{"id":5305,"date":"2026-11-18T06:59:21","date_gmt":"2026-11-18T06:59:21","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5305"},"modified":"2026-11-18T06:59:24","modified_gmt":"2026-11-18T06:59:24","slug":"will-a-solar-poe-switch-disconnect-a-12v-sodium-ion-battery-before-its-usable-energy-is-exhausted","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sk\/news\/will-a-solar-poe-switch-disconnect-a-12v-sodium-ion-battery-before-its-usable-energy-is-exhausted\/","title":{"rendered":"Odpoj\u00ed sol\u00e1rny PoE prep\u00edna\u010d 12 V sod\u00edkovo-i\u00f3nov\u00fa bat\u00e9riu sk\u00f4r, ako sa vy\u010derp\u00e1 jej vyu\u017eite\u013en\u00e1 energia?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Vzdialen\u00e9 miesto s kamerov\u00fdm syst\u00e9mom prestane nahr\u00e1va\u0165 e\u0161te pred \u00fasvitom. Sol\u00e1rny PoE prep\u00edna\u010d hl\u00e1si vypnutie kv\u00f4li n\u00edzkej \u00farovni nabitia bat\u00e9rie, ale <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong> Bat\u00e9ria sa nedostala do stavu ochrany proti podp\u00e4t\u00ed v syst\u00e9me BMS. Je bat\u00e9ria nedostato\u010dnej kapacity, alebo sp\u00edna\u010d pred\u010dasne odpojil z\u00e1\u0165a\u017e? <strong>Sol\u00e1rny PoE prep\u00edna\u010d m\u00f4\u017ee odpoji\u0165 kamery e\u0161te predt\u00fdm, ako bat\u00e9ria dosiahne limit vybitia, av\u0161ak nameran\u00e1 hodnota nap\u00e4tia nedok\u00e1\u017ee kvantifikova\u0165 zost\u00e1vaj\u00facu vyu\u017eite\u013en\u00fa energiu.<\/strong> Porovnajte LVD, nap\u00e4tie pri op\u00e4tovnom pripojen\u00ed za\u0165a\u017eenia (LVR), schv\u00e1len\u00e9 limity bat\u00e9rie a nap\u00e4tie pri skuto\u010dnom za\u0165a\u017een\u00ed kamery.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-12v-100ah-sodium-ion-battery-main-image-002.jpg\" alt=\"\" class=\"wp-image-1181\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V 100Ah sod\u00edkovo i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">M\u00f4\u017ee sa sol\u00e1rny PoE prep\u00edna\u010d vypn\u00fa\u0165 sk\u00f4r, ako to urob\u00ed syst\u00e9m BMS bat\u00e9rie?<\/h2><p class=\"wp-block-paragraph\">\u00c1no. Mnoh\u00e9 sol\u00e1rne PoE regul\u00e1tory riadia za\u0165a\u017eenie kamery oddelene od vn\u00fatornej ochrany bat\u00e9rie. Regul\u00e1tor m\u00f4\u017ee vypn\u00fa\u0165 v\u00fdstup PoE alebo DC, ke\u010f nameran\u00e9 vstupn\u00e9 nap\u00e4tie bat\u00e9rie dosiahne naprogramovan\u00fa prahov\u00fa hodnotu. Syst\u00e9m BMS m\u00f4\u017ee v tom momente st\u00e1le povo\u013eova\u0165 vyb\u00edjanie. Nie je to nutne porucha regul\u00e1tora: funkcia LVD je navrhnut\u00e1 tak, aby zachovala rezervu bat\u00e9rie, zabr\u00e1nila \u0161kodliv\u00e9mu vyb\u00edjaniu a poskytla syst\u00e9mu definovan\u00fd bod obnovenia.<\/p><p class=\"wp-block-paragraph\">Na architekt\u00fare z\u00e1le\u017e\u00ed. Integrovan\u00e1 sol\u00e1rna jednotka PoE m\u00f4\u017ee vypn\u00fa\u0165 svoj v\u00fdstup PoE. Samostatn\u00fd MPPT m\u00f4\u017ee namiesto toho ovl\u00e1da\u0165 extern\u00e9 rel\u00e9, zatia\u013e \u010do injektor pripojen\u00fd k bat\u00e9rii m\u00f4\u017ee ignorova\u0165 sign\u00e1l na regul\u00e1ciu za\u0165a\u017eenia. Skontrolujte tie\u017e \u010dasovan\u00e9 a denn\u00e9 prev\u00e1dzkov\u00e9 re\u017eimy. <strong>Sk\u00f4r ne\u017e budete obvi\u0148ova\u0165 bat\u00e9riu, zistite, \u010do vlastne sp\u00f4sobuje v\u00fdpadok nap\u00e1jania fotoapar\u00e1tu.