{"id":5335,"date":"2026-11-25T05:36:02","date_gmt":"2026-11-25T05:36:02","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5335"},"modified":"2026-11-25T05:36:04","modified_gmt":"2026-11-25T05:36:04","slug":"can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sk\/news\/can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route\/","title":{"rendered":"Dok\u00e1\u017ee sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria zabezpe\u010di\u0165 prev\u00e1dzku zdv\u00edhac\u00edch plo\u0161\u00edn n\u00e1kladn\u00fdch vozidiel po\u010das celej zimnej dod\u00e1vkovej trasy?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Plne nabit\u00e1 bat\u00e9ria zdv\u00edhacieho zadn\u00e9ho v\u00fdklopu nezaru\u010duje dostatok energie na posledn\u00fa dod\u00e1vku. Opakovan\u00e9 hydraulick\u00e9 oper\u00e1cie, kr\u00e1tke jazdy a obmedzen\u00e9 nab\u00edjanie v zime ved\u00fa k kumulat\u00edvnemu \u00fabytku energie. Pre v\u00fdrobcov zdv\u00edhac\u00edch zadn\u00fdch v\u00fdklopov a spolo\u010dnosti zaoberaj\u00face sa dodato\u010dnou mont\u00e1\u017eou do vozidiel, <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">sod\u00edkov\u00e1 bat\u00e9ria<\/a><\/strong> Vhodnos\u0165 z\u00e1vis\u00ed od mno\u017estva vyu\u017eite\u013enej energie v najn\u00e1ro\u010dnej\u0161om bode trasy, dostato\u010dn\u00e9ho v\u00fdkonu motora a doplnenia energie pred nasleduj\u00facim pracovn\u00fdm d\u0148om.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Sodium-Battery-12V-100Ah-Bluetooth-Low-Temperature-Na-Ion-Battery-Supplier-Factory-Manufacturers-001.jpg\" alt=\"\" class=\"wp-image-1451\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V 100Ah sod\u00edkovo i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Pre\u010do opakovan\u00e9 zast\u00e1vky sp\u00f4sobuj\u00fa energetick\u00fd deficit zdv\u00edhac\u00edch dver\u00ed?<\/h2><p class=\"wp-block-paragraph\">Bat\u00e9ria zdv\u00edhacieho zadn\u00e9ho \u010dela nap\u00e1ja hydraulick\u00e9 zariadenia pri zast\u00e1vkach a m\u00f4\u017ee sa dob\u00edja\u0165 po\u010das jazdy. A <a href=\"https:\/\/purkeys.net\/case-study-how-purkeys-direct-helped-keep-under-charged-liftgates-off-the-road\/\" target=\"_blank\" rel=\"noreferrer noopener\">pr\u00edpad t\u00fdkaj\u00faci sa vozov\u00e9ho parku, o ktorom informoval Purkeys<\/a> opisuje situ\u00e1ciu, ke\u010f vybit\u00e1 bat\u00e9ria br\u00e1ni zdvihnutiu plo\u0161\u00edn, \u010do si vy\u017eaduje z\u00e1sah cestnej slu\u017eby. Nejde o po\u013en\u00e9 testovanie sod\u00edko-i\u00f3nov\u00fdch bat\u00e9ri\u00ed.<\/p><p class=\"wp-block-paragraph\">N\u00e1kladn\u00e9 auto m\u00f4\u017ee vylo\u017ei\u0165 nieko\u013eko paliet a za p\u00e1r min\u00fat sa dosta\u0165 k \u010fal\u0161iemu z\u00e1kazn\u00edkovi. Plne nabit\u00e1 bat\u00e9ria m\u00f4\u017ee v prv\u00fd de\u0148 zakry\u0165 nedostato\u010dn\u00e9 nabitie, ak je no\u010dn\u00e9 nab\u00edjanie v depu nedostato\u010dn\u00e9.<\/p><p class=\"wp-block-paragraph\">Zima ovplyv\u0148uje tak ponuku, ako aj dopyt po energii. Studen\u00e9 bat\u00e9rie m\u00f4\u017eu ma\u0165 menej dostupnej energie a ni\u017e\u0161ie limity nab\u00edjania. Studen\u00e1 hydraulick\u00e1 kvapalina m\u00f4\u017ee ovplyvni\u0165 prev\u00e1dzkov\u00fa dobu a spotrebu motora, v z\u00e1vislosti od typu kvapaliny, \u010derpadla a kon\u0161trukcie zariadenia. Tieto vplyvy je lep\u0161ie mera\u0165, ako uplat\u0148ova\u0165 univerz\u00e1lny zimn\u00fd korek\u010dn\u00fd faktor.