{"id":5160,"date":"2026-05-09T06:56:02","date_gmt":"2026-05-09T06:56:02","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5160"},"modified":"2026-05-09T07:58:12","modified_gmt":"2026-05-09T07:58:12","slug":"12v-200ah-sodium-ion-battery-for-south-africa-load-shedding-runtime-recharge-and-inverter-sizing","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sv\/news\/12v-200ah-sodium-ion-battery-for-south-africa-load-shedding-runtime-recharge-and-inverter-sizing\/","title":{"rendered":"12V 200Ah Sodium-Ion Battery for South Africa Load Shedding Runtime Recharge and Inverter Sizing"},"content":{"rendered":"<p>A <strong><a href=\"https:\/\/www.kmdpower.com\/sv\/kamada-power-12v-200ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 200Ah natriumjonbatteri<\/a><\/strong> can support South African load-shedding backup for homes, shops, clinics and estate projects, but only if it matches the real load, recharge window, inverter settings and BMS limits.<\/p><p>With about 2.4kWh nominal energy, it may provide around 2.16kWh usable battery-side energy at 90% DoD before inverter losses. This can comfortably cover a 420W load for 2 hours, and may support 4 hours if loads are controlled and the system is properly matched.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Kamada-Power-12V-200Ah-Sodium-ion-Battery-003.jpg\" alt=\"\" class=\"wp-image-1190\"\/><\/figure><p class=\"has-text-align-center\"><strong><a href=\"https:\/\/www.kmdpower.com\/sv\/kamada-power-12v-200ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12v 200Ah natriumjonbatteri<\/a><\/strong><\/p><h2 class=\"wp-block-heading\" id=\"can-a-12v-200ah-sodium-ion-battery-handle-a-2-hour-outage-\">Can a 12V 200Ah Sodium-Ion Battery Handle a 2-Hour Outage?<\/h2><p>Yes, for many essential-load setups, one 12V 200Ah sodium-ion battery can handle a 2-hour outage. A typical essential-load profile might include Wi-Fi, lights, a TV, laptops and a modern fridge. If the AC load is around&nbsp;<strong>420W<\/strong>, a 2-hour outage consumes:<\/p><p><strong>420W \u00d7 2h = 840Wh AC energy<\/strong><\/p><p>After inverter losses, the battery may need to supply:<\/p><p><strong>840Wh \u00f7 0.90 inverter efficiency \u2248 933Wh battery energy<\/strong><\/p><p>At 12V, this is roughly:<\/p><p><strong>933Wh \u00f7 12V \u2248 78Ah<\/strong><\/p><p>A 12V 200Ah pack with about 180Ah usable capacity can handle that 2-hour slot with margin. The real challenge is not only runtime; it is whether the battery can recover enough energy during the grid-on window before the next outage.<\/p><h2 class=\"wp-block-heading\" id=\"load-shedding-battery-sizing-formula\">Load-Shedding Battery Sizing Formula<\/h2><p>Use this simplified formula:<\/p><p><strong>Battery Energy Needed, Wh = Load Power, W \u00d7 Backup Hours \u00f7 Inverter Efficiency<\/strong><\/p><p>Then convert to nominal amp-hours:<\/p><p><strong>Battery Ah Needed = Battery Energy Needed, Wh \u00f7 Battery Voltage \u00f7 Usable DoD<\/strong><\/p><p>For a 420W load, 2-hour outage, 90% inverter efficiency and 90% usable DoD:<\/p><p><strong>420W \u00d7 2h \u00f7 0.90 = 933Wh<\/strong><\/p><p><strong>933Wh \u00f7 12V \u00f7 0.90 = 86.4Ah nominal battery capacity<\/strong><\/p><p>So a 12V 200Ah battery is not being pushed hard in a 2-hour slot. That lower stress can help support longer service life, provided charge voltage, current, temperature and BMS limits are correct.<\/p><h2 class=\"wp-block-heading\" id=\"example-essential-load-for-a-south-african-home\">Example Essential Load for a South African Home<\/h2><p>Do not size your battery from wishful thinking. List the loads that must stay on during load shedding.