{"id":5238,"date":"2026-06-16T07:08:32","date_gmt":"2026-06-16T07:08:32","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5238"},"modified":"2026-06-16T07:08:34","modified_gmt":"2026-06-16T07:08:34","slug":"how-to-expand-48v-sodium-ion-battery-storage-without-soc-imbalance","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sk\/news\/how-to-expand-48v-sodium-ion-battery-storage-without-soc-imbalance\/","title":{"rendered":"Ako roz\u0161\u00edri\u0165 \u00falo\u017eisko 48 V sod\u00edkov\u00fdch bat\u00e9ri\u00ed bez naru\u0161enia vyv\u00e1\u017eenosti stavu nabitia (SOC)"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Roz\u0161\u00edrenie a <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/produkt\/kamada-power-10kwh-home-sodium-battery\/\" target=\"_blank\" rel=\"noreferrer noopener\">48 V sod\u00edkovo-i\u00f3nov\u00fd akumula\u010dn\u00fd syst\u00e9m<\/a><\/strong> nejde len o to, \u017ee by sa paralelne pripojil \u010fal\u0161\u00ed akumul\u00e1tor. V\u00e4\u010d\u0161\u00ed po\u010det akumul\u00e1torov m\u00f4\u017ee pred\u013a\u017ei\u0165 dobu z\u00e1lohovania, ale m\u00f4\u017ee tie\u017e sp\u00f4sobi\u0165 nerovnov\u00e1hu stavu nabitia (SOC), nerovnomern\u00e9 rozdelenie pr\u00fadu, pred\u010dasn\u00fa aktiv\u00e1ciu ochrany BMS, nepresn\u00e9 zobrazenie doby prev\u00e1dzky a s\u0165a\u017ei\u0165 obnovenie po hlbokom vybit\u00ed.<\/p><p class=\"wp-block-paragraph\">Ke\u010f\u017ee sa sod\u00edkov\u00e9 bat\u00e9rie l\u00ed\u0161ia od oloven\u00fdch alebo LiFePO4 bat\u00e9ri\u00ed v krivke nap\u00e4tia, mapovan\u00ed stavu nabitia (SOC), nab\u00edjan\u00ed pri n\u00edzkych teplot\u00e1ch a logike syst\u00e9mu riadenia bat\u00e9ri\u00ed (BMS), ozna\u010denie \u201epodporuje 48 V bat\u00e9riu\u201c nemus\u00ed v\u017edy znamena\u0165, \u017ee zariadenie je pripraven\u00e9 na roz\u0161\u00edrenie.<\/p><p class=\"wp-block-paragraph\">K\u013e\u00fa\u010dovou ot\u00e1zkou je, \u010di va\u0161a roz\u0161\u00edren\u00e1 bat\u00e9ria dok\u00e1\u017ee nab\u00edja\u0165, vyb\u00edja\u0165, signalizova\u0165 poruchu, obmedzova\u0165 v\u00fdkon a zotavova\u0165 sa ako jeden koordinovan\u00fd syst\u00e9m.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003.jpg\" alt=\"\" class=\"wp-image-4481\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003.jpg 1000w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-300x300.jpg 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-150x150.jpg 150w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-768x768.jpg 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-12x12.jpg 12w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-600x600.jpg 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-48v-210ah-10kWh-Home-Sodium-Battery-main-003-100x100.jpg 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/produkt\/kamada-power-10kwh-home-sodium-battery\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sod\u00edkov\u00e1 bat\u00e9ria Kamada Power 48 V, 200 Ah, 10 kWh<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Za\u010dnite s existuj\u00facimi hranicami syst\u00e9mu<\/h2><p class=\"wp-block-paragraph\">Predt\u00fdm, ako zv\u00fd\u0161ite kapacitu, si najprv ujasnite, ako vlastne funguje v\u00e1\u0161 s\u00fa\u010dasn\u00fd 48 V syst\u00e9m.<\/p><p class=\"wp-block-paragraph\">\u013dahk\u00e1 z\u00e1lo\u017en\u00e1 bat\u00e9ria sa l\u00ed\u0161i od akumul\u00e1tora pripojen\u00e9ho k meni\u010du, telekomunika\u010dn\u00e9mu usmer\u0148ova\u010du, sol\u00e1rnemu syst\u00e9mu mimo siete, nap\u00e1jaciemu syst\u00e9mu karavanu, mobilnej ve\u017ei CCTV, skladov\u00e9mu zariadeniu alebo priemyseln\u00e9mu za\u0165a\u017eeniu.