{"id":5057,"date":"2026-01-05T08:28:24","date_gmt":"2026-01-05T08:28:24","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5057"},"modified":"2026-01-05T08:28:26","modified_gmt":"2026-01-05T08:28:26","slug":"can-you-safely-build-a-48v-800ah-sodium-ion-battery-for-commercial-ess","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sl\/news\/can-you-safely-build-a-48v-800ah-sodium-ion-battery-for-commercial-ess\/","title":{"rendered":"Ali lahko varno izdelate 48V 800Ah natrijevo-ionsko baterijo za komercialno ESS?"},"content":{"rendered":"<p>Pomanj\u0161evanje obsega\u00a0<strong><a href=\"https:\/\/www.kmdpower.com\/sl\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natrijevo-ionska baterija<\/a> sistem<\/strong>\u00a0ve\u010d kot\u00a0<strong>800 Ah pri 48 V<\/strong>\u00a0ni ve\u010d laboratorijska vaja - je\u00a0<strong>in\u017eenirska odlo\u010ditev, ki je klju\u010dnega pomena za poslanstvo.<\/strong>. Za izvajalce EPC, integratorje ESS in operaterje telekomunikacijskih\/podatkovnih centrov na visokostandardnih trgih, kot so\u00a0<strong>Nem\u010dija<\/strong>, prednostna naloga ni samo gostota energije, temve\u010d tudi\u00a0<strong>zanesljivost sistema, stro\u0161ki \u017eivljenjskega cikla in skladnost z zakonodajo.<\/strong>.<\/p><p>Pogosto tehni\u010dno vpra\u0161anje:<strong>\"Ali lahko zaporedno in vzporedno kombiniram natrijevo-ionsko baterijo, da varno sestavim 48V 800Ah natrijevo-ionski baterijski sistem?\"<\/strong><\/p><p>Ta vodnik vsebuje\u00a0<strong>analiza, ki je nevtralna do prodajalca in osredoto\u010dena na in\u017eeniring.<\/strong>\u00a0zaporednih in vzporednih arhitektur za visokozmogljive <strong><a href=\"https:\/\/www.kmdpower.com\/sl\/izdelek\/kamada-power-10kwh-home-sodium-battery\/\" target=\"_blank\" rel=\"noreferrer noopener\">48V natrijevo-ionska baterija<\/a><\/strong> sistemi in\u00a0<strong>na terenu preizku\u0161ena referen\u010dna arhitektura<\/strong>\u00a0ki se uporabljajo v komercialnih namestitvah.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003.jpg\" alt=\"\" class=\"wp-image-4481\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003.jpg 1000w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-300x300.jpg 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-150x150.jpg 150w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-768x768.jpg 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-12x12.jpg 12w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-600x600.jpg 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><p class=\"has-text-align-center\"><strong><a href=\"https:\/\/www.kmdpower.com\/sl\/izdelek\/kamada-power-10kwh-home-sodium-battery\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 48v 200Ah 10kWh natrijeva ionska baterija<\/a><\/strong><\/p><h2 class=\"wp-block-heading\" id=\"1-why-48v-800ah-is-a-critical-threshold\">1. Zakaj je 48V 800Ah kriti\u010dni prag<\/h2><p>Pri zmogljivostih pod 200-300 Ah je topologija o\u017ei\u010denja ve\u010dinoma priro\u010dna izbira. Nad&nbsp;<strong>800Ah<\/strong>, topologija postane&nbsp;<strong>multiplikator tveganja<\/strong>:<\/p><ul class=\"wp-block-list\"><li><strong>Napa\u010dni tok:<\/strong>\u00a0Potencial kratkega stika &gt; 10 kA, kar zahteva ustrezno dimenzioniranje zbiralnic in varovalke.<\/li>\n\n<li><strong>Sinhronizacija BMS:<\/strong>\u00a0Komunikacijske zamude na ravni milisekund lahko spro\u017eijo prenapetostne ali prenizkonapetostne izklope.<\/li>\n\n<li><strong>Toplotno upravljanje:<\/strong>\u00a0Zaporedno povezani nizi povzro\u010dajo neenakomerno segrevanje, kar pospe\u0161uje okvare naj\u0161ibkej\u0161e povezave.