<\/strong><\/p><p class=\"wp-block-paragraph\">Str\u00e1nka <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-user-manual\" target=\"_blank\" rel=\"noreferrer noopener\">N\u00e1vod k obsluhe Linovision POE-SW804G-SOLAR<\/a> uv\u00e1dza funkciu ochrany proti nadmern\u00e9mu vybit\u00ed, ktor\u00e1 vypne v\u00fdstupn\u00e9 nap\u00e4tie. V referen\u010dnom profile 12 V LiFePO4 je ako hodnota pre nadmern\u00e9 vybitie uveden\u00e1 hodnota 11,2 V a pre obnovenie 12,3 V. Ide o <strong>referen\u010dn\u00e9 nastavenia \u0161pecifick\u00e9 pre dan\u00e9 zariadenie v r\u00e1mci tohto profilu bat\u00e9rie, nie odpor\u00fa\u010dania pre sod\u00edkovo-i\u00f3nov\u00e9 bat\u00e9rie<\/strong>. Presn\u00fa konfigur\u00e1ciu firmv\u00e9ru a spr\u00e1vanie zariadenia je potrebn\u00e9 overi\u0165 v konkr\u00e9tnom projekte.<\/p><h2 class=\"wp-block-heading\">\u010co n\u00e1m prezr\u00e1dzaj\u00fa zverejnen\u00e9 nastavenia LVD a op\u00e4tovn\u00e9ho pripojenia?<\/h2><p class=\"wp-block-paragraph\">R\u00f4zne regul\u00e1tory \u2013 a r\u00f4zne re\u017eimy v r\u00e1mci jedn\u00e9ho regul\u00e1tora \u2013 pou\u017e\u00edvaj\u00fa podstatne odli\u0161n\u00e9 prahov\u00e9 hodnoty. Ni\u017e\u0161ie s\u00fa uveden\u00e9 overite\u013en\u00e9 pr\u00edklady <strong>zverejnen\u00e9 nastavenia zariadenia<\/strong>, nie ide o odpor\u00fa\u010dan\u00e9 nastavenia pre sod\u00edko-i\u00f3nov\u00fa bat\u00e9riu.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>V\u00fdrobca a zdokumentovan\u00fd re\u017eim<\/th><th>Odpojenie 12 V z\u00e1\u0165a\u017ee<\/th><th>Op\u00e4tovn\u00e9 pripojenie 12 V spotrebi\u010da<\/th><th>D\u00f4le\u017eit\u00e9 obmedzenie<\/th><\/tr><\/thead><tbody><tr><td>Linovision POE-SW804G-SOLAR, profil referen\u010dn\u00e9ho 4S LiFePO4<\/td><td>11,2 V<\/td><td>12.3V<\/td><td>Overte skuto\u010dn\u00fa konfigur\u00e1ciu a implement\u00e1ciu riadenia za\u0165a\u017eenia<\/td><\/tr><tr><td>Victron SmartSolar, algoritmus pre be\u017en\u00e9 za\u0165a\u017eenie 2<\/td><td>11.8V<\/td><td>14,0 V<\/td><td>Ovl\u00e1da funkciu za\u0165a\u017eenia a v\u00fdstupu alebo extern\u00e9 odpojovacie zariadenie, v z\u00e1vislosti od modelu<\/td><\/tr><tr><td>Morningstar GenStar MPPT, LiFePO4 \u2013 prednastavenie 5<\/td><td>12.5V<\/td><td>13,15 V<\/td><td>Jednomin\u00fatov\u00e9 varovanie pred n\u00edzkym tlakom v krvi; <strong>0 mV\/A<\/strong> aktu\u00e1lna kompenz\u00e1cia; nejde o prednastavenie sod\u00edkov\u00fdch i\u00f3nov<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Zdroje: <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-user-manual\" target=\"_blank\" rel=\"noreferrer noopener\">N\u00e1vod na obsluhu ovl\u00e1da\u010da Linovision<\/a>, <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/Manual_SmartSolar_MPPT_150-60_up_to_250-70\/en\/configuration-and-settings.html\" target=\"_blank\" rel=\"noreferrer noopener\">Nastavenia za\u0165a\u017eenia a v\u00fdstupu zariadenia Victron SmartSolar<\/a>a <a href=\"https:\/\/knowledgebase.morningstarcorp.com\/docs\/53-load-control-information\" target=\"_blank\" rel=\"noreferrer noopener\">Dokument\u00e1cia k syst\u00e9mu riadenia za\u0165a\u017eenia Morningstar GenStar<\/a>. Porovn\u00e1vajte iba uveden\u00e9 modely a re\u017eimy; tieto \u010d\u00edsla nie s\u00fa vz\u00e1jomne zamenite\u013en\u00e9.<\/p><p class=\"wp-block-paragraph\"><strong>Obr\u00e1zok 1 \u2014 Uverejnen\u00e9 prahov\u00e9 hodnoty LVD a LVR pre 12 V regul\u00e1tor<\/strong><\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"468\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-1024x468.png\" alt=\"\" class=\"wp-image-5306\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-1024x468.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-300x137.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-18x8.