<\/p><p class=\"wp-block-paragraph\">Dlh\u00e9 k\u00e1ble a pripojenia m\u00f4\u017eu zn\u00ed\u017ei\u0165 nab\u00edjacie nap\u00e4tie. \u0160peci\u00e1lna nab\u00edja\u010dka DC-DC v zadn\u00fdch dver\u00e1ch m\u00f4\u017ee t\u00fato stratu kompenzova\u0165, jej pr\u00edtomnos\u0165 v\u0161ak nezaru\u010duje kompatibilitu so sod\u00edkovo-i\u00f3nov\u00fdmi bat\u00e9riami.<\/p><h2 class=\"wp-block-heading\">Ko\u013eko energie spotrebuje nalo\u017een\u00e1 doru\u010dovacia trasa?<\/h2><p class=\"wp-block-paragraph\">Menovit\u00fd v\u00fdkon uveden\u00fd na typovom \u0161t\u00edtku motora neur\u010duje denn\u00fa spotrebu energie. Spotrebu ovplyv\u0148uje hmotnos\u0165 n\u00e1kladu, v\u00fd\u0161ka zdvihu, \u00fa\u010dinnos\u0165 hydraulick\u00e9ho syst\u00e9mu a d\u013a\u017eka prev\u00e1dzky, rovnako ako to, \u010di sa zdv\u00edhanie vykon\u00e1va pomocou pohonu alebo s vyu\u017eit\u00edm gravit\u00e1cie.<\/p><p class=\"wp-block-paragraph\">Zmerajte nap\u00e4tie a pr\u00fad na svork\u00e1ch bat\u00e9rie po\u010das typick\u00fdch prev\u00e1dzkov\u00fdch cyklov zdv\u00edhac\u00edch dver\u00ed. Elektrick\u00e1 energia spotrebovan\u00e1 po\u010das jedn\u00e9ho cyklu je:<\/p><p class=\"wp-block-paragraph\"><strong>Energia cyklu (Wh) = integr\u00e1l V(t) \u00d7 I(t) v \u010dase \u00f7 3 600<\/strong><\/p><p class=\"wp-block-paragraph\">Nap\u00e4tie sa meria vo voltoch, pr\u00fad v amp\u00e9roch a \u010das v sekund\u00e1ch.<\/p><p class=\"wp-block-paragraph\">Zaznamen\u00e1vajte samostatne jazdy s n\u00e1kladom, jazdy bez n\u00e1kladu, spiato\u010dn\u00e9 jazdy a \u010dakanie, vr\u00e1tane mimoriadne n\u00e1ro\u010dn\u00fdch zast\u00e1vok. Spiato\u010dn\u00e9 jazdy nepo\u010d\u00edtajte dvakr\u00e1t, ak s\u00fa u\u017e zahrnut\u00e9 v kompletnom cykle.<\/p><p class=\"wp-block-paragraph\">Nasleduj\u00faca hypotetick\u00e1 trasa ilustruje tento v\u00fdpo\u010det. Pre lep\u0161iu predstavu je <a href=\"https:\/\/www.maxonlift.com\/sites\/default\/files\/manuals\/2017-01\/operators-handbook-gpc-x1-ld-gpc-x1-ldf-20908422_2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">N\u00e1vod na obsluhu zariadenia MAXON GPC X1-LD\/LDF, strana 5<\/a> uv\u00e1dza hodnotu 150 A pri 12 V a pre pr\u00edklad s nosnos\u0165ou 600 kg odpor\u00fa\u010da bat\u00e9riu s kapacitou 88 Ah. Pri 12 V a 150 A spotrebuje 36 sek\u00fand ekvivalentnej prev\u00e1dzky 18 Wh. Ide o ilustr\u00e1ciu r\u00e1dovej ve\u013ekosti, nie o nameran\u00fd cyklus ani o tvrdenie, \u017ee pr\u00fad zost\u00e1va kon\u0161tantn\u00fd.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter trasovej energie<\/th><th class=\"has-text-align-right\" data-align=\"right\">Ilustra\u010dn\u00e1 hodnota<\/th><\/tr><\/thead><tbody><tr><td>Kompletn\u00e9 cykly zdvihnutia a vr\u00e1tenia<\/td><td class=\"has-text-align-right\" data-align=\"right\">30<\/td><\/tr><tr><td>Priemern\u00e1 spotreba energie na jeden cyklus<\/td><td class=\"has-text-align-right\" data-align=\"right\">18 Wh<\/td><\/tr><tr><td>Energia potrebn\u00e1 na prev\u00e1dzku zdv\u00edhacej plo\u0161iny<\/td><td class=\"has-text-align-right\" data-align=\"right\">540 Wh<\/td><\/tr><tr><td>Spotreba regul\u00e1tora a spotreba v pohotovostnom re\u017eime<\/td><td class=\"has-text-align-right\" data-align=\"right\">60 Wh<\/td><\/tr><tr><td>Celkov\u00e1 spotreba energie na svork\u00e1ch bat\u00e9rie<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Skuto\u010dn\u00e1 doba nab\u00edjania vozidla<\/td><td class=\"has-text-align-right\" data-align=\"right\">2 hodiny<\/td><\/tr><tr><td>Priemern\u00fd prijat\u00fd nab\u00edjac\u00ed v\u00fdkon<\/td><td class=\"has-text-align-right\" data-align=\"right\">120 W<\/td><\/tr><tr><td>Energia dod\u00e1van\u00e1 na svorky bat\u00e9rie<\/td><td class=\"has-text-align-right\" data-align=\"right\">240 Wh<\/td><\/tr><tr><td>Denn\u00fd