{"id":5335,"date":"2026-11-25T05:36:02","date_gmt":"2026-11-25T05:36:02","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5335"},"modified":"2026-11-25T05:36:04","modified_gmt":"2026-11-25T05:36:04","slug":"can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/pt\/news\/can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route\/","title":{"rendered":"Ser\u00e1 que uma bateria de i\u00f5es de s\u00f3dio consegue manter as portas elevat\u00f3rias dos cami\u00f5es a funcionar ao longo de toda uma rota de entregas de inverno?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Uma bateria da porta elevat\u00f3ria totalmente carregada n\u00e3o garante energia suficiente para a \u00faltima entrega. As opera\u00e7\u00f5es hidr\u00e1ulicas repetidas, os percursos curtos e as restri\u00e7\u00f5es de carregamento no inverno criam d\u00e9fices cumulativos. Para os fabricantes de equipamento original (OEM) de portas elevat\u00f3rias e os empresas de adapta\u00e7\u00e3o de ve\u00edculos, <strong><a href=\"https:\/\/www.kmdpower.com\/pt\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">bateria de s\u00f3dio<\/a><\/strong> A adequa\u00e7\u00e3o depende da energia dispon\u00edvel no ponto mais dif\u00edcil do percurso, de pot\u00eancia motora suficiente e da recarga antes do dia \u00fatil seguinte.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Sodium-Battery-12V-100Ah-Bluetooth-Low-Temperature-Na-Ion-Battery-Supplier-Factory-Manufacturers-001.jpg\" alt=\"\" class=\"wp-image-1451\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/pt\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bateria de i\u00f5es de s\u00f3dio Kamada Power 12v 100Ah<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Por que raz\u00e3o as paragens repetidas criam um d\u00e9fice energ\u00e9tico na porta traseira elevat\u00f3ria?<\/h2><p class=\"wp-block-paragraph\">A bateria da porta traseira elevat\u00f3ria alimenta o equipamento hidr\u00e1ulico nas paragens e pode recarregar-se durante o trajeto. A <a href=\"https:\/\/purkeys.net\/case-study-how-purkeys-direct-helped-keep-under-charged-liftgates-off-the-road\/\" target=\"_blank\" rel=\"noreferrer noopener\">caso da frota relatado por Purkeys<\/a> descreve o caso de baterias descarregadas que impedem a subida das plataformas, o que obriga a recorrer ao servi\u00e7o de assist\u00eancia em estrada. N\u00e3o se trata de um ensaio de campo com baterias de i\u00f5es de s\u00f3dio.<\/p><p class=\"wp-block-paragraph\">Um cami\u00e3o pode descarregar v\u00e1rios paletes e conduzir apenas alguns minutos at\u00e9 ao pr\u00f3ximo cliente. Uma bateria cheia pode ocultar uma carga insuficiente no primeiro dia, caso a carga noturna no dep\u00f3sito seja insuficiente.<\/p><p class=\"wp-block-paragraph\">O inverno afeta tanto a oferta como a procura de energia. As baterias frias podem ter menos energia dispon\u00edvel e limites de carga mais baixos. O fluido hidr\u00e1ulico frio pode afetar a autonomia de funcionamento e a procura do motor, dependendo do fluido, da bomba e do design do equipamento. \u00c9 prefer\u00edvel medir estes efeitos em vez de aplicar um fator de corre\u00e7\u00e3o universal para o inverno.<\/p><p class=\"wp-block-paragraph\">Cabos e liga\u00e7\u00f5es longos podem reduzir a tens\u00e3o de carregamento. Um carregador CC-CC espec\u00edfico para a porta traseira elevat\u00f3ria pode compensar esta perda, mas a sua presen\u00e7a n\u00e3o garante a compatibilidade com baterias de i\u00f5es de s\u00f3dio.<\/p><h2 class=\"wp-block-heading\">Quanta energia consome um percurso de entregas com carga completa?