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-767x351.png 767w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-599x274.png 599w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart.png 1504w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Zverejnen\u00e9 nastavenia odpojenia a op\u00e4tovn\u00e9ho pripojenia pri n\u00edzkom nap\u00e4t\u00ed pre vybran\u00e9 re\u017eimy regul\u00e1torov Linovision, Victron a Morningstar. Ide o referen\u010dn\u00e9 nastavenia v\u00fdrobcu, nie o odpor\u00fa\u010dan\u00e9 hodnoty LVD\/LVR pre <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sod\u00edkov\u00e1 bat\u00e9ria Kamada Power<\/a><\/strong>.<\/p><p class=\"wp-block-paragraph\">Nap\u00e4tie pri op\u00e4tovnom zapnut\u00ed m\u00f4\u017ee by\u0165 v\u00fdrazne vy\u0161\u0161ie ako nap\u00e4tie pri vypnut\u00ed. T\u00e1to hyster\u00e9za obmedzuje po\u010det cyklov, m\u00f4\u017ee v\u0161ak sp\u00f4sobi\u0165, \u017ee zariadenie zostane po v\u00fdchode slnka mimo prev\u00e1dzky. N\u00e1rast nap\u00e4tia v nezat\u00ed\u017eenej bat\u00e9rii neposkytuje dostato\u010dn\u00e9 mno\u017estvo energie na trval\u00e9 op\u00e4tovn\u00e9 spustenie.<\/p><h2 class=\"wp-block-heading\">M\u00e1 12 V sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria pri LVD e\u0161te vyu\u017eite\u013en\u00fa energiu?<\/h2><p class=\"wp-block-paragraph\">Mo\u017eno, ale <strong>nie len preto, \u017ee syst\u00e9m BMS sa nespustil<\/strong>. V dodanom technickom liste KMDPOWER 12 V 100 Ah sa uv\u00e1dza <strong>Menovit\u00e9 nap\u00e4tie 12 V, kapacita 100 Ah, menovit\u00e1 energia 1 200 Wh, maxim\u00e1lne nab\u00edjacie nap\u00e4tie 15,6 V a vyp\u00ednacie nap\u00e4tie pri vyb\u00edjan\u00ed 8 V<\/strong>. Hodnota 8 V je ochrann\u00fd koncov\u00fd bod, <strong>nie je odpor\u00fa\u010dan\u00fd sol\u00e1rny PoE LVD<\/strong> alebo d\u00f4kaz o pou\u017eite\u013enej hodnote Wh pod prahovou hodnotou regul\u00e1tora. T\u00e1to <a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12 V 100 Ah sod\u00edkovo i\u00f3nov\u00e1 bat\u00e9ria<\/a> pou\u017e\u00edva ozna\u010denie modelu 12,8 V; rev\u00edzie nezlu\u010dujte bez potvrdenia. Z\u00edskajte \u00fadaje o nabit\u00ed a vybit\u00ed, nastavenia BMS a teplotn\u00e9 limity. <strong>Samotn\u00e9 nap\u00e4tie nedok\u00e1\u017ee vyjadri\u0165 mno\u017estvo zost\u00e1vaj\u00facej energie.<\/strong><\/p><p class=\"wp-block-paragraph\">Nap\u00e4tie na svork\u00e1ch bat\u00e9rie ovplyv\u0148uje stav nabitia, za\u0165a\u017eovac\u00ed pr\u00fad, teplota a vn\u00fatorn\u00fd odpor. Regul\u00e1tor PoE zoh\u013ead\u0148uje aj straty v kabel\u00e1\u017ei a konektoroch. Pri vysokom za\u0165a\u017een\u00ed m\u00f4\u017ee nameran\u00e9 nap\u00e4tie regul\u00e1tora prekro\u010di\u0165 hodnotu LVD, zatia\u013e \u010do nap\u00e4tie na svork\u00e1ch bat\u00e9rie zost\u00e1va vy\u0161\u0161ie.<\/p><p class=\"wp-block-paragraph\">Napr\u00edklad, <strong>5 A \u00d7 0,04 \u03a9 = 0,20 V<\/strong> pokles. Ovl\u00e1da\u010d by mohol namera\u0165 11,2 V, zatia\u013e \u010do bat\u00e9ria by ukazovala 11,4 V. Ide o hypotetick\u00fd pr\u00edpad, nie o test spolo\u010dnosti KMDPOWER. Jednotka Linovision 12 V uv\u00e1dza <strong>60 W PoE kapacita a maxim\u00e1lny v\u00fdstupn\u00fd pr\u00fad 5 A<\/strong>; skontrolujte obe hrani\u010dn\u00e9 hodnoty aj \u0161pi\u010dkov\u00fd v\u00fdkon kamier, nielen priemern\u00fd pr\u00edkon v wattoch. Skuto\u010dn\u00fd odber 5 A mus\u00ed tie\u017e sp\u013a\u0148a\u0165 v\u0161etky menovit\u00e9 hodnoty zariaden\u00ed a v\u00fdstupov. <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-4-ports-mppt-solar-poe-switch\" target=\"_blank\" rel=\"noreferrer noopener\">Technick\u00e9 \u00fadaje Linovision<\/a>.