{"id":4440,"date":"2025-05-28T15:47:41","date_gmt":"2025-05-28T15:47:41","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=4440"},"modified":"2025-05-28T15:47:43","modified_gmt":"2025-05-28T15:47:43","slug":"difference-between-kva-and-kw","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/sk\/news\/difference-between-kva-and-kw\/","title":{"rendered":"Rozdiel medzi KVA a KW"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u00davod:<\/h2><p>Z\u00e1mena KVA a KW sp\u00f4sobuje u\u017e desa\u0165ro\u010dia n\u00e1kladn\u00e9 chyby pri n\u00e1vrhu energetick\u00fdch syst\u00e9mov - pochopenie tohto rozdielu je v\u0161ak jednoduch\u0161ie, ako si mysl\u00edte.<\/p><p>Ke\u010f\u017ee som str\u00e1vil viac ako 25 rokov z\u00e1pasen\u00edm s energetick\u00fdmi syst\u00e9mami, od robustn\u00fdch priemyseln\u00fdch bat\u00e9riov\u00fdch \u00falo\u017e\u00edsk a\u017e po \u0161pi\u010dkov\u00e9 integr\u00e1cie obnovite\u013en\u00fdch zdrojov energie, bol som priamym svedkom toho, ako toto nedorozumenie m\u00f4\u017ee zni\u010di\u0165 projekty, rozpo\u010dty a niekedy aj eg\u00e1.<\/p><p>Tento \u010dl\u00e1nok nie je len \u010fal\u0161\u00edm such\u00fdm technick\u00fdm textom. Som tu preto, aby som prekonal \u017earg\u00f3n, poskytol v\u00e1m jasn\u00e9 defin\u00edcie, praktick\u00e9 konverzie a pr\u00edbehy z re\u00e1lneho sveta, ktor\u00e9 odha\u013euj\u00fa be\u017en\u00e9 myln\u00e9 predstavy. A \u00e1no, spochybn\u00edm niektor\u00e9 zakorenen\u00e9 n\u00e1zory, preto\u017ee \u00faprimne povedan\u00e9, toto odvetvie si nechce prizna\u0165, ale my sme sa v \u00fa\u010dinn\u00edku m\u00fdlili vo viacer\u00fdch smeroch.<\/p><p>Tak\u017ee dimenzujete svoje zariadenie na \u00fa\u010dinnos\u0165 alebo na neo\u010dak\u00e1van\u00e9 n\u00e1klady? Po\u010fme na to.<\/p><div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"769\" height=\"790\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Kamada-Power-All-In-One-Solar-System-Suplier-Factory-Manufacturers-in-China-1.jpg\" alt=\"\" class=\"wp-image-4175\"\/><\/figure><\/div><p class=\"has-text-align-center\"><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/48v-200ah-10kwh-5kwh-lithium-lifepo4-batteryall-in-one-solar-storage-system-hybrid-system-built-in-inverter-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">48v 200Ah 10kWh V\u0161etko v jednom sol\u00e1rnom syst\u00e9me Hybridn\u00fd syst\u00e9m Zabudovan\u00fd meni\u010d<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">\u010co s\u00fa KVA a KW?<\/h2><h3 class=\"wp-block-heading\">\u010co je KW (kilowatt)?<\/h3><p>KW je skratka pre kilowatt - mieru <em>skuto\u010dn\u00e1 sila<\/em>. Je to sila, ktor\u00e1 skuto\u010dne vykon\u00e1va u\u017eito\u010dn\u00fa pr\u00e1cu. Ke\u010f zapnete ohrieva\u010d, mno\u017estvo elektriny, ktor\u00e9 sa premen\u00ed na teplo, sa meria v kilowattoch. Jednoduch\u00e9, v\u0161ak?