<\/h2><p class=\"wp-block-paragraph\">A pot\u00eancia indicada na placa de identifica\u00e7\u00e3o do motor n\u00e3o determina o consumo di\u00e1rio de energia. O peso da carga, a altura de eleva\u00e7\u00e3o, a efici\u00eancia hidr\u00e1ulica e a dura\u00e7\u00e3o do funcionamento influenciam o consumo, tal como o facto de a descida ser motorizada ou assistida pela gravidade.<\/p><p class=\"wp-block-paragraph\">Me\u00e7a a tens\u00e3o e a corrente nos terminais da bateria durante opera\u00e7\u00f5es representativas da porta traseira elevat\u00f3ria. A energia el\u00e9trica consumida por um ciclo \u00e9:<\/p><p class=\"wp-block-paragraph\"><strong>Energia do ciclo (Wh) = integral de V(t) \u00d7 I(t) ao longo do tempo \u00f7 3 600<\/strong><\/p><p class=\"wp-block-paragraph\">A tens\u00e3o \u00e9 medida em volts, a corrente em amperes e o tempo em segundos.<\/p><p class=\"wp-block-paragraph\">Registe separadamente as eleva\u00e7\u00f5es com carga, os movimentos sem carga, os retornos e os per\u00edodos de espera, incluindo paragens excepcionalmente exigentes. N\u00e3o conte os retornos duas vezes se j\u00e1 estiverem inclu\u00eddos num ciclo completo.<\/p><p class=\"wp-block-paragraph\">O percurso hipot\u00e9tico que se segue ilustra o c\u00e1lculo. Para dar uma ideia da escala, o <a href=\"https:\/\/www.maxonlift.com\/sites\/default\/files\/manuals\/2017-01\/operators-handbook-gpc-x1-ld-gpc-x1-ldf-20908422_2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Manual do operador do MAXON GPC X1-LD\/LDF, p\u00e1gina 5<\/a> refere 150 A a 12 V e recomenda uma bateria de 88 Ah para o seu exemplo de capacidade de 600 kg. A 12 V e 150 A, 36 segundos de funcionamento motorizado equivalente consomem 18 Wh. Trata-se de uma ilustra\u00e7\u00e3o de ordem de grandeza, n\u00e3o de um ciclo medido nem de uma afirma\u00e7\u00e3o de que a corrente permanece constante.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Par\u00e2metro de energia da rota<\/th><th class=\"has-text-align-right\" data-align=\"right\">Valor ilustrativo<\/th><\/tr><\/thead><tbody><tr><td>Ciclos completos de eleva\u00e7\u00e3o e retorno<\/td><td class=\"has-text-align-right\" data-align=\"right\">30<\/td><\/tr><tr><td>Energia m\u00e9dia por ciclo<\/td><td class=\"has-text-align-right\" data-align=\"right\">18 Wh<\/td><\/tr><tr><td>Energia necess\u00e1ria para o funcionamento da porta traseira elevat\u00f3ria<\/td><td class=\"has-text-align-right\" data-align=\"right\">540 Wh<\/td><\/tr><tr><td>Consumo do controlador e do modo de espera<\/td><td class=\"has-text-align-right\" data-align=\"right\">60 Wh<\/td><\/tr><tr><td>Procura total de energia nos terminais da bateria<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Tempo efetivo de carregamento do ve\u00edculo<\/td><td class=\"has-text-align-right\" data-align=\"right\">2 horas<\/td><\/tr><tr><td>Pot\u00eancia m\u00e9dia de carregamento aceite<\/td><td class=\"has-text-align-right\" data-align=\"right\">120 W<\/td><\/tr><tr><td>Energia fornecida aos terminais da bateria<\/td><td class=\"has-text-align-right\" data-align=\"right\">240 Wh<\/td><\/tr><tr><td>D\u00e9fice energ\u00e9tico di\u00e1rio no terminal<\/td><td class=\"has-text-align-right\" data-align=\"right\">360 Wh<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">O ve\u00edculo recupera apenas 40% da energia consumida. Os restantes 360 Wh t\u00eam de ser retirados da reserva da bateria existente, tendo ainda de se ter em conta as perdas internas da bateria. Cinco dias \u00fateis id\u00eanticos sem carregamento adicional resultariam num d\u00e9fice energ\u00e9tico acumulado de 1 800 Wh.