{"id":5335,"date":"2026-11-25T05:36:02","date_gmt":"2026-11-25T05:36:02","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5335"},"modified":"2026-11-25T05:36:04","modified_gmt":"2026-11-25T05:36:04","slug":"can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/fr\/news\/can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route\/","title":{"rendered":"Une batterie au sodium-ion peut-elle assurer le bon fonctionnement des hayons \u00e9l\u00e9vateurs des camions tout au long d'un itin\u00e9raire de livraison hivernal complet ?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Une batterie de hayon \u00e9l\u00e9vateur enti\u00e8rement charg\u00e9e ne garantit pas une autonomie suffisante pour la derni\u00e8re livraison. Les op\u00e9rations hydrauliques r\u00e9p\u00e9t\u00e9es, les trajets courts et les restrictions de recharge en hiver entra\u00eenent des d\u00e9ficits cumul\u00e9s. Pour les \u00e9quipementiers de hayons \u00e9l\u00e9vateurs et les pr\u00e9parateurs de v\u00e9hicules, <strong><a href=\"https:\/\/www.kmdpower.com\/fr\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">batterie au sodium<\/a><\/strong> La pertinence de cette solution d\u00e9pend de la quantit\u00e9 d'\u00e9nergie disponible au point le plus difficile du parcours, d'une puissance moteur suffisante et d'un r\u00e9approvisionnement avant le jour ouvrable suivant.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Sodium-Battery-12V-100Ah-Bluetooth-Low-Temperature-Na-Ion-Battery-Supplier-Factory-Manufacturers-001.jpg\" alt=\"\" class=\"wp-image-1451\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/fr\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100Ah Sodium ion Battery<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Pourquoi les arr\u00eats r\u00e9p\u00e9t\u00e9s entra\u00eenent-ils un d\u00e9ficit \u00e9nerg\u00e9tique au niveau du hayon \u00e9l\u00e9vateur ?<\/h2><p class=\"wp-block-paragraph\">La batterie du hayon \u00e9l\u00e9vateur alimente le syst\u00e8me hydraulique lors des arr\u00eats et peut se recharger pendant le trajet. A <a href=\"https:\/\/purkeys.net\/case-study-how-purkeys-direct-helped-keep-under-charged-liftgates-off-the-road\/\" target=\"_blank\" rel=\"noreferrer noopener\">cas concernant la flotte signal\u00e9 par Purkeys<\/a> d\u00e9crit le cas de batteries d\u00e9charg\u00e9es emp\u00eachant les plates-formes de se relever, ce qui n\u00e9cessite une intervention sur route. Il ne s'agit pas d'un essai sur le terrain de batteries sodium-ion.<\/p><p class=\"wp-block-paragraph\">Un camion peut d\u00e9charger plusieurs palettes et se rendre chez le client suivant en quelques minutes seulement. Une batterie pleine peut masquer une charge insuffisante d\u00e8s le premier jour si la recharge nocturne au d\u00e9p\u00f4t s'av\u00e8re insuffisante.<\/p><p class=\"wp-block-paragraph\">L'hiver a une incidence tant sur l'offre que sur la demande d'\u00e9nergie. Les batteries froides peuvent pr\u00e9senter une \u00e9nergie disponible r\u00e9duite et des limites de charge plus basses. Un fluide hydraulique froid peut affecter la dur\u00e9e de fonctionnement et la demande du moteur, en fonction du fluide, de la pompe et de la conception de l'\u00e9quipement. Il convient de mesurer ces effets plut\u00f4t que d'appliquer un facteur de correction hivernal universel.<\/p><p class=\"wp-block-paragraph\">Les c\u00e2bles et les raccordements trop longs peuvent r\u00e9duire la tension de charge. Un chargeur CC-CC d\u00e9di\u00e9, install\u00e9 sur le hayon, peut compenser cette perte, mais sa pr\u00e9sence ne garantit pas la compatibilit\u00e9 avec les batteries au sodium-ion.<\/p><h2 class=\"wp-block-heading\">Quelle est la consommation d'\u00e9nergie d'un itin\u00e9raire de livraison \u00e0 pleine charge ?<\/h2><p class=\"wp-block-paragraph\">La puissance nominale indiqu\u00e9e sur la plaque signal\u00e9tique du moteur ne permet pas de d\u00e9terminer la consommation \u00e9nerg\u00e9tique quotidienne. Le poids de la charge, la hauteur de levage, le rendement hydraulique et la dur\u00e9e de fonctionnement ont une incidence sur la consommation, tout comme le fait d'opter pour une descente motoris\u00e9e plut\u00f4t qu'assist\u00e9e par gravit\u00e9.