deficit energie v termin\u00e1li<\/td><td class=\"has-text-align-right\" data-align=\"right\">360 Wh<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Vozidlo obnovuje iba 40% spotrebovanej energie. Zost\u00e1vaj\u00facich 360 Wh sa mus\u00ed \u010derpa\u0165 z existuj\u00faceho akumul\u00e1tora, pri\u010dom je potrebn\u00e9 zoh\u013eadni\u0165 aj vn\u00fatorn\u00e9 straty bat\u00e9rie. P\u00e4\u0165 identick\u00fdch pracovn\u00fdch dn\u00ed bez dodato\u010dn\u00e9ho nab\u00edjania by viedlo k kumulat\u00edvnemu kone\u010dn\u00e9mu energetick\u00e9mu deficitu vo v\u00fd\u0161ke 1 800 Wh.<\/p><p class=\"wp-block-paragraph\">Energetick\u00e1 dostato\u010dnos\u0165 nie je to ist\u00e9 ako kompatibilita s motorom. Technick\u00e1 \u0161pecifik\u00e1cia produktu Kamada Power 12 V\/100 Ah uv\u00e1dza maxim\u00e1lny trval\u00fd v\u00fdboj 100 A a impulz 150 A trvaj\u00faci menej ako 3 milisekundy. Tieto hodnoty neznamenaj\u00fa, \u017ee jeden akumul\u00e1torov\u00fd blok je vhodn\u00fd na zdvih s pr\u00fadom 150 A trvaj\u00faci nieko\u013eko sek\u00fand. Porovnajte profil pr\u00fadu a trvania motora, vr\u00e1tane \u0161tartovacieho n\u00e1behu, op\u00e4tovn\u00fdch \u0161tartov pod za\u0165a\u017een\u00edm a tepeln\u00fdch limitov pri opakovan\u00fdch cykloch, so schv\u00e1len\u00fdmi limitmi akumul\u00e1torov\u00e9ho modulu pri o\u010dak\u00e1vanej teplote. Overte minim\u00e1lne nap\u00e4tie na svork\u00e1ch motora. Nadmern\u00fd pokles nap\u00e4tia v k\u00e1bli alebo odpojenie syst\u00e9mu riadenia bat\u00e9rie (BMS) m\u00f4\u017ee preru\u0161i\u0165 prev\u00e1dzku aj v pr\u00edpade, \u017ee v akumul\u00e1tore zost\u00e1va ulo\u017een\u00e1 energia. Ochrann\u00e9 odpojenie pri 8 V uveden\u00e9 v danom odkaze nie je \u0161tandardne prijate\u013en\u00fdm prev\u00e1dzkov\u00fdm nap\u00e4t\u00edm motora.<\/p><h2 class=\"wp-block-heading\">M\u00f4\u017ee \u010das str\u00e1ven\u00fd jazdou v zime nahradi\u0165 energiu spotrebovan\u00fa pri ka\u017edom zastaven\u00ed?<\/h2><p class=\"wp-block-paragraph\">Nab\u00edja\u010dka typu DC-DC s menovit\u00fdm pr\u00fadom 40 A nemus\u00ed po\u010das zimnej cesty nevyhnutne dod\u00e1va\u0165 do bat\u00e9rie zadn\u00fdch dver\u00ed 40 A. Prijate\u013en\u00fd nab\u00edjac\u00ed pr\u00fad z\u00e1vis\u00ed od elektrick\u00e9ho nap\u00e1jania vozidla, v\u00fdstupn\u00fdch charakterist\u00edk nab\u00edja\u010dky, teploty bat\u00e9rie a stavu nabitia (SOC), ako aj od limitov stanoven\u00fdch pre dan\u00fa bat\u00e9riu.<\/p><p class=\"wp-block-paragraph\">Energia dodan\u00e1 po\u010das ka\u017ed\u00e9ho jazdn\u00e9ho intervalu je:<\/p><p class=\"wp-block-paragraph\"><strong>Energia nabitia (Wh) = integr\u00e1l Vcharge(t) \u00d7 Iaccepted(t) v \u010dase \u00f7 3 600<\/strong><\/p><p class=\"wp-block-paragraph\">Pou\u017eite skuto\u010dn\u00fd pr\u00fad, ktor\u00fd bat\u00e9ria prij\u00edma, a nie maxim\u00e1lnu menovit\u00fa hodnotu uveden\u00fa na \u0161t\u00edtku nab\u00edja\u010dky. Ak s\u00fa po\u010das jazdy akt\u00edvne pomocn\u00e9 spotrebi\u010de, zoh\u013eadnite ich samostatne alebo d\u00f4sledne pou\u017e\u00edvajte \u010dist\u00fd v\u00fdkon na svork\u00e1ch bat\u00e9rie.<\/p><p class=\"wp-block-paragraph\">Predpokladajme hypotetick\u00e9 nab\u00edjacie nap\u00e4tie 13,5 V a 15-min\u00fatov\u00fd interval jazdy. Pri 10 A sa do bat\u00e9rie nabije 33,75 Wh. Pri 20 A sa nabije 67,5 Wh. Pri 40 A sa nabije 135 Wh. Tieto hodnoty predpokladaj\u00fa kon\u0161tantn\u00e9 nap\u00e4tie a pr\u00fad a nezoh\u013ead\u0148uj\u00fa vn\u00fatorn\u00e9 straty pri ukladan\u00ed energie. Nejedn\u00e1 sa o \u0161pecifik\u00e1cie nab\u00edjacieho pr\u00fadu pre bat\u00e9rie Kamada Power.