{"id":5308,"date":"2026-11-18T07:14:46","date_gmt":"2026-11-18T07:14:46","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5308"},"modified":"2026-11-18T07:33:08","modified_gmt":"2026-11-18T07:33:08","slug":"can-an-all-in-one-solar-poe-switch-charge-a-sodium-ion-battery-using-its-lifepo4-defaults","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sk\/news\/can-an-all-in-one-solar-poe-switch-charge-a-sodium-ion-battery-using-its-lifepo4-defaults\/","title":{"rendered":"M\u00f4\u017ee sol\u00e1rny PoE prep\u00edna\u010d typu \u201ev\u0161etko v jednom\u201c nab\u00edja\u0165 sod\u00edko-i\u00f3nov\u00fa bat\u00e9riu pomocou svojich predvolen\u00fdch nastaven\u00ed pre LiFePO4?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">V\u00fdrobca OEM vyr\u00e1ba sol\u00e1rnu kamerov\u00fa skri\u0148u na b\u00e1ze all-in-one PoE prep\u00edna\u010da, ktor\u00fd nab\u00edja bat\u00e9riu a nap\u00e1ja kamery. Prep\u00edna\u010d sa dod\u00e1va s prednastavenou bat\u00e9riou typu LiFePO4; v\u00fdrobca OEM chce nain\u0161talova\u0165 sod\u00edko-i\u00f3nov\u00fa bat\u00e9riu triedy 12 V. <strong>Nomin\u00e1lne nap\u00e4tie nezaru\u010duje kompatibilitu predvo\u013eby.<\/strong> Rozhodnutie z\u00e1vis\u00ed od konkr\u00e9tneho typu hotovej bat\u00e9rie, od nastavite\u013en\u00fdch parametrov sp\u00edna\u010da a od toho, \u010di je cel\u00fd syst\u00e9m schopn\u00fd nab\u00edja\u0165 sa a re\u0161tartova\u0165 bez preru\u0161enia monitorovania. Ide o \u0161pecifick\u00fa po\u017eiadavku pre dan\u00fd model.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-12v-100ah-sodium-ion-battery-main-image-001.jpg\" alt=\"\" class=\"wp-image-1180\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12 V 100 Ah sod\u00edkovo i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">\u010co vlastne znamen\u00e1 predvolen\u00e9 nastavenie LiFePO4 na sol\u00e1rnom PoE prep\u00edna\u010di?<\/h2><p class=\"wp-block-paragraph\">Linovision <strong>POE-SW804G-SOLAR<\/strong> sp\u00e1ja \u0161tvorportov\u00fd PoE prep\u00edna\u010d s sol\u00e1rnym regul\u00e1torom nab\u00edjania MPPT. Jeho <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-quick-guide\" target=\"_blank\" rel=\"noopener\">stru\u010dn\u00fd n\u00e1vod (verzia 2.1, 2. septembra 2026)<\/a> uv\u00e1dza, \u017ee ak\u00fako\u013evek in\u00fa bat\u00e9riu ako 12 V LiFePO4 je potrebn\u00e9 nakonfigurova\u0165 pomocou rozhrania RS485 a softv\u00e9ru pre PC <strong>pred pripojen\u00edm sol\u00e1rneho panelu<\/strong>. Nab\u00edjanie je obmedzen\u00e9 na <strong>10A<\/strong>. Str\u00e1nka <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-user-manual\" target=\"_blank\" rel=\"noopener\">n\u00e1vod v\u00fdrobcu<\/a> d\u00e1va nasleduj\u00face <em>Referen\u010dn\u00e9 nastavenia pre LiFePO4<\/em>, nie odpor\u00fa\u010dania t\u00fdkaj\u00face sa sod\u00edkov\u00fdch i\u00f3nov.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Nastavenie zariadenia POE-SW804G-SOLAR<\/th><th>Referen\u010dn\u00e9 \u00fadaje o LiFePO4<\/th><th>Porovnajte s konkr\u00e9tnou sod\u00edkovou bat\u00e9riou<\/th><\/tr><\/thead><tbody><tr><td>Nab\u00edjacie \/ zosil\u0148ovacie nap\u00e4tie<\/td><td><strong>14,4 V<\/strong><\/td><td>Schv\u00e1len\u00fd cie\u013eov\u00fd poplatok a regula\u010dn\u00e1 tolerancia<\/td><\/tr><tr><td>Nap\u00e4tie plav\u00e1ka<\/td><td><strong>14,2 V<\/strong><\/td><td>\u010ci je povolen\u00e9 udr\u017eiava\u0165 toto nap\u00e4tie<\/td><\/tr><tr><td>Obmedzenie nab\u00edjacieho pr\u00fadu<\/td><td><strong>10A<\/strong><\/td><td>Obmedzenie nab\u00edjacieho pr\u00fadu bat\u00e9rie v z\u00e1vislosti od teploty<\/td><\/tr><tr><td>Pr\u00fad pri ukon\u010den\u00ed nab\u00edjania<\/td><td><strong>0.5A<\/strong><\/td><td>Schv\u00e1len\u00e9 pravidlo ukon\u010denia nab\u00edjania a miesto sn\u00edmania<\/td><\/tr><tr><td>Prah prep\u00e4tia regul\u00e1tora<\/td><td><strong>15.0V<\/strong><\/td><td>Koordin\u00e1cia ochrany, nie cie\u013e v oblasti spoplat\u0148ovania<\/td><\/tr><tr><td>Ochrana proti nabitiu pri n\u00edzkych teplot\u00e1ch<\/td><td><strong>0\u00b0C<\/strong><\/td><td>Povolen\u00e1 nab\u00edjacie teplota a pr\u00fad zariadenia Pack<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Nesta\u010d\u00ed len zmeni\u0165 hodnotu boostu a ponecha\u0165 nekompatibiln\u00e9 nastavenia plav\u00e1ka, ukon\u010denia, teploty alebo ochrany.