<\/p><p>Pova\u017eujte KW za peniaze, ktor\u00e9 skuto\u010dne miniete na \u00fa\u010det za elektrinu. Je to <em>spotrebovan\u00e1 energia<\/em>, doslova \u0161\u0165ava poh\u00e1\u0148aj\u00faca motory, svetl\u00e1 a k\u00e1vovar.<\/p><p>1 KW sa rovn\u00e1 1 000 wattov. Tak\u017ee ohrieva\u010d s v\u00fdkonom 1 KW spotrebuje 1 000 wattov skuto\u010dn\u00e9ho v\u00fdkonu.<\/p><p>Tu v\u0161ak nast\u00e1va probl\u00e9m. KW hovor\u00ed o tom, \u010do sa pou\u017e\u00edva - nie o tom, \u010do te\u010die v k\u00e1bloch.<\/p><h3 class=\"wp-block-heading\">\u010co je KVA (kilovoltamp\u00e9r)?<\/h3><p>Spolo\u010dnos\u0165 KVA je teraz in\u00e1. Je to skratka pre kilovoltamp\u00e9ry a meria <em>zdanliv\u00fd v\u00fdkon<\/em>. Ide o celkov\u00fd v\u00fdkon, ktor\u00fd pr\u00fadi cez v\u00e1\u0161 elektrick\u00fd syst\u00e9m - kombin\u00e1ciu re\u00e1lneho v\u00fdkonu (KW) a jalov\u00e9ho v\u00fdkonu.<\/p><p>Jalov\u00fd v\u00fdkon je t\u00e1 z\u00e1kern\u00e1 zlo\u017eka, ktor\u00e1 nevykon\u00e1va \u017eiadnu u\u017eito\u010dn\u00fa pr\u00e1cu, ale je potrebn\u00e1 na udr\u017eanie \u00farovne nap\u00e4tia a magnetick\u00fdch pol\u00ed v motoroch a transform\u00e1toroch.<\/p><p>Predstavte si KVA ako pln\u00fa kapacitu potrubia, ktor\u00fdm te\u010die voda, vr\u00e1tane v\u0161etk\u00fdch z\u00e1krut, odbo\u010diek a slep\u00fdch uli\u010diek - nielen mno\u017estvo, ktor\u00e9 skon\u010d\u00ed vo va\u0161om poh\u00e1ri.<\/p><p>Transform\u00e1tory, gener\u00e1tory a mnoh\u00e9 typy elektrick\u00fdch zariaden\u00ed sa ud\u00e1vaj\u00fa v KVA, preto\u017ee musia zvl\u00e1dnu\u0165 v\u0161etok pr\u00fadiaci v\u00fdkon, nielen \u010das\u0165, ktor\u00e1 sa skuto\u010dne pou\u017e\u00edva.<\/p><p>Napr\u00edklad transform\u00e1tor s menovit\u00fdm v\u00fdkonom 10 KVA m\u00f4\u017ee spracova\u0165 a\u017e 10 kilovoltamp\u00e9rov zdanliv\u00e9ho v\u00fdkonu bez prehriatia.<\/p><h3 class=\"wp-block-heading\">\u00daloha \u00fa\u010dinn\u00edka v KVA vs. KW<\/h3><p>Tu je k\u013e\u00fa\u010dov\u00e1 inform\u00e1cia: \u00fa\u010dinn\u00edk (PF) je pomer KW ku KVA.<\/p><p>PF = KW \u00f7 KVA<\/p><p>Tento pomer hovor\u00ed o tom, ako \u00fa\u010dinne v\u00e1\u0161 elektrick\u00fd syst\u00e9m premie\u0148a zdanliv\u00fd v\u00fdkon na skuto\u010dn\u00fd v\u00fdkon.<\/p><ul class=\"wp-block-list\"><li>\u00da\u010dinn\u00edk 1 (alebo 100%) znamen\u00e1, \u017ee v\u0161etok zdanliv\u00fd v\u00fdkon je premenen\u00fd na skuto\u010dn\u00fd v\u00fdkon - dokonal\u00e1 \u00fa\u010dinnos\u0165.<\/li>\n\n<li>Hodnota PF men\u0161ia ako 1 znamen\u00e1, \u017ee \u010das\u0165 v\u00fdkonu je jalov\u00e1, \u010do sp\u00f4sobuje neefekt\u00edvnos\u0165.<\/li><\/ul><p>Jalov\u00fd v\u00fdkon zni\u017euje \u00fa\u010dinn\u00edk. A slab\u00fd \u00fa\u010dinn\u00edk? Znamen\u00e1 to, \u017ee plat\u00edte za elektrinu, ktor\u00e1 nevykon\u00e1va skuto\u010dn\u00fa pr\u00e1cu - tich\u00fd zabijak \u00fa\u010dinnosti.