<\/p><p class=\"wp-block-paragraph\">Pre lep\u0161iu orient\u00e1ciu: v technickej pr\u00edru\u010dke pre 12 V\/100 Ah s\u00fa uveden\u00e9 hodnoty 10 A v rozmedz\u00ed od \u221220 \u00b0C do \u221210 \u00b0C a 20 A v rozmedz\u00ed od \u221210 \u00b0C do 0 \u00b0C. Tieto limity sa l\u00ed\u0161ia v z\u00e1vislosti od rev\u00edzie. Referen\u010dn\u00fd dokument popisuje \u0161tandardn\u00e9 nab\u00edjanie v re\u017eime CC\/CV pri teplot\u00e1ch 0\u201345 \u00b0C; hodnoty nap\u00e4tia, pr\u00fadu, ukon\u010denia nab\u00edjania a teplotn\u00e9 hranice pri teplot\u00e1ch pod bodom mrazu, ako aj spr\u00e1vanie syst\u00e9mu BMS je potrebn\u00e9 overi\u0165 samostatne. Ani v\u00fdkonnej\u0161ia nab\u00edja\u010dka nem\u00f4\u017ee tieto limity prekro\u010di\u0165. Be\u017en\u00e1 regul\u00e1cia pr\u00fadu by tie\u017e nemala z\u00e1visie\u0165 od ochrann\u00fdch vypnut\u00ed syst\u00e9mu BMS. <a href=\"https:\/\/www.purkeys.net\/wp-content\/uploads\/2018\/07\/Direct-01-Installation-Guide.pdf\" target=\"_blank\" rel=\"noopener\">N\u00e1vod na in\u0161tal\u00e1ciu zariadenia Purkeys Direct<\/a> opisuje zv\u00fd\u0161enie nab\u00edjacieho nap\u00e4tia v chladnom po\u010das\u00ed. Existuj\u00faci profil teplotnej kompenz\u00e1cie oloven\u00fdch bat\u00e9ri\u00ed je preto potrebn\u00e9 porovna\u0165 so schv\u00e1len\u00fdmi limitmi nap\u00e4tia a pr\u00fadu sod\u00edko-i\u00f3nov\u00e9ho akumul\u00e1tora; referen\u010dn\u00e1 maxim\u00e1lna hodnota 15,6 V predstavuje horn\u00fa hranicu, nie univerz\u00e1lnu nastaven\u00fa hodnotu nab\u00edjania.<\/p><p class=\"wp-block-paragraph\">Akumul\u00e1torov\u00fd blok schv\u00e1len\u00fd pre nab\u00edjanie pri teplot\u00e1ch pod bodom mrazu m\u00f4\u017ee predstavova\u0165 alternat\u00edvu k syst\u00e9mom, ktor\u00e9 obmedzuj\u00fa nab\u00edjanie pri teplot\u00e1ch pod bodom mrazu, za predpokladu, \u017ee s\u00fa splnen\u00e9 po\u017eiadavky na pr\u00fad motora a nap\u00e4tie. Samotn\u00fd v\u00fdskum \u010dl\u00e1nkov nedok\u00e1\u017ee stanovi\u0165 limity nab\u00edjania hotov\u00e9ho akumul\u00e1torov\u00e9ho bloku ani mieru sp\u00e4tn\u00e9ho z\u00edskavania energie v zimnom obdob\u00ed.<\/p><p class=\"wp-block-paragraph\">O platnom limite nab\u00edjania rozhoduje teplota bat\u00e9rie, nie teplota okolia. Akumul\u00e1torov\u00e1 s\u00fastava namontovan\u00e1 na pr\u00edvesu m\u00f4\u017ee zosta\u0165 studen\u00e1 aj po zahriat\u00ed motora, \u010do obmedzuje dob\u00edjanie po\u010das kr\u00e1tkych ciest.<\/p><p class=\"wp-block-paragraph\">P\u00e4\u0165min\u00fatov\u00fd interval jazdy pri v\u00fdkone 120 W dod\u00e1 len 10 Wh. Ak predch\u00e1dzaj\u00faca prev\u00e1dzka zadn\u00fdch dver\u00ed spotrebovala 18 Wh, do \u010fal\u0161ieho intervalu sa prenesie \u010fal\u0161\u00ed deficit energie vo v\u00fd\u0161ke 8 Wh, a to e\u0161te pred zoh\u013eadnen\u00edm str\u00e1t pri ukladan\u00ed energie. Dlh\u0161ie intervaly jazdy nesk\u00f4r v priebehu d\u0148a m\u00f4\u017eu tento deficit vyrovna\u0165, nem\u00f4\u017eu v\u0161ak pom\u00f4c\u0165 pri dod\u00e1vke, ktor\u00e1 prebieha pred t\u00fdmito intervalmi.<\/p><h2 class=\"wp-block-heading\">Kde dosahuje trasa najni\u017e\u0161iu \u00farove\u0148 energetick\u00fdch rezerv?<\/h2><p class=\"wp-block-paragraph\">Trasy s rovnakou dennou spotrebou, vstupn\u00fdm v\u00fdkonom nab\u00edjania a kone\u010dnou rezervou m\u00f4\u017eu ma\u0165 odli\u0161n\u00e9 minim\u00e1lne energetick\u00e9 po\u017eiadavky, preto\u017ee dod\u00e1vky a nab\u00edjanie prebiehaj\u00fa v r\u00f4znom porad\u00ed.