<\/p><h2 class=\"wp-block-heading\">\u010co mus\u00ed by\u0165 kompatibiln\u00e9 s hotovou 12 V sod\u00edkovo-i\u00f3novou bat\u00e9riou?<\/h2><p class=\"wp-block-paragraph\">Za\u010dnite s <strong>vybit\u00fd akumul\u00e1tor<\/strong>, nie ide o be\u017en\u00fd sod\u00edko-i\u00f3nov\u00fd \u010dl\u00e1nok ani o 12 V ozna\u010denie. Tento <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V 100Ah sod\u00edkovo i\u00f3nov\u00e1 bat\u00e9ria<\/a> technick\u00fd list poskytnut\u00fd na \u00fa\u010dely tejto recenzie<\/strong> ur\u010duje <strong>1 200 Wh menovitej energie<\/strong>, a <strong>Maxim\u00e1lne nab\u00edjacie nap\u00e4tie 15,6 V<\/strong>, a \u0161tandardn\u00fd postup s kon\u0161tantn\u00fdm pr\u00fadom\/kon\u0161tantn\u00fdm nap\u00e4t\u00edm: nab\u00edjanie pri hodnote a\u017e <strong>0,2 C (20 A)<\/strong> na <strong>15.6V<\/strong>, potom podr\u017ete <strong>15.6V<\/strong> k\u00fdm pr\u00fad neklesne na <strong>0,02 C (2 A)<\/strong>. Tento \u0161tandardn\u00fd postup je stanoven\u00fd pre <strong>0\u201345 \u00b0C<\/strong>. Neur\u010duje povolen\u00e9 spr\u00e1vanie plav\u00e1ka ani spr\u00e1vanie syst\u00e9mu BMS pri regener\u00e1cii.<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"347\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints-1024x347.png\" alt=\"\" class=\"wp-image-5309\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints-1024x347.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints-767x260.png 767w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints-300x102.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints-1536x521.png 1536w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints-18x6.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints-599x203.png 599w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-03_Published_Solar_PoE_LFP_Setpoints.png 1584w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Porovnajte skuto\u010dn\u00e9 \u010d\u00edsla:<\/p><ul class=\"wp-block-list\"><li><strong>Zv\u00fd\u0161enie nap\u00e4tia na 14,4 V v porovnan\u00ed s \u0161pecifikovanou cie\u013eovou hodnotou CC\/CV 15,6 V:<\/strong> V predvolenom nastaven\u00ed sa bat\u00e9ria m\u00f4\u017ee nabi\u0165 len \u010diasto\u010dne. To neznamen\u00e1, \u017ee je po\u0161koden\u00e1 alebo \u017ee m\u00e1 pln\u00fa kapacitu.<\/li>\n\n<li><strong>Prep\u00e4\u0165ov\u00e1 situ\u00e1cia regul\u00e1tora 15,0 V v porovnan\u00ed s cie\u013eovou hodnotou 15,6 V:<\/strong> Ak toto nastavenie ochrany zostane nezmenen\u00e9, m\u00f4\u017ee to zabr\u00e1ni\u0165 regul\u00e1toru dosiahnu\u0165 \u0161tandardn\u00e9 nab\u00edjacie nap\u00e4tie akumul\u00e1tora uveden\u00e9 v dokument\u00e1cii. Uistite sa, \u017ee je vykonan\u00e9 koordinovan\u00e9 a bezpe\u010dn\u00e9 nastavenie <em>obidve<\/em> regula\u010dn\u00e9 a ochrann\u00e9 limity, vr\u00e1tane toleranci\u00ed.<\/li>\n\n<li><strong>Z\u00e1ver 0,5 A v porovnan\u00ed s koncov\u00fdm bodom 2 A uveden\u00fdm v technickom liste:<\/strong> Ide o odli\u0161n\u00e9 pravidl\u00e1 ukon\u010denia. Vzh\u013eadom na tento rozdiel je potrebn\u00e9 schv\u00e1lenie v\u00fdrobcu a vykonanie sk\u00fa\u0161ky pr\u00fadu v vetve bat\u00e9rie.