<\/p><p class=\"wp-block-paragraph\">V\u00e1\u0161 projekt m\u00f4\u017ee vy\u017eadova\u0165 dlh\u0161iu dobu z\u00e1lohovania, vy\u0161\u0161\u00ed \u0161pi\u010dkov\u00fd pr\u00fad, lep\u0161iu regener\u00e1ciu pri n\u00edzkych teplot\u00e1ch alebo v\u00e4\u010d\u0161iu auton\u00f3miu po\u010das zamra\u010den\u00fdch dn\u00ed. Je v\u0161ak mo\u017en\u00e9, \u017ee kapacita bat\u00e9rie nebude pre v\u00e1\u0161 syst\u00e9m \u017eiadnym obmedzen\u00edm. Obmedzen\u00edm m\u00f4\u017ee by\u0165 nab\u00edja\u010dka, meni\u010d, vedenie k\u00e1blov, nastavenie ochrany alebo pr\u00fadov\u00e9 obmedzenie syst\u00e9mu BMS.<\/p><p class=\"wp-block-paragraph\">Preto by sa roz\u0161irovanie malo za\u010d\u00edna\u0165 od skuto\u010dn\u00e9ho limitu syst\u00e9mu, a nie len od t\u00fa\u017eby po v\u00e4\u010d\u0161om po\u010dte Ah.<\/p><p class=\"wp-block-paragraph\">Ak sa v\u00e1\u0161 meni\u010d vypne kv\u00f4li poklesu nap\u00e4tia, \u010fal\u0161\u00ed akumul\u00e1torov\u00fd blok m\u00f4\u017ee pom\u00f4c\u0165 len vtedy, ak sa zlep\u0161\u00ed rozdelenie pr\u00fadu. Ak va\u0161a nab\u00edja\u010dka nedok\u00e1\u017ee obnovi\u0165 stav akumul\u00e1torov\u00e9ho bloku po hlbokom vybit\u00ed, pridanie \u010fal\u0161\u00edch blokov m\u00f4\u017ee obnovenie spomali\u0165. Ak jeden blok u\u017e pred\u010dasne dosiahne stav ochrany, roz\u0161\u00edrenie syst\u00e9mu m\u00f4\u017ee tento probl\u00e9m sk\u00f4r zakry\u0165, ako ho vyrie\u0161i\u0165.<\/p><p class=\"wp-block-paragraph\">Pred schv\u00e1len\u00edm by mal v\u00e1\u0161 dod\u00e1vate\u013e bat\u00e9ri\u00ed skontrolova\u0165 model bat\u00e9rie, vek bat\u00e9riov\u00e9ho modulu, model nab\u00edja\u010dky alebo meni\u010da, nastavenia nab\u00edjania, \u0161pi\u010dkov\u00e9 za\u0165a\u017eenie, rozlo\u017eenie k\u00e1blov, teplotn\u00fd rozsah, komunika\u010dn\u00e9 po\u017eiadavky a cie\u013eov\u00fa hodnotu z\u00e1lo\u017en\u00e9ho nap\u00e1jania.<\/p><h2 class=\"wp-block-heading\">Nerovnov\u00e1ha v syst\u00e9me SOC sa zvy\u010dajne objav\u00ed e\u0161te pred in\u0161tal\u00e1ciou nov\u00e9ho bal\u00edka<\/h2><p class=\"wp-block-paragraph\">Nerovnov\u00e1ha v syst\u00e9me SOC sa nemus\u00ed v\u017edy prejavi\u0165 a\u017e po nieko\u013ek\u00fdch mesiacoch pou\u017e\u00edvania. M\u00f4\u017ee sa objavi\u0165 u\u017e v prv\u00fd de\u0148 in\u0161tal\u00e1cie.<\/p><p class=\"wp-block-paragraph\">Ak je nov\u00fd akumul\u00e1tor pripojen\u00fd pri inom nap\u00e4t\u00ed alebo stave nabitia (SOC) ako existuj\u00faci akumul\u00e1tor, medzi akumul\u00e1tormi m\u00f4\u017ee preteka\u0165 vyrovn\u00e1vac\u00ed pr\u00fad. Tento pr\u00fad nie je v\u017edy riaden\u00fd nab\u00edja\u010dkou a m\u00f4\u017ee ob\u00eds\u0165 be\u017en\u00fd nab\u00edjac\u00ed re\u017eim, s ktor\u00fdm po\u010d\u00edta syst\u00e9m BMS.<\/p><p class=\"wp-block-paragraph\">To je obzvl\u00e1\u0161\u0165 riskantn\u00e9 v pr\u00edpade, ak sa k star\u0161ej 48 V bat\u00e9riovej zostave pripoj\u00ed nov\u00fd akumul\u00e1tor.<\/p><p class=\"wp-block-paragraph\">Existuj\u00faca bat\u00e9ria mohla starn\u00fa\u0165, mohlo d\u00f4js\u0165 k odch\u00fdlke v odhade stavu nabitia (SOC) alebo sa v nej mohol zv\u00fd\u0161i\u0165 vn\u00fatorn\u00fd odpor. Nov\u00e1 bat\u00e9ria m\u00f4\u017ee ma\u0165 tie\u017e odli\u0161n\u00fd firmv\u00e9r, kalibr\u00e1ciu, spr\u00e1vanie sa \u0161ar\u017ee \u010dl\u00e1nkov alebo hist\u00f3riu skladovania.<\/p><p class=\"wp-block-paragraph\">Rovnak\u00e9 menovit\u00e9 nap\u00e4tie neznamen\u00e1 rovnak\u00fd prev\u00e1dzkov\u00fd stav.<\/p><p class=\"wp-block-paragraph\">Bezpe\u010dnej\u0161ou strat\u00e9giou je nastavi\u0165 bat\u00e9rie na kompatibiln\u00fd rozsah nap\u00e4tia a stavu nabitia (SOC) v s\u00falade s pravidlami dod\u00e1vate\u013ea pre paraleln\u00e9 zapojenie. V\u00e1\u0161 dod\u00e1vate\u013e by mal tie\u017e potvrdi\u0165, \u010di je povolen\u00e9 paraleln\u00e9 zapojenie star\u00fdch a nov\u00fdch bat\u00e9ri\u00ed, bat\u00e9ri\u00ed z r\u00f4znych s\u00e9ri\u00ed alebo s r\u00f4znymi verziami syst\u00e9mu BMS.