<\/p><p class=\"wp-block-paragraph\">Vr\u00e1\u0165me sa k hypotetickej trase so spotrebou 600 Wh a pr\u00edjmom 240 Wh nab\u00edjacej energie. Predpokladajme, \u017ee na za\u010diatku je k dispoz\u00edcii 800 Wh ulo\u017eenej energie. Rozde\u013eme spotrebu na tri bloky dod\u00e1vky po 200 Wh, vr\u00e1tane pridelen\u00e9ho odberu v pohotovostnom re\u017eime, a dod\u00e1vku energie na nab\u00edjanie na dva bloky po 120 Wh. Pre toto zjednodu\u0161en\u00e9 porovnanie predpokladajme, \u017ee energia na nab\u00edjanie je plne vyu\u017eite\u013en\u00e1, teplota je kon\u0161tantn\u00e1 a ani jeden z blokov nab\u00edjania nenaraz\u00ed na plne nabit\u00fa bat\u00e9riu.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Prev\u00e1dzkov\u00e1 f\u00e1za<\/th><th class=\"has-text-align-right\" data-align=\"right\">Trasa A \u2014 Rozvoz po jednotliv\u00fdch adres\u00e1ch<\/th><th class=\"has-text-align-right\" data-align=\"right\">Trasa B \u2014 S\u00fastreden\u00e9 dod\u00e1vky<\/th><\/tr><\/thead><tbody><tr><td>Odchod<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><\/tr><tr><td>Prv\u00fd dod\u00e1vkov\u00fd blok<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>\u010eal\u0161ie podujatie<\/td><td class=\"has-text-align-right\" data-align=\"right\">720 Wh (kapacita)<\/td><td class=\"has-text-align-right\" data-align=\"right\">400 Wh (v\u00fdkon)<\/td><\/tr><tr><td>\u010eal\u0161ie podujatie<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (v\u00fdkon)<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (kapacita)<\/td><\/tr><tr><td>\u010eal\u0161\u00ed nab\u00edjac\u00ed blok<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><\/tr><tr><td>Z\u00e1vere\u010dn\u00fd dodac\u00ed blok<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><\/tr><tr><td>Minim\u00e1lna zost\u00e1vaj\u00faca energia<\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>440 Wh<\/strong><\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>400 Wh<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png\" alt=\"\" class=\"wp-image-5338\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Obe trasy kon\u010dia s hodnotou 440 Wh. Trasa B v\u0161ak dosiahne najni\u017e\u0161iu rezervu e\u0161te pred prvou mo\u017enos\u0165ou v\u00fdraznej\u0161ieho dobitia. Pri predpokladanej minim\u00e1lnej prev\u00e1dzkovej rezervy 420 Wh trasa A spl\u0148uje energetick\u00e9 po\u017eiadavky, zatia\u013e \u010do trasa B ich nesp\u013a\u0148a.<\/p><p class=\"wp-block-paragraph\">V pr\u00edpade zjednodu\u0161en\u00e9ho modelu s kon\u0161tantnou teplotou a bez str\u00e1t:<\/p><p class=\"wp-block-paragraph\"><strong>Po\u017eadovan\u00e1 po\u010diato\u010dn\u00e1 vyu\u017eite\u013en\u00e1 energia \u2265 maxim\u00e1lny kumulat\u00edvny deficit energie na trase + po\u017eadovan\u00e1 prev\u00e1dzkov\u00e1 rezerva.<\/strong><\/p><p class=\"wp-block-paragraph\">Za uveden\u00fdch pr\u00edkladov\u00fdch podmienok je maxim\u00e1lny kumulat\u00edvny deficit 360 Wh pre trasu A a 400 Wh pre trasu B. Udr\u017eiavanie rezervy 420 Wh si vy\u017eaduje aspo\u0148 780 Wh, resp. 820 Wh po\u010diato\u010dnej vyu\u017eite\u013enej energie. Rezerva 420 Wh je len ilustrat\u00edvna, nie je to v\u0161eobecn\u00e9 odpor\u00fa\u010danie. Skuto\u010dn\u00fa rezervu stanovte na z\u00e1klade nevyhnutn\u00fdch zost\u00e1vaj\u00facich zdvihov\u00fdch cyklov, neo\u010dak\u00e1van\u00fdch dod\u00e1vok, starnutia a neistoty spojenej s chladn\u00fdm po\u010das\u00edm; nap\u00e4tie pri za\u0165a\u017een\u00ed overte samostatne.<\/p><p class=\"wp-block-paragraph\">V praxi sledujte dostupn\u00fa energiu po ka\u017edom dodan\u00ed a nab\u00edjacom cykle. Dopl\u0148ujte z\u00e1soby len do v\u00fd\u0161ky dostupnej vo\u013enej kapacity akumul\u00e1tora a zoh\u013ead\u0148ujte vn\u00fatorn\u00e9 straty. Pri zmene prev\u00e1dzkovej teploty prehodno\u0165te mno\u017estvo dostupnej energie.