges as a high-performance alternative, the real hurdle for procurement officers and industrial engineers in the US and Europe isn&#8217;t just cost\u2014it\u2019s technical integration&#8230;.<\/p>","protected":false},"author":1,"featured_media":1181,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5167","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts\/5167","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/comments?post=5167"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts\/5167\/revisions"}],"predecessor-version":[{"id":5168,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts\/5167\/revisions\/5168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/media?parent=5167"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/categories?post=5167"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/tags?post=5167"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}