<\/p><p class=\"wp-block-paragraph\">A sufici\u00eancia energ\u00e9tica n\u00e3o equivale \u00e0 compatibilidade do motor. Uma refer\u00eancia t\u00e9cnica do Kamada Power 12 V\/100 Ah indica uma descarga cont\u00ednua m\u00e1xima de 100 A e um pulso de 150 A com dura\u00e7\u00e3o inferior a 3 milissegundos. Esses valores n\u00e3o permitem que um \u00fanico conjunto de baterias suporte um esfor\u00e7o de 150 A com dura\u00e7\u00e3o de v\u00e1rios segundos. Verifique o perfil de corrente-dura\u00e7\u00e3o do motor, incluindo a corrente de arranque, os rein\u00edcios sob carga e os limites t\u00e9rmicos de ciclos repetidos, em compara\u00e7\u00e3o com os limites aprovados da bateria \u00e0 temperatura prevista. Verifique a tens\u00e3o m\u00ednima nos terminais do motor. Uma queda excessiva de tens\u00e3o no cabo ou uma desconex\u00e3o do sistema de gest\u00e3o da bateria (BMS) pode interromper o funcionamento, mesmo quando ainda existe energia armazenada. O corte de prote\u00e7\u00e3o de 8 V mencionado nessa refer\u00eancia n\u00e3o constitui, por defeito, uma tens\u00e3o de funcionamento aceit\u00e1vel para o motor.<\/p><h2 class=\"wp-block-heading\">O tempo de condu\u00e7\u00e3o no inverno pode compensar a energia consumida em cada paragem?<\/h2><p class=\"wp-block-paragraph\">Um carregador CC-CC com uma pot\u00eancia nominal de 40 A n\u00e3o fornece necessariamente 40 A \u00e0 bateria da porta traseira durante uma viagem de inverno. A corrente de carregamento aceit\u00e1vel depende da alimenta\u00e7\u00e3o el\u00e9trica do ve\u00edculo, das caracter\u00edsticas de sa\u00edda do carregador, da temperatura e do estado de carga (SOC) da bateria, bem como dos limites especificados para a bateria em si.<\/p><p class=\"wp-block-paragraph\">A energia fornecida durante cada intervalo de condu\u00e7\u00e3o \u00e9:<\/p><p class=\"wp-block-paragraph\"><strong>Energia de carregamento (Wh) = integral de Vcharge(t) \u00d7 Iaccepted(t) ao longo do tempo \u00f7 3 600<\/strong><\/p><p class=\"wp-block-paragraph\">Utilize a corrente efetivamente consumida pela bateria, e n\u00e3o a corrente m\u00e1xima indicada na placa de caracter\u00edsticas do carregador. Nos casos em que as cargas auxiliares permane\u00e7am ativas durante a condu\u00e7\u00e3o, considere-as separadamente ou utilize sempre a pot\u00eancia l\u00edquida nos terminais da bateria.<\/p><p class=\"wp-block-paragraph\">Considere uma tens\u00e3o de carregamento hipot\u00e9tica de 13,5 V e um intervalo de condu\u00e7\u00e3o de 15 minutos. A 10 A, a bateria recebe 33,75 Wh. A 20 A, recebe 67,5 Wh. A 40 A, recebe 135 Wh. Estes valores pressup\u00f5em tens\u00e3o e corrente constantes e excluem as perdas internas de armazenamento. N\u00e3o se trata de especifica\u00e7\u00f5es de corrente de carregamento para uma bateria Kamada Power.<\/p><p class=\"wp-block-paragraph\">Para contextualizar, a refer\u00eancia t\u00e9cnica de 12 V\/100 Ah indica 10 A entre \u221220 \u00b0C e \u221210 \u00b0C e 20 A entre \u221210 \u00b0C e 0 \u00b0C. Estes limites s\u00e3o espec\u00edficos de cada revis\u00e3o. A refer\u00eancia descreve o carregamento CC\/CV padr\u00e3o entre 0 e 45 \u00b0C; confirme separadamente os limites de tens\u00e3o, corrente, desligamento, temperatura abaixo de zero e o comportamento do BMS. Um carregador de maior pot\u00eancia n\u00e3o pode ultrapassar esses limites. A regula\u00e7\u00e3o de corrente de rotina tamb\u00e9m n\u00e3o deve depender dos desligamentos de prote\u00e7\u00e3o do BMS. O <a href=\"https:\/\/www.purkeys.net\/wp-content\/uploads\/2018\/07\/Direct-01-Installation-Guide.pdf\" target=\"_blank\" rel=\"noopener\">Guia de instala\u00e7\u00e3o do Purkeys Direct<\/a> descreve o aumento da tens\u00e3o de carga em climas frios. Por conseguinte, \u00e9 necess\u00e1rio verificar se o perfil de compensa\u00e7\u00e3o de temperatura existente para baterias de chumbo-\u00e1cido est\u00e1 em conformidade com os limites de tens\u00e3o e corrente aprovados para a bateria de i\u00f5es de s\u00f3dio; o valor m\u00e1ximo de refer\u00eancia de 15,6 V \u00e9 um limite m\u00e1ximo, n\u00e3o um ponto de regula\u00e7\u00e3o universal para a carga.