<\/p><p class=\"wp-block-paragraph\">Mesurez la tension et le courant aux bornes de la batterie tout au long d'op\u00e9rations repr\u00e9sentatives du hayon \u00e9l\u00e9vateur. L'\u00e9nergie \u00e9lectrique consomm\u00e9e par cycle est la suivante :<\/p><p class=\"wp-block-paragraph\"><strong>\u00c9nergie du cycle (Wh) = int\u00e9grale de V(t) \u00d7 I(t) sur la dur\u00e9e \u00f7 3 600<\/strong><\/p><p class=\"wp-block-paragraph\">La tension s'exprime en volts, le courant en amp\u00e8res et le temps en secondes.<\/p><p class=\"wp-block-paragraph\">Enregistrez s\u00e9par\u00e9ment les mont\u00e9es en charge, les d\u00e9placements \u00e0 vide, les retours et les temps d'attente, y compris les arr\u00eats particuli\u00e8rement exigeants. Ne comptez pas deux fois les retours s'ils sont d\u00e9j\u00e0 inclus dans un cycle complet.<\/p><p class=\"wp-block-paragraph\">L'itin\u00e9raire hypoth\u00e9tique suivant illustre ce calcul. \u00c0 titre de r\u00e9f\u00e9rence, le <a href=\"https:\/\/www.maxonlift.com\/sites\/default\/files\/manuals\/2017-01\/operators-handbook-gpc-x1-ld-gpc-x1-ldf-20908422_2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Manuel d'utilisation du MAXON GPC X1-LD\/LDF, page 5<\/a> indique 150 A \u00e0 12 V et recommande une batterie de 88 Ah pour son exemple de capacit\u00e9 de 600 kg. \u00c0 12 V et 150 A, 36 secondes de fonctionnement en charge \u00e9quivalente consomment 18 Wh. Il s'agit d'une illustration d'ordre de grandeur, et non d'un cycle mesur\u00e9 ni d'une affirmation selon laquelle le courant reste constant.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Param\u00e8tre d'\u00e9nergie de l'itin\u00e9raire<\/th><th class=\"has-text-align-right\" data-align=\"right\">Valeur illustrative<\/th><\/tr><\/thead><tbody><tr><td>Cycles complets de levage et de retour<\/td><td class=\"has-text-align-right\" data-align=\"right\">30<\/td><\/tr><tr><td>\u00c9nergie moyenne par cycle<\/td><td class=\"has-text-align-right\" data-align=\"right\">18 Wh<\/td><\/tr><tr><td>\u00c9nergie n\u00e9cessaire au fonctionnement du hayon \u00e9l\u00e9vateur<\/td><td class=\"has-text-align-right\" data-align=\"right\">540 Wh<\/td><\/tr><tr><td>Consommation du r\u00e9gulateur et en veille<\/td><td class=\"has-text-align-right\" data-align=\"right\">60 Wh<\/td><\/tr><tr><td>Besoin \u00e9nerg\u00e9tique total au niveau des bornes de la batterie<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Dur\u00e9e effective de recharge du v\u00e9hicule<\/td><td class=\"has-text-align-right\" data-align=\"right\">2 heures<\/td><\/tr><tr><td>Puissance de charge moyenne accept\u00e9e<\/td><td class=\"has-text-align-right\" data-align=\"right\">120 W<\/td><\/tr><tr><td>\u00c9nergie fournie aux bornes de la batterie<\/td><td class=\"has-text-align-right\" data-align=\"right\">240 Wh<\/td><\/tr><tr><td>D\u00e9ficit \u00e9nerg\u00e9tique quotidien terminal<\/td><td class=\"has-text-align-right\" data-align=\"right\">360 Wh<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Le v\u00e9hicule ne r\u00e9cup\u00e8re que 401 TP3T de l'\u00e9nergie consomm\u00e9e. Les 360 Wh restants doivent provenir du stockage existant de la batterie, en tenant compte des pertes internes de celle-ci. Cinq jours ouvr\u00e9s identiques sans recharge suppl\u00e9mentaire entra\u00eeneraient un d\u00e9ficit \u00e9nerg\u00e9tique cumul\u00e9 de 1 800 Wh.