<\/p><p class=\"wp-block-paragraph\">V pr\u00edpade 48 V sod\u00edko-i\u00f3nov\u00fdch syst\u00e9mov neschva\u013eujte roz\u0161\u00edrenie len na z\u00e1klade toho, \u017ee obe bat\u00e9rie s\u00fa ozna\u010den\u00e9 ako \u201e48 V\u201c. Nab\u00edjacie nap\u00e4tie, obmedzenie pr\u00fadu, pravidl\u00e1 nab\u00edjania v z\u00e1vislosti od teploty, vypnutie pri vyb\u00edjan\u00ed, logika prebudenia a komunik\u00e1cia musia zodpoveda\u0165 overen\u00fdm limitom bat\u00e9riov\u00e9ho modulu.<\/p><h2 class=\"wp-block-heading\">Rozdelenie pr\u00fadu z\u00e1vis\u00ed od odporu, nie od dobr\u00fdch \u00famyslov<\/h2><p class=\"wp-block-paragraph\">V paralelnom zapojen\u00ed akumul\u00e1torov sa pr\u00fad nerozde\u013euje rovnomerne len preto, \u017ee akumul\u00e1tory maj\u00fa uveden\u00e9 rovnak\u00e9 nap\u00e4tie.<\/p><p class=\"wp-block-paragraph\">Pr\u00fad te\u010die cestou s ni\u017e\u0161\u00edm odporom. T\u00fato cestu ovplyv\u0148uj\u00fa vn\u00fatorn\u00fd odpor, d\u013a\u017eka k\u00e1bla, svorky, kon\u0161trukcia zbernice, konektory, poistky, styka\u010de, teplota, stav nabitia (SOC) a spr\u00e1vanie syst\u00e9mu riadenia bat\u00e9rie (BMS).<\/p><p class=\"wp-block-paragraph\">Bat\u00e9ria s cestou s ni\u017e\u0161\u00edm odporom m\u00f4\u017ee vies\u0165 v\u00e4\u010d\u0161\u00ed vyb\u00edjac\u00ed pr\u00fad a prij\u00edma\u0165 v\u00e4\u010d\u0161\u00ed nab\u00edjac\u00ed pr\u00fad. V priebehu \u010dasu je t\u00e1to bat\u00e9ria za\u0165a\u017eovan\u00e1 viac ako ostatn\u00e9.<\/p><p class=\"wp-block-paragraph\">V pr\u00edpade 48 V sod\u00edko-i\u00f3nov\u00fdch bat\u00e9riov\u00fdch blokov je symetria k\u00e1blov s\u00fa\u010das\u0165ou kon\u0161trukcie syst\u00e9mu. Ak m\u00e1 jeden blok krat\u0161iu d\u013a\u017eku k\u00e1bla, \u010distej\u0161\u00ed konektor, ni\u017e\u0161\u00ed odpor poistky alebo lep\u0161\u00ed kontakt na svork\u00e1ch, m\u00f4\u017ee nies\u0165 v\u00e4\u010d\u0161ie za\u0165a\u017eenie, pri\u010dom sa to prejav\u00ed len ako jedna bat\u00e9riov\u00e1 banka.<\/p><p class=\"wp-block-paragraph\">D\u00f4sledky m\u00f4\u017eu by\u0165 z\u00e1va\u017en\u00e9. Jedna bat\u00e9ria r\u00fdchlej\u0161ie dosiahne ni\u017e\u0161iu \u00farove\u0148 nabitia (SOC), sk\u00f4r prejde do ochrann\u00e9ho re\u017eimu a ostatn\u00e9 bat\u00e9rie tak dostane bli\u017e\u0161ie k ich vlastn\u00fdm limitom.<\/p><p class=\"wp-block-paragraph\">Pri roz\u0161irovan\u00ed by sa nemalo kontrolova\u0165 len nap\u00e4tie a kapacita v Ah. Malo by sa skontrolova\u0165 aj usporiadanie vedenia, prierez k\u00e1blov, kon\u0161trukcia zbern\u00edc, poistky, svorky a teplotn\u00e9 podmienky.<\/p><h2 class=\"wp-block-heading\">Najzlo\u017eitej\u0161ie je prida\u0165 nov\u00fd bal\u00edk do starej banky<\/h2><p class=\"wp-block-paragraph\">Najjednoduch\u0161\u00edm sp\u00f4sobom roz\u0161\u00edrenia je pridanie identick\u00fdch bat\u00e9riov\u00fdch blokov na za\u010diatku projektu. Najzlo\u017eitej\u0161\u00edm sp\u00f4sobom roz\u0161\u00edrenia je pridanie nov\u00e9ho bat\u00e9riov\u00e9ho bloku do star\u0161ej bat\u00e9riovej s\u00fastavy.<\/p><p class=\"wp-block-paragraph\">Nov\u00e9 a star\u00e9 bat\u00e9rie sa m\u00f4\u017eu l\u00ed\u0161i\u0165 v pou\u017eite\u013enej kapacite, vn\u00fatornom odpore, odhade stavu nabitia (SOC), r\u00fdchlosti samovyb\u00edjania, firmv\u00e9ri syst\u00e9mu BMS, spr\u00e1van\u00ed pri vyva\u017eovan\u00ed, hist\u00f3rii tepl\u00f4t a hist\u00f3rii cyklov.<\/p><p class=\"wp-block-paragraph\">Star\u0161ia bat\u00e9ria m\u00f4\u017ee sk\u00f4r dosiahnu\u0165 stav ochrany proti n\u00edzkeho nap\u00e4tia. Nov\u00e1 bat\u00e9ria m\u00f4\u017ee nies\u0165 v\u00e4\u010d\u0161ie za\u0165a\u017eenie. Hodnoty stavu nabitia (SOC) na \u00farovni bat\u00e9rie u\u017e nemusia by\u0165 zhodn\u00e9.<\/p><p class=\"wp-block-paragraph\">To neznamen\u00e1, \u017ee roz\u0161\u00edrenie nie je mo\u017en\u00e9. Znamen\u00e1 to, \u017ee kompatibilita sa mus\u00ed pova\u017eova\u0165 za obmedzenie n\u00e1vrhu.