<\/p><p class=\"wp-block-paragraph\">Na kvantifik\u00e1ciu energie zadr\u017eanej syst\u00e9mom LVD porovnajte schv\u00e1len\u00e9 testy vyb\u00edjania pri rovnakom po\u010diato\u010dnom stave bat\u00e9rie, pri zhodnom za\u0165a\u017een\u00ed a teplote, s vypnut\u00fdm sol\u00e1rnym nab\u00edjan\u00edm alebo s jeho samostatn\u00fdm meran\u00edm:<\/p><p class=\"wp-block-paragraph\"><strong>Energia dodan\u00e1 zo strany bat\u00e9rie pred aktiv\u00e1ciou LVD (Wh) = \u222b nap\u00e4tie na svork\u00e1ch bat\u00e9rie \u00d7 \u010dist\u00fd vyb\u00edjac\u00ed pr\u00fad bat\u00e9rie dt, a\u017e do prvej aktiv\u00e1cie LVD.<\/strong><\/p><p class=\"wp-block-paragraph\">Samostatn\u00e1 schv\u00e1len\u00e1 sk\u00fa\u0161ka vyb\u00edjania m\u00f4\u017ee ur\u010di\u0165 dodato\u010dn\u00fa energiu v r\u00e1mci povolen\u00fdch limitov bat\u00e9rie. Porovnajte hodnotu Wh na strane bat\u00e9rie na rovnakom z\u00e1klade a hodnotu Wh na strane za\u0165a\u017eenia meran\u00fa pomocou meradla PoE zmerajte samostatne, aby ste zachytili straty pri konverzii a v rozvode. Rozdiel je <em>energia, ktor\u00e1 nie je k dispoz\u00edcii v r\u00e1mci tejto testovanej konfigur\u00e1cie regul\u00e1tora<\/em>, nie pevn\u00e9 percento z 1 200 Wh. Nikdy neobch\u00e1dzajte syst\u00e9m BMS.<\/p><h3 class=\"wp-block-heading\">Pre\u010do je hrani\u010dn\u00e1 hodnota BMS ako cie\u013eov\u00e1 hodnota pre LVD v be\u017enej praxi nepou\u017eite\u013en\u00e1<\/h3><p class=\"wp-block-paragraph\">Vypnutie syst\u00e9mu BMS v d\u00f4sledku podp\u00e4tia predstavuje ochrann\u00fd mechanizmus poslednej in\u0161tancie, nie be\u017en\u00fd cie\u013e vypnutia v r\u00e1mci monitorovania. Nap\u00e1jan\u00fd modul <strong>Vypnutie pri vyb\u00edjan\u00ed na 8 V<\/strong> nie je pokynom na zn\u00ed\u017eenie nap\u00e4tia LVD regul\u00e1tora na 8 V. Je potrebn\u00e9 zoh\u013eadni\u0165 overen\u00e9 rezervy pre pokles nap\u00e4tia, minim\u00e1lny vstupn\u00fd nap\u00e4tie meni\u010da, teplotu a rezervu; v opa\u010dnom pr\u00edpade m\u00f4\u017ee d\u00f4js\u0165 k n\u00e1hlym v\u00fdpadkom a opakovan\u00fdm resetom. Existuje <strong>neexistuje univerz\u00e1lna hodnota LVD pre 12 V sod\u00edko-i\u00f3nov\u00e9 bat\u00e9rie<\/strong>.<\/p><h2 class=\"wp-block-heading\">Pre\u010do by kamery mohli zosta\u0165 offline aj po obnoven\u00ed sol\u00e1rneho nab\u00edjania?<\/h2><p class=\"wp-block-paragraph\">Ovl\u00e1da\u010d sa pri dosiahnut\u00ed \u00farovne LVD odpoj\u00ed a pred op\u00e4tovn\u00fdm pripojen\u00edm m\u00f4\u017ee \u010daka\u0165 na dosiahnutie \u00farovne LVR, uplynutie \u010dasov\u00e9ho oneskorenia alebo splnenie inej podmienky. <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/Manual_SmartSolar_MPPT_150-60_up_to_250-70\/en\/configuration-and-settings.html\" target=\"_blank\" rel=\"noreferrer noopener\">N\u00e1vod na pou\u017eitie zariadenia Victron SmartSolar<\/a> ur\u010duje dvojmin\u00fatov\u00e9 oneskorenie reakcie pre ur\u010dit\u00e9 algoritmy za\u0165a\u017eenia. <a href=\"https:\/\/knowledgebase.morningstarcorp.com\/docs\/53-load-control-information\" target=\"_blank\" rel=\"noreferrer noopener\">Morningstar<\/a> zaznamen\u00e1va upozornenia a aktu\u00e1lne od\u0161kodnenie, ale jeho <strong>Prednastavenie 5 pre LiFePO4 m\u00e1 kompenz\u00e1ciu 0 mV\/A<\/strong>. \u010eal\u0161\u00edm mo\u017en\u00fdm vysvetlen\u00edm ch\u00fdbaj\u00faceho videa je stav \u201eVypnut\u00e9\u201c nastaven\u00fd pod\u013ea \u010dasov\u00e9ho pl\u00e1nu alebo na z\u00e1klade osvetlenia.