<\/li>\n\n<li><strong>Porovnanie obmedzenia regul\u00e1tora na 10 A s pr\u00edkladom \u0161tandardn\u00e9ho pr\u00fadu 20 A:<\/strong> Ni\u017e\u0161\u00ed pr\u00fad nemus\u00ed by\u0165 nutne zak\u00e1zan\u00fd. Overte si, ak\u00fd rozsah pr\u00fadu je pr\u00edpustn\u00fd a \u010di sol\u00e1rne okno st\u00e1le sp\u013a\u0148a po\u017eiadavky na energiu potrebn\u00fa na dobitie.<\/li><\/ul><p class=\"wp-block-paragraph\">V pr\u00edpade nab\u00edjania pri n\u00edzkej teplote s\u00fa v prilo\u017eenom liste k bat\u00e9rii uveden\u00e9 nasleduj\u00face \u00fadaje: <strong>10 A pri teplote od -20 do -10 \u00b0C<\/strong> a <strong>20 A pri teplote od -10 do 0 \u00b0C<\/strong>; pri teplot\u00e1ch nad 0 \u00b0C uv\u00e1dza <strong>Maxim\u00e1lny trval\u00fd nab\u00edjac\u00ed pr\u00fad 50 A<\/strong>, za predpokladu dodr\u017eania presn\u00fdch kontrol rev\u00edzie a teploty. Neobch\u00e1dzajte ochranu sp\u00edna\u010da. Overte si tie\u017e schv\u00e1len\u00e9 zn\u00ed\u017eenie v\u00fdkonu pri vysok\u00fdch teplot\u00e1ch: celkov\u00fd rozsah tepl\u00f4t nab\u00edjania uveden\u00fd v technickom liste siaha a\u017e do 70 \u00b0C, zatia\u013e \u010do \u0161tandardn\u00fd postup CC\/CV je \u0161pecifikovan\u00fd len do 45 \u00b0C.<\/p><p class=\"wp-block-paragraph\">Str\u00e1nka <a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12 V 100 Ah sod\u00edkovo i\u00f3nov\u00e1 bat\u00e9ria<\/a> pou\u017e\u00edva <strong>Ozna\u010denie modelu 12,8 V<\/strong> a odli\u0161n\u00e9 rozmery oproti \u00fadajom v dodanom technickom liste pre 12 V. Tieto \u0161pecifik\u00e1cie nekombinujte do jedn\u00e9ho schv\u00e1len\u00e9ho SKU bez potvrdenia rev\u00edzie. <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power<\/a><\/strong> s\u00fa\u010dasn\u00fd <a href=\"https:\/\/www.kmdpower.com\/sk\/news\/best-mppt-pwm-charge-controller-settings-for-12v-sodium-ion-battery\/\" target=\"_blank\" rel=\"noreferrer noopener\">N\u00e1vod na nastavenie MPPT\/PWM<\/a> poskytuje v\u0161eobecn\u00fd kontext; tento \u010dl\u00e1nok sa zaober\u00e1 ot\u00e1zkou, \u010di <strong>\u0161pecifick\u00fd PoE prep\u00edna\u010d<\/strong> m\u00f4\u017ee implementova\u0165 schv\u00e1len\u00fd profil.<\/p><h2 class=\"wp-block-heading\">Zabezpe\u010d\u00ed vlastn\u00fd profil bat\u00e9rie kompatibilitu so Switchom?<\/h2><p class=\"wp-block-paragraph\">Zabezpe\u010duje kompatibilitu <em>mo\u017en\u00e9<\/em>. Linovision obsahuje dokument\u00e1ciu k prepojeniu RS485 na USB a konfigura\u010dn\u00fd n\u00e1stroj pre PC. Ku ka\u017ed\u00e9mu pr\u00edslu\u0161n\u00e9mu po\u013eu polo\u017ete tri ot\u00e1zky: <strong>D\u00e1 sa to upravi\u0165? Umo\u017e\u0148uje aktu\u00e1lny firmv\u00e9r po\u017eadovan\u00fd rozsah? Zachov\u00e1 sa toto nastavenie aj po nabit\u00ed a re\u0161tarte a bude sa na\u010falej vykon\u00e1va\u0165?<\/strong> Vstupn\u00e9 pole nesta\u010d\u00ed na preuk\u00e1zanie dostato\u010dn\u00e9ho rozsahu.<\/p><p class=\"wp-block-paragraph\">Skontrolujte nab\u00edjacie nap\u00e4tie, spr\u00e1vanie v re\u017eime udr\u017eiavania, ukon\u010dovac\u00ed pr\u00fad, ochranu proti prep\u00e4tiu, pravidl\u00e1 pre n\u00edzke a vysok\u00e9 teploty a obmedzenie nab\u00edjacieho pr\u00fadu ako ucelen\u00fd s\u00fabor. Predov\u0161etk\u00fdm dod\u00e1van\u00e9 <strong>15.6V<\/strong> Cie\u013eov\u00e1 hodnota nab\u00edjania akumul\u00e1tora nemo\u017eno pova\u017eova\u0165 za kompatibiln\u00fa, pokia\u013e regul\u00e1tor <strong>15.0V<\/strong> Referen\u010dn\u00e9 nastavenie prep\u00e4tia zost\u00e1va v platnosti. Spr\u00e1vnu prahov\u00fa hodnotu ochrany a rezervu musia schv\u00e1li\u0165 obaja v\u00fdrobcovia; nenastavujte vy\u0161\u0161iu referen\u010dn\u00fa hodnotu.