<\/p><p class=\"wp-block-paragraph\">\u0160tandardn\u00e9 roz\u0161\u00edrenie je rozumnej\u0161ie v pr\u00edpade, ak s\u00fa bat\u00e9rie rovnak\u00e9ho modelu, maj\u00fa rovnak\u00fa nap\u00e4\u0165ov\u00fa platformu, verziu BMS, podobn\u00fd vek, podobn\u00fd stav nabitia (SOC) a s\u00fa nain\u0161talovan\u00e9 s kabel\u00e1\u017eou schv\u00e1lenou dod\u00e1vate\u013eom.<\/p><p class=\"wp-block-paragraph\">Individu\u00e1lne pos\u00fadenie je bezpe\u010dnej\u0161ie v pr\u00edpadoch, ke\u010f s\u00fa star\u00e9 a nov\u00e9 bat\u00e9rie zmie\u0161an\u00e9, ke\u010f sa l\u00ed\u0161ia kapacity, verzie firmv\u00e9ru alebo protokoly, alebo ke\u010f sa syst\u00e9m pou\u017e\u00edva na vysok\u00e9 za\u0165a\u017eenie meni\u010da, nab\u00edjanie za studena, dia\u013ekov\u00e9 z\u00e1lohovanie, telekomunika\u010dn\u00e9 skrine alebo priemyseln\u00fa prev\u00e1dzku.<\/p><h2 class=\"wp-block-heading\">Obmedzenia syst\u00e9mu BMS m\u00f4\u017eu sp\u00f4sobi\u0165 postupn\u00fa stratu kapacity<\/h2><p class=\"wp-block-paragraph\">Ka\u017ed\u00e1 sod\u00edkov\u00e1 bat\u00e9ria m\u00e1 svoje vlastn\u00e9 ochrann\u00e9 limity syst\u00e9mu BMS. Je to nevyhnutn\u00e9 z bezpe\u010dnostn\u00fdch d\u00f4vodov, av\u0161ak pri paralelnom prev\u00e1dzkovan\u00ed to m\u00f4\u017ee sp\u00f4sobi\u0165 aj neo\u010dak\u00e1van\u00e9 spr\u00e1vanie na \u00farovni syst\u00e9mu.<\/p><p class=\"wp-block-paragraph\">Ak u jedn\u00e9ho modulu d\u00f4jde ako prv\u00e9ho k aktiv\u00e1cii ochrany proti n\u00edzkeho nap\u00e4tiu, nadpr\u00fadovej ochrany, blokovania nab\u00edjania pri n\u00edzkej teplote, zn\u00ed\u017eenia v\u00fdkonu pri vysokej teplote alebo komunika\u010dn\u00e9ho alarmu, m\u00f4\u017ee to vies\u0165 k jeho odpojeniu alebo zn\u00ed\u017eeniu dostupnosti.<\/p><p class=\"wp-block-paragraph\">Akon\u00e1hle jedna skupina vypadne, zvy\u0161n\u00e9 skupiny musia nies\u0165 v\u00e4\u010d\u0161iu z\u00e1\u0165a\u017e. To ich m\u00f4\u017ee pribl\u00ed\u017ei\u0165 k ich vlastn\u00fdm limitom a sp\u00f4sobi\u0165, \u017ee skupina bude postupne str\u00e1ca\u0165 kapacitu.<\/p><p class=\"wp-block-paragraph\">Mo\u017eno by ste o\u010dak\u00e1vali jeden ve\u013ek\u00fd akumul\u00e1torov\u00fd blok. V skuto\u010dnosti sa v\u0161ak syst\u00e9m m\u00f4\u017ee spr\u00e1va\u0165 ako nieko\u013eko nez\u00e1visl\u00fdch akumul\u00e1torov\u00fdch blokov, ktor\u00e9 sa postupne zap\u00e1jaj\u00fa a odp\u00e1jaj\u00fa.<\/p><p class=\"wp-block-paragraph\">Ak meni\u010d, nab\u00edja\u010dka alebo regul\u00e1tor nerozpozn\u00e1 dostupnos\u0165 na \u00farovni akumul\u00e1torov\u00e9ho bloku, m\u00f4\u017ee sa akumul\u00e1torov\u00fd blok pred\u010dasne vypn\u00fa\u0165 alebo vykazova\u0165 nejasn\u00e9 spr\u00e1vanie v s\u00favislosti so stavom nabitia (SOC).<\/p><p class=\"wp-block-paragraph\">Toto riziko sa zvy\u0161uje pri vysokom za\u0165a\u017een\u00ed meni\u010da, n\u00edzkom stave nabitia (SOC), n\u00edzkych teplot\u00e1ch, dlh\u00fdch k\u00e1blov\u00fdch tras\u00e1ch a pri bat\u00e9ri\u00e1ch s r\u00f4znou hist\u00f3riou pou\u017e\u00edvania.<\/p><p class=\"wp-block-paragraph\">Spo\u013eahliv\u00fd roz\u0161\u00edren\u00fd syst\u00e9m by mal bezpe\u010dne pokra\u010dova\u0165 v prev\u00e1dzke, spr\u00e1vne sa obnovi\u0165 a ozna\u010di\u0165, ktor\u00fd modul sp\u00f4sobil dan\u00fa udalos\u0165.<\/p><h2 class=\"wp-block-heading\">Displej SOC m\u00f4\u017ee po roz\u0161\u00edren\u00ed strati\u0165 na spo\u013eahlivosti<\/h2><p class=\"wp-block-paragraph\">SOC nie je v\u017edy len jednoduch\u00e9 spolo\u010dn\u00e9 \u010d\u00edslo v s\u00fastave paraleln\u00fdch bat\u00e9ri\u00ed.<\/p><p class=\"wp-block-paragraph\">Ka\u017ed\u00fd akumul\u00e1tor m\u00f4\u017ee odhadova\u0165 stav nabitia (SOC) pomocou vlastn\u00e9ho algoritmu syst\u00e9mu riadenia akumul\u00e1tora (BMS). Tento odhad z\u00e1vis\u00ed od nap\u00e4tia, pr\u00fadu, teploty, hist\u00f3rie kalibr\u00e1cie, doby v pohotovostnom re\u017eime a predch\u00e1dzaj\u00facich cyklov.