{"id":5305,"date":"2026-11-18T06:59:21","date_gmt":"2026-11-18T06:59:21","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5305"},"modified":"2026-11-18T06:59:24","modified_gmt":"2026-11-18T06:59:24","slug":"will-a-solar-poe-switch-disconnect-a-12v-sodium-ion-battery-before-its-usable-energy-is-exhausted","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/ro\/news\/will-a-solar-poe-switch-disconnect-a-12v-sodium-ion-battery-before-its-usable-energy-is-exhausted\/","title":{"rendered":"Un comutator solar PoE va deconecta o baterie cu ioni de sodiu de 12 V \u00eenainte ca energia utilizabil\u0103 a acesteia s\u0103 se epuizeze?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">O sta\u021bie de supraveghere video la distan\u021b\u0103 \u00eenceteaz\u0103 s\u0103 mai \u00eenregistreze \u00eenainte de r\u0103s\u0103rit. Switch-ul solar PoE semnaleaz\u0103 oprirea din cauza bateriei desc\u0103rcate, dar <strong><a href=\"https:\/\/www.kmdpower.com\/ro\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">baterie sodiu-ion<\/a><\/strong> Bateria nu a declan\u0219at protec\u021bia BMS \u00eempotriva subtensiunii. Este bateria subdimensionat\u0103 sau comutatorul a deconectat sarcina \u00eenainte de timp? <strong>Un switch PoE solar poate deconecta camerele \u00eenainte ca bateria s\u0103 ating\u0103 limita de desc\u0103rcare, dar o m\u0103sur\u0103toare a tensiunii nu poate cuantifica energia util\u0103 r\u0103mas\u0103.<\/strong> Compara\u021bi tensiunea LVD, tensiunea de reconectare la sarcin\u0103 (LVR), limitele aprobate ale pachetului \u0219i tensiunea sub sarcina real\u0103 a camerei.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-12v-100ah-sodium-ion-battery-main-image-002.jpg\" alt=\"\" class=\"wp-image-1181\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/ro\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100Ah Baterie cu ioni de sodiu<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Se poate ca un switch solar PoE s\u0103 se opreasc\u0103 \u00eenaintea sistemului BMS al bateriei?<\/h2><p class=\"wp-block-paragraph\">Da. Multe controlere solare PoE gestioneaz\u0103 sarcina camerei separat de protec\u021bia intern\u0103 a bateriei. Controlerul poate opri ie\u0219irea de sarcin\u0103 PoE sau DC atunci c\u00e2nd tensiunea m\u0103surat\u0103 la intrarea bateriei atinge un prag programat. Este posibil ca sistemul de gestionare a bateriei (BMS) s\u0103 permit\u0103 \u00een continuare desc\u0103rcarea \u00een acel moment. Aceasta nu reprezint\u0103 neap\u0103rat o defec\u021biune a controlerului: func\u021bia LVD este conceput\u0103 pentru a men\u021bine rezerva bateriei, a evita desc\u0103rc\u0103rile d\u0103un\u0103toare \u0219i a oferi sistemului un punct de recuperare definit.<\/p><p class=\"wp-block-paragraph\">Arhitectura sistemului este important\u0103. O unitate solar\u0103 PoE integrat\u0103 \u00ee\u0219i poate dezactiva ie\u0219irea PoE. Un MPPT separat poate, \u00een schimb, s\u0103 comande un releu extern, \u00een timp ce un injector conectat la baterie poate ignora semnalul de control al sarcinii. Verifica\u021bi, de asemenea, modurile de func\u021bionare temporizate \u0219i cele dependente de lumina zilei. <strong>Identifica\u021bi ce anume \u00eentrerupe alimentarea camerei \u00eenainte de a da vina pe baterie.