<\/p><p>\u00da\u010dinn\u00edk nie je len pojem - je to praktick\u00fd ukazovate\u013e s re\u00e1lnym ekonomick\u00fdm a prev\u00e1dzkov\u00fdm vplyvom. Normy IEEE a IEC obsahuj\u00fa pr\u00edsne usmernenia, ale mnoh\u00e9 zariadenia ich st\u00e1le prehliadaj\u00fa.<\/p><h2 class=\"wp-block-heading\">Ako prev\u00e1dza\u0165 medzi KVA a KW<\/h2><h3 class=\"wp-block-heading\">Konverzn\u00fd vzorec a jeho v\u00fdznam<\/h3><p>Najjednoduch\u0161\u00ed vzorec je:<\/p><p><strong>KW = KVA \u00d7 \u00fa\u010dinn\u00edk (PF)<\/strong><\/p><p>Ak m\u00e1te gener\u00e1tor s v\u00fdkonom 100 KVA a \u00fa\u010dinn\u00edkom 0,8, skuto\u010dn\u00fd v\u00fdkon, ktor\u00fd dod\u00e1va, je:<\/p><p>100 \u00d7 0,8 = 80 KW<\/p><p>V\u0161imnite si, ak\u00fd k\u013e\u00fa\u010dov\u00fd v\u00fdznam tu m\u00e1 PF. Nespr\u00e1vny odhad PF znamen\u00e1 bu\u010f poddimenzovanie, alebo predimenzovanie zariadenia - obe chyby s\u00fa drah\u00e9.<\/p><p>\u00da\u010dinn\u00edk sa zvy\u010dajne vyjadruje v desatinn\u00fdch \u010d\u00edslach (napr. 0,85, 0,95), nie v percent\u00e1ch.<\/p><h3 class=\"wp-block-heading\">Pr\u00edklady konverzie v re\u00e1lnom svete<\/h3><ol class=\"wp-block-list\"><li><strong>Scen\u00e1r gener\u00e1tora:<\/strong> Gener\u00e1tor s v\u00fdkonom 100 KVA pracuj\u00faci pri PF 0,8 dod\u00e1va v\u00fdkon 80 KW. Ak ignorujete PF a dimenzujete gener\u00e1tor na 100 KW, riskujete pre\u0165a\u017eenie a poruchu.<\/li>\n\n<li><strong>Za\u0165a\u017eenie priemyseln\u00e9ho motora:<\/strong> Motor s menovit\u00fdm v\u00fdkonom 50 KW a PF 0,9 v skuto\u010dnosti vy\u017eaduje pribli\u017ene 55,6 KVA zdanliv\u00e9ho v\u00fdkonu. Podcenenie tohto v\u00fdkonu znamen\u00e1 prehriatie a skr\u00e1tenie \u017eivotnosti.<\/li><\/ol><p>V jednom projekte, ktor\u00fd som viedol, sme mali n\u00e1kladn\u00fa lekciu, ke\u010f sa \u00fadajne \"vhodn\u00fd\" gener\u00e1tor neust\u00e1le vyp\u00ednal. Vinn\u00edk? Ignorovanie n\u00edzkeho PF sp\u00f4soben\u00e9ho induk\u010dnou z\u00e1\u0165a\u017eou. Len t\u00e1to chyba st\u00e1la desa\u0165tis\u00edce za prestoje.<\/p><h3 class=\"wp-block-heading\">Pre\u010do je d\u00f4le\u017eit\u00e9 presn\u00e9 meranie PF<\/h3><p>\u00da\u010dinn\u00edk priamo ovplyv\u0148uje faktur\u00e1ciu energie, dimenzovanie zariaden\u00ed a celkov\u00fa \u00fa\u010dinnos\u0165 syst\u00e9mu.<\/p><p>Energetick\u00e9 spolo\u010dnosti \u010dasto penalizuj\u00fa z\u00e1kazn\u00edkov s n\u00edzkym \u00fa\u010dinn\u00edkom dodato\u010dn\u00fdmi poplatkami. Presn\u00e9 meranie PF nie je volite\u013en\u00e9, ale nevyhnutn\u00e9.<\/p><p>Modern\u00e9 n\u00e1stroje na monitorovanie spotreby, ako s\u00fa inteligentn\u00e9 mera\u010de a analyz\u00e1tory spotreby, pon\u00fakaj\u00fa preh\u013ead o PF v re\u00e1lnom \u010dase. Niektor\u00e9 strieda\u010de a syst\u00e9my riadenia energie dokonca dynamicky upravuj\u00fa PF.