<\/p><p class=\"wp-block-paragraph\">Uma bateria aprovada para carregamento a temperaturas abaixo de zero pode constituir uma alternativa aos sistemas que restringem o carregamento a temperaturas abaixo de zero, desde que sejam cumpridos os requisitos relativos \u00e0 corrente do motor e \u00e0 tens\u00e3o. A investiga\u00e7\u00e3o sobre as c\u00e9lulas, por si s\u00f3, n\u00e3o permite determinar os limites de carregamento da bateria finalizada nem a recupera\u00e7\u00e3o de energia no inverno.<\/p><p class=\"wp-block-paragraph\">\u00c9 a temperatura da bateria, e n\u00e3o a temperatura ambiente, que determina o limite de carregamento aplic\u00e1vel. Um conjunto de baterias montado num reboque pode permanecer frio depois de o motor aquecer, limitando a recarga durante viagens curtas.<\/p><p class=\"wp-block-paragraph\">Um intervalo de condu\u00e7\u00e3o de cinco minutos a 120 W fornece apenas 10 Wh. Se a opera\u00e7\u00e3o anterior da porta traseira tiver consumido 18 Wh, fica a registar-se um d\u00e9fice de energia terminal de mais 8 Wh, mesmo antes de se terem em conta as perdas de armazenamento. Intervalos de condu\u00e7\u00e3o mais longos, mais tarde no dia, podem recuperar esse d\u00e9fice, mas n\u00e3o podem compensar uma entrega que ocorra antes desses intervalos.<\/p><h2 class=\"wp-block-heading\">Em que ponto do percurso a reserva de energia atinge o seu n\u00edvel mais baixo?<\/h2><p class=\"wp-block-paragraph\">Os percursos com consumo di\u00e1rio, pot\u00eancia de carregamento e reserva final id\u00eanticos podem ter requisitos m\u00ednimos de energia diferentes, uma vez que os eventos de entrega e carregamento ocorrem em ordens diferentes.<\/p><p class=\"wp-block-paragraph\">Voltemos ao percurso hipot\u00e9tico que consome 600 Wh e recebe 240 Wh de energia de carregamento. Suponhamos que come\u00e7a com 800 Wh de energia armazenada dispon\u00edvel. Divida a procura em tr\u00eas blocos de fornecimento de 200 Wh, incluindo o consumo em modo de espera atribu\u00eddo, e o fornecimento de carga em dois blocos de 120 Wh. Para esta compara\u00e7\u00e3o simplificada, suponha que a energia de carga \u00e9 totalmente recuper\u00e1vel, que a temperatura \u00e9 constante e que nenhum dos blocos de carga se depara com uma bateria totalmente carregada.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Fase operacional<\/th><th class=\"has-text-align-right\" data-align=\"right\">Percurso A \u2014 Entregas distribu\u00eddas<\/th><th class=\"has-text-align-right\" data-align=\"right\">Percurso B \u2014 Entregas concentradas<\/th><\/tr><\/thead><tbody><tr><td>Partida<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><\/tr><tr><td>Primeiro bloco de entregas<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Pr\u00f3ximo evento<\/td><td class=\"has-text-align-right\" data-align=\"right\">720 Wh (carga)<\/td><td class=\"has-text-align-right\" data-align=\"right\">400 Wh (pot\u00eancia fornecida)<\/td><\/tr><tr><td>Pr\u00f3ximo evento<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (pot\u00eancia \u00fatil)<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (carga)<\/td><\/tr><tr><td>Pr\u00f3ximo bloco de carregamento<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><\/tr><tr><td>Bloco de entrega final<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><\/tr><tr><td>Energia m\u00ednima restante<\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>440 Wh<\/strong><\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>400 Wh<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png\" alt=\"\" class=\"wp-image-5338\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Ambas as rotas terminam com 440 Wh. A rota B, no entanto, atinge a sua reserva m\u00ednima antes da primeira oportunidade significativa de recarga. Partindo do princ\u00edpio de uma reserva m\u00ednima de funcionamento de 420 Wh, a rota A cumpre o requisito energ\u00e9tico, enquanto a rota B n\u00e3o o cumpre.