<\/li>\n\n<li><strong>Stro\u0161ki \u017eivljenjskega cikla:<\/strong>\u00a0Nihanje napetosti in neenakomerno staranje celic neposredno vplivata na pogostost zamenjave in stro\u0161ke lastni\u0161tva.<\/li><\/ul><blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>48V 800Ah je kraj, kjer se \"deluje na papirju\" razlikuje od \"deluje na terenu\".<\/strong><\/p><\/blockquote><h2 class=\"wp-block-heading\" id=\"2-series-vs-parallel-architecture-not-chemistry\">2. Zaporedni in vzporedni: Ne kemija, temve\u010d arhitektura.<\/h2><p>Za doseganje 48V 800Ah sta na voljo dva teoreti\u010dna pristopa:<\/p><ol class=\"wp-block-list\"><li><strong>Serijsko-paralelno (S\/P):<\/strong>\u00a012V ali 24V pakete pove\u017eite zaporedno, nato pa jih za pove\u010danje zmogljivosti pove\u017eite vzporedno.<\/li>\n\n<li><strong>Vzporedno napajanje 48 V (samo P):<\/strong>\u00a0Vzporedno pove\u017eite ve\u010d tovarni\u0161ko usklajenih 48-voltnih modulov brez zaporednih povezav.<\/li><\/ol><p>Oba imata nominalno enako napetost\/kapaciteto,&nbsp;<strong>na\u010dini odpovedi se bistveno razlikujejo.<\/strong>.<\/p><h2 class=\"wp-block-heading\" id=\"3-why-series-based-architectures-fail-at-high-capacity\">3. Zakaj zaporedne arhitekture ne uspejo pri visoki zmogljivosti<\/h2><p>Serijske povezave so&nbsp;<strong>niso nevarni \u017ee po naravi.<\/strong>, vendar postanejo krhke tudi zunaj majhnih bank:<\/p><h3 class=\"wp-block-heading\" id=\"3-1-bms-desynchronization-risk\">3.1 Tveganje desinhronizacije sistema BMS<\/h3><ul class=\"wp-block-list\"><li>Sistem BMS vsakega modula je umerjen na fiksno napetostno okno.<\/li>\n\n<li>Serijske povezave se kopi\u010dijo\u00a0<strong>Drsenje v stanju polnjenja (SoC)<\/strong>ker pride do uravnote\u017eenja\u00a0<em>znotraj modulov<\/em>, ne\u00a0<em>med moduli<\/em>.<\/li>\n\n<li>Med hitrim polnjenjem\/razpraznjevanjem komunikacijske zamude pove\u010dajo neravnovesja.<\/li><\/ul><p><strong>In\u017eenirska posledica:<\/strong><\/p><blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>En modul najprej naleti na prenapetost \u2192 celoten 800Ah sistem se zaustavi ali izklopi \u2192 tveganje izpada.<\/p><\/blockquote><h3 class=\"wp-block-heading\" id=\"3-2-weakest-link-failure\">3.2 Napaka Weakest-Link<\/h3><ul class=\"wp-block-list\"><li>En okvarjen modul = odprt tokokrog v zaporednem nizu \u2192 popolna zaustavitev sistema.<\/li>\n\n<li>Pri 800Ah+ je to\u00a0<strong>ena sama to\u010dka odpovedi<\/strong>\u00a0kr\u0161enje pri\u010dakovanj glede redundance v komercialnih ESS.<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"3-3-voltage-drift-capacity-fade\">3.3 Napetostni zdrs in zmanj\u0161evanje zmogljivosti<\/h3><ul class=\"wp-block-list\"><li>Tudi enaki moduli se razli\u010dno starajo.<\/li>\n\n<li>Serijske verige lahko en modul napolnijo preve\u010d, druge pa premalo.<\/li>\n\n<li>Ponavljajo\u010de se mikroobremenitve pospe\u0161ujejo degradacijo \u2192 vi\u0161ji stro\u0161ki \u017eivljenjskega cikla.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"4-native-48v-parallel-industry-best-practice\">4. Nativni 48V vzporedni napajalnik: V panogi najbolj\u0161a praksa<\/h2><p>Za kapacitete \u2265800Ah:<\/p><blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Ohranite enotno sistemsko napetost (48 V) in jo merite le glede na zmogljivost.<\/strong><\/p><\/blockquote><p><strong>Prednosti:<\/strong><\/p><ul class=\"wp-block-list\"><li><strong>Elektri\u010dna simetrija:<\/strong>\u00a0Vsi moduli imajo enako napetost.<\/li>\n\n<li><strong>Postopna degradacija:<\/strong>\u00a0En modul brez povezave ne povzro\u010di propada banke.