<\/strong><\/p><p class=\"wp-block-paragraph\">The <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-user-manual\" target=\"_blank\" rel=\"noreferrer noopener\">Manualul de utilizare Linovision POE-SW804G-SOLAR<\/a> prezint\u0103 o func\u021bie de protec\u021bie \u00eempotriva desc\u0103rc\u0103rii excesive care opre\u0219te ie\u0219irea de sarcin\u0103. Profilul s\u0103u de referin\u021b\u0103 pentru bateria LiFePO4 de 12 V indic\u0103 11,2 V pentru desc\u0103rcarea excesiv\u0103 \u0219i 12,3 V pentru recuperare. Acestea sunt <strong>set\u0103ri de referin\u021b\u0103 specifice echipamentului pentru profilul respectiv al bateriei, nu recomand\u0103ri pentru bateriile cu ioni de sodiu<\/strong>. Configura\u021bia exact\u0103 a firmware-ului \u0219i comportamentul \u00een func\u021bionare trebuie verificate \u00een cadrul unui proiect real.<\/p><h2 class=\"wp-block-heading\">Ce ne indic\u0103 set\u0103rile publicate pentru LVD \u0219i reconectare?<\/h2><p class=\"wp-block-paragraph\">Diferitele controlere \u2014 precum \u0219i diferitele moduri ale unui singur controler \u2014 utilizeaz\u0103 praguri substan\u021bial diferite. Urm\u0103toarele sunt exemple verificabile de <strong>set\u0103rile echipamentului publicate<\/strong>, nu sunt set\u0103ri recomandate pentru o baterie cu ioni de sodiu.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Modul \u201eProduc\u0103tor\u201d \u0219i modul \u201eDocumentat\u201d<\/th><th>Deconectare sarcin\u0103 12 V<\/th><th>Reconectarea sarcinii de 12 V<\/th><th>O limitare important\u0103<\/th><\/tr><\/thead><tbody><tr><td>Linovision POE-SW804G-SOLAR, profil de referin\u021b\u0103 4S LiFePO4<\/td><td>11,2 V<\/td><td>12.3V<\/td><td>Confirma\u021bi configura\u021bia actual\u0103 \u0219i implementarea sistemului de control al sarcinii<\/td><\/tr><tr><td>Victron SmartSolar, algoritmul de sarcin\u0103 conven\u021bional 2<\/td><td>11.8V<\/td><td>14,0 V<\/td><td>Comand\u0103 o func\u021bie de ie\u0219ire \u00een func\u021bie de sarcin\u0103 sau un dispozitiv extern de deconectare, \u00een func\u021bie de model<\/td><\/tr><tr><td>Morningstar GenStar MPPT, LiFePO4 presetat la 5<\/td><td>12.5V<\/td><td>13,15 V<\/td><td>Avertisment LVD de un minut; <strong>0 mV\/A<\/strong> compensare curent\u0103; nu este o setare prestabilit\u0103 pentru ioni de sodiu<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Surse: <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-user-manual\" target=\"_blank\" rel=\"noreferrer noopener\">Manualul controlerului Linovision<\/a>, <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/Manual_SmartSolar_MPPT_150-60_up_to_250-70\/en\/configuration-and-settings.html\" target=\"_blank\" rel=\"noreferrer noopener\">Set\u0103rile de sarcin\u0103 \u0219i putere de ie\u0219ire ale sistemului Victron SmartSolar<\/a>, \u0219i <a href=\"https:\/\/knowledgebase.morningstarcorp.com\/docs\/53-load-control-information\" target=\"_blank\" rel=\"noreferrer noopener\">Documenta\u021bia privind controlul sarcinii pentru Morningstar GenStar<\/a>. Compara\u021bi numai modelele \u0219i modurile specificate; aceste numere nu sunt interschimbabile.<\/p><p class=\"wp-block-paragraph\"><strong>Figura 1 \u2014 Pragurile LVD \u0219i LVR ale controlerului de 12 V, conform specifica\u021biilor publicate<\/strong><\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"468\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-1024x468.png\" alt=\"\" class=\"wp-image-5306\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-1024x468.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-300x137.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-18x8.