{"id":5322,"date":"2026-11-20T06:09:55","date_gmt":"2026-11-20T06:09:55","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5322"},"modified":"2026-11-20T06:09:57","modified_gmt":"2026-11-20T06:09:57","slug":"can-one-12v-sodium-ion-battery-power-mixed-5v-12v-and-24v-surveillance-equipment","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sl\/news\/can-one-12v-sodium-ion-battery-power-mixed-5v-12v-and-24v-surveillance-equipment\/","title":{"rendered":"Can One 12V Sodium-Ion Battery Power Mixed 5V  12V and 24V Surveillance Equipment?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">An outdoor surveillance cabinet may contain a 5V edge computer, a 12V camera and a 24V wireless bridge. One battery seems simpler than three, but <strong>a shared battery does not produce three regulated voltages<\/strong>. A <strong><a href=\"https:\/\/www.kmdpower.com\/sl\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V 100Ah natrijev ionski akumulator<\/a><\/strong> pack is a candidate only if all branches work through charging, startup and BMS events.<\/p><p class=\"wp-block-paragraph\">One 12V pack may power all three loads <strong>through properly selected DC-DC branches<\/strong>. Check input limits, cable drop, rail accuracy, peaks, derating and BMS recovery. The pack&#8217;s <strong>8V discharge cutoff is not a normal operating target<\/strong>; an earlier system shutdown may be needed.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Sodium-Battery-12V-100Ah-Bluetooth-Low-Temperature-Na-Ion-Battery-Supplier-Factory-Manufacturers-001.jpg\" alt=\"\" class=\"wp-image-1451\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/sl\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100ah Natrijeva ionska baterija<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">What Does the Surveillance Equipment BOM Actually Require?<\/h2><p class=\"wp-block-paragraph\">Start with the device BOM, not battery Ah:<\/p><ul class=\"wp-block-list\"><li><strong>5V edge computing:<\/strong> Raspberry Pi 5 recommends a <strong>5.1V, 5A-capable USB-C supply<\/strong> for full peripheral power; it does not constantly draw 25W. Without recognized 5A capability, USB peripherals may be limited to <strong>600mA<\/strong>. A bare 5V DC-DC converter is not automatically a suitable USB-C source: verify source recognition, board-end voltage, peripherals and peaks. <a href=\"https:\/\/www.raspberrypi.com\/documentation\/computers\/raspberry-pi.html\" target=\"_blank\" rel=\"noreferrer noopener\">Raspberry Pi documentation<\/a>.<\/li>\n\n<li><strong>12V camera or router rail:<\/strong> Some cameras require a narrow regulated 12V supply; others accept wider DC input. Check each device&#8217;s approved range, ripple, startup and peak load. A \u201c12V\u201d label is not a tolerance.<\/li>\n\n<li><strong>24V communications rail:<\/strong> Ubiquiti&#8217;s NanoBeam 5AC Gen2 specifies <strong>20\u201327V DC<\/strong>, <strong>8.5W maximum<\/strong>in <strong>24V passive PoE<\/strong> on pairs <strong>4\/5 positive and 7\/8 return<\/strong>. That supply method is not interchangeable with IEEE 802.3af\/at active PoE. <a href=\"https:\/\/techspecs.ui.com\/uisp\/wireless\/nanobeam-5ac?subcategory=all-wireless\" target=\"_blank\" rel=\"noreferrer noopener\">Official device specifications<\/a>.<\/li><\/ul><p class=\"wp-block-paragraph\">Teltonika&#8217;s RUT241 accepts <strong>9\u201330V DC<\/strong> via its power connector or specified LAN1 <strong>passive PoE<\/strong>; LAN1 is <strong>not IEEE 802.3af\/at compatible<\/strong>. Check charging voltage, wiring and supply-change behavior rather than assuming a seamless transfer. <a href=\"https:\/\/wiki.teltonika-networks.com\/view\/RUT241_Powering_Options\" target=\"_blank\" rel=\"noreferrer noopener\">RUT241 power options<\/a>.<\/p><p class=\"wp-block-paragraph\">For each device, record <strong>input range, maximum and measured W, startup, connector and uptime requirement<\/strong>.<\/p><h2 class=\"wp-block-heading\">Which Loads Need DC-DC Conversion Rather Than a Direct 12V Connection?