<\/li>\n\n<li><strong>Poenostavljena za\u0161\u010dita:<\/strong>\u00a0Zavarovanje na ravni modula in izolacija napak BMS.<\/li>\n\n<li><strong>Linearna raz\u0161irljivost:<\/strong>\u00a0Dodajanje modulov za pove\u010danje zmogljivosti brez preoblikovanja pretvornika.<\/li><\/ul><p><strong>Na terenu preizku\u0161ene aplikacije:<\/strong>&nbsp;Telekomunikacijske baterijske elektrarne, rezervne zmogljivosti podatkovnih centrov za enosmerni tok, uporabni ESS za enosmerno omre\u017eje.<\/p><h2 class=\"wp-block-heading\" id=\"5-architecture-decision-matrix-engineering-view-\">5. Matrika za odlo\u010danje o arhitekturi (in\u017eenirski pogled)<\/h2><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Zmogljivost sistema<\/th><th>Serija (12V \u2192 48V)<\/th><th>Nativno 48V vzporedno<\/th><th>Stopnja tveganja<\/th><th>Opombe<\/th><\/tr><\/thead><tbody><tr><td>\u2264200Ah Stanovanjski prostori<\/td><td>Pogojno<\/td><td>Izbirno<\/td><td>Nizka<\/td><td>Mala doma\u010da ESS<\/td><\/tr><tr><td>300-600Ah Hibridni<\/td><td>Odvra\u010da<\/td><td>Prednostno<\/td><td>Srednja<\/td><td>Industrijski\/hibridni ESS<\/td><\/tr><tr><td>\u2265800Ah Komercialni<\/td><td><strong>Ni priporo\u010dljivo<\/strong><\/td><td><strong>Najbolj\u0161a praksa<\/strong><\/td><td>Visoka \u010de serija<\/td><td>Komercialni ESS, telekomunikacije, mikrokodri\u017eni sistem za enosmerni tok<\/td><\/tr><\/tbody><\/table><\/figure><blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Ta matrika odra\u017ea&nbsp;<strong>zanesljivost v realnem svetu<\/strong>in ne le teoreti\u010dne zmogljivosti.<\/p><\/blockquote><h2 class=\"wp-block-heading\" id=\"6-reference-implementation-48v-800ah-sodium-ion-bank\">6. Referen\u010dno izvajanje: 48V 800Ah natrijevo-ionska baterija<\/h2><h3 class=\"wp-block-heading\" id=\"6-1-base-module-selection\">6.1 Izbira osnovnega modula<\/h3><ul class=\"wp-block-list\"><li>Uporabite\u00a0<strong>48V-nativni natrijevo-ionski moduli<\/strong>, razred 200-210Ah<\/li>\n\n<li>Zagotovite tovarni\u0161ko usklajeno razvr\u0161\u010danje celic za enakomernost napetosti\/impedance<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"6-2-parallel-expansion-strategy\">6.2 Strategija vzporedne \u0161iritve<\/h3><ul class=\"wp-block-list\"><li>Vse pozitivne signale priklju\u010dite na osrednjo zbiralko, vse negativne pa na drugo.<\/li>\n\n<li>Zagotovite enake dol\u017eine kablov \u2192 zmanj\u0161uje padec napetosti in tokovno neravnovesje<\/li>\n\n<li>Vsak modul ohrani neodvisno za\u0161\u010dito\/var\u010devanje<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"6-3-bms-communication-layer\">6.3 Komunikacijski sloj BMS<\/h3><ul class=\"wp-block-list\"><li>Veri\u017ena povezava RS485\/CAN<\/li>\n\n<li>Glavni sistem BMS predstavlja eno logi\u010dno enoto baterije inverterju.<\/li>\n\n<li>Omogo\u010da povpre\u010denje SoC, poro\u010danje o napakah in zgodnje opozarjanje na te\u017eave z moduli.<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"6-4-inverter-integration\">6.4 Vklju\u010ditev pretvornika<\/h3><ul class=\"wp-block-list\"><li>Konfiguracija profilov polnjenja natrijevih ionov<\/li>\n\n<li>Uveljavljanje konzervativnih omejitev napetosti<\/li>\n\n<li>Onemogo\u010dite predpostavke o zaporednih nizih v vdelani programski opremi<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"7-why-sodium-ion-excels-in-northern-european-deployments\">7. Zakaj so natrijevi ioni bolj\u0161i v severnoevropskih obratih<\/h2><ul class=\"wp-block-list\"><li><strong>Hladna odpornost:<\/strong>\u00a0&gt;80% uporabna zmogljivost pri -20 \u00b0C<\/li>\n\n<li><strong>Brez tveganja litijske prevleke<\/strong>\u00a0med polnjenjem v hladnem vremenu<\/li>\n\n<li><strong>Razre\u0161nica z visoko hitrostjo:<\/strong>\u00a0Podpira toplotne \u010drpalke, hitro polnjenje elektri\u010dnih vozil<\/li>\n\n<li><strong>Trajnostni razvoj:<\/strong>\u00a0Veliko surovin, ki niso kriti\u010dne; skladnost s predpisi EU<\/li><\/ul><blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>To so&nbsp;<strong>prednosti na ravni sistema<\/strong>, ne pa marketin\u0161ko ogla\u0161evanje.