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-767x351.png 767w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart-599x274.png 599w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/V10-02_Published_Controller_LVD_LVR_Chart.png 1504w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Au fost publicate set\u0103rile de deconectare \u0219i reconectare la tensiune sc\u0103zut\u0103 pentru anumite moduri de func\u021bionare ale controlerelor Linovision, Victron \u0219i Morningstar. Acestea sunt set\u0103ri de referin\u021b\u0103 ale produc\u0103torului, nu valori recomandate pentru LVD\/LVR \u00een cazul <strong><a href=\"https:\/\/www.kmdpower.com\/ro\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bateria cu ioni de sodiu Kamada Power<\/a><\/strong>.<\/p><p class=\"wp-block-paragraph\">Tensiunea de reconectare poate fi cu mult mai mare dec\u00e2t tensiunea de deconectare. Aceast\u0103 histerezis limiteaz\u0103 num\u0103rul de cicluri, dar poate l\u0103sa instala\u021bia deconectat\u0103 dup\u0103 r\u0103s\u0103ritul soarelui. O revenire a tensiunii bateriei \u00een stare de repaus nu asigur\u0103 energia necesar\u0103 pentru o repornire sus\u021binut\u0103.<\/p><h2 class=\"wp-block-heading\">Bateria cu ioni de sodiu de 12 V mai are energie utilizabil\u0103 la nivelul LVD?<\/h2><p class=\"wp-block-paragraph\">Poate, dar <strong>nu doar pentru c\u0103 sistemul BMS nu s-a declan\u0219at<\/strong>. Fi\u0219a tehnic\u0103 a bateriei KMDPOWER 12 V 100 Ah furnizat\u0103 specific\u0103 <strong>12 V nominal, 100 Ah, energie nominal\u0103 de 1.200 Wh, tensiune maxim\u0103 de \u00eenc\u0103rcare de 15,6 V \u0219i tensiune de \u00eentrerupere a desc\u0103rc\u0103rii de 8 V<\/strong>. Valoarea de 8 V reprezint\u0103 un prag de protec\u021bie, <strong>nu este un LVD PoE solar recomandat<\/strong> sau dovada existen\u021bei unei cantit\u0103\u021bi de Wh utilizabil\u0103 sub pragul stabilit de controler. Aceasta <a href=\"https:\/\/www.kmdpower.com\/ro\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100ah Baterie cu ioni de sodiu<\/a> utilizeaz\u0103 o etichet\u0103 de model de 12,8 V; nu combina\u021bi reviziile f\u0103r\u0103 confirmare. Ob\u021bine\u021bi datele privind \u00eenc\u0103rcarea \u0219i desc\u0103rcarea, set\u0103rile BMS \u0219i limitele de temperatur\u0103. <strong>Tensiunea electric\u0103, luat\u0103 separat, nu poate cuantifica energia r\u0103mas\u0103.<\/strong><\/p><p class=\"wp-block-paragraph\">Tensiunea la bornele bateriei este influen\u021bat\u0103 de starea de \u00eenc\u0103rcare, curentul de sarcin\u0103, temperatura \u0219i rezisten\u021ba intern\u0103. Controlerul PoE \u00eenregistreaz\u0103, de asemenea, pierderile din cablaj \u0219i din conectori. \u00cen condi\u021bii de sarcin\u0103 ridicat\u0103, tensiunea m\u0103surat\u0103 de controler poate sc\u0103dea sub pragul LVD, \u00een timp ce tensiunea la bornele pachetului de baterii r\u0103m\u00e2ne mai mare.<\/p><p class=\"wp-block-paragraph\">De exemplu, <strong>5 A \u00d7 0,04 \u03a9 = 0,20 V<\/strong> sc\u0103dere. Controlerul ar putea indica 11,2 V, \u00een timp ce bateria ar indica 11,4 V. Acesta este un scenariu ipotetic, nu un test KMDPOWER. Unitatea Linovision de 12 V specific\u0103 o <strong>Buget PoE de 60 W \u0219i curent de ie\u0219ire maxim de 5 A<\/strong>; verifica\u021bi ambele limite \u0219i puterea maxim\u0103 a camerelor, nu doar puterea medie \u00een wa\u021bi. Consumul real de 5 A trebuie, de asemenea, s\u0103 respecte toate valorile nominale ale dispozitivelor \u0219i ale ie\u0219irilor. <a href=\"https:\/\/support.linovision.com\/portal\/en\/kb\/articles\/poe-sw804g-solar-4-ports-mppt-solar-poe-switch\" target=\"_blank\" rel=\"noreferrer noopener\">Specifica\u021bii Linovision<\/a>.