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Essential Load<\/th><th>Typisk effekt<\/th><th>2-Hour Energy Use<\/th><th>Sizing Note<\/th><\/tr><\/thead><tbody><tr><td>Wi-Fi router + fiber ONT<\/td><td>15W<\/td><td>30Wh<\/td><td>Low power but critical<\/td><\/tr><tr><td>LED-lampor<\/td><td>30\u201350W<\/td><td>60\u2013100Wh<\/td><td>Easy to support<\/td><\/tr><tr><td>TV + streaming device<\/td><td>80\u2013120W<\/td><td>160\u2013240Wh<\/td><td>Optional in strict backup mode<\/td><\/tr><tr><td>Two laptops<\/td><td>80\u2013130W<\/td><td>160\u2013260Wh<\/td><td>Depends on charger use<\/td><\/tr><tr><td>Modern fridge\/freezer<\/td><td>100\u2013250W average<\/td><td>200\u2013500Wh<\/td><td>Compressor surge must be checked<\/td><\/tr><tr><td>CCTV \/ alarm \/ gate standby<\/td><td>20\u201380W<\/td><td>40\u2013160Wh<\/td><td>Important for security<\/td><\/tr><\/tbody><\/table><\/figure><p>A realistic essential load often lands between&nbsp;<strong>300W and 600W<\/strong>. Kettles, heaters, geysers, ovens and large pumps should not be included in a small 12V backup design.<\/p><h2 class=\"wp-block-heading\" id=\"runtime-estimate-under-different-loads\">Runtime Estimate Under Different Loads<\/h2><p>Assume a 12V 200Ah sodium-ion pack, 90% usable DoD and 90% inverter efficiency. The practical AC-side usable energy is roughly:<\/p><p><strong>12V \u00d7 200Ah \u00d7 0.90 DoD \u00d7 0.90 inverter efficiency \u2248 1,944Wh AC usable energy<\/strong><\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>AC Load<\/th><th>Ber\u00e4knad k\u00f6rtid<\/th><th>Practical Meaning<\/th><\/tr><\/thead><tbody><tr><td>300W<\/td><td>Cirka 6,5 timmar<\/td><td>Wi-Fi, lights, laptop, light fridge cycling<\/td><\/tr><tr><td>420W<\/td><td>About 4.6 hours<\/td><td>Typical essential home load<\/td><\/tr><tr><td>500W<\/td><td>About 3.9 hours<\/td><td>Good for 2-hour slots, moderate for 4-hour slots<\/td><\/tr><tr><td>800W<\/td><td>About 2.4 hours<\/td><td>Can handle 2 hours, but recharge stress increases<\/td><\/tr><\/tbody><\/table><\/figure><p>Real runtime depends on inverter efficiency, low-voltage cutoff, battery temperature, fridge cycling, cable losses and voltage window.<\/p><h2 class=\"wp-block-heading\" id=\"why-load-shedding-damages-many-lead-acid-batteries\">Why Load Shedding Damages Many Lead-Acid Batteries<\/h2><p>Load shedding is hard on batteries because it creates repeated discharge and recharge cycles. The battery may discharge for 2 hours, recharge for only a few hours, then discharge again. It may not return to full charge before the next blackout.<\/p><p>This is where AGM and GEL lead-acid batteries often struggle. Frequent partial-state-of-charge operation can accelerate sulfation, increase internal resistance and reduce usable capacity. A battery that looks correctly sized on paper may lose performance quickly if it is repeatedly cycled without reaching full charge.<\/p><p>Sodium-ion does not suffer from lead-acid sulfation, which helps in repeated partial-charge operation. However, this does not mean zero aging. Cycle life still depends on DoD, C-rate, temperature, charge voltage, cutoff, cell design and BMS protection.<\/p><h2 class=\"wp-block-heading\" id=\"the-2-hour-discharge-and-4-hour-recharge-test\">The 2-Hour Discharge and 4-Hour Recharge Test<\/h2><p>For South African backup systems, runtime is only half the design. Recharge speed matters just as much.<\/p><p>Using the 420W example:<\/p><p><strong>2-hour outage energy = 840Wh AC<\/strong><\/p><p>Battery-side energy after inverter losses:<\/p><p><strong>840Wh \u00f7 0.90 \u2248 933Wh<\/strong><\/p><p>At 12V:<\/p><p><strong>933Wh \u00f7 12V \u2248 78Ah<\/strong><\/p><p>To recover 78Ah in a 4-hour grid-on window:<\/p><p><strong>78Ah \u00f7 4h = 19.5A<\/strong><\/p><p>After charging losses and BMS limits, a&nbsp;<strong>20A\u201330A charger<\/strong>&nbsp;is usually more realistic than a weak trickle charger. Higher loads or shorter recharge windows need more current.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Scenario<\/th><th>Battery Energy to Replace<\/th><th>Minimum Average Charge Current<\/th><th>Practical Charger Target<\/th><\/tr><\/thead><tbody><tr><td>420W for 2h<\/td><td>~78Ah<\/td><td>~20A over 4h<\/td><td>20A\u201330A<\/td><\/tr><tr><td>500W for 2h<\/td><td>~93Ah<\/td><td>~23A over 4h<\/td><td>30A<\/td><\/tr><tr><td>500W for 4h<\/td><td>~185Ah<\/td><td>~46A over 4h<\/td><td>50A+<\/td><\/tr><tr><td>800W for 2h<\/td><td>~148Ah<\/td><td>~37A over 4h<\/td><td>40A\u201350A<\/td><\/tr><\/tbody><\/table><\/figure><p>A 12V 200Ah Sodium ion battery can still fail if the charger is too small. It must run the load and recover before the next outage.