<\/p><h2 class=\"wp-block-heading\">Kedy je moderniz\u00e1cia nab\u00edjacieho syst\u00e9mu efekt\u00edvnej\u0161ia ako v\u00fdmena bat\u00e9rie?<\/h2><p class=\"wp-block-paragraph\">Pre v\u00fdrobcov OEM, ktor\u00ed posudzuj\u00fa <a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 100Ah sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria<\/a>, konfigur\u00e1cie zapojenia do paraleln\u00e9ho zapojenia schv\u00e1len\u00e9 v\u00fdrobcom pon\u00fakaj\u00fa mo\u017enos\u0165 zv\u00fd\u0161i\u0165 kapacitu akumul\u00e1tora. Na pr\u00edklade kon\u0161trukcie s menovit\u00fdm nap\u00e4t\u00edm 12 V konfigur\u00e1cie 1P, 2P, 3P a 4P zodpovedaj\u00fa kapacit\u00e1m 100 Ah, 200 Ah, 300 Ah a 400 Ah, resp. 1 200 Wh, 2 400 Wh, 3 600 Wh a 4 800 Wh. Ide o nomin\u00e1lne v\u00fdpo\u010dty, nie o nameran\u00fa vyu\u017eite\u013en\u00fa energiu. V katal\u00f3gu, na ktor\u00fd odkazuje tento odkaz, je uveden\u00fd model s nap\u00e4t\u00edm 12,8 V; technick\u00e1 \u0161pecifik\u00e1cia 12 V pou\u017eit\u00e1 v tomto texte sa nesmie bez potvrdenia pova\u017eova\u0165 za rovnak\u00fa verziu. Pred schv\u00e1len\u00edm n\u00e1vrhu si zistite presn\u00e9 SKU a schv\u00e1len\u00e9 limity.<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png\" alt=\"\" class=\"wp-image-5336\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Ak jeden akumul\u00e1tor nedok\u00e1\u017ee doda\u0165 po\u017eadovan\u00fdch 820 Wh pre koncentrovan\u00fa trasu, zv\u00e1\u017ete pou\u017eitie v\u00e4\u010d\u0161ej schv\u00e1lenej konfigur\u00e1cie. Ur\u010dite dostupn\u00fa energiu pri o\u010dak\u00e1vanej teplote a prev\u00e1dzkovom nap\u00e4t\u00ed zariadenia, a nie len na z\u00e1klade menovitej kapacity.<\/p><p class=\"wp-block-paragraph\">Pri dostato\u010dnom no\u010dnom nab\u00edjan\u00ed v depu dok\u00e1\u017ee v\u00e4\u010d\u0161ia bat\u00e9ria pokry\u0165 s\u00fastreden\u00e9 dod\u00e1vky bez potreby nab\u00edja\u010dky s vy\u0161\u0161\u00edm v\u00fdkonom.<\/p><p class=\"wp-block-paragraph\">Bez no\u010dn\u00e9ho nab\u00edjania dodato\u010dn\u00e1 kapacita iba oddiali opakuj\u00faci sa denn\u00fd deficit 360 Wh.<\/p><p class=\"wp-block-paragraph\">V pr\u00edpade uvedenej trasy si vyrovnanie dennej spotreby termin\u00e1lu vo v\u00fd\u0161ke 600 Wh po\u010das dvoch hod\u00edn efekt\u00edvneho nab\u00edjania vy\u017eaduje priemern\u00fd pr\u00edkon minim\u00e1lne 300 W. Pri ilustrat\u00edvnom nab\u00edjacom nap\u00e4t\u00ed 13,5 V to predstavuje pribli\u017ene 22,2 A prijate\u013en\u00e9ho pr\u00fadu, a to e\u0161te pred zoh\u013eadnen\u00edm vn\u00fatorn\u00fdch str\u00e1t v akumul\u00e1tore. Pri 13,5 V jeden akumul\u00e1torov\u00fd blok s obmedzen\u00edm na 10 A alebo 20 A prijme za dve hodiny len 270 Wh alebo 540 Wh, \u010do znamen\u00e1 deficit 330 Wh alebo 60 Wh e\u0161te pred zoh\u013eadnen\u00edm str\u00e1t. Zoh\u013eadnite schv\u00e1len\u00fa kapacitu paraleln\u00e9ho nab\u00edjania, dlh\u0161ie intervaly nab\u00edjania alebo nab\u00edjanie v depu; v\u00e4\u010d\u0161ia nab\u00edja\u010dka sama o sebe nedok\u00e1\u017ee prekona\u0165 obmedzenia akumul\u00e1torov\u00e9ho modulu.<\/p><p class=\"wp-block-paragraph\">Rozhodnutie o verejnom obstar\u00e1van\u00ed sa riadi \u0161tyrmi podmienkami:<\/p><ul class=\"wp-block-list\"><li><strong>Do\u010dasn\u00fd nedostatok energie:<\/strong> Zv\u00e4\u010d\u0161ite vyu\u017eite\u013en\u00fd \u00falo\u017en\u00fd priestor alebo presu\u0148te dostupn\u00fa mo\u017enos\u0165 nab\u00edjania tak, aby predch\u00e1dzala n\u00e1ro\u010dn\u00e9mu zoskupeniu dod\u00e1vok.