<\/p><p class=\"wp-block-paragraph\">Pentru a cuantifica energia re\u021binut\u0103 de LVD, compara\u021bi testele de desc\u0103rcare aprobate, efectuate pornind de la aceea\u0219i stare ini\u021bial\u0103 a bateriei, la sarcin\u0103 \u0219i temperatur\u0103 identice, cu \u00eenc\u0103rcarea solar\u0103 dezactivat\u0103 sau m\u0103surat\u0103 separat:<\/p><p class=\"wp-block-paragraph\"><strong>Energia furnizat\u0103 de baterie \u00eenainte de declan\u0219area LVD (Wh) = \u222b tensiunea la bornele bateriei \u00d7 curentul net de desc\u0103rcare al bateriei dt, p\u00e2n\u0103 la primul eveniment LVD.<\/strong><\/p><p class=\"wp-block-paragraph\">Un test de desc\u0103rcare aprobat, efectuat separat, poate determina cantitatea suplimentar\u0103 de energie \u00een limitele permise ale pachetului. Compara\u021bi valoarea Wh de la baterie pe aceea\u0219i baz\u0103 \u0219i m\u0103sura\u021bi separat valoarea Wh de la partea de sarcin\u0103 a PoE pentru a identifica pierderile de conversie \u0219i de cablare. Diferen\u021ba este <em>energie indisponibil\u0103 \u00een cadrul acelei configura\u021bii testate a controlerului<\/em>, nu un procent fix de 1.200 Wh. Nu ocoli\u021bi niciodat\u0103 sistemul BMS.<\/p><h3 class=\"wp-block-heading\">De ce valoarea limit\u0103 a BMS nu este un obiectiv util \u00een practica de zi cu zi pentru LVD<\/h3><p class=\"wp-block-paragraph\">O declan\u0219are din cauza subtensiunii \u00een sistemul BMS reprezint\u0103 o m\u0103sur\u0103 de protec\u021bie de ultim\u0103 instan\u021b\u0103, nu un criteriu normal de oprire \u00een cadrul supravegherii. Pachetul de baterii alimentat <strong>Limita de desc\u0103rcare de 8 V<\/strong> nu reprezint\u0103 o instruc\u021biune de reducere a tensiunii LVD a controlerului la 8 V. Trebuie s\u0103 se \u021bin\u0103 cont de marjele verificate pentru c\u0103derile de tensiune, tensiunea minim\u0103 de intrare a convertorului, temperatur\u0103 \u0219i rezerv\u0103; \u00een caz contrar, pot ap\u0103rea \u00eentreruperi bru\u0219te \u0219i reset\u0103ri repetate. Exist\u0103 <strong>nu exist\u0103 o valoare universal\u0103 a pragului de tensiune sc\u0103zut\u0103 (LVD) pentru bateriile cu ioni de sodiu de 12 V<\/strong>.<\/p><h2 class=\"wp-block-heading\">De ce ar putea camerele s\u0103 r\u0103m\u00e2n\u0103 deconectate dup\u0103 reluarea \u00eenc\u0103rc\u0103rii solare?<\/h2><p class=\"wp-block-paragraph\">Controlerul se deconecteaz\u0103 la activarea LVD \u0219i poate a\u0219tepta activarea LVR, o \u00eent\u00e2rziere sau o alt\u0103 condi\u021bie \u00eenainte de a se reconecta. Controlerul <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/Manual_SmartSolar_MPPT_150-60_up_to_250-70\/en\/configuration-and-settings.html\" target=\"_blank\" rel=\"noreferrer noopener\">Manualul Victron SmartSolar<\/a> stabile\u0219te o \u00eent\u00e2rziere de r\u0103spuns de dou\u0103 minute pentru anumi\u021bi algoritmi de \u00eenc\u0103rcare. <a href=\"https:\/\/knowledgebase.morningstarcorp.com\/docs\/53-load-control-information\" target=\"_blank\" rel=\"noreferrer noopener\">Morningstar<\/a> prezint\u0103 avertismentele \u0219i compensa\u021biile actuale, dar <strong>Presetarea 5 pentru LiFePO4 are o compensare de 0 mV\/A<\/strong>. O alt\u0103 explica\u021bie posibil\u0103 pentru lipsa imaginii video este starea de OPRIT programat\u0103 sau controlat\u0103 de lumin\u0103.<\/p><p class=\"wp-block-paragraph\">Lan\u021bul de evenimente relevant este:<\/p><p class=\"wp-block-paragraph\"><strong>Bateria alimenteaz\u0103 camerele \u2192 controlerul atinge pragul LVD \u2192 sarcina camerelor se deconecteaz\u0103 \u2192 \u00eenc\u0103rcarea solar\u0103 cre\u0219te tensiunea bateriei \u2192 controlerul atinge pragul LVR \u2192 camerele \u00eencearc\u0103 s\u0103 reporneasc\u0103.