<\/p><p>Ignorovanie PF je ako lietanie naslepo - mysl\u00edte si, \u017ee ste efekt\u00edvni, k\u00fdm v\u00e1m nepr\u00edde \u00fa\u010det.<\/p><h2 class=\"wp-block-heading\">Praktick\u00e9 d\u00f4sledky pre energetick\u00e9 syst\u00e9my a zariadenia<\/h2><h3 class=\"wp-block-heading\">Dimenzovanie gener\u00e1torov a transform\u00e1torov<\/h3><p>Gener\u00e1tory a transform\u00e1tory s\u00fa dimenzovan\u00e9 v KVA, preto\u017ee musia zvl\u00e1dnu\u0165 pln\u00e9 za\u0165a\u017eenie vr\u00e1tane jalov\u00e9ho v\u00fdkonu.<\/p><p>Ignorovanie \u00fa\u010dinn\u00edka m\u00f4\u017ee sp\u00f4sobi\u0165 poddimenzovanie zariadenia, \u010do vedie k prehriatiu, poruche a neo\u010dak\u00e1van\u00fdm prestojom.<\/p><p>Spom\u00ednam si na v\u00fdrobn\u00e9ho klienta, kde gener\u00e1tor $250K katastrof\u00e1lne zlyhal u\u017e po 18 mesiacoch - v\u0161etko preto, \u017ee kon\u0161truk\u010dn\u00fd t\u00edm nezoh\u013eadnil 0,7 PF ich z\u00e1\u0165a\u017ee. Ponau\u010denie? V\u017edy navrhujte na zdanliv\u00fd v\u00fdkon, nielen na skuto\u010dn\u00fd v\u00fdkon.<\/p><h3 class=\"wp-block-heading\">Bat\u00e9riov\u00e9 syst\u00e9my skladovania energie a meni\u010de<\/h3><p><strong><a href=\"https:\/\/www.kmdpower.com\/sk\/commercial-energy-storage-systems\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bat\u00e9riov\u00e9 syst\u00e9my skladovania energie<\/a><\/strong> a strieda\u010de sa tie\u017e vo ve\u013ekej miere spoliehaj\u00fa na rozdiel medzi KVA a KW.<\/p><p>Strieda\u010de musia by\u0165 dimenzovan\u00e9 tak, aby zvl\u00e1dli \u0161pi\u010dkov\u00e9 zdanliv\u00e9 v\u00fdkonov\u00e9 za\u0165a\u017eenie, nielen v\u00fdkon KW.<\/p><p>Inteligentn\u00e9 strieda\u010de s\u00fa teraz vybaven\u00e9 dynamickou korekciou PF, ktor\u00e1 pom\u00e1ha vyrovn\u00e1va\u0165 jalov\u00e9 za\u0165a\u017eenie a zlep\u0161uje celkov\u00fa stabilitu siete.<\/p><p>Korekcia \u00fa\u010dinn\u00edka u\u017e nie je len priemyseln\u00fdm luxusom - st\u00e1va sa \u0161tandardnou praxou v <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/commercial-energy-storage-systems\/\" target=\"_blank\" rel=\"noreferrer noopener\">komer\u010dn\u00e9 syst\u00e9my skladovania energie<\/a><\/strong> a <strong><a href=\"https:\/\/www.kmdpower.com\/sk\/power-wall\/\" target=\"_blank\" rel=\"noreferrer noopener\">reziden\u010dn\u00e9 bat\u00e9riov\u00e9 syst\u00e9my<\/a><\/strong>.<\/p><h3 class=\"wp-block-heading\">Riadenie priemyseln\u00e9ho a komer\u010dn\u00e9ho za\u0165a\u017eenia<\/h3><p>Jalov\u00e9 z\u00e1\u0165a\u017ee, ako s\u00fa motory a predradn\u00edky osvetlenia, zni\u017euj\u00fa hodnotu PF.Korekcia \u00fa\u010dinn\u00edka m\u00f4\u017ee zn\u00ed\u017ei\u0165 pokuty, zn\u00ed\u017ei\u0165 straty a pred\u013a\u017ei\u0165 \u017eivotnos\u0165 zariaden\u00ed.