<\/p><\/blockquote><h2 class=\"wp-block-heading\" id=\"8-mechanical-thermal-design-considerations\">8. Mehanski in toplotni vidiki na\u010drtovanja<\/h2><ul class=\"wp-block-list\"><li>Napredni dejavniki oblike modula lahko:<ul class=\"wp-block-list\"><li>Izbolj\u0161ajte pretok zraka in odvajanje toplote<\/li>\n\n<li>Zmanj\u0161anje mrtvega prostora v omari<\/li><\/ul><\/li>\n\n<li>Pri izbiri zasnove je treba upo\u0161tevati\u00a0<strong>omejitve pri namestitvi<\/strong>, ne estetike.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"conclusion\">Zaklju\u010dek<\/h2><p>Izbira med zaporedno in vzporedno povezavo ni le tehni\u010dna zadeva - gre za\u00a0<strong>zmanj\u0161anje tveganja pri nalo\u017ebi<\/strong>. \u010ceprav se morda zdi, da je serijsko povezovanje paketov bli\u017enjica za manj\u0161e projekte, fizika\u00a0<strong>Sistemi 800Ah+<\/strong>\u00a0zahteva strategijo \"Parallel-First\".<\/p><p>Za integratorje, ki se usmerjajo na evropske ali severnoameri\u0161ke trge, je prehod na\u00a0<strong>Nativne 48V vzporedne arhitekture<\/strong>\u00a0z uporabo natrijevo-ionske tehnologije je najbolj odporna pot naprej. Zmanj\u0161uje tveganje \"naj\u0161ibkej\u0161e povezave\" in zagotavlja, da va\u0161 sistem ESS ostane delujo\u010d, tudi \u010de je potrebno vzdr\u017eevanje posameznega modula. V svetu komercialnega shranjevanja energije, ki je izpostavljen visokim tveganjem,\u00a0<strong>zanesljivost je edini merilo, ki je resni\u010dno pomembno. <a href=\"https:\/\/www.kmdpower.com\/sl\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Pi\u0161ite nam<\/a><\/strong> da prilagodite svojo re\u0161itev za natrijevo-ionsko baterijo.<\/p><h2 class=\"wp-block-heading\" id=\"faq\">POGOSTA VPRA\u0160ANJA<\/h2><h3 class=\"wp-block-heading\" id=\"what-is-the-maximum-number-of-modules-i-can-parallel-\">Kak\u0161no je najve\u010dje \u0161tevilo modulov, ki jih lahko vzporedno uporabljam?<\/h3><p>Na\u0161i 48-voltni natrijevo-ionski moduli podpirajo do 16 vzporednih enot (16P) v eni logi\u010dni banki. To vam omogo\u010da raz\u0161iritev do 3 360 Ah (pribli\u017eno 161 kWh), ne da bi potrebovali zunanji kompleksni krmilnik Master-BMS. Za projekte, ki presegajo 161 kWh, priporo\u010damo arhitekturo ve\u010d skladov z uporabo visokonapetostnega vozli\u0161\u010da.<\/p><h3 class=\"wp-block-heading\" id=\"-can-you-safely-build-a-48v-800ah-system-using-series-connected-12v-sodium-ion-batteries-\"><strong>Ali lahko varno zgradite 48V 800Ah sistem z uporabo zaporedno povezanih 12-voltnih natrijevih ionskih baterij?<\/strong><\/h3><p><strong>Kratek odgovor je: Ni priporo\u010dljivo za komercialno uporabo.<\/strong>&nbsp;Medtem ko je to primerno za manj\u0161e naprave DIY, pa pri 800 Ah serijsko povezane vrvice trpijo zaradi&nbsp;<strong>Odmik sistema BMS in zamik sinhronizacije<\/strong>. \u010ce pride do izpada enega 12V modula, se celoten 800Ah sistem ugasne. Za industrijsko zanesljivost vedno uporabljajte&nbsp;<strong>Nativni 48V moduli<\/strong>&nbsp;vzporedno povezani, da bi zagotovili \u010das delovanja sistema.<\/p><h3 class=\"wp-block-heading\" id=\"-why-is-native-48v-parallel-considered-the-industry-best-practice-for-ess-\"><strong>Zakaj velja \"vzporedna napetost 48 V\" za najbolj\u0161o prakso v panogi ESS?