<\/strong><\/p><p class=\"wp-block-paragraph\">Dac\u0103 tensiunea scade din nou la pornirea switch-ului PoE \u0219i a camerelor, sarcina se poate deconecta \u00eenc\u0103 o dat\u0103. Aceast\u0103 situa\u021bie necesit\u0103 un test de repornire sub sarcin\u0103 \u2014 nu o presupunere c\u0103 bateria este desc\u0103rcat\u0103. Limita\u021bi aceast\u0103 investiga\u021bie la <strong>Coordonarea LVD \u0219i a reconect\u0103rii<\/strong>; faptul c\u0103 un MPPT nu porne\u0219te dup\u0103 izolarea BMS reprezint\u0103 o alt\u0103 problem\u0103 de diagnosticare.<\/p><h2 class=\"wp-block-heading\">Cum ar trebui un produc\u0103tor de echipamente originale (OEM) s\u0103 testeze LVD f\u0103r\u0103 a dezactiva protec\u021bia bateriei?<\/h2><p class=\"wp-block-paragraph\">Utiliza\u021bi switch-ul PoE, firmware-ul, versiunea pachetului, \u00eenc\u0103rc\u0103torul, siguran\u021bele, cablajul \u0219i sarcina camerei respective. Mai \u00eent\u00e2i verifica\u021bi <strong>compatibilitatea de \u00eenc\u0103rcare<\/strong>: fi\u0219a tehnic\u0103 KMDPOWER indic\u0103 o <strong>Tensiune maxim\u0103 de \u00eenc\u0103rcare de 15,6 V<\/strong>, \u00een timp ce modelul de referin\u021b\u0103 al Linovision <em>LiFePO4<\/em> profilul specific\u0103 <strong>\u00cenc\u0103rcare la 14,4 V, protec\u021bie \u00eempotriva supratensiunii la 15,0 V \u0219i protec\u021bie \u00eempotriva \u00eenc\u0103rc\u0103rii la temperaturi sc\u0103zute de 0 \u00b0C<\/strong>. Limita sa de \u00eenc\u0103rcare este <strong>10A<\/strong>. Acestea sunt <strong>set\u0103ri cu ioni de sodiu neaprobate<\/strong>; \u00eenainte de testare, confirma\u021bi limitele programabile, profilul de \u00eenc\u0103rcare aprobat pentru baterie \u0219i comportamentul la temperatur\u0103 cu ambii produc\u0103tori. O surs\u0103 de alimentare de laborator nu poate demonstra, pe cont propriu, autonomia pachetului de baterii.<\/p><p class=\"wp-block-paragraph\"><strong>Pasul 1 \u2014 Identifica\u021bi toate limitele de tensiune.<\/strong> \u00cenregistra\u021bi valorile LVD\/LVR, punctul de detectare, toleran\u021bele, \u00eent\u00e2rzierile \u0219i programul de \u00eenc\u0103rcare. Verifica\u021bi <strong>Limita de \u00eenc\u0103rcare de 15,6 V<\/strong>, regulile de \u00eenc\u0103rcare aprobate bazate pe raportul curent-temperatur\u0103, set\u0103rile BMS ale bateriei \u0219i tensiunea minim\u0103 de intrare a convertorului. Procedura standard CC\/CV de 15,6 V din fi\u0219a tehnic\u0103 este specificat\u0103 pentru <strong>0\u201345 \u00b0C<\/strong>; clarifica\u021bi regulile de taxare \u00een afara acestei benzi \u00eenainte de certificare.<\/p><p class=\"wp-block-paragraph\"><strong>Pasul 2 \u2014 M\u0103sura\u021bi tensiunea \u00een dou\u0103 puncte.<\/strong> \u00cenregistra\u021bi valorile de la bornele bateriei \u0219i de la intrarea controlerului sub sarcina PoE real\u0103, al\u0103turi de <strong>curentul net al bateriei<\/strong>, temperatura, modul de func\u021bionare al controlerului, puterea de ie\u0219ire PoE \u0219i disponibilitatea camerei. Include\u021bi IR, \u00eenc\u0103lzitoarele \u0219i consumul la pornire. Nota\u021bi prima \u00eentrerupere \u0219i dac\u0103 aceasta este cauzat\u0103 de LVD, de un program de sarcin\u0103 sau de o declan\u0219are a bugetului de energie. <a href=\"https:\/\/whitepapers.axis.com\/en-us\/typical-and-maximum-power-consumption-in-axis-cameras\" target=\"_blank\" rel=\"noopener\">Recomand\u0103ri privind consumul de energie al produselor AXIS<\/a>.