<\/p><p class=\"wp-block-paragraph\">Para o modelo simplificado de temperatura constante e sem perdas:<\/p><p class=\"wp-block-paragraph\"><strong>Energia \u00fatil inicial necess\u00e1ria \u2265 d\u00e9fice energ\u00e9tico acumulado m\u00e1ximo do percurso + reserva operacional necess\u00e1ria.<\/strong><\/p><p class=\"wp-block-paragraph\">Nas condi\u00e7\u00f5es ilustrativas, o d\u00e9fice acumulado m\u00e1ximo \u00e9 de 360 Wh para o Percurso A e de 400 Wh para o Percurso B. Para manter uma reserva de 420 Wh, s\u00e3o necess\u00e1rios, respetivamente, pelo menos 780 Wh e 820 Wh de energia utiliz\u00e1vel inicial. A reserva de 420 Wh \u00e9 meramente ilustrativa, n\u00e3o constituindo uma recomenda\u00e7\u00e3o universal. Defina a reserva efetiva tendo em conta os ciclos de eleva\u00e7\u00e3o restantes essenciais, entregas inesperadas, envelhecimento e incertezas relacionadas com o tempo frio; verifique a tens\u00e3o de carga de forma independente.<\/p><p class=\"wp-block-paragraph\">Na pr\u00e1tica, acompanhe a energia dispon\u00edvel ap\u00f3s cada segmento de fornecimento e carregamento. Limite a reposi\u00e7\u00e3o ao espa\u00e7o de armazenamento dispon\u00edvel e tenha em conta as perdas internas. Reavalie a energia dispon\u00edvel \u00e0 medida que a temperatura de funcionamento varia.<\/p><h2 class=\"wp-block-heading\">Quando \u00e9 que uma atualiza\u00e7\u00e3o do sistema de carregamento \u00e9 mais eficaz do que uma nova bateria?<\/h2><p class=\"wp-block-paragraph\">Para os fabricantes de equipamento original (OEM) que estejam a avaliar um <a href=\"https:\/\/www.kmdpower.com\/pt\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bateria de i\u00f5es de s\u00f3dio de 12V 100Ah<\/a>, as configura\u00e7\u00f5es em paralelo aprovadas pelo fabricante constituem uma forma potencial de aumentar a capacidade de armazenamento. Numa base de projeto nominal ilustrativa de 12 V, 1P, 2P, 3P e 4P representam 100 Ah, 200 Ah, 300 Ah e 400 Ah, ou 1 200 Wh, 2 400 Wh, 3 600 Wh e 4 800 Wh, respetivamente. Trata-se de c\u00e1lculos nominais, n\u00e3o de energia \u00fatil medida. O cat\u00e1logo indicado no link apresenta um modelo de 12,8 V; a refer\u00eancia t\u00e9cnica de 12 V aqui utilizada n\u00e3o deve ser considerada como pertencendo \u00e0 mesma revis\u00e3o sem confirma\u00e7\u00e3o pr\u00e9via. Obtenha o SKU exato e os limites aprovados antes da aprova\u00e7\u00e3o do projeto.<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png\" alt=\"\" class=\"wp-image-5336\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Se um conjunto n\u00e3o conseguir fornecer os 820 Wh necess\u00e1rios para o percurso concentrado, considere uma configura\u00e7\u00e3o aprovada de maior capacidade. Determine a energia dispon\u00edvel \u00e0 temperatura prevista e \u00e0 tens\u00e3o de funcionamento do equipamento, e n\u00e3o apenas com base na capacidade nominal.<\/p><p class=\"wp-block-paragraph\">Com um carregamento noturno suficiente na base, um conjunto de baterias de maior capacidade permite dar resposta a entregas concentradas sem necessidade de um carregador de ve\u00edculos de pot\u00eancia superior.<\/p><p class=\"wp-block-paragraph\">Sem carregamento durante a noite, a capacidade adicional apenas adia o d\u00e9fice di\u00e1rio recorrente de 360 Wh.