<\/li>\n\n<li><strong>Opakovan\u00e9 \u00fa\u010dtovanie ni\u017e\u0161ej sumy:<\/strong> Zlep\u0161i\u0165 kompatibiln\u00e9 dopl\u0148ovanie paliva prostredn\u00edctvom nab\u00edjania vozidiel alebo v dep\u00e1ch.<\/li>\n\n<li><strong>Obe podmienky:<\/strong> Porovnajte celkov\u00e9 po\u017eiadavky na \u00falo\u017en\u00fd priestor a nab\u00edjanie pomocou chronologick\u00e9ho z\u00e1znamu trasy.<\/li>\n\n<li><strong>Nezlu\u010dite\u013enos\u0165 motora alebo nap\u00e4tia:<\/strong> Odmietnite priamu n\u00e1hradu a zv\u00e1\u017ete pou\u017eitie samostatne vyvinutej OEM platformy.<\/li><\/ul><p class=\"wp-block-paragraph\">Pri prev\u00e1dzkovom za\u0165a\u017een\u00ed 150 A predstavuje ide\u00e1lne rozdelenie medzi konfigur\u00e1cie 1P, 2P, 3P a 4P hodnoty 150 A, 75 A, 50 A a 37,5 A na jeden blok. Pri referen\u010dnom limite 100 A v nepretr\u017eitom re\u017eime 1P nesp\u013a\u0148a tento po\u010diato\u010dn\u00fd test trval\u00e9ho pr\u00fadu; 2P\u20134P si zasl\u00fa\u017eia hodnotenie, nie automatick\u00e9 schv\u00e1lenie. Ak sa jedna vetva odpoj\u00ed, 2P skupina by mohla necha\u0165 zost\u00e1vaj\u00faci bal\u00edk nies\u0165 150 A. Je potrebn\u00e9 stanovi\u0165 skuto\u010dn\u00e9 rozdelenie za\u0165a\u017eenia, limity pri n\u00edzkych teplot\u00e1ch, ochranu vetiev a spr\u00e1vanie pri bezpe\u010dnom vypnut\u00ed. Ak schv\u00e1len\u00e9 paraleln\u00e9 zapojenia nesp\u013a\u0148aj\u00fa po\u017eiadavky motora alebo nab\u00edjania, zv\u00e1\u017ete pou\u017eitie vysokov\u00fdkonn\u00e9ho OEM modulu namiesto ob\u00eddenia ochrany. Dodato\u010dn\u00e9 \u00fapravy musia sp\u013a\u0148a\u0165 elektrick\u00e9 po\u017eiadavky a podmienky schv\u00e1lenia v\u00fdrobcov vozidiel a zdv\u00edhac\u00edch dver\u00ed.<\/p><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png\" alt=\"\" class=\"wp-image-5337\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><h2 class=\"wp-block-heading\">\u010cASTO KLADEN\u00c9 OT\u00c1ZKY<\/h2><h3 class=\"wp-block-heading\">Dok\u00e1\u017ee akumul\u00e1tor s kapacitou 100 Ah poh\u00e1\u0148a\u0165 zdv\u00edhacie dvere?<\/h3><p class=\"wp-block-paragraph\">Je to mo\u017en\u00e9. Hotov\u00e1 sod\u00edko-i\u00f3nov\u00e1 bat\u00e9ria s kapacitou 100 Ah mus\u00ed sp\u013a\u0148a\u0165 po\u017eiadavky na pr\u00fad a dobu prev\u00e1dzky hydraulick\u00e9ho motora, limity nap\u00e4tia pri za\u0165a\u017een\u00ed a maxim\u00e1lny kumulat\u00edvny deficit energie na trase. Ak jeden akumul\u00e1torov\u00fd blok nesta\u010d\u00ed, je mo\u017en\u00e9 zv\u00e1\u017ei\u0165 paraleln\u00e9 zapojenie schv\u00e1len\u00e9 v\u00fdrobcom alebo bat\u00e9riu OEM navrhnut\u00fa nez\u00e1visl\u00fdm dod\u00e1vate\u013eom. Nomin\u00e1lna kapacita nezaru\u010duje priamu kompatibilitu pri v\u00fdmene.<\/p><h3 class=\"wp-block-heading\">Vyrie\u0161ia dve bat\u00e9rie probl\u00e9m s kr\u00e1tkymi dojazdmi?<\/h3><p class=\"wp-block-paragraph\">Dve schv\u00e1len\u00e9 paralelne zapojen\u00e9 bat\u00e9rie m\u00f4\u017eu poskytn\u00fa\u0165 v\u00e4\u010d\u0161iu prev\u00e1dzkov\u00fa rezervu medzi jednotliv\u00fdmi nab\u00edjaniami. Nemusia v\u0161ak nevyhnutne zv\u00fd\u0161i\u0165 mno\u017estvo energie obnoven\u00e9 po\u010das kr\u00e1tkych j\u00e1zd. Ak denn\u00e1 spotreba na\u010falej prevy\u0161uje mno\u017estvo obnovenej energie, je na\u010falej potrebn\u00e9 kompatibiln\u00e9 vylep\u0161enie nab\u00edjacieho syst\u00e9mu alebo dodato\u010dn\u00e9 nab\u00edjanie v depu.<\/p><h3 class=\"wp-block-heading\">Potrebuje nab\u00edja\u010dka DC\/DC profil pre sod\u00edkov\u00e9 i\u00f3nov\u00e9 bat\u00e9rie?