<\/p><p class=\"wp-block-paragraph\"><strong>Pasul 3 \u2014 Utiliza\u021bi o procedur\u0103 aprobat\u0103 de desc\u0103rcare controlat\u0103.<\/strong> Porni\u021bi de la o stare ini\u021bial\u0103 documentat\u0103 a bateriei. Men\u021bine\u021bi sarcina \u0219i temperatura sub control. Opri\u021bi-v\u0103 la prima limit\u0103 aplicabil\u0103 a sistemului. Nu realiza\u021bi scurtcircuite, nu ocoli\u021bi sistemul, nu for\u021ba\u021bi manual declan\u0219area BMS \u0219i nu continua\u021bi dincolo de limitele aprobate de desc\u0103rcare.<\/p><p class=\"wp-block-paragraph\"><strong>Pasul 4 \u2014 Verific\u0103 ipoteza privind energia r\u0103mas\u0103.<\/strong> \u00cen conformitate cu un plan de testare aprobat, compara\u021bi valoarea Wh de la baterie cu cea de la camer\u0103, la sarcin\u0103, temperatur\u0103 \u0219i condi\u021bii de pornire identice. Lua\u021bi \u00een considerare energia solar\u0103 primit\u0103; o m\u0103surare a tensiunii dup\u0103 deconectare nu constituie un test de capacitate. Opri\u021bi testul \u00eenainte de a se dep\u0103\u0219i limita oric\u0103rui echipament sau a bateriei.<\/p><p class=\"wp-block-paragraph\"><strong>Pasul 5 \u2014 Verifica\u021bi recuperarea.<\/strong> Restabili\u021bi sursa de alimentare aprobat\u0103. \u00cenregistra\u021bi momentul reconect\u0103rii controlerului \u0219i tranzi\u021bia de pornire a camerei. Repeta\u021bi opera\u021biunea la temperatura relevant\u0103 a proiectului \u0219i dup\u0103 ce au fost luate \u00een calcul pierderile realiste din cabluri \u0219i conectori.<\/p><p class=\"wp-block-paragraph\">\u00cenregistrarea ar trebui s\u0103 fac\u0103 distinc\u021bia \u00eentre <strong>controler LVD, reducerea sarcinii programat\u0103\/\u00een func\u021bie de lumina zilei, bugetul de alimentare PoE sau subtensiunea convertorului, protec\u021bia BMS \u0219i energia disponibil\u0103 insuficient\u0103<\/strong>. Acestea necesit\u0103 corec\u021bii diferite.<\/p><h2 class=\"wp-block-heading\">Ar trebui ca produc\u0103torul de echipamente originale (OEM) s\u0103 \u00eenlocuiasc\u0103 switch-ul PoE, set\u0103rile acestuia sau bateria?<\/h2><p class=\"wp-block-paragraph\">Decizia de achizi\u021bie depinde de cauza identificat\u0103 \u2014 nu de o preferin\u021b\u0103 pentru bateriile cu ioni de sodiu, LiFePO\u2084 sau orice alt tip de compozi\u021bie chimic\u0103.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Rezultatul testului<\/th><th>Urm\u0103toarea decizie adecvat\u0103<\/th><\/tr><\/thead><tbody><tr><td>Apare o eroare LVD a controlerului \u00eentr-o faz\u0103 incipient\u0103; profilul aprobat de produc\u0103tor se \u00eencadreaz\u0103 \u00een toate limitele<\/td><td>Preciza\u021bi set\u0103rile \u00een func\u021bie de rezerva m\u0103surat\u0103 \u0219i de marja de repornire<\/td><\/tr><tr><td>LVD\/LVR sau <strong>profil de \u00eenc\u0103rcare<\/strong> este incompatibil cu pachetul exact<\/td><td>Alege\u021bi un controler compatibil sau o arhitectur\u0103 de alimentare protejat\u0103; nu importa\u021bi valorile implicite pentru LiFePO4<\/td><\/tr><tr><td>Se dep\u0103\u0219e\u0219te bugetul de putere PoE sau tensiunea de intrare a convertorului se \u00eentrerupe prima<\/td><td>Corecta\u021bi interfa\u021ba sarcin\u0103\/putere; o capacitate suplimentar\u0103 a bateriei (Ah) nu este prima solu\u021bie<\/td><\/tr><tr><td>Se activeaz\u0103 mai \u00eent\u00e2i protec\u021bia \u00eempotriva desc\u0103rc\u0103rii BMS, altfel pachetul m\u0103surat nu poate asigura rezerva necesar\u0103<\/td><td>Reevalua\u021bi