<\/p><p class=\"wp-block-paragraph\">Pr\u00edslu\u0161n\u00fd re\u0165azec udalost\u00ed je:<\/p><p class=\"wp-block-paragraph\"><strong>Bat\u00e9ria nap\u00e1ja kamery \u2192 regul\u00e1tor dosiahne \u00farove\u0148 LVD \u2192 odpoj\u00ed sa za\u0165a\u017eenie kamery \u2192 sol\u00e1rne nab\u00edjanie zv\u00fd\u0161i nap\u00e4tie bat\u00e9rie \u2192 regul\u00e1tor dosiahne \u00farove\u0148 LVR \u2192 kamery sa pok\u00fasia o re\u0161tart.<\/strong><\/p><p class=\"wp-block-paragraph\">Ak nap\u00e4tie op\u00e4\u0165 poklesne pri spusten\u00ed PoE prep\u00edna\u010da a kamier, zariadenie sa m\u00f4\u017ee op\u00e4\u0165 odpoji\u0165. Tento jav si vy\u017eaduje test re\u0161tartovania pod z\u00e1\u0165a\u017eou \u2013 nie predpoklad, \u017ee je bat\u00e9ria vybit\u00e1. Toto vy\u0161etrovanie obmedzte na <strong>Koordin\u00e1cia LVD a op\u00e4tovn\u00e9ho pripojenia<\/strong>; ak sa MPPT po odpojen\u00ed BMS nezapne, ide o in\u00fd diagnostick\u00fd probl\u00e9m.<\/p><h2 class=\"wp-block-heading\">Ako by mal v\u00fdrobca origin\u00e1lneho vybavenia (OEM) testova\u0165 LVD bez toho, aby do\u0161lo k ob\u00eddeniu ochrany bat\u00e9rie?<\/h2><p class=\"wp-block-paragraph\">Zoh\u013eadnite konkr\u00e9tny PoE prep\u00edna\u010d, verziu firmv\u00e9ru, rev\u00edziu balenia, nab\u00edja\u010dku, poistky, kabel\u00e1\u017e a za\u0165a\u017eenie kamery. Najsk\u00f4r overte <strong>kompatibilita s nab\u00edjan\u00edm<\/strong>: v technickom liste KMDPOWER je uveden\u00e1 hodnota <strong>Maxim\u00e1lne nab\u00edjacie nap\u00e4tie 15,6 V<\/strong>, zatia\u013e \u010do referen\u010dn\u00fd model spolo\u010dnosti Linovision <em>LiFePO4<\/em> profil ur\u010duje <strong>Nab\u00edjanie pri 14,4 V, ochrana proti prep\u00e4tiu na 15,0 V a ochrana proti nab\u00edjaniu pri n\u00edzkych teplot\u00e1ch 0 \u00b0C<\/strong>. Jeho limit nab\u00edjania je <strong>10A<\/strong>. Ide o <strong>neschv\u00e1len\u00e9 nastavenia pre sod\u00edkov\u00e9 i\u00f3ny<\/strong>; pred testovan\u00edm si u oboch v\u00fdrobcov overte programovate\u013en\u00e9 limity, profil nab\u00edjania schv\u00e1len\u00fd pre dan\u00fa bat\u00e9riu a teplotn\u00e9 spr\u00e1vanie. Samotn\u00fd laborat\u00f3rny zdroj nedok\u00e1\u017ee potvrdi\u0165 v\u00fddr\u017e bat\u00e9riov\u00e9ho modulu.<\/p><p class=\"wp-block-paragraph\"><strong>Krok 1 \u2014 Ur\u010dite v\u0161etky nap\u00e4\u0165ov\u00e9 limity.<\/strong> Zaznamenajte hodnoty LVD\/LVR, detek\u010dn\u00fd bod, tolerancie, oneskorenia a harmonogram za\u0165a\u017eenia. Overte <strong>Limit nab\u00edjania 15,6 V<\/strong>, schv\u00e1len\u00e9 pravidl\u00e1 nab\u00edjania na z\u00e1klade porovnania pr\u00fadu a teploty, nastavenia syst\u00e9mu BMS bat\u00e9rie a minim\u00e1lny vstupn\u00fd pr\u00fad meni\u010da. \u0160tandardn\u00fd postup CC\/CV pri 15,6 V uveden\u00fd v technickom liste je stanoven\u00fd pre <strong>0\u201345 \u00b0C<\/strong>; pred kvalifik\u00e1ciou je potrebn\u00e9 objasni\u0165 nastavenia nab\u00edjania mimo tohto rozsahu.<\/p><p class=\"wp-block-paragraph\"><strong>Krok 2 \u2014 Zmerajte nap\u00e4tie na dvoch miestach.<\/strong> Zaznamenajte svorky bat\u00e9rie a vstup regul\u00e1tora pri skuto\u010dnom za\u0165a\u017een\u00ed PoE, spolu s <strong>\u010dist\u00fd pr\u00fad bat\u00e9rie<\/strong>, teplota, re\u017eim regul\u00e1tora, v\u00fdstupn\u00fd v\u00fdkon PoE a dostupnos\u0165 kamery. Zoh\u013eadnite infra\u010derven\u00e9 \u017eiarenie, ohrieva\u010de a \u0161tartovaciu spotrebu. Pozna\u010dte si prv\u00e9 preru\u0161enie a uve\u010fte, \u010di ide o LVD, pl\u00e1n za\u0165a\u017eenia alebo vypnutie z d\u00f4vodu prekro\u010denia energetick\u00e9ho rozpo\u010dtu. <a href=\"https:\/\/whitepapers.axis.com\/en-us\/typical-and-maximum-power-consumption-in-axis-cameras\" target=\"_blank\" rel=\"noopener\">Pokyny spolo\u010dnosti AXIS t\u00fdkaj\u00face sa spotreby energie<\/a>.