<\/p><h2 class=\"wp-block-heading\" id=\"where-sodium-ion-battery-helps-in-load-shedding-backup\">Where Sodium-Ion Battery Helps in Load-Shedding Backup<\/h2><p>A sodium-ion battery can be useful in load-shedding systems for four reasons.<\/p><p>First, it can support high usable capacity when designed with a suitable BMS and rated DoD. Second, it avoids lead-acid sulfation, which is valuable in repeated partial-charge operation. Third, sodium-ion packs can be designed for strong charge acceptance, helping the battery recover during shorter grid-on windows. Fourth, sodium-ion can offer attractive safety and temperature characteristics depending on cell chemistry, pack design and certifications.<\/p><p>But no battery should be marketed as \u201cimpossible to burn.\u201d Safety depends on BMS protection, enclosure, wiring, fusing and installation quality.<\/p><h2 class=\"wp-block-heading\" id=\"sodium-ion-vs-lifepo4-vs-lead-acid-for-load-shedding\">Sodium-Ion vs LiFePO4 vs Lead-Acid for Load Shedding<\/h2><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Beslutsfaktor<\/th><th>Lead-Acid AGM\/GEL<\/th><th>LiFePO4<\/th><th>Natriumjon<\/th><\/tr><\/thead><tbody><tr><td>Partial-charge operation<\/td><td>Weak to moderate; sulfation risk<\/td><td>Stark<\/td><td>Strong; no lead-sulfate mechanism<\/td><\/tr><tr><td>Usable energy<\/td><td>Lower under deep cycling<\/td><td>H\u00f6g<\/td><td>High, if pack is rated for it<\/td><\/tr><tr><td>Recharge window<\/td><td>Slower near full charge<\/td><td>Fast if charger\/BMS allow<\/td><td>Fast if charger\/BMS allow<\/td><\/tr><tr><td>Cykellivsl\u00e4ngd<\/td><td>Lower under frequent cycling<\/td><td>H\u00f6g<\/td><td>Potentially high; verify test conditions<\/td><\/tr><tr><td>Heat tolerance<\/td><td>Life shortens in heat<\/td><td>Requires derating<\/td><td>Verify pack and enclosure design<\/td><\/tr><tr><td>S\u00e4kerhet<\/td><td>Venting\/hydrogen risk if abused<\/td><td>Good with proper BMS<\/td><td>Strong potential with proper BMS<\/td><\/tr><tr><td>B\u00e4sta passform<\/td><td>Low-cost occasional backup<\/td><td>Mature high-performance backup<\/td><td>Frequent partial-charge backup where voltage compatibility is confirmed<\/td><\/tr><\/tbody><\/table><\/figure><p>The takeaway is not that sodium-ion automatically beats LiFePO4. LiFePO4 is mature and widely supported. Sodium-ion becomes attractive where frequent cycling, partial-charge operation and fast recovery are priorities.<\/p><h2 class=\"wp-block-heading\" id=\"inverter-compatibility-do-not-copy-lithium-settings-blindly\">Inverter Compatibility: Do Not Copy Lithium Settings Blindly<\/h2><p>A 12V sodium-ion battery is not automatically compatible with every 12V inverter setting. Some inverters allow user-defined charge voltage, low-voltage cutoff and charge current. Others are locked to lead-acid or lithium profiles.<\/p><p>Before installation, confirm these items:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Setting<\/th><th>What to Confirm<\/th><th>Varf\u00f6r det \u00e4r viktigt<\/th><\/tr><\/thead><tbody><tr><td>Battery charge voltage<\/td><td>Manufacturer-recommended bulk\/absorption voltage<\/td><td>Sodium-ion voltage windows vary by pack design<\/td><\/tr><tr><td>Float or standby voltage<\/td><td>Whether float is required or limited<\/td><td>Wrong standby voltage can reduce service life<\/td><\/tr><tr><td>Low-voltage cutoff<\/td><td>Battery-side cutoff and inverter cutoff<\/td><td>Too high reduces usable capacity; too low risks BMS shutdown<\/td><\/tr><tr><td>Max charge current<\/td><td>Charger output vs BMS charge limit<\/td><td>Determines recovery between outages<\/td><\/tr><tr><td>Max discharge current<\/td><td>Inverter load and surge vs BMS rating<\/td><td>Prevents shutdown during compressor surge<\/td><\/tr><tr><td>Cable and fuse rating<\/td><td>Current, cable length, DC protection<\/td><td>Reduces voltage drop and fire risk<\/td><\/tr><\/tbody><\/table><\/figure><p>Do not assume a 14.4V lithium-style setting is correct for every sodium-ion battery. Always use the sodium-ion battery manufacturer\u2019s datasheet. If the inverter cannot support the required voltage window, usable capacity, charging speed or BMS behavior may be affected.