pachetul exact, limitele de curent \u0219i temperatur\u0103, capacitatea util\u0103 \u00een Wh \u0219i necesarul energetic al sistemului<\/td><\/tr><tr><td>Site-ul nu reu\u0219e\u0219te s\u0103 se reconecteze sau este dezactivat conform programului\/modului de economisire a energiei<\/td><td>Verifica\u021bi histerezisul, supratensiunea la pornire, c\u0103derea de tensiune \u0219i modul de control al sarcinii<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Extinderea \u00een paralel aprobat\u0103 de produc\u0103tor poate cre\u0219te puterea \u0219i reduce sarcina pe fiecare pachet, ceea ce ar putea reduce c\u0103derile de tensiune. Aceasta <strong>nu modific\u0103 tensiunea nominal\u0103 a bateriei<\/strong> sau remedia\u021bi o setare LVD sau un profil de \u00eenc\u0103rcare incompatibil. De asemenea, o baterie mai mare nu cre\u0219te curentul de \u00eenc\u0103rcare solar\u0103. Recalcula\u021bi valoarea m\u0103surat\u0103 \u00een Wh \u0219i timpul de re\u00eenc\u0103rcare \u00eenainte de a ad\u0103uga pachete de baterii.<\/p><p class=\"wp-block-paragraph\">Un \u00eenregistrare a deciziilor OEM trebuie s\u0103 con\u021bin\u0103 firmware-ul comutatorului, set\u0103rile de \u00eenc\u0103rcare, LVD\/LVR, versiunea bateriei, Wh m\u0103surat, bugetul de sarcin\u0103 \u0219i rezerva de repornire. Pentru un context mai amplu, consulta\u021bi <a href=\"https:\/\/www.kmdpower.com\/ro\/news\/12v-100ah-sodium-ion-battery-for-security-systems\/\">Aplica\u021bii ale sistemului de securitate Kamada Power de 12 V<\/a>; \u00eentrebarea este urm\u0103toarea: <strong>dac\u0103 controlerul pune energia utilizabil\u0103 a bateriei la dispozi\u021bia camerelor<\/strong>.<\/p><h2 class=\"wp-block-heading\">\u00centreb\u0103ri frecvente<\/h2><h3 class=\"wp-block-heading\">Se poate ca un switch solar PoE s\u0103 se deconecteze \u00een timp ce sistemul BMS permite \u00een continuare desc\u0103rcarea?<\/h3><p class=\"wp-block-paragraph\">Da. Sistemul LVD al controlerului poate elimina sarcina camerei \u00eenainte ca bateria s\u0103 intre \u00een starea de protec\u021bie \u00eempotriva subtensiunii a sistemului BMS. Pentru a stabili dac\u0103 r\u0103m\u00e2n cantit\u0103\u021bi semnificative de Wh, este necesar s\u0103 se efectueze m\u0103sur\u0103tori \u00een condi\u021bii aprobate.<\/p><h3 class=\"wp-block-heading\">Faptul c\u0103 tensiunea bateriei este mai mare dup\u0103 oprire dovede\u0219te c\u0103 bateria nu era desc\u0103rcat\u0103?<\/h3><p class=\"wp-block-paragraph\">Nu. Tensiunea poate s\u0103 revin\u0103 la valoarea ini\u021bial\u0103 atunci c\u00e2nd sarcina este \u00eendep\u0103rtat\u0103. F\u0103r\u0103 curba de desc\u0103rcare, curentul, temperatura \u0219i \u00eenregistrarea evenimentelor controlerului, valoarea afi\u0219at\u0103 nu indic\u0103 energia util\u0103 r\u0103mas\u0103.<\/p><h3 class=\"wp-block-heading\">Pot pur \u0219i simplu s\u0103 reduc tensiunea LVD la tensiunea de \u00eentrerupere a sistemului BMS al bateriei?<\/h3><p class=\"wp-block-paragraph\">Nu. Fi\u0219ele tehnice ale produsului Kamada Power furnizate <strong>Limita de desc\u0103rcare de 8 V nu este o valoare recomandat\u0103 pentru LVD<\/strong>. Respecta\u021bi cu stricte\u021be limitele privind pachetul \u0219i echipamentul, lu\u00e2nd \u00een calcul o marj\u0103 verificat\u0103 pentru c\u0103derile de tensiune, tensiunea minim\u0103 de intrare a convertorului \u0219i timpul de recuperare.<\/p><h3 class=\"wp-block-heading\">De ce camera nu porne\u0219te din nou imediat ce r\u0103sare soarele?