<\/p><p class=\"wp-block-paragraph\"><strong>Krok 3 \u2014 Pou\u017eite schv\u00e1len\u00fd postup riaden\u00e9ho vyp\u00fa\u0161\u0165ania.<\/strong> Za\u010dnite s zdokumentovan\u00fdm po\u010diato\u010dn\u00fdm stavom bat\u00e9rie. Udr\u017eujte pod kontrolou za\u0165a\u017eenie a teplotu. Zastavte sa pri prvom dosiahnutom syst\u00e9movom limite. Nevytv\u00e1rajte skrat, neobch\u00e1dzajte syst\u00e9m, ru\u010dne nevyvol\u00e1vajte vypnutie BMS a nepokra\u010dujte mimo schv\u00e1len\u00e9ho rozsahu vyb\u00edjania.<\/p><p class=\"wp-block-paragraph\"><strong>Krok 4 \u2014 Overte hypot\u00e9zu o zost\u00e1vaj\u00facej energii.<\/strong> V s\u00falade so schv\u00e1len\u00fdm pl\u00e1nom testovania porovnajte hodnotu Wh na strane bat\u00e9rie a hodnotu Wh na strane kamery pri zhodnom za\u0165a\u017een\u00ed, teplote a po\u010diato\u010dn\u00fdch podmienkach. Zoh\u013eadnite sol\u00e1rny pr\u00edkon; meranie nap\u00e4tia po odpojen\u00ed nie je testom kapacity. Test ukon\u010dite sk\u00f4r, ako d\u00f4jde k prekro\u010deniu ak\u00e9hoko\u013evek limitu zariadenia alebo bat\u00e9rie.<\/p><p class=\"wp-block-paragraph\"><strong>Krok 5 \u2014 Overte obnovenie.<\/strong> Obnovte schv\u00e1len\u00fd zdroj nap\u00e1jania. Zaznamenajte bod op\u00e4tovn\u00e9ho pripojenia regul\u00e1tora a prechodn\u00fd stav pri spusten\u00ed kamery. Opakujte tento postup pri pr\u00edslu\u0161nej teplote projektu a po zoh\u013eadnen\u00ed re\u00e1lnych str\u00e1t v k\u00e1bloch a konektoroch.<\/p><p class=\"wp-block-paragraph\">V z\u00e1zname by sa malo rozli\u0161ova\u0165 <strong>kontrol\u00e9r LVD, pl\u00e1novan\u00e9\/denn\u00e9 odpojenie z\u00e1\u0165a\u017ee, nedostato\u010dn\u00fd v\u00fdkonov\u00fd rozpo\u010det PoE alebo podnap\u00e4tie meni\u010da, ochrana BMS a nedostato\u010dn\u00e9 mno\u017estvo dostupnej energie<\/strong>. Vy\u017eaduj\u00fa si r\u00f4zne opravy.<\/p><h2 class=\"wp-block-heading\">Mal by v\u00fdrobca OEM vymeni\u0165 PoE prep\u00edna\u010d, jeho nastavenia alebo bat\u00e9riu?<\/h2><p class=\"wp-block-paragraph\">Rozhodnutie o k\u00fape z\u00e1vis\u00ed od overenej pr\u00ed\u010diny \u2013 nie od preferencie sod\u00edko-i\u00f3nov\u00fdch bat\u00e9ri\u00ed, LiFePO4 alebo akejko\u013evek inej chemickej zlo\u017eky.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>V\u00fdsledok testu<\/th><th>Vhodn\u00e9 \u010fal\u0161ie rozhodnutie<\/th><\/tr><\/thead><tbody><tr><td>D\u00f4jde k v\u010dasnej aktiv\u00e1cii ochrany LVD; profil schv\u00e1len\u00fd v\u00fdrobcom zost\u00e1va v r\u00e1mci v\u0161etk\u00fdch limitov<\/td><td>Nastavenia je potrebn\u00e9 spresni\u0165 s oh\u013eadom na nameran\u00fa rezervu a rezervu na op\u00e4tovn\u00e9 spustenie<\/td><\/tr><tr><td>LVD\/LVR alebo <strong>profil nab\u00edjania<\/strong> nie je kompatibiln\u00fd s bal\u00edkom exact<\/td><td>Vyberte kompatibiln\u00fd regul\u00e1tor alebo architekt\u00faru s ochranou nap\u00e1jania; nepreberajte predvolen\u00e9 nastavenia pre LiFePO4<\/td><\/tr><tr><td>Do\u0161lo k prekro\u010deniu nap\u00e1jacieho rozpo\u010dtu PoE alebo sa ako prv\u00e9 poru\u0161\u00ed vstupn\u00e9 nap\u00e4tie meni\u010da<\/td><td>Upravte vz\u0165ah medzi za\u0165a\u017een\u00edm a v\u00fdkonom; dodato\u010dn\u00e1 kapacita bat\u00e9rie v Ah nie je prv\u00fdm rie\u0161en\u00edm<\/td><\/tr><tr><td>Najsk\u00f4r sa aktivuje ochrana proti vybit\u00ed syst\u00e9mu BMS, inak by nameran\u00fd akumul\u00e1torov\u00fd blok nedok\u00e1zal splni\u0165 po\u017eadovan\u00fa rezervu<\/td><td>Prehodnoti\u0165 presn\u00fd bal\u00edk, limity pr\u00fadu a teploty, vyu\u017eite\u013en\u00fa energiu v Wh a energetick\u00e9 po\u017eiadavky