<\/p><h2 class=\"wp-block-heading\" id=\"who-is-a-12v-200ah-sodium-ion-battery-right-for-\">Who Is a 12V 200Ah Sodium-Ion Battery Right For?<\/h2><p>A single <strong><a href=\"https:\/\/www.kmdpower.com\/sv\/kamada-power-12v-200ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 200Ah natriumjonbatteri<\/a><\/strong> is a good candidate for essential backup loads, not whole-home electrification.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Anv\u00e4ndartyp<\/th><th>Suitable Loads<\/th><th>Caution<\/th><\/tr><\/thead><tbody><tr><td>Homeowner<\/td><td>Wi-Fi, lights, TV, laptops, fridge cycling<\/td><td>Avoid heaters, kettles, geysers, ovens<\/td><\/tr><tr><td>Small shop<\/td><td>Router, POS, lights, laptop, security<\/td><td>Check fridge or motor surge loads<\/td><\/tr><tr><td>Clinic or pharmacy<\/td><td>Router, lights, small medical fridge, laptop<\/td><td>Use measured fridge load and alarm backup<\/td><\/tr><tr><td>Estate procurement<\/td><td>Standardized essential-load kits<\/td><td>Require inverter compatibility and installation SOP<\/td><\/tr><tr><td>Installer<\/td><td>Retrofit from failing lead-acid backup<\/td><td>Confirm charger profile and cable sizing<\/td><\/tr><\/tbody><\/table><\/figure><p>If your load is under 500W, one 12V 200Ah pack may be practical. If it is closer to 800W\u20131,000W, consider a larger bank, 24V\/48V system, or load reduction plan.<\/p><h2 class=\"wp-block-heading\" id=\"common-sizing-mistakes\">Common Sizing Mistakes<\/h2><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Mistake<\/th><th>Resultat<\/th><th>Better Approach<\/th><\/tr><\/thead><tbody><tr><td>Sizing by Ah only<\/td><td>Overestimates runtime<\/td><td>Convert loads into Wh first<\/td><\/tr><tr><td>Ignoring inverter losses<\/td><td>Runtime is shorter than expected<\/td><td>Use 85\u201392% efficiency assumption<\/td><\/tr><tr><td>Running heavy appliances<\/td><td>Battery drains too fast<\/td><td>Separate essential and non-essential loads<\/td><\/tr><tr><td>Using a weak charger<\/td><td>Battery never recovers between outages<\/td><td>Match charger current to recharge window<\/td><\/tr><tr><td>Copying LiFePO4 settings<\/td><td>Poor charging or BMS shutdown<\/td><td>Use sodium-ion pack datasheet<\/td><\/tr><tr><td>Ignoring compressor surge<\/td><td>Fridge or pump trips inverter<\/td><td>Check inverter surge and BMS peak current<\/td><\/tr><tr><td>Using thin DC cables<\/td><td>Voltage drop and heat<\/td><td>Size cable and fuse for peak current<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"wp-block-heading\" id=\"practical-sizing-workflow\">Practical Sizing Workflow<\/h2><p>Before buying, list essential loads, add running watts, multiply by backup hours, divide by inverter efficiency, divide by battery voltage, then divide by usable DoD. After that, check inverter surge, BMS current, recharge current, charge voltage, low-voltage cutoff, cable size, fuse rating and enclosure conditions.<\/p><p>For accurate sizing, send your supplier your inverter model, load list, backup duration, recharge window, cable length and installation environment.<\/p><h2 class=\"wp-block-heading\" id=\"conclusion\">Slutsats<\/h2><p>A <strong><a href=\"https:\/\/www.kmdpower.com\/sv\/kamada-power-12v-200ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 200Ah natriumjonbatteri<\/a><\/strong> can be a strong load-shedding backup solution for South African homes, clinics, small shops, and estate projects when it is sized around real loads, inverter efficiency, recharge windows, and BMS limits. For a 420W essential load, it can usually handle a 2-hour outage with good margin, while 4-hour backup or higher loads require closer checks on usable DoD, inverter cutoff, charge current, compressor surge, cable sizing, and voltage settings. Sodium-ion\u2019s real value is its resistance to lead-acid sulfation, frequent cycling capability, and strong recovery in partial-charge backup use when properly specified.