<\/h2><p class=\"wp-block-paragraph\">Uporabite <strong>exact finished-pack specification<\/strong>. Na spletni strani . <strong>Kamada Power 12V 100Ah natrijev ionski akumulator<\/strong> datasheet supplied for this review specifies <strong>Nazivna napetost 12 V, 100 Ah, nazivna energija 1.200 Wh, najve\u010dja napetost polnjenja 15,6 V in mejna napetost praznjenja 8 V<\/strong>, with built-in BMS protection. These are <strong>not a discharge curve<\/strong>; service cutoff and BMS recovery remain undocumented. A separate <a href=\"https:\/\/www.kmdpower.com\/sl\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100Ah natrijev ionski akumulator<\/a> bears a <strong>Oznaka modela 12,8 V<\/strong>. Keep revisions separate.<\/p><p class=\"wp-block-paragraph\">A first-pass architecture:<\/p><pre class=\"wp-block-code\"><code>APPROVED 12V SODIUM-ION PACK + BMS\n                 |\n          Protected DC bus\n                 |\n                 |-- 5V DC-DC --&gt; qualified USB-C --&gt; Edge computer\n                 |-- 12V regulator -----------&gt; 12V camera\n                 `-- 24V DC-DC --&gt; passive-PoE injector --&gt; Wireless bridge\n<\/code><\/pre><p class=\"wp-block-paragraph\"><em>Concept only; validate the USB-C interface, branch protection and wiring for the actual BOM.<\/em><\/p><p class=\"wp-block-paragraph\">The Pi needs a compliant USB-C power interface, not just 5V output. The 24V bridge needs <strong>a rated converter and correctly wired passive-PoE injector<\/strong>; a narrow-range 12V camera may need buck-boost regulation. Check any direct connection against the full voltage range.<\/p><h3 class=\"wp-block-heading\">A converter specification can reveal a battery-range mismatch<\/h3><p class=\"wp-block-paragraph\">MEAN WELL&#8217;s DDR-60G models give a useful published comparison:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>DC-DC model<\/th><th>Published input<\/th><th>Output \/ rated power<\/th><th>Typical efficiency*<\/th><\/tr><\/thead><tbody><tr><td>DDR-60G-5<\/td><td><strong>9\u201336V DC<\/strong><\/td><td>5V \/ 54W<\/td><td>87.5%<\/td><\/tr><tr><td>DDR-60G-12<\/td><td><strong>9\u201336V DC<\/strong><\/td><td>12V \/ 60W<\/td><td>91%<\/td><\/tr><tr><td>DDR-60G-24<\/td><td><strong>9\u201336V DC<\/strong><\/td><td>24V \/ 60W<\/td><td>91%<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\"><em>Reference ratings, not validated <strong><a href=\"https:\/\/www.kmdpower.com\/sl\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power natrijeva ionska baterija<\/a><\/strong> system choices. Typical efficiencies depend on test conditions. Source:<\/em> <a href=\"https:\/\/www.meanwell.com\/Upload\/PDF\/DDR-60\/DDR-60-SPEC.PDF\" target=\"_blank\" rel=\"noreferrer noopener\"><em>MEAN WELL official DDR-60 datasheet<\/em><\/a><em>.<\/em><\/p><p class=\"wp-block-paragraph\">For G-type units, MEAN WELL specifies <strong>power ON \u22659V<\/strong> in . <strong>OFF \u22648.5V<\/strong>. At <strong>9\u201318V input<\/strong>, the published derating curves show <strong>75% rated load (DDR-60G-5)<\/strong> in . <strong>85% (DDR-60G-12\/24)<\/strong>\u2014about <strong>40.5W<\/strong> in . <strong>51W<\/strong>, before additional high-temperature derating. Check the actual enclosure temperature.<\/p><p class=\"wp-block-paragraph\">The converters&#8217; input rating includes <strong>15.6V<\/strong>, but excludes the pack&#8217;s <strong>Za\u0161\u010ditna prekinitev pri 8 V<\/strong>. That need not rule them out if an approved <strong>system LVD\/LVR<\/strong> keeps their terminals above the required operating and restart limits, with margin for cable drop and load peaks. <strong>9V is not a recommended LVD setting<\/strong>; operation below the rated 9V input is unqualified. If lower-voltage operation is required, change the converter or architecture.<\/p><h2 class=\"wp-block-heading\">How Do Startup and Converter Idle Draw Affect a Shared DC Bus?<\/h2><p class=\"wp-block-paragraph\">Average watts miss startup. Converter inrush and device boot can sag a shared bus, reset cameras or trigger BMS protection. <strong>Restart requires the 9V input condition<\/strong>, and a safe LVD\/LVR should provide measured headroom above it.<\/p><p class=\"wp-block-paragraph\">Log <strong>pack current and each converter&#8217;s input voltage<\/strong> during simultaneous and staggered starts. Verify output rise, device reboots and unattended recovery.<\/p><p class=\"wp-block-paragraph\">Measure converter idle draw at the actual battery voltage; include it in the 24-hour energy budget. A common bus is <strong>ni nujno UPS<\/strong>. Define which loads must remain online and whether a reboot is acceptable.