<\/p><p>Jeden ve\u013ek\u00fd v\u00fdrobn\u00fd z\u00e1vod, s ktor\u00fdm som konzultoval, zn\u00ed\u017eil svoje \u00fa\u010dty za energiu o 12% po in\u0161tal\u00e1cii kondenz\u00e1torov na korekciu PF - n\u00e1vratnos\u0165 bola menej ako rok.<\/p><h2 class=\"wp-block-heading\">Be\u017en\u00e9 myln\u00e9 predstavy a kritick\u00e9 postrehy<\/h2><h3 class=\"wp-block-heading\">\"KVA je ako KW, v\u0161ak?\" - Vyvr\u00e1tenie m\u00fdtu<\/h3><p>Pr\u00edli\u0161 ve\u013ea \u013eud\u00ed predpoklad\u00e1, \u017ee KVA a KW s\u00fa zamenite\u013en\u00e9. Tento predpoklad vedie k neefekt\u00edvnosti, zbyto\u010dn\u00fdm n\u00e1kladom a za\u0165a\u017eeniu zariaden\u00ed.Odvetvie to nechce prizna\u0165, ale je to n\u00e1kladn\u00e1 chyba, ktor\u00e1 sa opakuje ka\u017ed\u00fd de\u0148.<\/p><h3 class=\"wp-block-heading\">Prehliadan\u00e9 ved\u013eaj\u0161ie \u00fa\u010dinky n\u00edzkeho \u00fa\u010dinn\u00edka<\/h3><p>Zl\u00fd PF sp\u00f4sobuje zv\u00fd\u0161en\u00e9 straty, prehrievanie a skr\u00e1tenie \u017eivotnosti transform\u00e1torov a motorov.Energetick\u00e9 podniky tie\u017e penalizuj\u00fa zl\u00fd PF, \u010do zvy\u0161uje prev\u00e1dzkov\u00e9 n\u00e1klady.<\/p><p>Nejde len o \u00fa\u010dinnos\u0165 - ide o dlh\u00fa \u017eivotnos\u0165 zariadenia a predch\u00e1dzanie n\u00e1kladom.<\/p><h3 class=\"wp-block-heading\">Moja odv\u00e1\u017ena predpove\u010f: \u00da\u010dinn\u00edk a KVA bud\u00fa v \u00e9re obnovite\u013en\u00fdch zdrojov energie e\u0161te d\u00f4le\u017eitej\u0161ie<\/h3><p>S n\u00e1rastom distribuovan\u00fdch zdrojov energie, mikrosiet\u00ed a obojsmern\u00fdch tokov energie bude riadenie KVA a PF zlo\u017eitej\u0161ie a d\u00f4le\u017eitej\u0161ie.<\/p><p>N\u00e1vrhy inteligentn\u00fdch siet\u00ed a vyv\u00edjaj\u00face sa normy musia tieto v\u00fdzvy rie\u0161i\u0165.M\u00f4j pocit mi hovor\u00ed, \u017ee t\u00ed, ktor\u00ed dnes ignoruj\u00fa PF, bud\u00fa v zajtraj\u0161om energetickom prostred\u00ed zasko\u010den\u00ed.<\/p><h2 class=\"wp-block-heading\">Z\u00e1ver<\/h2><p>Pochopenie rozdielu medzi KVA a KW je viac ne\u017e len technick\u00fd \u017earg\u00f3n - je to k\u013e\u00fa\u010d k tomu, aby ste sa vyhli n\u00e1kladn\u00fdm chyb\u00e1m pri n\u00e1vrhu energetick\u00e9ho syst\u00e9mu. Na vlastnej ko\u017ei som sa presved\u010dil, \u017ee ignorovanie \u00fa\u010dinn\u00edka vedie k plytvaniu energiou a pred\u010dasn\u00e9mu zlyhaniu zariaden\u00ed. S rozvojom energetick\u00fdch syst\u00e9mov v\u010faka obnovite\u013en\u00fdm zdrojom energie a inteligentn\u00fdm sie\u0165am sa tieto znalosti st\u00e1vaj\u00fa k\u013e\u00fa\u010dov\u00fdmi. Nepodce\u0148ujte ho. Starostlivo merajte, spochyb\u0148ujte predpoklady a optimalizujte svoje nastavenie. Ovl\u00e1danie pomerov KVA a KW nie je len presnos\u0165 - je to zmena \u00fa\u010dinnosti a odolnosti.