<\/p><p class=\"wp-block-paragraph\">Po roz\u0161\u00edren\u00ed m\u00f4\u017ee v\u00e1\u0161 syst\u00e9m zobrazova\u0165 jednu kombinovan\u00fa hodnotu SOC, jednu hodnotu SOC hlavn\u00e9ho akumul\u00e1tora, jednu hodnotu SOC odhadnut\u00fa meni\u010dom alebo nieko\u013eko hodn\u00f4t SOC na \u00farovni jednotliv\u00fdch akumul\u00e1torov. Tieto hodnoty sa nemusia zhodova\u0165.<\/p><p class=\"wp-block-paragraph\">T\u00e1to nezhoda nemus\u00ed v\u017edy znamena\u0165, \u017ee jeden akumul\u00e1tor je vadn\u00fd. M\u00f4\u017ee to s\u00favisie\u0165 s odli\u0161nou hist\u00f3riou akumul\u00e1torov, rozdelen\u00edm pr\u00fadu, odch\u00fdlkou merania, stratami v pohotovostnom re\u017eime alebo obmedzeniami odhadu stavu nabitia (SOC).<\/p><p class=\"wp-block-paragraph\">Ide o prev\u00e1dzkov\u00e9 nebezpe\u010denstvo.<\/p><p class=\"wp-block-paragraph\">Ak sa na displeji zobrazuje vysok\u00e1 hodnota SOC, pri\u010dom jeden akumul\u00e1tor sa bl\u00ed\u017ei k aktiv\u00e1cii ochrany, m\u00f4\u017ee d\u00f4js\u0165 k pred\u010dasnej poruche v\u00e1\u0161ho syst\u00e9mu. Ak sa na displeji zobrazuje n\u00edzka hodnota, hoci je e\u0161te k dispoz\u00edcii pou\u017eite\u013en\u00e1 energia, m\u00f4\u017ee v\u00e1\u0161 syst\u00e9m zbyto\u010dne m\u00ed\u0148a\u0165 kapacitu.<\/p><p class=\"wp-block-paragraph\">Ak meni\u010d prijme nespr\u00e1vne \u00fadaje o stave nabitia (SOC) alebo o obmedzen\u00ed pr\u00fadu, m\u00f4\u017ee bat\u00e9riov\u00fd blok nab\u00edja\u0165 alebo vyb\u00edja\u0165 sp\u00f4sobom, ktor\u00fd zvy\u0161uje nerovnov\u00e1hu.<\/p><p class=\"wp-block-paragraph\">Po roz\u0161\u00edren\u00ed by sa SOC mal pova\u017eova\u0165 za odhad syst\u00e9mu a overova\u0165 sa pri skuto\u010dnom nab\u00edjan\u00ed a vyb\u00edjan\u00ed, a nie spolieha\u0165 sa v\u00fdlu\u010dne na \u00fadaje na displeji.<\/p><h2 class=\"wp-block-heading\">Komunik\u00e1cia m\u00f4\u017ee nerovnov\u00e1he predch\u00e1dza\u0165 alebo ju zakry\u0165<\/h2><p class=\"wp-block-paragraph\">Paraleln\u00fd 48 V sod\u00edkovo-i\u00f3nov\u00fd akumul\u00e1torov\u00fd blok m\u00f4\u017ee fungova\u0165 ako jednoduch\u00e9 \u00falo\u017eisko energie zalo\u017een\u00e9 na nap\u00e4t\u00ed alebo ako inteligentnej\u0161\u00ed syst\u00e9m s komunik\u00e1ciou medzi jednotliv\u00fdmi blokmi alebo medzi blokom a meni\u010dom.<\/p><p class=\"wp-block-paragraph\">Komunik\u00e1cia pom\u00e1ha len vtedy, ak poskytuje u\u017eito\u010dn\u00e9 prev\u00e1dzkov\u00e9 \u00fadaje, ako s\u00fa stav nabitia bat\u00e9rie (SOC), nap\u00e4tie, pr\u00fad, teplota, v\u00fdstrahy, pr\u00fadov\u00e9 obmedzenia a stav pripojenia.<\/p><p class=\"wp-block-paragraph\">Samotn\u00fd port CAN alebo RS485 nezaru\u010duje koordin\u00e1ciu. O tom, \u010di syst\u00e9m skuto\u010dne rozumie tomu, \u010do rob\u00ed ka\u017ed\u00fd akumul\u00e1torov\u00fd blok, rozhoduj\u00fa protokol, d\u00e1tov\u00e1 mapa, logika master-slave, nastavenie adries, spr\u00e1vanie pri v\u00fdstrahe a kompatibilita s meni\u010dom.<\/p><p class=\"wp-block-paragraph\">V pr\u00edpade roz\u0161\u00edrenia by komunik\u00e1cia mala poskytova\u0165 odpovede na praktick\u00e9 ot\u00e1zky: Ktor\u00e9 bat\u00e9rie s\u00fa online? Ktor\u00e1 bat\u00e9ria obmedzuje pr\u00fad? Ktor\u00e1 bat\u00e9ria dosiahla ochrann\u00fa \u00farove\u0148? Dost\u00e1va meni\u010d spr\u00e1vnu hodnotu limitu?<\/p><p class=\"wp-block-paragraph\">Ak v\u00e1\u0161 syst\u00e9m nedok\u00e1\u017ee odpoveda\u0165 na tieto ot\u00e1zky, komunik\u00e1cia m\u00f4\u017ee sl\u00fa\u017ei\u0165 len na zobrazenie inform\u00e1ci\u00ed, nie na skuto\u010dn\u00e9 ovl\u00e1danie.<\/p><p class=\"wp-block-paragraph\">Komunik\u00e1cia m\u00f4\u017ee pom\u00f4c\u0165 zvl\u00e1dnu\u0165 nerovnov\u00e1hu, nem\u00f4\u017ee v\u0161ak nahradi\u0165 spr\u00e1vny elektrick\u00fd n\u00e1vrh. Dobr\u00e1 komunik\u00e1cia v kombin\u00e1cii so zl\u00fdm zapojen\u00edm st\u00e1le znamen\u00e1 nekvalitn\u00fd syst\u00e9m.