<\/p><h2 class=\"wp-block-heading\">How Much Power Must the Battery Deliver to Three DC Rails?<\/h2><p class=\"wp-block-paragraph\"><strong>Hypothetical example:<\/strong> 12W at 5V, 18W at 12V and 8W at 24V, using published typical efficiencies. <strong>These are not tested loads.<\/strong> In particular, 8W is below the NanoBeam&#8217;s <strong>8.5W maximum<\/strong>; design for the real device maximum, injector\/cable losses and peaks.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Branch<\/th><th>Assumed output load<\/th><th>Illustrative efficiency<\/th><th>Calculated battery-side power<\/th><\/tr><\/thead><tbody><tr><td>5V edge rail<\/td><td>12W<\/td><td>87.5%<\/td><td><strong>13.7W<\/strong><\/td><\/tr><tr><td>12V camera rail<\/td><td>18W<\/td><td>91%<\/td><td><strong>19.8W<\/strong><\/td><\/tr><tr><td>24V radio rail<\/td><td>8W<\/td><td>91%<\/td><td><strong>8.8W<\/strong><\/td><\/tr><tr><td><strong>Skupaj<\/strong><\/td><td><strong>38W<\/strong><\/td><td>-<\/td><td><strong>42.3W<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\"><strong>Figure 1 \u2014 Illustrative delivered load vs. estimated battery input by DC rail<\/strong><\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"565\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget-1024x565.png\" alt=\"\" class=\"wp-image-5323\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget-1024x565.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget-300x166.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget-767x423.png 767w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget-18x10.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget-600x331.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget-1536x847.png 1536w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-07_Mixed_Rail_DC_Power_Budget.png 2030w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\"><em>Illustrative output and calculated input power\u2014not Kamada Power field measurements or actual NanoBeam peak consumption.<\/em><\/p><p class=\"wp-block-paragraph\">At an illustrative <strong>12.0V bus<\/strong>, 42.3W draws <strong>about 3.5A<\/strong>; at 9V, <strong>about 4.7A<\/strong> if efficiency remained unchanged. Allow for cable drop; these converters are <strong>not rated below 9V<\/strong>.<\/p><p class=\"wp-block-paragraph\">The pack&#8217;s <strong>1,200Wh nominal \u00f7 42.3W \u2248 28.4 hours<\/strong> je . <em>ideal arithmetic, not proven uptime<\/em>. Actual runtime depends on usable Wh, approved cutoff, temperature and converter losses. For real loads use <strong>P_pack = \u03a3(P_rail \/ \u03b7_rail) + measured auxiliary draw<\/strong>, with measured efficiency at the expected operating point. See Kamada Power <a href=\"https:\/\/www.kmdpower.com\/sl\/news\/can-sodium-ion-batteries-be-integrated-with-existing-12v-or-24v-systems\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V\/24V Sodium ion battery integration guide<\/a> for the wider voltage-system topic.<\/p><h2 class=\"wp-block-heading\">What Failures Can One Shared 12V Bus Create Across the System?<\/h2><p class=\"wp-block-paragraph\">A shared source creates common-mode risks, but <strong>a failure on one branch need not disable the others if protection and isolation work as designed<\/strong>.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Fault observed<\/th><th>Possible result<\/th><th>Kaj je treba preveriti<\/th><\/tr><\/thead><tbody><tr><td>5V branch or USB-C supply fault<\/td><td>Edge processor resets; cameras may still have power<\/td><td>Independent protection and Pi supply status<\/td><\/tr><tr><td>12V camera branch fault<\/td><td>Camera loses power<\/td><td>Fuse\/branch isolation and surviving bus voltage<\/td><\/tr><tr><td>24V converter or passive-PoE fault<\/td><td>Wireless link drops<\/td><td>Injector polarity, output and branch protection<\/td><\/tr><tr><td>BMS discharge interruption or common-bus sag<\/td><td>All three rails may be lost or reboot<\/td><td>BMS event, bus waveform and unattended restart<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Provide properly rated branch protection; a converter&#8217;s own short-circuit function does not automatically replace wiring protection. Test fault isolation safely, without shorting wiring or bypassing the BMS.