\u00a0<strong><a href=\"https:\/\/www.kmdpower.com\/sv\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kontakta Kamada Power<\/a> to design the right 12V 200Ah sodium-ion backup system for your South Africa load-shedding application.<\/strong><\/p><h2 class=\"wp-block-heading\" id=\"faq\">VANLIGA FR\u00c5GOR<\/h2><h3 class=\"wp-block-heading\" id=\"can-one-12v-200ah-sodium-ion-battery-run-a-home-during-load-shedding-\">Can one 12V 200Ah sodium-ion battery run a home during load shedding?<\/h3><p>It can run essential loads, not an entire home. For Wi-Fi, lights, laptops, TV and a modern fridge cycling load, it can often cover a 2-hour outage with margin. Heavy heating loads, kettles, geysers, ovens and large pumps should be excluded from a small 12V backup system.<\/p><h3 class=\"wp-block-heading\" id=\"how-long-will-a-12v-200ah-battery-last-with-a-420w-load-\">How long will a 12V 200Ah battery last with a 420W load?<\/h3><p>With 90% usable DoD and about 90% inverter efficiency, the estimated AC-side usable energy is about 1.94kWh. At 420W, runtime is roughly 4.6 hours. In real installations, allow margin for fridge surge, inverter cutoff, battery temperature and cable losses.<\/p><h3 class=\"wp-block-heading\" id=\"can-it-recover-during-a-4-hour-grid-on-window-\">Can it recover during a 4-hour grid-on window?<\/h3><p>For a 420W load over 2 hours, the battery may need to replace around 78Ah. Over 4 hours, that requires about 20A average charging current before losses. A 20A\u201330A charger may be enough for this case, while higher loads or shorter recharge windows need more charging current.<\/p><h3 class=\"wp-block-heading\" id=\"is-sodium-ion-safer-than-lithium-\">Is sodium-ion safer than lithium?<\/h3><p>Sodium-ion has strong safety potential, but safety depends on cell chemistry, BMS design, enclosure, wiring, fusing and certification. It should not be described as impossible to burn. A well-designed battery system is safer than a poorly installed one, regardless of chemistry.<\/p><h3 class=\"wp-block-heading\" id=\"can-i-use-my-old-lead-acid-charger-\">Can I use my old lead-acid charger?<\/h3><p>Not automatically. Use a charger or inverter that can match the sodium-ion battery manufacturer\u2019s voltage and current settings. Old \u201cdumb\u201d chargers are not recommended because they may not control charge voltage or termination accurately.<\/p><h3 class=\"wp-block-heading\" id=\"can-i-add-a-second-12v-200ah-battery-later-\">Can I add a second 12V 200Ah battery later?<\/h3><p>Often yes, if the manufacturer supports parallel connection. Use the same model, similar age, equal cable lengths, correct fusing and manufacturer-approved connection limits. For larger systems, a 24V or 48V design may be more efficient than adding many 12V batteries in parallel.<\/p>","protected":false},"excerpt":{"rendered":"<p>A 12V 200Ah sodium-ion battery can support South African load-shedding backup for homes, shops, clinics and estate projects, but only if it matches the real load, recharge window, inverter settings and BMS limits. With about 2.4kWh nominal energy, it may provide around 2.16kWh usable battery-side energy at 90% DoD before inverter losses. This can comfortably&#8230;<\/p>","protected":false},"author":1,"featured_media":1190,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[26,19],"tags":[],"class_list":["post-5160","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product-news","category-news_catalog"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts\/5160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/comments?post=5160"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts\/5160\/revisions"}],"predecessor-version":[{"id":5161,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/posts\/5160\/revisions\/5161"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/media\/1190"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/media?parent=5160"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/categories?post=5160"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sv\/wp-json\/wp\/v2\/tags?post=5160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}