<\/h3><p class=\"wp-block-paragraph\">Nab\u00edja\u010dka mus\u00ed sp\u013a\u0148a\u0165 po\u017eiadavky vybranej bat\u00e9rie, pokia\u013e ide o nap\u00e4tie, pr\u00fad, teplotu a ukon\u010denie nab\u00edjania. Vhodn\u00fd m\u00f4\u017ee by\u0165 \u0161peci\u00e1lny profil pre sod\u00edko-i\u00f3nov\u00e9 bat\u00e9rie, av\u0161ak samotn\u00fd n\u00e1zov e\u0161te nezaru\u010duje kompatibilitu. Existuj\u00face nastavenia pre oloven\u00e9 alebo l\u00edtium-i\u00f3nov\u00e9 bat\u00e9rie by sa mali pou\u017e\u00edva\u0165 len vtedy, ak je ich skuto\u010dn\u00e9 spr\u00e1vanie schv\u00e1len\u00e9 pre konkr\u00e9tnu konfigur\u00e1ciu bat\u00e9rie a zariadenia.<\/p><h2 class=\"wp-block-heading\">Z\u00e1ver<\/h2><p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sod\u00edkovo-i\u00f3nov\u00e9 bat\u00e9rie<\/a><\/strong> s\u00fa vhodn\u00fdmi kandid\u00e1tmi na pou\u017eitie v syst\u00e9moch zimn\u00fdch zdv\u00edhac\u00edch plo\u0161\u00edn n\u00e1kladn\u00fdch vozidiel, ak ich vyu\u017eite\u013en\u00e1 energia, pr\u00fadov\u00e1 za\u0165a\u017eite\u013enos\u0165 motora, prev\u00e1dzkov\u00e9 nap\u00e4tie a teplotne z\u00e1visl\u00e9 limity nab\u00edjania zodpovedaj\u00fa pracovn\u00e9mu cyklu dod\u00e1vok. Maxim\u00e1lny kumulat\u00edvny deficit trasy ur\u010duje potrebn\u00fa po\u010diato\u010dn\u00fa energiu, zatia\u013e \u010do denn\u00e1 bilancia dob\u00edjania ur\u010duje, \u010di syst\u00e9m dok\u00e1\u017ee vydr\u017ea\u0165 po sebe id\u00face pracovn\u00e9 dni. Pre \u0161tandardn\u00e9 <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 100Ah sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong>, schv\u00e1len\u00e9 paraleln\u00e9 konfigur\u00e1cie alebo mo\u017en\u00e9 vlastn\u00e9 kon\u0161trukcie bat\u00e9ri\u00ed pre zdv\u00edhacie dvere, <a href=\"https:\/\/www.kmdpower.com\/sk\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">kontaktujte spolo\u010dnos\u0165 Kamada Power<\/a> spolu s inform\u00e1ciami o va\u0161ej najdlh\u0161ej zimnej dod\u00e1vkovej trase, priebehu pr\u00fadu hydraulick\u00e9ho motora, \u0161pecifik\u00e1ci\u00e1ch nab\u00edjania vozidla a predpokladanom teplotnom rozsahu bat\u00e9rie, aby sme mohli prerokova\u0165 architekt\u00faru bat\u00e9rie a nab\u00edjania \u0161pecifick\u00fa pre dan\u00fa aplik\u00e1ciu.<\/p>","protected":false},"excerpt":{"rendered":"<p>Plne nabit\u00e1 bat\u00e9ria zdv\u00edhacieho zadn\u00e9ho v\u00fdklopu nezaru\u010duje dostatok energie na posledn\u00fa dod\u00e1vku. Opakovan\u00e9 hydraulick\u00e9 oper\u00e1cie, kr\u00e1tke jazdy a obmedzen\u00e9 nab\u00edjanie v zime ved\u00fa k kumulat\u00edvnemu nedostatku energie. Pre v\u00fdrobcov zdv\u00edhac\u00edch zadn\u00fdch v\u00fdklopov (OEM) a spolo\u010dnosti zaoberaj\u00face sa dodato\u010dnou mont\u00e1\u017eou do vozidiel z\u00e1vis\u00ed vhodnos\u0165 sod\u00edkov\u00fdch bat\u00e9ri\u00ed od vyu\u017eite\u013enej energie v najn\u00e1ro\u010dnej\u0161om bode trasy, dostato\u010dn\u00e9ho v\u00fdkonu motora a doplnenia energie pred nasleduj\u00facou pracovnou...<\/p>","protected":false},"author":1,"featured_media":1451,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/comments?post=5335"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5335\/revisions"}],"predecessor-version":[{"id":5339,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5335\/revisions\/5339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media\/1451"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media?parent=5335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/categories?post=5335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/tags?post=5335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}