syst\u00e9mu<\/td><\/tr><tr><td>Webov\u00e1 str\u00e1nka sa nedok\u00e1\u017ee op\u00e4tovne pripoji\u0165 alebo je deaktivovan\u00e1 na z\u00e1klade \u010dasov\u00e9ho pl\u00e1nu\/re\u017eimu \u00faspory energie<\/td><td>Skontrolujte hyster\u00e9zu, \u0161tartovac\u00ed pr\u00fad, pokles nap\u00e4tia a re\u017eim regul\u00e1cie za\u0165a\u017eenia<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Paraleln\u00e9 roz\u0161\u00edrenie schv\u00e1len\u00e9 v\u00fdrobcom m\u00f4\u017ee zv\u00fd\u0161i\u0165 v\u00fdkon a zn\u00ed\u017ei\u0165 za\u0165a\u017eenie na jeden modul, \u010d\u00edm sa m\u00f4\u017ee zn\u00ed\u017ei\u0165 pokles nap\u00e4tia. To <strong>nemen\u00ed menovit\u00e9 nap\u00e4tie v sieti<\/strong> alebo opravte nekompatibiln\u00e9 nastavenie LVD alebo profil nab\u00edjania. V\u00e4\u010d\u0161ia bat\u00e9riov\u00e1 banka tie\u017e nezvy\u0161uje sol\u00e1rny nab\u00edjac\u00ed pr\u00fad. Pred pridan\u00edm bat\u00e9riov\u00fdch bal\u00edkov prepo\u010d\u00edtajte nameran\u00e9 hodnoty v Wh a dobu nab\u00edjania.<\/p><p class=\"wp-block-paragraph\">Z\u00e1znam rozhodnutia OEM mus\u00ed obsahova\u0165 inform\u00e1cie o firmv\u00e9ri sp\u00edna\u010da, nastaveniach nab\u00edjania, LVD\/LVR, rev\u00edzii akumul\u00e1tora, nameran\u00fdch Wh, rozpo\u010dte za\u0165a\u017eenia a rezervu na re\u0161tart. \u0160ir\u0161\u00ed kontext n\u00e1jdete v <a href=\"https:\/\/www.kmdpower.com\/sk\/news\/12v-100ah-sodium-ion-battery-for-security-systems\/\">Vyu\u017eitie bezpe\u010dnostn\u00e9ho syst\u00e9mu Kamada Power 12 V<\/a>; ot\u00e1zka znie <strong>\u010di riadiaca jednotka spr\u00edstup\u0148uje kamer\u00e1m vyu\u017eite\u013en\u00fa energiu z akumul\u00e1tora<\/strong>.<\/p><h2 class=\"wp-block-heading\">\u010casto kladen\u00e9 ot\u00e1zky<\/h2><h3 class=\"wp-block-heading\">M\u00f4\u017ee sa sol\u00e1rny PoE prep\u00edna\u010d odpoji\u0165, aj ke\u010f syst\u00e9m BMS st\u00e1le povo\u013euje vyb\u00edjanie?<\/h3><p class=\"wp-block-paragraph\">\u00c1no. Vlastn\u00fd LVD regul\u00e1tora m\u00f4\u017ee odstr\u00e1ni\u0165 za\u0165a\u017eenie kamery sk\u00f4r, ako sa akumul\u00e1tor dostane do stavu ochrany BMS proti podp\u00e4t\u00ed. \u010ci zostane v\u00fdznamn\u00e9 mno\u017estvo dodato\u010dnej energie v Wh, je potrebn\u00e9 zmera\u0165 za schv\u00e1len\u00fdch podmienok.<\/p><h3 class=\"wp-block-heading\">Je vy\u0161\u0161ie nap\u00e4tie bat\u00e9rie po vypnut\u00ed d\u00f4kazom toho, \u017ee bat\u00e9ria nebola vybit\u00e1?<\/h3><p class=\"wp-block-paragraph\">Nie. Nap\u00e4tie sa m\u00f4\u017ee po odpojen\u00ed z\u00e1\u0165a\u017ee op\u00e4\u0165 zv\u00fd\u0161i\u0165. Bez v\u00fdstupnej krivky, \u00fadajov o pr\u00fade, teplote a z\u00e1znamu udalost\u00ed regul\u00e1tora t\u00e1to hodnota neumo\u017e\u0148uje ur\u010di\u0165 zost\u00e1vaj\u00facu vyu\u017eite\u013en\u00fa energiu.<\/p><h3 class=\"wp-block-heading\">M\u00f4\u017eem jednoducho zn\u00ed\u017ei\u0165 hodnotu LVD na vyp\u00ednacie nap\u00e4tie syst\u00e9mu BMS bat\u00e9rie?<\/h3><p class=\"wp-block-paragraph\">Nie. V prilo\u017eenom technickom liste produktu Kamada Power sa uv\u00e1dza, \u017ee <strong>Hranica vybitia 8 V nie je odpor\u00fa\u010danou hodnotou LVD<\/strong>. Dodr\u017eujte presn\u00e9 limity pre bat\u00e9rie a vybavenie, pri\u010dom zoh\u013eadnite overen\u00fa rezervu pre pokles nap\u00e4tia, minim\u00e1lny vstupn\u00fd v\u00fdkon meni\u010da a dobu zotavenia.<\/p><h3 class=\"wp-block-heading\">Pre\u010do sa kamera nespust\u00ed hne\u010f, ako vyjde slnko?