<\/strong><\/h3><p>Nativna 48V vzporedna arhitektura zagotavlja&nbsp;<strong>elektri\u010dna simetrija<\/strong>. Vsak modul v 800Ah banki deluje pri popolnoma enaki napetosti. To prepre\u010duje \"pobeg napetosti\", ki je obi\u010dajen pri zaporednih nizih, in omogo\u010da&nbsp;<strong>gracilna degradacija<\/strong>-\u010de en modul odpove, preostali del sistema \u0161e naprej brez prekinitve napaja breme.<\/p><h3 class=\"wp-block-heading\" id=\"-how-does-sodium-ion-na-handle-the-high-fault-currents-of-an-800ah-bank-\"><strong>Kako natrijevo-ionska baterija obvladuje visoke okvarne tokove 800Ah banke?<\/strong><\/h3><p>48V 800Ah banka lahko zagotovi kratkosti\u010dne tokove, ki presegajo&nbsp;<strong>10kA<\/strong>. Natrijevo-ionski moduli, zasnovani za komercialno uporabo, vklju\u010dujejo notranje varovalke in visokohitrostno za\u0161\u010dito BMS. Pri vzporedni konfiguraciji se tok porazdeli na ve\u010d vodil, kar olaj\u0161a upravljanje toplotnih obremenitev v primerjavi z enim visokonapetostnim zaporednim nizom.<\/p><h3 class=\"wp-block-heading\" id=\"-will-sodium-ion-batteries-lose-capacity-in-cold-climates-like-northern-europe-\"><strong>Ali bodo natrijevo-ionske baterije izgubile zmogljivost v hladnem podnebju, kot je severna Evropa?<\/strong><\/h3><p>Ne, to je ena od najve\u010djih prednosti natrijevih ionskih baterij. Za razliko od litija (LiFePO4), ki se pod 0 \u00b0C te\u017eko obnese, natrijevo-ionska baterija ohranja\u00a0<strong>zmogljivost nad 80% pri -20 \u00b0C<\/strong>. Odpravlja tudi nevarnost \"litijevega prevle\u010denja\", kar omogo\u010da varno polnjenje z visoko hitrostjo v mrzlih razmerah brez dragih grelnih elementov.<\/p><h3 class=\"wp-block-heading\" id=\"-is-it-possible-to-expand-an-existing-800ah-sodium-ion-bank-later-\"><strong>Ali je mogo\u010de kasneje raz\u0161iriti obstoje\u010do 800Ah natrijevo-ionsko baterijo?<\/strong><\/h3><p>Da, vendar le, \u010de uporabljate&nbsp;<strong>vzporedna arhitektura<\/strong>. Pri vzporedni postavitvi lahko na osrednjo zbiralko preprosto dodate ve\u010d 48-voltnih modulov. Ker si delijo isto sistemsko napetost, vam ni treba skrbeti za tako strogo uskladitev \"starosti nizov\" kot pri zaporedni konfiguraciji.<\/p>","protected":false},"excerpt":{"rendered":"<p>Pove\u010danje sistema natrijevih ionskih baterij nad 800 Ah pri 48 V ni ve\u010d laboratorijska vaja, temve\u010d kriti\u010dna in\u017eenirska odlo\u010ditev. Za izvajalce EPC, integratorje ESS in operaterje telekomunikacijskih\/podatkovnih centrov na trgih z visokimi standardi, kot je Nem\u010dija, ni prednostna naloga le gostota energije, temve\u010d tudi zanesljivost sistema, stro\u0161ki \u017eivljenjskega cikla in skladnost z zakonodajo. Pogosto tehni\u010dno vpra\u0161anje: \"Ali lahko zaporedno in vzporedno kombiniram natrijevo-ionsko baterijo za izgradnjo...<\/p>","protected":false},"author":1,"featured_media":4481,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5057","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts\/5057","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/comments?post=5057"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts\/5057\/revisions"}],"predecessor-version":[{"id":5058,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/posts\/5057\/revisions\/5058"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/media\/4481"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/media?parent=5057"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/categories?post=5057"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sl\/wp-json\/wp\/v2\/tags?post=5057"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}