<\/p><p class=\"wp-block-paragraph\">The issue here is <strong>fault isolation among unequal-voltage loads<\/strong>, not generic 12V-versus-24V cable sizing.<\/p><h2 class=\"wp-block-heading\">When Is One 12V Pack Better Than a Different DC Architecture?<\/h2><p class=\"wp-block-paragraph\">One shared pack may simplify inventory and packaging, but evaluate <strong>voltage overlap, protection, output derating, heat, continuity and charging<\/strong> before increasing capacity.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Verified condition<\/th><th>Engineering and purchasing outcome<\/th><\/tr><\/thead><tbody><tr><td>Every DC-DC input covers the <strong>planned service voltage<\/strong>, charger range and required restart conditions; all rail tests pass<\/td><td><strong>Qualify<\/strong> that battery-bus design and hardware revision<\/td><\/tr><tr><td>Camera needs tightly regulated 12V; Raspberry Pi needs compatible USB-C power recognition<\/td><td><strong>Use qualified regulated interfaces<\/strong> rather than direct nominal-voltage wiring<\/td><\/tr><tr><td>24V radio needs an approved passive-PoE injector with correct pairs and adequate voltage at the device<\/td><td><strong>Choose the correct converter\/injector<\/strong>, not an arbitrary active-PoE source<\/td><\/tr><tr><td>Startup or low-input\/temperature derating exceeds converter or BMS limits<\/td><td><strong>Change power hardware or startup strategy<\/strong>; extra Ah alone is not proof of a fix<\/td><\/tr><tr><td>Voltage or BMS recovery is incompatible with the required service window<\/td><td><strong>Change converter, shutdown policy or architecture; reject an unfixable pairing<\/strong><\/td><\/tr><tr><td>Only runtime or per-pack current is insufficient and interfaces otherwise pass<\/td><td>Consider <strong>manufacturer-approved parallel expansion<\/strong> with measured current and Wh<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Approved parallel packs can increase reserve and sometimes reduce voltage sag, but do not create a 24V bank or cure an incompatible input threshold. Do not assume series approval. For high-power 24V loads, a different DC architecture may be more practical.<\/p><h2 class=\"wp-block-heading\">How Should an OEM Qualify the Complete Pack-to-DC-Distribution System?<\/h2><p class=\"wp-block-paragraph\">Preizkusite <strong>actual equipment BOM and exact pack revision<\/strong>:<\/p><ol class=\"wp-block-list\"><li><strong>Voltage envelope:<\/strong> document <strong>15.6V charging limit, 8V protective cutoff<\/strong>, approved LVD\/LVR and BMS recovery. Measure voltage <strong>at each converter input<\/strong>, including cable drop and restart.<\/li>\n\n<li><strong>Rail regulation:<\/strong> test USB-C source recognition, Pi input voltage and peripherals; 12V camera tolerance; 24V passive-PoE wiring and <strong>maximum device watts plus cable loss<\/strong>. Check ripple and voltage\/temperature derating.<\/li>\n\n<li><strong>Simultaneous power-up:<\/strong> capture current peaks, bus sag, <strong>9V converter start requirement<\/strong>, BMS state and reboots; compare staggered startup.<\/li>\n\n<li><strong>Branch interruption:<\/strong> use supported test controls to interrupt one branch and record whether other critical services remain available.<\/li>\n\n<li><strong>Heat and recovery:<\/strong> measure enclosure temperature, converter derating, idle draw and automatic restart after approved low-voltage shutdown.<\/li>\n\n<li><strong>Solar charging and energy balance:<\/strong> verify the pack-approved charger, BMS permissions and camera continuity. Over representative <strong>day\/night cycles<\/strong>, log battery-terminal Wh charged and discharged, and confirm usable reserve does not decline across comparable cycles.<\/li><\/ol><p class=\"wp-block-paragraph\"><strong>Pass<\/strong> only when all applicable battery, charger, converter and device requirements are documented and met. Log revisions and conditions. <strong>Redesign or reject<\/strong> a design that relies on bypassing protection or on unverified recovery.<\/p><h2 class=\"wp-block-heading\">What Should a Surveillance OEM Send for a Battery-Bus Review?<\/h2><p class=\"wp-block-paragraph\">Send the <strong>5V, 12V and 24V device BOM, measured\/maximum watts, power interfaces and uptime priorities<\/strong>, plus converters, charger, schematic, operating temperatures, day\/night Wh requirement and project volume.