<\/p><h2 class=\"wp-block-heading\">Po roz\u0161\u00edren\u00ed je potrebn\u00e9 op\u00e4tovne skontrolova\u0165 nastavenia nab\u00edja\u010dky a meni\u010da<\/h2><p class=\"wp-block-paragraph\">Zv\u00fd\u0161enie kapacity men\u00ed sp\u00f4sob nab\u00edjania a vyb\u00edjania v\u00e1\u0161ho syst\u00e9mu.<\/p><p class=\"wp-block-paragraph\">Nab\u00edja\u010dka m\u00f4\u017ee po hlbokom vybit\u00ed potrebova\u0165 viac \u010dasu na dobitie roz\u0161\u00edrenej bat\u00e9riovej skupiny. Ak je nab\u00edjac\u00ed pr\u00fad pr\u00edli\u0161 n\u00edzky, dob\u00edjanie prebieha pomaly. Ak je nab\u00edjac\u00ed pr\u00fad pr\u00edli\u0161 vysok\u00fd pre jeden akumul\u00e1torov\u00fd blok alebo vzh\u013eadom na sp\u00f4sob rozdelenia pr\u00fadu v bat\u00e9riovej skupine, jeden syst\u00e9m BMS m\u00f4\u017ee obmedzi\u0165 nab\u00edjanie sk\u00f4r ako ostatn\u00e9.<\/p><p class=\"wp-block-paragraph\">Ak jeden akumul\u00e1tor zablokuje nab\u00edjanie kv\u00f4li n\u00edzkej teplote alebo aktiv\u00e1cii ochrany, nab\u00edja\u010dka m\u00f4\u017ee aj napriek tomu vn\u00edma\u0165 akumul\u00e1torov\u00fa banku ako dostupn\u00fa. To m\u00f4\u017ee nerovnov\u00e1hu e\u0161te zhor\u0161i\u0165.<\/p><p class=\"wp-block-paragraph\">Je potrebn\u00e9 prehodnoti\u0165 aj stranu meni\u010da. V\u00e4\u010d\u0161ia bat\u00e9riov\u00e1 banka m\u00f4\u017ee vies\u0165 k v\u00e4\u010d\u0161iemu za\u0165a\u017eeniu, av\u0161ak syst\u00e9m riadenia bat\u00e9ri\u00ed (BMS), k\u00e1ble, poistky, svorky, styka\u010de a nastavenia vypnutia meni\u010da sa nemuseli zmeni\u0165.<\/p><p class=\"wp-block-paragraph\">Vy\u0161\u0161ia kapacita automaticky neznamen\u00e1 bezpe\u010dnej\u0161\u00ed vyb\u00edjac\u00ed pr\u00fad.<\/p><p class=\"wp-block-paragraph\">Pre <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/produkt\/kamada-power-10kwh-home-sodium-battery\/\" target=\"_blank\" rel=\"noreferrer noopener\">48 V sod\u00edko-i\u00f3nov\u00e9 bat\u00e9rie<\/a><\/strong>, nerozhodujte sa o roz\u0161\u00edren\u00ed len na z\u00e1klade toho, \u017ee na meni\u010de je uveden\u00e9 \u201epodpora 48 V bat\u00e9ri\u00ed\u201c. Pred roz\u0161\u00edren\u00edm si overte nab\u00edjacie nap\u00e4tie, limit nab\u00edjacieho pr\u00fadu, prah vybitia, pravidl\u00e1 nab\u00edjania pri n\u00edzkych teplot\u00e1ch, logiku prebudenia syst\u00e9mu BMS, kompatibilitu komunik\u00e1cie, \u0161pi\u010dkov\u00fd za\u0165a\u017eovac\u00ed pr\u00fad a menovit\u00fa hodnotu k\u00e1blov alebo poistiek.<\/p><p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sod\u00edkovo-i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong> Chovanie nap\u00e4tia, mapovanie stavu nabitia (SOC), pravidl\u00e1 pre prev\u00e1dzku pri n\u00edzkych teplot\u00e1ch a obmedzenia syst\u00e9mu BMS sa m\u00f4\u017eu l\u00ed\u0161i\u0165 od syst\u00e9mov s oloven\u00fdmi bat\u00e9riami alebo LiFePO\u2084.<\/p><h2 class=\"wp-block-heading\">Skuto\u010dn\u00e9 hranice expanzie<\/h2><p class=\"wp-block-paragraph\">Spr\u00e1vne roz\u0161\u00edrenie na 48 V z\u00e1vis\u00ed od hran\u00edc, ktor\u00e9 skuto\u010dne menia spr\u00e1vanie syst\u00e9mu.<\/p><p class=\"wp-block-paragraph\">Hlavn\u00fdmi obmedzeniami s\u00fa zos\u00faladenie bat\u00e9riov\u00e9ho modulu, odpor pripojenia, koordin\u00e1cia BMS, obnovenie nab\u00edja\u010dky, po\u017eiadavky meni\u010da, teplotn\u00fd rozdiel a komunika\u010dn\u00fd protokol.<\/p><p class=\"wp-block-paragraph\">Ak d\u00f4jde k zmene typu akumul\u00e1tora, firmv\u00e9ru, odporu, zapojenia, obmedzenia pr\u00fadu, profilu nab\u00edja\u010dky alebo prev\u00e1dzkovej teploty, v\u00e1\u0161 syst\u00e9m by sa nemal pova\u017eova\u0165 za jednoduch\u00e9 roz\u0161\u00edrenie kapacity prostredn\u00edctvom pripojenia \u010fal\u0161ieho akumul\u00e1tora.