<\/p><p class=\"wp-block-paragraph\">Deaktivujte ak\u00fako\u013evek vyrovn\u00e1vaciu funkciu oloven\u00fdch bat\u00e9ri\u00ed alebo neschv\u00e1len\u00e9 nastavenia zalo\u017een\u00e9 na teplote <em>kompenz\u00e1cia nap\u00e4tia<\/em>. To sa l\u00ed\u0161i od met\u00f3dy zalo\u017eenej na teplote <em>povolenie na nab\u00edjanie alebo obmedzenia pr\u00fadu<\/em>. Syst\u00e9m BMS pou\u017e\u00edvajte na ochranu, nie ako be\u017en\u00fa met\u00f3du preru\u0161enia prebitia. Ak je povinn\u00e9 pole pevne nastaven\u00e9, nedokumentovan\u00e9 alebo mimo povolen\u00e9ho rozsahu, <strong>zamietnu\u0165 t\u00fato konfigur\u00e1ciu ovl\u00e1da\u010da<\/strong> a zv\u00e1\u017ei\u0165 pou\u017eitie samostatnej schv\u00e1lenej nab\u00edja\u010dky alebo inej architekt\u00fary nap\u00e1jania.<\/p><h2 class=\"wp-block-heading\">\u010co sa deje po\u010das kr\u00e1tkeho alebo chladn\u00e9ho obdobia na sol\u00e1rne nab\u00edjanie?<\/h2><p class=\"wp-block-paragraph\">Tento prep\u00edna\u010d nenab\u00edja izolovan\u00fa bat\u00e9riu umiestnen\u00fa na stole. Jeho sol\u00e1rny vstup m\u00f4\u017ee nap\u00e1ja\u0165 kamery, router a umo\u017e\u0148ova\u0165 nab\u00edjanie prostredn\u00edctvom spolo\u010dnej jednosmernej vetvy. V\u00fdstupn\u00fd pr\u00fad regul\u00e1tora sa automaticky <strong>\u010dist\u00fd nab\u00edjac\u00ed pr\u00fad bat\u00e9rie<\/strong>. Odde\u013ete meranie vetvy s bat\u00e9riou a pred odpo\u010d\u00edtan\u00edm hodn\u00f4t pr\u00fadu preve\u010fte za\u0165a\u017eenia na spolo\u010dn\u00fd z\u00e1klad nap\u00e4tia alebo v\u00fdkonu.<\/p><p class=\"wp-block-paragraph\">Len ako pr\u00edklad, ak <strong>10 A je pripojen\u00e9 na spolo\u010dn\u00fa zbernicu jednosmern\u00e9ho nap\u00e4tia triedy 12 V<\/strong> a jeho prev\u00e1dzkov\u00e9 za\u0165a\u017eenie <strong>3A na tej istej autobusovej zast\u00e1vke<\/strong>, pribli\u017ene <strong>7A<\/strong> m\u00f4\u017ee pr\u00fadi\u0165 do bat\u00e9rie, pri\u010dom sa nezoh\u013ead\u0148uj\u00fa straty a in\u00e9 cesty. N\u00e1vrat <strong>70 Ah \u00f7 7 A = 10 hod\u00edn<\/strong> Ide len o ide\u00e1lny v\u00fdpo\u010det pri kon\u0161tantnom pr\u00fade; kol\u00edsanie fotovoltaick\u00e9ho v\u00fdkonu, pokles nap\u00e4tia a no\u010dn\u00e1 spotreba sp\u00f4sobuj\u00fa, \u017ee skuto\u010dn\u00e9 dobitie trv\u00e1 dlh\u0161ie alebo je neist\u00e9. Nevypo\u010d\u00edtavajte v\u00fdstupn\u00fd pr\u00fad portu PoE priamo z pr\u00fadu bat\u00e9rie: nap\u00e4tia sa l\u00ed\u0161ia. Syst\u00e9m Linovision 12 V m\u00e1 tie\u017e <strong>Celkov\u00fd rozpo\u010det PoE 60 W<\/strong> a <strong>Maxim\u00e1lny v\u00fdstupn\u00fd pr\u00fad 5 A<\/strong>, preto skontrolujte maxim\u00e1lny odber kamery, infra\u010derven\u00e9ho sn\u00edma\u010da a pomocn\u00fdch zariaden\u00ed a porovnajte ich so spr\u00e1vnymi menovit\u00fdmi hodnotami.<\/p><p class=\"wp-block-paragraph\">Teplota sp\u00f4sobuje \u010fal\u0161\u00ed nes\u00falad. Referen\u010dn\u00e9 bloky LiFePO4 od spolo\u010dnosti Linovision <strong>nab\u00edjanie pri teplote ni\u017e\u0161ej ako 0 \u00b0C<\/strong> a <strong>vyb\u00edjanie pri teplote ni\u017e\u0161ej ako -20 \u00b0C<\/strong>, s <strong>Nab\u00edjanie pri 55 \u00b0C<\/strong> a <strong>Vyp\u00fa\u0161\u0165anie pri 60 \u00b0C<\/strong> teplotn\u00e9 limity. Prilo\u017een\u00fd list KMDPOWER povo\u013euje podmiene\u010dn\u00e9 nab\u00edjanie pri teplot\u00e1ch pod bodom mrazu a uv\u00e1dza rozsah vyb\u00edjania a\u017e do <strong>-40\u00b0C<\/strong>, av\u0161ak neuv\u00e1dza identick\u00fa pr\u00fadov\u00fa kapacitu pri v\u0161etk\u00fdch teplot\u00e1ch. Predvolen\u00e9 nastavenie by mohlo zabr\u00e1ni\u0165 prev\u00e1dzke bat\u00e9rie, ktor\u00fa bat\u00e9riov\u00fd modul umo\u017e\u0148uje; zmena hrani\u010dn\u00fdch hodn\u00f4t je opodstatnen\u00e1 a\u017e po tom, \u010do obaja v\u00fdrobcovia schv\u00e1lia cel\u00fd prev\u00e1dzkov\u00fd rozsah, vr\u00e1tane vlastn\u00fdch limitov regul\u00e1tora.