<\/p><h1 class=\"wp-block-heading\">\u010cASTO KLADEN\u00c9 OT\u00c1ZKY<\/h1><h3 class=\"wp-block-heading\"><strong>Ak\u00fd je rozdiel medzi KVA a KW?<\/strong><\/h3><p>KW je skuto\u010dn\u00fd v\u00fdkon, ktor\u00fd vykon\u00e1va pr\u00e1cu; KVA je celkov\u00fd v\u00fdkon vr\u00e1tane nepracovn\u00e9ho jalov\u00e9ho v\u00fdkonu.<\/p><h3 class=\"wp-block-heading\"><strong>Ako ovplyv\u0148uje \u00fa\u010dinn\u00edk m\u00f4j \u00fa\u010det za elektrinu?<\/strong><\/h3><p>N\u00edzky \u00fa\u010dinn\u00edk znamen\u00e1, \u017ee plat\u00edte za viac elektrickej energie, ako skuto\u010dne spotrebujete, a navy\u0161e m\u00f4\u017eete zaplati\u0165 pokuty.<\/p><h3 class=\"wp-block-heading\"><strong>M\u00f4\u017ee by\u0165 KVA v\u00e4\u010d\u0161\u00ed ako KW? Pre\u010do?<\/strong><\/h3><p>\u00c1no, preto\u017ee KVA zah\u0155\u0148a aj jalov\u00fd v\u00fdkon, ktor\u00fd nevykon\u00e1va u\u017eito\u010dn\u00fa pr\u00e1cu, ale je potrebn\u00fd pre stabilitu s\u00fastavy.<\/p><h3 class=\"wp-block-heading\"><strong>Ako m\u00f4\u017eem zlep\u0161i\u0165 \u00fa\u010dinn\u00edk vo svojom zariaden\u00ed?<\/strong><\/h3><p>Pou\u017e\u00edvanie kondenz\u00e1torov\u00fdch bat\u00e9ri\u00ed, synchr\u00f3nnych kondenz\u00e1torov alebo inteligentn\u00fdch strieda\u010dov na kompenz\u00e1ciu jalov\u00fdch z\u00e1\u0165a\u017e\u00ed.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00davod: Po cel\u00e9 desa\u0165ro\u010dia sp\u00f4sobovalo zamie\u0148anie pojmov KVA a KW n\u00e1kladn\u00e9 chyby pri projektovan\u00ed energetick\u00fdch syst\u00e9mov - pochopenie tohto rozdielu je v\u0161ak jednoduch\u0161ie, ako si mysl\u00edte. Ke\u010f\u017ee som str\u00e1vil viac ako 25 rokov z\u00e1pasen\u00edm s energetick\u00fdmi syst\u00e9mami, od robustn\u00fdch priemyseln\u00fdch bat\u00e9riov\u00fdch \u00falo\u017e\u00edsk a\u017e po \u0161pi\u010dkov\u00e9 integr\u00e1cie obnovite\u013en\u00fdch zdrojov energie, bol som priamym svedkom toho, ako toto nedorozumenie m\u00f4\u017ee vybuchn\u00fa\u0165...<\/p>","protected":false},"author":1,"featured_media":4175,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-4440","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/4440","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/comments?post=4440"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/4440\/revisions"}],"predecessor-version":[{"id":4441,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/posts\/4440\/revisions\/4441"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media\/4175"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/media?parent=4440"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/categories?post=4440"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/sk\/wp-json\/wp\/v2\/tags?post=4440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}