<\/p><p class=\"wp-block-paragraph\">V pr\u00edpade v\u00e1\u0161ho B2B projektu by sa tieto hranice mali potvrdi\u0165 e\u0161te pred vypracovan\u00edm cenovej ponuky. V opa\u010dnom pr\u00edpade m\u00f4\u017eete dosta\u0165 vy\u0161\u0161iu hodnotu Ah, hoci v\u00e1\u0161 projekt v skuto\u010dnosti vy\u017eaduje in\u00fa strat\u00e9giu riadenia bat\u00e9riov\u00e9ho syst\u00e9mu (BMS), sch\u00e9mu zapojenia, nastavenie nab\u00edja\u010dky alebo rev\u00edziu syst\u00e9mu.<\/p><h2 class=\"wp-block-heading\">\u0160tandardn\u00e9 roz\u0161\u00edrenie funguje iba za kontrolovan\u00fdch podmienok<\/h2><p class=\"wp-block-paragraph\">\u0160tandardn\u00e1 expanzia m\u00f4\u017ee prebieha\u0165 za kontrolovan\u00fdch podmienok.<\/p><p class=\"wp-block-paragraph\">Bat\u00e9rie by mali by\u0165 spravidla rovnak\u00e9ho modelu, s rovnakou nap\u00e4\u0165ovou platformou, rovnakou verziou BMS, podobn\u00fdm vekom, podobn\u00fdm stavom nabitia (SOC) a mali by by\u0165 nain\u0161talovan\u00e9 pomocou paraleln\u00e9ho zapojenia schv\u00e1len\u00e9ho dod\u00e1vate\u013eom.<\/p><p class=\"wp-block-paragraph\">Je to tie\u017e jednoduch\u0161ie, ak je za\u0165a\u017eenie stredn\u00e9, nastavenia nab\u00edja\u010dky s\u00fa spr\u00e1vne, teplota je pod kontrolou, je k dispoz\u00edcii monitorovanie stavu akumul\u00e1torov\u00e9ho modulu a komunik\u00e1cia s meni\u010dom je overen\u00e1.<\/p><p class=\"wp-block-paragraph\">Technicky sofistikovanej\u0161ie roz\u0161\u00edrenie je bezpe\u010dnej\u0161ie, ak syst\u00e9m vyu\u017e\u00edva vysok\u00e9 za\u0165a\u017eenie meni\u010da, nab\u00edjanie za studena, dlh\u00e9 k\u00e1blov\u00e9 trasy, star\u0161ie akumul\u00e1torov\u00e9 moduly, zmie\u0161an\u00e9 s\u00e9rie akumul\u00e1torov\u00fdch modulov, dia\u013ekov\u00e9 ovl\u00e1danie, telekomunika\u010dn\u00e9 skrine, rekuper\u00e1ciu sol\u00e1rnej energie alebo riadenie zalo\u017een\u00e9 na komunik\u00e1cii.<\/p><p class=\"wp-block-paragraph\">Tieto podmienky neznamenaj\u00fa, \u017ee roz\u0161\u00edrenie 48 V sod\u00edko-i\u00f3nov\u00fdch syst\u00e9mov nie je vhodn\u00e9. Znamenaj\u00fa v\u0161ak, \u017ee nerozv\u00e1\u017ene roz\u0161\u00edrenie je rizikov\u00e9.<\/p><p class=\"wp-block-paragraph\">Rozdiel nespo\u010d\u00edva v tom, \u010di je mo\u017en\u00e9 tieto akumul\u00e1torov\u00e9 bloky teoreticky zapoji\u0165 paralelne. Rozdiel spo\u010d\u00edva v tom, \u010di bola va\u0161a roz\u0161\u00edren\u00e1 akumul\u00e1torov\u00e1 banka certifikovan\u00e1 ako jeden 48 V akumula\u010dn\u00fd syst\u00e9m.<\/p><p class=\"wp-block-paragraph\">\u0160tandardn\u00e9 roz\u0161\u00edrenie sa zvy\u010dajne neodpor\u00fa\u010da v pr\u00edpadoch, ke\u010f s\u00fa v syst\u00e9me zmie\u0161an\u00e9 r\u00f4zne zna\u010dky alebo kapacity, star\u00e9 a nov\u00e9 bat\u00e9rie maj\u00fa ve\u013emi odli\u0161n\u00fa hist\u00f3riu cyklov, firmv\u00e9r syst\u00e9mu BMS je odli\u0161n\u00fd, profil nab\u00edjania meni\u010da nie je zn\u00e1my alebo syst\u00e9m pracuje bez dozoru v chladnom po\u010das\u00ed.<\/p><h2 class=\"wp-block-heading\">Overujte moment nerovnov\u00e1hy, nielen pridan\u00fa kapacitu<\/h2><p class=\"wp-block-paragraph\">Roz\u0161\u00edrenie \u00falo\u017eiska s 48 V sod\u00edkovo-i\u00f3nov\u00fdmi \u010dl\u00e1nkami by nemalo by\u0165 schv\u00e1len\u00e9 len preto, \u017ee nap\u00e4tie po pripojen\u00ed vyzer\u00e1 spr\u00e1vne.<\/p><p class=\"wp-block-paragraph\">Valid\u00e1cia by sa mala zamera\u0165 na situ\u00e1cie, v ktor\u00fdch doch\u00e1dza k nerovnov\u00e1he: prv\u00e9 paraleln\u00e9 zapojenie, vyb\u00edjanie pri vysokom za\u0165a\u017een\u00ed, prev\u00e1dzka pri n\u00edzkom stave nabitia (SOC), dob\u00edjanie po hlbokom vybit\u00ed, dob\u00edjanie za studena, aktiv\u00e1cia ochrany u jedn\u00e9ho akumul\u00e1tora, strata komunik\u00e1cie a obnovenie prev\u00e1dzky po odpojen\u00ed \u010dasti akumul\u00e1torov.<\/p><p class=\"wp-block-paragraph\">\u201e\u010cist\u00fd\u201c v\u00fdsledok znamen\u00e1, \u017ee rozdelenie pr\u00fadu zost\u00e1va v r\u00e1mci stanoven\u00e9ho rozsahu, nab\u00edja\u010dka dop\u013a\u0148a bat\u00e9riov\u00fd blok predv\u00eddate\u013en\u00fdm sp\u00f4sobom, hodnoty stavu nabitia (SOC) zost\u00e1vaj\u00fa v prijate\u013enom rozsahu a syst\u00e9m dok\u00e1\u017ee vysvetli\u0165, \u010do sa stalo, ak sa jeden blok odpoj\u00ed.