<\/p><p class=\"wp-block-paragraph\">Chladn\u00e9 r\u00e1no m\u00f4\u017ee preto sp\u00f4sobi\u0165, \u017ee bat\u00e9ria nebude nabit\u00e1 ani po n\u00e1vrate denn\u00e9ho svetla. V polud\u0148aj\u0161\u00edch hodin\u00e1ch sa m\u00f4\u017ee prejavi\u0165 \u010fal\u0161\u00ed nedostatok nabitia. Ani jeden z t\u00fdchto probl\u00e9mov sa ned\u00e1 vyrie\u0161i\u0165 kop\u00edrovan\u00edm prednastavenia pre in\u00fd typ bat\u00e9rie.<\/p><h2 class=\"wp-block-heading\">Ako by mal v\u00fdrobca OEM overi\u0165 vyhovuj\u00face vlastnosti sol\u00e1rneho PoE prep\u00edna\u010da a sod\u00edko-i\u00f3novej bat\u00e9rie?<\/h2><p class=\"wp-block-paragraph\">Vysk\u00fa\u0161ajte <strong>nain\u0161talovan\u00fd energetick\u00fd syst\u00e9m<\/strong>: presn\u00e9 verzie bat\u00e9riov\u00e9ho modulu a syst\u00e9mu riadenia bat\u00e9ri\u00ed (BMS), firmv\u00e9r sp\u00edna\u010da, fotovoltaick\u00fd vstup, zapojenie, poistky a za\u0165a\u017eenie z akt\u00edvnych CCTV syst\u00e9mov. Testy vykon\u00e1van\u00e9 iba na regul\u00e1tore nem\u00f4\u017eu potvrdi\u0165 prev\u00e1dzku bez dozoru.<\/p><p class=\"wp-block-paragraph\"><strong>1. Zafixujte obe \u0161pecifik\u00e1cie.<\/strong> Z\u00edskajte ulo\u017een\u00fd profil regul\u00e1tora a schv\u00e1len\u00fd n\u00e1vod na nab\u00edjanie akumul\u00e1torov\u00e9ho modulu pre konkr\u00e9tnu z\u00e1sielku. Porovnajte nap\u00e4tie, tolerancie, zakon\u010denie, re\u017eim udr\u017eiavania nap\u00e4tia, limity pr\u00fadu v z\u00e1vislosti od teploty, prahov\u00e9 hodnoty n\u00edzkeho nap\u00e4tia a obnovenie syst\u00e9mu BMS. Vyrie\u0161te rozdiel v \u0161pecifik\u00e1cii medzi 12 V a 12,8 V namiesto toho, aby ste kombinovali r\u00f4zne rev\u00edzie.<\/p><p class=\"wp-block-paragraph\"><strong>2. Potvr\u010fte \u00fapravu a jej trval\u00e9 ulo\u017eenie.<\/strong> Postupujte pod\u013ea poradia pripojenia spolo\u010dnosti Linovision: <strong>nab\u00edjanie \u2192 bat\u00e9ria \u2192 sol\u00e1rny panel<\/strong>, nastavenie inej ako predvolenej bat\u00e9rie <strong>po pripojen\u00ed bat\u00e9rie a pred pripojen\u00edm fotovoltaick\u00e9ho syst\u00e9mu<\/strong>. Po povolenom vypnut\u00ed a op\u00e4tovnom zapnut\u00ed zariadenia na\u010d\u00edtajte v\u0161etky pr\u00edslu\u0161n\u00e9 nastavenia a znovu ich skontrolujte. Nevykon\u00e1vajte testy tak, \u017ee by ste \u00famyselne vyvolali vypnutie z d\u00f4vodu prep\u00e4tia.<\/p><p class=\"wp-block-paragraph\"><strong>3. Zmerajte nap\u00e4tie na svork\u00e1ch bat\u00e9rie.<\/strong> Po\u010das schv\u00e1len\u00e9ho nab\u00edjania zaznamen\u00e1vajte v\u00fdstup regul\u00e1tora, nap\u00e4tie na svork\u00e1ch bat\u00e9rie, <strong>\u010dist\u00fd pr\u00fad v vetve bat\u00e9rie<\/strong>, teplotu bat\u00e9rie a povolenie nab\u00edjania zo syst\u00e9mu BMS. Zaznamenajte regul\u00e1ciu nap\u00e4tia, pokles pr\u00fadu a ukon\u010denie nab\u00edjania s nepretr\u017eit\u00fdm za\u0165a\u017een\u00edm z kamerov\u00e9ho syst\u00e9mu aj bez neho. Indik\u00e1tor \u201enab\u00edjania\u201c neznamen\u00e1, \u017ee bat\u00e9ria je skuto\u010dne nab\u00edjan\u00e1.<\/p><p class=\"wp-block-paragraph\"><strong>4. Pridajte skuto\u010dn\u00e9 za\u0165a\u017eenie kamery.<\/strong> Zahr\u0148te kamery, infra\u010derven\u00e9 osvetlenie, komunika\u010dn\u00e9 zariadenia a pr\u00edslu\u0161n\u00e9 pomocn\u00e9 za\u0165a\u017eenia. Overte, \u010di <strong>Celkov\u00fd rozpo\u010det PoE 60 W pri 12 V<\/strong>, limit za\u0165a\u017eenia v\u00fdstupu 5 A a ak\u00e9ko\u013evek obmedzenia jednotliv\u00fdch konektorov. Overte prev\u00e1dzkov\u00fa dostupnos\u0165 kamery po\u010das zmien stavov nab\u00edjania v riadiacej jednotke, vr\u00e1tane preru\u0161en\u00ed pripojenia k cloudu a obnovenia prev\u00e1dzky.<\/p><p class=\"wp-block-paragraph\"><strong>5. Otestujte povolen\u00e9 teplotn\u00e9 medze.