<\/p><p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.kmdpower.com\/sl\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V 100Ah sodium-ion Battery<\/a> may be evaluated for a protected multi-voltage system. The <a href=\"https:\/\/www.kmdpower.com\/sl\/news\/can-sodium-ion-batteries-be-integrated-with-existing-12v-or-24v-systems\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V\/24V sodium ion battery integration overview<\/a> is general; here the issue is <strong>this pack, BMS and three-rail BOM<\/strong>.<\/p><h2 class=\"wp-block-heading\">Pogosta vpra\u0161anja<\/h2><h3 class=\"wp-block-heading\">Can one 12V battery directly supply 5V, 12V and 24V devices?<\/h3><p class=\"wp-block-paragraph\">Not directly. Use appropriately regulated and connected DC-DC branches for devices requiring 5V, narrow-range 12V or 24V. Any direct connection must pass the full pack, charger and device voltage checks.<\/p><h3 class=\"wp-block-heading\">Can a 24V wireless bridge run on a 12V sodium-ion battery?<\/h3><p class=\"wp-block-paragraph\">Potentially, through a properly rated boost converter and the bridge&#8217;s <strong>approved passive-PoE wiring<\/strong>. The NanoBeam example uses <strong>pairs 4\/5 positive and 7\/8 return<\/strong>; IEEE active PoE is not interchangeable.<\/p><h3 class=\"wp-block-heading\">Why might a 9\u201336V DC-DC converter stop before the battery reaches its lowest allowed voltage?<\/h3><p class=\"wp-block-paragraph\">MEAN WELL specifies <strong>ON \u22659V<\/strong> in . <strong>OFF \u22648.5V<\/strong>; operation below its rated 9V input is not assured. Kamada Power <strong>8V is a protection cutoff<\/strong>, not a service target. Set an approved system LVD\/LVR with cable-drop and restart margin, or change converters.<\/p><h3 class=\"wp-block-heading\">Will two parallel 100Ah packs solve a converter input-voltage problem?<\/h3><p class=\"wp-block-paragraph\">No. Approved parallel operation increases possible reserve and changes load sharing, but not nominal bus voltage or a converter&#8217;s stated minimum input. Voltage sag may improve, yet input compatibility still needs testing.<\/p><h2 class=\"wp-block-heading\">Zaklju\u010dek<\/h2><p class=\"wp-block-paragraph\"><strong>One <a href=\"https:\/\/www.kmdpower.com\/sl\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V Sodium-ion Battery<\/a> pack may power 5V computing, regulated 12V camera equipment and 24V passive-PoE communications through qualified DC-DC branches.<\/strong> The supplied 12V 100Ah sheet specifies <strong>1,200Wh nominal, 15.6V maximum charging and 8V discharge cutoff<\/strong>; none alone establishes usable runtime or required service voltage. Check converter startup, derating, USB-C and PoE interfaces, branch protection and BMS recovery before ordering more Ah. <a href=\"https:\/\/www.kmdpower.com\/sl\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kontakt Kamada Power<\/a> with your surveillance BOM, schematic, charger, operating temperatures and expected annual volume for a revision-specific compatibility review.<\/p>","protected":false},"excerpt":{"rendered":"<p>An outdoor surveillance cabinet may contain a 5V edge computer, a 12V camera and a 24V wireless bridge. One battery seems simpler than three, but a shared battery does not produce three regulated voltages. A Kamada Power 12V 100Ah Sodium ion battery pack is a candidate only if all branches work through charging, startup and&#8230;<\/p>","protected":false},"author":1,"featured_media":1451,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5322","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts\/5322","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/comments?post=5322"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts\/5322\/revisions"}],"predecessor-version":[{"id":5324,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts\/5322\/revisions\/5324"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/media\/1451"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/media?parent=5322"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/categories?post=5322"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/tags?post=5322"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}