<\/h3><p class=\"wp-block-paragraph\">Ovl\u00e1da\u010d m\u00f4\u017ee vy\u017eadova\u0165 vy\u0161\u0161ie nap\u00e4tie pri op\u00e4tovnom pripojen\u00ed, \u010dasov\u00e9 oneskorenie alebo splnenie in\u00fdch podmienok. Sol\u00e1rna energia tie\u017e nemus\u00ed sta\u010di\u0165 na to, aby po op\u00e4tovnom pripojen\u00ed zabezpe\u010dila spustenie kamery. Po\u010das obnovy merajte nap\u00e4tie aj pr\u00fad.<\/p><h3 class=\"wp-block-heading\">Vyrie\u0161i pridanie \u010fal\u0161ej 100 Ah bat\u00e9rie probl\u00e9m s pred\u010dasn\u00fdm spusten\u00edm LVD?<\/h3><p class=\"wp-block-paragraph\">Nie nevyhnutne. Schv\u00e1len\u00e9 paraleln\u00e9 sady zvy\u0161uj\u00fa v\u00fdkon a m\u00f4\u017eu zmierni\u0165 pokles nap\u00e4tia, av\u0161ak nastavenia LVD a nab\u00edja\u010dky na\u010falej platia. Pred roz\u0161\u00edren\u00edm syst\u00e9mu skontrolujte kompatibilitu prahov\u00fdch hodn\u00f4t a nab\u00edjac\u00ed v\u00fdkon.<\/p><h2 class=\"wp-block-heading\">Z\u00e1ver<\/h2><p class=\"wp-block-paragraph\">Sol\u00e1rny PoE prep\u00edna\u010d <strong>m\u00f4\u017ee<\/strong> odpoji\u0165 spotrebi\u010de nap\u00e1jan\u00e9 z kamerov\u00e9ho syst\u00e9mu e\u0161te predt\u00fdm, ako sod\u00edko-i\u00f3nov\u00e1 bat\u00e9ria dosiahne hranicu ochrany stanoven\u00fa syst\u00e9mom BMS. Mno\u017estvo energie, ku ktorej nebude mo\u017en\u00e9 z\u00edska\u0165 pr\u00edstup, z\u00e1vis\u00ed od <strong>meran\u00e9 Wh<\/strong>, LVD\/LVR, limit za\u0165a\u017eenia, straty v kabel\u00e1\u017ei a op\u00e4tovn\u00e9 spustenie \u2013 nie len vypnutie pri 8 V alebo nomin\u00e1lna hodnota 1 200 Wh. Najsk\u00f4r overte kompatibilitu nab\u00edjania, najm\u00e4 <strong>Obmedzenie nap\u00e4tia akumul\u00e1tora na 15,6 V<\/strong> v rozpore s programovate\u013en\u00fdm rozsahom a teplotn\u00fdmi poistkami prev\u00e1dzkovate\u013ea. Pre <a href=\"https:\/\/www.kmdpower.com\/sk\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria Kamada Power 12 V, 100 Ah<\/a>, <a href=\"https:\/\/www.kmdpower.com\/sk\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">kontaktujte spolo\u010dnos\u0165 Kamada Power<\/a> s modelom PoE, nastaveniami nab\u00edjania\/LVD\/LVR, za\u0165a\u017een\u00edm, teplotami a o\u010dak\u00e1van\u00fdm objemom. Pred n\u00e1kupom si vy\u017eiadajte pl\u00e1n testov kompatibility \u0161pecifick\u00fd pre dan\u00fa rev\u00edziu.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vzdialen\u00e9 miesto s kamerov\u00fdm syst\u00e9mom prestane nahr\u00e1va\u0165 e\u0161te pred \u00fasvitom. Sol\u00e1rny PoE prep\u00edna\u010d hl\u00e1si vypnutie kv\u00f4li n\u00edzkej \u00farovni nabitia bat\u00e9rie, av\u0161ak sod\u00edkovo-i\u00f3nov\u00fd akumul\u00e1torov\u00fd modul sa nedostal do stavu ochrany proti podp\u00e4t\u00ed syst\u00e9mu BMS. Je bat\u00e9ria nedostato\u010dne dimenzovan\u00e1, alebo prep\u00edna\u010d odpojil z\u00e1\u0165a\u017e pred\u010dasne? Sol\u00e1rny PoE prep\u00edna\u010d m\u00f4\u017ee odpoji\u0165 kamery e\u0161te predt\u00fdm, ako akumul\u00e1torov\u00fd modul dosiahne limit vybitia, av\u0161ak nap\u00e4tie\u2026<\/p>","protected":false},"author":1,"featured_media":1181,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5305","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5305","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/comments?post=5305"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5305\/revisions"}],"predecessor-version":[{"id":5307,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5305\/revisions\/5307"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media?parent=5305"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/categories?post=5305"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/tags?post=5305"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}