<\/p><p class=\"wp-block-paragraph\">Para o percurso de exemplo, equilibrar 600 Wh de procura di\u00e1ria no terminal ao longo de duas horas de carregamento efetivo requer uma m\u00e9dia de, pelo menos, 300 W. A uma tens\u00e3o de carregamento ilustrativa de 13,5 V, isso corresponde a aproximadamente 22,2 A de corrente admitida, antes de se ter em conta as perdas internas de armazenamento. A 13,5 V, um \u00fanico conjunto limitado a 10 A ou 20 A recebe apenas 270 Wh ou 540 Wh em duas horas, o que deixa um d\u00e9fice de 330 Wh ou 60 Wh antes das perdas. Considere a capacidade de carregamento em paralelo aprovada, intervalos de carregamento mais longos ou carregamento em dep\u00f3sito; um carregador de maior pot\u00eancia, por si s\u00f3, n\u00e3o consegue superar os limites do conjunto de baterias.<\/p><p class=\"wp-block-paragraph\">A decis\u00e3o de aquisi\u00e7\u00e3o obedece a quatro condi\u00e7\u00f5es:<\/p><ul class=\"wp-block-list\"><li><strong>Escassez tempor\u00e1ria de energia:<\/strong> Aumente a capacidade de armazenamento dispon\u00edvel ou antecipe uma oportunidade de carregamento dispon\u00edvel antes do per\u00edodo de entregas mais intenso.<\/li>\n\n<li><strong>Cobran\u00e7a insuficiente recorrente:<\/strong> Melhorar o reabastecimento compat\u00edvel atrav\u00e9s do carregamento em ve\u00edculos ou em dep\u00f3sitos.<\/li>\n\n<li><strong>Ambas as condi\u00e7\u00f5es:<\/strong> Compare os requisitos combinados de armazenamento e carregamento utilizando o registo cronol\u00f3gico de percursos.<\/li>\n\n<li><strong>Incompatibilidade do motor ou da tens\u00e3o:<\/strong> Rejeite a substitui\u00e7\u00e3o direta e considere uma plataforma OEM concebida especificamente para o efeito.<\/li><\/ul><p class=\"wp-block-paragraph\">Para uma carga operacional de 150 A, a reparti\u00e7\u00e3o ideal entre os conjuntos 1P, 2P, 3P e 4P resulta em 150 A, 75 A, 50 A e 37,5 A por conjunto, respetivamente. Com o limite cont\u00ednuo de refer\u00eancia de 100 A, o 1P n\u00e3o cumpre este crit\u00e9rio inicial de corrente sustentada; os 2P\u20134P merecem avalia\u00e7\u00e3o, n\u00e3o aprova\u00e7\u00e3o autom\u00e1tica. Um banco 2P poderia deixar o pacote restante a suportar 150 A se um ramo se desligasse. \u00c9 necess\u00e1rio estabelecer a partilha efetiva, os limites a baixas temperaturas, a prote\u00e7\u00e3o dos ramos e o comportamento de desligamento seguro. Se as configura\u00e7\u00f5es em paralelo aprovadas n\u00e3o conseguirem satisfazer os requisitos do motor ou de carregamento, deve avaliar-se um conjunto OEM de alta pot\u00eancia, em vez de contornar a prote\u00e7\u00e3o. As adapta\u00e7\u00f5es devem cumprir os requisitos el\u00e9tricos e as condi\u00e7\u00f5es de aprova\u00e7\u00e3o dos fabricantes de ve\u00edculos e de portas traseiras elevat\u00f3rias.<\/p><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png\" alt=\"\" class=\"wp-image-5337\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><h2 class=\"wp-block-heading\">FAQ<\/h2><h3 class=\"wp-block-heading\">Uma bateria de 100 Ah consegue alimentar uma porta traseira elevat\u00f3ria?<\/h3><p class=\"wp-block-paragraph\">Potencialmente. Uma bateria de i\u00f5es de s\u00f3dio de 100 Ah pronta a utilizar deve satisfazer os requisitos de corrente e dura\u00e7\u00e3o do motor hidr\u00e1ulico, os limites de tens\u00e3o sob carga e o d\u00e9fice energ\u00e9tico acumulado m\u00e1ximo ao longo do percurso. Se um conjunto for insuficiente, podem ser consideradas configura\u00e7\u00f5es em paralelo aprovadas pelo fabricante ou uma bateria OEM concebida de forma independente. A capacidade nominal n\u00e3o garante a compatibilidade para substitui\u00e7\u00e3o direta.<\/p><h3 class=\"wp-block-heading\">Ser\u00e1 que duas baterias resolvem o problema dos intervalos curtos de condu\u00e7\u00e3o?<\/h3><p class=\"wp-block-paragraph\">Duas baterias ligadas em paralelo e aprovadas podem proporcionar uma maior reserva operacional entre as oportunidades de carregamento. No entanto, n\u00e3o aumentam necessariamente a energia recuperada durante percursos curtos. Se o consumo di\u00e1rio continuar a exceder a reposi\u00e7\u00e3o de energia, continua a ser necess\u00e1ria uma atualiza\u00e7\u00e3o do sistema de carregamento compat\u00edvel ou carregamento adicional na base.