<\/h3><p class=\"wp-block-paragraph\">Controlerul poate necesita o tensiune de reconectare mai mare, o \u00eent\u00e2rziere sau alte condi\u021bii. De asemenea, energia solar\u0103 ar putea fi insuficient\u0103 pentru a asigura pornirea camerei dup\u0103 reconectare. M\u0103sura\u021bi at\u00e2t tensiunea, c\u00e2t \u0219i curentul \u00een timpul procesului de recuperare.<\/p><h3 class=\"wp-block-heading\">Ad\u0103ugarea unei alte baterii de 100 Ah va rezolva problema declan\u0219\u0103rii premature a alertei de nivel sc\u0103zut al tensiunii (LVD)?<\/h3><p class=\"wp-block-paragraph\">Nu neap\u0103rat. Pachetele paralele aprobate adaug\u0103 energie \u0219i pot reduce c\u0103derile de tensiune, dar set\u0103rile LVD \u0219i ale \u00eenc\u0103rc\u0103torului r\u0103m\u00e2n valabile. Verifica\u021bi compatibilitatea pragurilor \u0219i capacitatea de \u00eenc\u0103rcare \u00eenainte de a extinde sistemul.<\/p><h2 class=\"wp-block-heading\">Concluzie<\/h2><p class=\"wp-block-paragraph\">Un switch solar PoE <strong>poate<\/strong> deconecta\u021bi sarcinile sistemului CCTV \u00eenainte ca un acumulator cu ioni de sodiu s\u0103 ating\u0103 limita de protec\u021bie stabilit\u0103 de sistemul BMS. Energia care r\u0103m\u00e2ne inaccesibil\u0103 depinde de <strong>Wh m\u0103surat<\/strong>, LVD\/LVR, bugetul de sarcin\u0103, pierderile din cablaj \u0219i repornirea \u2014 nu doar pragul de 8 V sau valoarea nominal\u0103 de 1.200 Wh. Verifica\u021bi mai \u00eent\u00e2i compatibilitatea \u00eenc\u0103rc\u0103rii, \u00een special <strong>Limita bateriei de 15,6 V<\/strong> \u00een raport cu intervalul programabil \u0219i protec\u021biile de temperatur\u0103 ale controlerului. Pentru un <a href=\"https:\/\/www.kmdpower.com\/ro\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Baterie cu ioni de sodiu Kamada Power de 12 V \u0219i 100 Ah<\/a>, <a href=\"https:\/\/www.kmdpower.com\/ro\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">contacta\u021bi Kamada Power<\/a> cu modelul PoE, set\u0103rile de \u00eenc\u0103rcare\/LVD\/LVR, sarcina, temperaturile \u0219i volumul estimat. Solicita\u021bi un plan de testare a compatibilit\u0103\u021bii specific reviziei \u00eenainte de achizi\u021bionare.<\/p>","protected":false},"excerpt":{"rendered":"<p>O sta\u021bie de supraveghere video la distan\u021b\u0103 \u00eenceteaz\u0103 s\u0103 mai \u00eenregistreze \u00eenainte de r\u0103s\u0103rit. Comutatorul PoE solar semnaleaz\u0103 o oprire din cauza bateriei desc\u0103rcate, dar pachetul de baterii cu ioni de sodiu nu a intrat \u00een starea de protec\u021bie \u00eempotriva subtensiunii a sistemului BMS. Este bateria subdimensionat\u0103 sau comutatorul a deconectat sarcina \u00eenainte de timp? Un comutator PoE solar poate deconecta camerele \u00eenainte ca pachetul de baterii s\u0103 ating\u0103 limita de desc\u0103rcare, dar o tensiune\u2026<\/p>","protected":false},"author":1,"featured_media":1181,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5305","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/posts\/5305","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/comments?post=5305"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/posts\/5305\/revisions"}],"predecessor-version":[{"id":5307,"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/posts\/5305\/revisions\/5307"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/media?parent=5305"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/categories?post=5305"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/ro\/wp-json\/wp\/v2\/tags?post=5305"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}