<\/p><p class=\"wp-block-paragraph\">Na \u00fa\u010dely schv\u00e1lenia projektu skontrolujte nap\u00e4tie a stav nabitia (SOC) pred pripojen\u00edm, symetriu k\u00e1blov, po\u010diato\u010dn\u00fd pr\u00fad, rozlo\u017eenie pr\u00fadu, spr\u00e1vanie pri n\u00e1razov\u00fdch za\u0165a\u017eeniach, spr\u00e1vanie pri n\u00edzkom stave nabitia (SOC), dob\u00edjanie po aktiv\u00e1cii ochrany, povolenie nab\u00edjania pri n\u00edzkych teplot\u00e1ch, v\u00fdstra\u017en\u00e9 sign\u00e1ly a obnovenie po odpojen\u00ed jedn\u00e9ho modulu.<\/p><h2 class=\"wp-block-heading\">Z\u00e1ver<\/h2><p class=\"wp-block-paragraph\">Roz\u0161irovanie <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/produkt\/kamada-power-10kwh-home-sodium-battery\/\" target=\"_blank\" rel=\"noreferrer noopener\">48 V sod\u00edko-i\u00f3nov\u00e1 bat\u00e9ria<\/a><\/strong> Ukladanie energie bez naru\u0161enia rovnov\u00e1hy SOC si vy\u017eaduje viac ne\u017e len paraleln\u00e9 pripojenie \u010fal\u0161ieho akumul\u00e1tora.<\/p><p class=\"wp-block-paragraph\">Pred roz\u0161\u00edren\u00edm je potrebn\u00e9 zos\u00faladi\u0165 nap\u00e4tie bal\u00edka, stav nabitia (SOC), model, verziu firmv\u00e9ru, vek, odpor zapojenia, limity syst\u00e9mu BMS, nastavenia nab\u00edja\u010dky, po\u017eiadavky meni\u010da, teplotn\u00e9 podmienky a komunika\u010dn\u00fa logiku.<\/p><p class=\"wp-block-paragraph\">V pr\u00edpade projektov t\u00fdkaj\u00facich sa 48 V akumul\u00e1torov, <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kontaktujte spolo\u010dnos\u0165 Kamada Power<\/a><\/strong> s oh\u013eadom na model bat\u00e9rie, po\u010det bat\u00e9riov\u00fdch modulov, model meni\u010da, nastavenia nab\u00edja\u010dky, usporiadanie k\u00e1blov, prev\u00e1dzkov\u00fa teplotu, pr\u00edkon z\u00e1\u0165a\u017ee, komunika\u010dn\u00e9 po\u017eiadavky a po\u017eadovan\u00fa dobu z\u00e1lohovania. N\u00e1\u0161 technick\u00fd t\u00edm v\u00e1m pom\u00f4\u017ee zisti\u0165, \u010di je vhodn\u00e9 \u0161tandardn\u00e9 paraleln\u00e9 roz\u0161\u00edrenie, alebo \u010di je bezpe\u010dnej\u0161ie rie\u0161enie na b\u00e1ze sod\u00edko-i\u00f3nov\u00fdch bat\u00e9ri\u00ed koordinovan\u00e9 syst\u00e9mom BMS na mieru.<\/p><p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Roz\u0161\u00edrenie 48 V sod\u00edko-i\u00f3nov\u00e9ho akumul\u00e1torov\u00e9ho syst\u00e9mu neznamen\u00e1 len pridanie \u010fal\u0161ieho akumul\u00e1tora zapojen\u00e9ho paralelne. Viac bat\u00e9riov\u00fdch blokov m\u00f4\u017ee pred\u013a\u017ei\u0165 dobu z\u00e1lohovania, ale m\u00f4\u017ee tie\u017e sp\u00f4sobi\u0165 nerovnov\u00e1hu SOC, nerovnomern\u00e9 rozdelenie pr\u00fadu, pred\u010dasn\u00fa ochranu BMS, nepresn\u00e9 zobrazenie doby prev\u00e1dzky a \u0165a\u017ek\u00e9 zotavenie po hlbokom vybit\u00ed. Preto\u017ee sod\u00edkov\u00e9 bat\u00e9rie sa l\u00ed\u0161ia od oloven\u00fdch alebo LiFePO4 bat\u00e9ri\u00ed v krivke nap\u00e4tia, mapovan\u00ed SOC, n\u00edzkych teplot\u00e1ch...<\/p>","protected":false},"author":1,"featured_media":4481,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5238","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5238","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/comments?post=5238"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5238\/revisions"}],"predecessor-version":[{"id":5239,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/5238\/revisions\/5239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media\/4481"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media?parent=5238"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/categories?post=5238"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/tags?post=5238"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}