<\/strong> Porovnajte predvolen\u00e9 ochrann\u00e9 nastavenia regul\u00e1tora pre teploty 0 \u00b0C a \u201320 \u00b0C so schv\u00e1len\u00fdmi rozsahmi podmienen\u00e9ho nab\u00edjania a vyb\u00edjania, ktor\u00e9 uv\u00e1dza v\u00fdrobca bat\u00e9rie. Pou\u017e\u00edvajte regulovan\u00e9 teploty a skontrolujte umiestnenie sn\u00edma\u010dov. Nikdy nevnucujte bat\u00e9rii pr\u00fad mimo schv\u00e1len\u00fdch limitov.<\/p><p class=\"wp-block-paragraph\"><strong>6. Zhodno\u0165te de\u0148 na zotavenie.<\/strong> Str\u00e1nka <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-user-manual\" target=\"_blank\" rel=\"noreferrer noopener\">N\u00e1vod na in\u0161tal\u00e1ciu Linovision<\/a> hovor\u00ed a <strong>Nap\u00e4tie 12 V bat\u00e9rie mus\u00ed by\u0165 vy\u0161\u0161ie ako 9 V, aby sa spustila prev\u00e1dzka regul\u00e1tora<\/strong>. V tabu\u013eke KMDPOWER je uveden\u00fd <strong>Vypnutie pri vyb\u00edjan\u00ed na 8 V<\/strong>\u2014nejde o zaru\u010den\u00fd v\u00fdstupn\u00fd nap\u00e4tie syst\u00e9mu BMS ani nap\u00e4tie pri obnoven\u00ed. Po hlbokom vybit\u00ed alebo odpojen\u00ed syst\u00e9mu BMS skontrolujte, \u010di sa regul\u00e1tor skuto\u010dne dok\u00e1\u017ee re\u0161tartova\u0165 a obnovi\u0165 nap\u00e1janie kamery; to, \u017ee sa pri v\u00fdchode slnka objav\u00ed fotovoltaick\u00fd panel, nie je d\u00f4kazom auton\u00f3mneho obnovenia. Overte tie\u017e, \u010di nastavenia odpojenia a op\u00e4tovn\u00e9ho pripojenia zariaden\u00ed pri n\u00edzkom nap\u00e4t\u00ed zachov\u00e1vaj\u00fa dostato\u010dn\u00fa rezervu na to, aby kamery zostali v prev\u00e1dzke.<\/p><p class=\"wp-block-paragraph\">Miera <strong>energia nabitia bat\u00e9rie (Wh) = \u222b nap\u00e4tie na svork\u00e1ch bat\u00e9rie \u00d7 nameran\u00fd \u010dist\u00fd nab\u00edjac\u00ed pr\u00fad bat\u00e9rie dt<\/strong> po\u010das schv\u00e1len\u00e9ho intervalu nab\u00edjania a samostatne sledova\u0165 spotrebu energie a v\u00fdrobu energie z fotovoltaick\u00fdch syst\u00e9mov. Zaznamen\u00e1va\u0165 pr\u00ed\u010diny por\u00fach a ich odstr\u00e1nenie, nielen \u00faspe\u0161n\u00e9 polud\u0148aj\u0161ie nab\u00edjanie.<\/p><h2 class=\"wp-block-heading\">Kedy by mal v\u00fdrobca OEM ponecha\u0165 prep\u00edna\u010d, vymeni\u0165 ho alebo odmietnu\u0165 sp\u00e1rovanie bat\u00e9rie?<\/h2><p class=\"wp-block-paragraph\">V\u00fdsledok mus\u00ed sl\u00fa\u017ei\u0165 ako podklad pre rozhodnutie o obstar\u00e1van\u00ed, nie len ako zoznam nastaven\u00ed.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Overen\u00fd zisten\u00fd fakt<\/th><th>Rozhodnutie o obstar\u00e1van\u00ed alebo o n\u00e1vrhu<\/th><\/tr><\/thead><tbody><tr><td>V\u0161etky nastavenia nap\u00e4tia, zakon\u010denia, teploty a ochrany sp\u013a\u0148aj\u00fa schv\u00e1len\u00e9 po\u017eiadavky na bat\u00e9riov\u00fd modul; syst\u00e9mov\u00e9 testy prebehli \u00faspe\u0161ne<\/td><td><strong>Overte tento nakonfigurovan\u00fd prep\u00edna\u010d a presn\u00fa verziu bat\u00e9rie<\/strong><\/td><\/tr><tr><td>Po\u017eiadavku na nab\u00edjanie akumul\u00e1tora s nap\u00e4t\u00edm 15,6 V nie je mo\u017en\u00e9 zos\u00faladi\u0165 s nastavite\u013en\u00fdmi limitmi nab\u00edjania a prep\u00e4tia regul\u00e1tora<\/td><td><strong>Zme\u0148te architekt\u00faru nab\u00edjania alebo prepnite<\/strong>; nespoliehajte sa na vypnutia syst\u00e9mu BMS<\/td><\/tr><tr><td>Spr\u00e1vanie v re\u017eime pln\u00e9ho nabitia alebo pri n\u00edzkych teplot\u00e1ch nezodpoved\u00e1 schv\u00e1len\u00e9mu profilu bat\u00e9rie<\/td><td><strong>Zru\u0161i\u0165 predvolen\u00fd profil<\/strong> a pou\u017ei\u0165 schv\u00e1len\u00fa alternat\u00edvu<\/td><\/tr><tr><td>Nab\u00edjanie je bezpe\u010dn\u00e9, av\u0161ak maxim\u00e1lny pr\u00fad 10 A a po\u010det hod\u00edn slne\u010dn\u00e9ho svitu nesta\u010dia na pokrytie dennej spotreby<\/td><td><strong>Prehodnoti\u0165 v\u00fdkon fotovoltaick\u00e9ho syst\u00e9mu, nab\u00edjac\u00ed v\u00fdkon