<\/p><h3 class=\"wp-block-heading\">Um carregador CC\/CC necessita de um perfil de i\u00f5es de s\u00f3dio?<\/h3><p class=\"wp-block-paragraph\">O carregador deve cumprir os requisitos de tens\u00e3o, corrente, temperatura e interrup\u00e7\u00e3o do carregamento da bateria selecionada. Um perfil espec\u00edfico para i\u00f5es de s\u00f3dio pode ser adequado, mas o seu nome n\u00e3o garante a compatibilidade. As configura\u00e7\u00f5es existentes para baterias de chumbo-\u00e1cido ou de i\u00f5es de l\u00edtio s\u00f3 devem ser utilizadas se o seu comportamento real for aprovado para a configura\u00e7\u00e3o espec\u00edfica da bateria e do equipamento.<\/p><h2 class=\"wp-block-heading\">Conclus\u00e3o<\/h2><p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/pt\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Baterias de i\u00f5es de s\u00f3dio<\/a><\/strong> s\u00e3o uma op\u00e7\u00e3o para sistemas de porta elevat\u00f3ria de cami\u00f5es de inverno quando a sua energia \u00fatil, a capacidade de corrente do motor, a tens\u00e3o de funcionamento e os limites de carregamento dependentes da temperatura correspondem ao ciclo de trabalho de entrega. O d\u00e9fice cumulativo m\u00e1ximo da rota determina a energia de arranque necess\u00e1ria, enquanto o saldo de recarga di\u00e1ria determina se o sistema consegue suportar dias de trabalho consecutivos. Para os modelos padr\u00e3o <strong><a href=\"https:\/\/www.kmdpower.com\/pt\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bateria de i\u00f5es de s\u00f3dio de 12V 100Ah<\/a><\/strong>, configura\u00e7\u00f5es paralelas aprovadas ou poss\u00edveis projetos personalizados de baterias para portas traseiras elevat\u00f3rias, <a href=\"https:\/\/www.kmdpower.com\/pt\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">contacte a Kamada Power<\/a> com a sua rota de entregas de inverno mais longa, o perfil de corrente do motor hidr\u00e1ulico, as especifica\u00e7\u00f5es de carregamento do ve\u00edculo e o intervalo de temperatura previsto da bateria, para discutirmos uma arquitetura de bateria e carregamento espec\u00edfica para a sua aplica\u00e7\u00e3o.<\/p>","protected":false},"excerpt":{"rendered":"<p>Uma bateria da porta elevat\u00f3ria totalmente carregada n\u00e3o garante energia suficiente para a \u00faltima entrega. As opera\u00e7\u00f5es hidr\u00e1ulicas repetidas, os percursos curtos e as restri\u00e7\u00f5es de carregamento no inverno criam d\u00e9fices cumulativos. Para os fabricantes de equipamento original (OEM) de portas elevat\u00f3rias e os equipadores de ve\u00edculos, a adequa\u00e7\u00e3o das baterias de s\u00f3dio depende da energia utiliz\u00e1vel no ponto mais exigente do percurso, de pot\u00eancia suficiente do motor e da recarga antes do pr\u00f3ximo turno de trabalho\u2026<\/p>","protected":false},"author":1,"featured_media":1451,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/posts\/5335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/comments?post=5335"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/posts\/5335\/revisions"}],"predecessor-version":[{"id":5339,"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/posts\/5335\/revisions\/5339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/media\/1451"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/media?parent=5335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/categories?post=5335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/pt\/wp-json\/wp\/v2\/tags?post=5335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}