a denn\u00fa energetick\u00fa bilanciu<\/strong><\/td><\/tr><tr><td>Za\u0165a\u017eenie PoE presahuje menovit\u00fa hodnotu alebo doch\u00e1dza k preru\u0161eniu prev\u00e1dzky kamery po\u010das prechodov medzi f\u00e1zami nab\u00edjania<\/td><td><strong>Opravte trasu za\u0165a\u017eenia\/nap\u00e1jania<\/strong> predt\u00fdm, ako si k\u00fapite bat\u00e9riu s v\u00e4\u010d\u0161ou kapacitou<\/td><\/tr><tr><td>Vypnutie syst\u00e9mu BMS zabra\u0148uje tomu, aby regul\u00e1tor dosiahol \u0161tartovacie podmienky &gt;9 V<\/td><td><strong>Schv\u00e1lenie pozastavi\u0165, k\u00fdm sa neover\u00ed postup automatick\u00e9ho obnovenia<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Paraleln\u00e9 bat\u00e9rie schv\u00e1len\u00e9 v\u00fdrobcom poskytuj\u00fa rezervu, <strong>nie vy\u0161\u0161ie menovit\u00e9 nap\u00e4tie ani viac, ako je nab\u00edjac\u00ed pr\u00fad sp\u00edna\u010da 10 A<\/strong>. V\u00e4\u010d\u0161ia bat\u00e9ria m\u00f4\u017ee pred\u013a\u017ei\u0165 dobu z\u00e1lohovania, pri\u010dom sa v\u0161ak zv\u00fd\u0161i \u010das potrebn\u00fd na jej dobitie. Zaznamenajte si inform\u00e1cie o firmv\u00e9ri, obmedzeniach, pr\u00fadoch v vetv\u00e1ch, obnoven\u00ed, teplotnom spr\u00e1van\u00ed a funk\u010dnosti kamery.<\/p><h2 class=\"wp-block-heading\">\u010casto kladen\u00e9 ot\u00e1zky<\/h2><h3 class=\"wp-block-heading\">M\u00f4\u017ee nab\u00edja\u010dka nastaven\u00e1 na 14,4 V automaticky nab\u00edja\u0165 sod\u00edko-i\u00f3nov\u00fa bat\u00e9riu triedy 12 V?<\/h3><p class=\"wp-block-paragraph\">Nie. Schv\u00e1len\u00fd profil z\u00e1vis\u00ed od konkr\u00e9tneho hotov\u00e9ho balenia. V tomto dodanom technickom liste KMDPOWER je \u0161pecifikovan\u00e9 <strong>\u0160tandardn\u00e1 cie\u013eov\u00e1 hodnota CC\/CV 15,6 V<\/strong>; bat\u00e9ria s predvolen\u00fdm nap\u00e4t\u00edm 14,4 V sa s\u00edce m\u00f4\u017ee \u010diasto\u010dne nabi\u0165, nemo\u017eno v\u0161ak predpoklada\u0165, \u017ee dosiahne \u0161pecifikovan\u00fd koniec nab\u00edjania alebo pou\u017eite\u013en\u00fa kapacitu.<\/p><h3 class=\"wp-block-heading\">Ak prep\u00edna\u010d pon\u00faka nastavenie pre l\u00edtiov\u00e9 bat\u00e9rie, sta\u010d\u00ed to?<\/h3><p class=\"wp-block-paragraph\">Nie. \u0160t\u00edtok s ozna\u010den\u00edm \u201el\u00edtio\u201c neuv\u00e1dza limity nap\u00e4tia akumul\u00e1tora ani spr\u00e1vanie syst\u00e9mu BMS. Porovnajte upravite\u013en\u00e9 nastavenia nab\u00edjania, ukon\u010denia nab\u00edjania, ochrany a teploty na prep\u00edna\u010di s presnou verziou akumul\u00e1tora a potom syst\u00e9m otestujte.<\/p><h3 class=\"wp-block-heading\">Dok\u00e1\u017ee syst\u00e9m BMS chr\u00e1ni\u0165 akumul\u00e1tor pred nespr\u00e1vnym profilom nab\u00edjania?<\/h3><p class=\"wp-block-paragraph\">Syst\u00e9m BMS sl\u00fa\u017ei ako ochrann\u00e1 z\u00e1loha, nie ako be\u017en\u00e1 regul\u00e1cia nab\u00edjania. Opakovan\u00e9 aktiv\u00e1cie ochrany m\u00f4\u017eu naru\u0161i\u0165 nab\u00edjanie a prev\u00e1dzku kamerov\u00e9ho syst\u00e9mu. Pou\u017eite schv\u00e1len\u00fd profil regul\u00e1tora a samostatne overte obnovenie funk\u010dnosti syst\u00e9mu BMS.<\/p><h3 class=\"wp-block-heading\">Mal by sol\u00e1rny PoE regul\u00e1tor pokra\u010dova\u0165 v udr\u017eiavacom nab\u00edjan\u00ed sod\u00edko-i\u00f3novej bat\u00e9rie?<\/h3><p class=\"wp-block-paragraph\">Iba v pr\u00edpade, ak v\u00fdrobca bat\u00e9ri\u00ed schv\u00e1li nap\u00e4tie a spr\u00e1vanie pri udr\u017ean\u00ed nap\u00e4tia pre dan\u00fd akumul\u00e1torov\u00fd blok. Sp\u00edna\u010d <strong>14,2 V LiFePO4 \u2013 udr\u017eiavacie nap\u00e4tie<\/strong> nie je pre konfigur\u00e1ciu s i\u00f3nmi sod\u00edka ani automaticky bezpe\u010dn\u00e1, ani nevyhnutn\u00e1.<\/p><h3 class=\"wp-block-heading\">Dok\u00e1\u017ee sol\u00e1rna nab\u00edja\u010dka s v\u00fdkonom 10 A \u00faplne nabi\u0165 bat\u00e9riu s kapacitou 100 Ah za desa\u0165 hod\u00edn?<\/h3><p class=\"wp-block-paragraph\">Nie nevyhnutne. <strong>100 Ah \u00f7 10 A = 10 hod\u00edn<\/strong> Ide o idealizovan\u00fd v\u00fdpo\u010det pr\u00fadu, nie o predpove\u010f pre konkr\u00e9tnu sol\u00e1rnu lokalitu. Za\u0165a\u017eenie \u017eiv\u00fdch kamier, kol\u00edsanie v\u00fdkonu fotovoltaick\u00fdch panelov, pokles pr\u00fadu, teplotn\u00e9 obmedzenia a straty pri nab\u00edjan\u00ed m\u00f4\u017eu dobu zotavenia podstatne pred\u013a\u017ei\u0165.<\/p><h2 class=\"wp-block-heading\">Z\u00e1ver<\/h2><p class=\"wp-block-paragraph\">Univerz\u00e1lny sol\u00e1rny PoE prep\u00edna\u010d zalo\u017een\u00fd na technol\u00f3gii LiFePO4 <strong>m\u00f4\u017ee by\u0165 konfigurovate\u013en\u00fd<\/strong> pre <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">12 V sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong> bal\u00edk, ale jeho predvolen\u00e9 nastavenia nie s\u00fa spr\u00e1vne len preto, \u017ee oba syst\u00e9my uv\u00e1dzaj\u00fa hodnotu 12 V. Pre dod\u00e1van\u00fd <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V 100Ah sod\u00edkovo i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong> \u0161pecifik\u00e1cia, t\u00e1 <strong>Cie\u013eov\u00e1 hodnota nab\u00edjania 15,6 V<\/strong>, <strong>2A \u0161tandardn\u00fd koncov\u00fd bod<\/strong>, podmienen\u00e9 nab\u00edjanie za studena a <strong>Vypnutie pri vyb\u00edjan\u00ed na 8 V<\/strong> uvies\u0165 konkr\u00e9tne kontroly v porovnan\u00ed s referen\u010dn\u00fdmi nastaveniami tohto prep\u00edna\u010da Linovision \u2013 a jeho <strong>&gt;Po\u017eiadavka na spustenie s nap\u00e4t\u00edm 9 V<\/strong>. Pred schv\u00e1len\u00edm sp\u00e1rovania overte skuto\u010dn\u00fd rozsah nastavenia firmv\u00e9ru, nab\u00edjanie cez bat\u00e9riov\u00fa vetvu, \u0161pi\u010dkov\u00e9 za\u0165a\u017eenie PoE a automatick\u00fd re\u0161tart. Podrobnej\u0161ie pokyny n\u00e1jdete v <a href=\"https:\/\/www.kmdpower.com\/sk\/news\/best-mppt-pwm-charge-controller-settings-for-12v-sodium-ion-battery\/\">\u010cl\u00e1nok o nastaveniach MPPT\/PWM zariadenia Kamada Power<\/a>. <a href=\"https:\/\/www.kmdpower.com\/sk\/contact-us\/\">Kontaktujte spolo\u010dnos\u0165 Kamada Power<\/a> spolu s firmv\u00e9rom sp\u00edna\u010da, exportom nastaven\u00ed, rev\u00edziou bat\u00e9rie, teplotami v prev\u00e1dzke a predpokladan\u00fdm objemom, aby ste mohli po\u017eiada\u0165 o pos\u00fadenie kompatibility konkr\u00e9tneho modelu.<\/p><p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>V\u00fdrobca OEM vyr\u00e1ba sol\u00e1rnu CCTV skri\u0148u na b\u00e1ze all-in-one PoE prep\u00edna\u010da, ktor\u00fd nab\u00edja bat\u00e9riu a nap\u00e1ja kamery. Prep\u00edna\u010d sa dod\u00e1va s prednastaven\u00edm pre LiFePO4; v\u00fdrobca OEM chce nain\u0161talova\u0165 sod\u00edko-i\u00f3nov\u00fa bat\u00e9riov\u00fa sadu triedy 12 V. Nomin\u00e1lne nap\u00e4tie nezaru\u010duje kompatibilitu s prednastaven\u00edm. Rozhodnutie z\u00e1vis\u00ed od konkr\u00e9tneho typu hotovej bat\u00e9rie, upravite\u013en\u00fdch nastaven\u00ed prep\u00edna\u010da,\u2026<\/p>","protected":false},"author":1,"featured_media":1181,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5308","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/comments?post=5308"}],"version-history":[{"count":2,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5308\/revisions"}],"predecessor-version":[{"id":5311,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5308\/revisions\/5311"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media?parent=5308"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/categories?post=5308"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/tags?post=5308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}