<\/p><p class=\"wp-block-paragraph\">L'autonomie \u00e9nerg\u00e9tique n'est pas synonyme de compatibilit\u00e9 avec le moteur. Une fiche technique du Kamada Power 12 V\/100 Ah indique un courant de d\u00e9charge continu maximal de 100 A et un courant de pointe de 150 A d'une dur\u00e9e inf\u00e9rieure \u00e0 3 millisecondes. Ces chiffres ne permettent pas de consid\u00e9rer qu'un seul bloc de batteries est capable de supporter un courant de 150 A pendant plusieurs secondes. V\u00e9rifiez le profil courant-dur\u00e9e du moteur, y compris le courant d'appel au d\u00e9marrage, les red\u00e9marrages en charge et les limites thermiques en cycles r\u00e9p\u00e9t\u00e9s, par rapport aux limites approuv\u00e9es du bloc-batterie \u00e0 la temp\u00e9rature pr\u00e9vue. V\u00e9rifiez la tension minimale aux bornes du moteur. Une chute de tension excessive au niveau du c\u00e2ble ou une d\u00e9connexion du syst\u00e8me de gestion de batterie (BMS) peut interrompre le fonctionnement m\u00eame s'il reste de l'\u00e9nergie stock\u00e9e. La coupure de protection \u00e0 8 V mentionn\u00e9e dans cette r\u00e9f\u00e9rence ne constitue pas, par d\u00e9faut, une tension de fonctionnement acceptable pour le moteur.<\/p><h2 class=\"wp-block-heading\">Le temps pass\u00e9 \u00e0 conduire en hiver permet-il de compenser l'\u00e9nergie consomm\u00e9e \u00e0 chaque arr\u00eat ?<\/h2><p class=\"wp-block-paragraph\">Un chargeur CC-CC d'une intensit\u00e9 nominale de 40 A ne fournit pas n\u00e9cessairement 40 A \u00e0 la batterie du hayon tout au long d'un trajet hivernal. Le courant de charge admissible d\u00e9pend de l'alimentation \u00e9lectrique du v\u00e9hicule, des caract\u00e9ristiques de sortie du chargeur, de la temp\u00e9rature et de l'\u00e9tat de charge (SOC) de la batterie, ainsi que des limites sp\u00e9cifi\u00e9es pour la batterie finie.<\/p><p class=\"wp-block-paragraph\">L'\u00e9nergie fournie au cours de chaque intervalle de conduite est la suivante :<\/p><p class=\"wp-block-paragraph\"><strong>\u00c9nergie de charge (Wh) = int\u00e9grale de Vcharge(t) \u00d7 Iaccepted(t) sur la dur\u00e9e \u00f7 3 600<\/strong><\/p><p class=\"wp-block-paragraph\">Utilisez le courant r\u00e9ellement absorb\u00e9 par la batterie, et non la valeur nominale maximale indiqu\u00e9e sur le chargeur. Lorsque des charges auxiliaires restent actives pendant la conduite, tenez-en compte s\u00e9par\u00e9ment ou utilisez syst\u00e9matiquement la puissance nette aux bornes de la batterie.<\/p><p class=\"wp-block-paragraph\">Prenons l'exemple d'une tension de charge hypoth\u00e9tique de 13,5 V et d'un intervalle de conduite de 15 minutes. \u00c0 10 A, la batterie re\u00e7oit 33,75 Wh. \u00c0 20 A, elle re\u00e7oit 67,5 Wh. \u00c0 40 A, elle re\u00e7oit 135 Wh. Ces valeurs supposent une tension et un courant constants, et ne tiennent pas compte des pertes internes li\u00e9es au stockage. Il ne s'agit pas de sp\u00e9cifications relatives au courant de charge d'une batterie Kamada Power.<\/p><p class=\"wp-block-paragraph\">\u00c0 titre de r\u00e9f\u00e9rence, la fiche technique 12 V\/100 Ah indique un courant de 10 A entre \u221220 \u00b0C et \u221210 \u00b0C et de 20 A entre \u221210 \u00b0C et 0 \u00b0C. Ces limites varient selon la r\u00e9vision. La r\u00e9f\u00e9rence d\u00e9crit une charge CC\/CV standard entre 0 et 45 \u00b0C ; il convient de v\u00e9rifier s\u00e9par\u00e9ment les limites de tension, de courant, de coupure et de temp\u00e9rature en dessous de z\u00e9ro, ainsi que le comportement du BMS. Un chargeur plus puissant ne peut pas outrepasser ces limites. De m\u00eame, la r\u00e9gulation courante du courant ne doit pas d\u00e9pendre des coupures de protection du BMS. Le <a href=\"https:\/\/www.purkeys.net\/wp-content\/uploads\/2018\/07\/Direct-01-Installation-Guide.pdf\" target=\"_blank\" rel=\"noopener\">Guide d'installation de Purkeys Direct<\/a> d\u00e9crit l'augmentation de la tension de charge par temps froid. Il convient donc de v\u00e9rifier qu'un profil de compensation de temp\u00e9rature existant pour les batteries au plomb-acide respecte les limites de tension et de courant homologu\u00e9es pour le bloc de batteries au sodium-ion ; la valeur maximale de r\u00e9f\u00e9rence de 15,6 V constitue un plafond, et non un point de consigne de charge universel.<\/p><p class=\"wp-block-paragraph\">Une batterie homologu\u00e9e pour une recharge \u00e0 des temp\u00e9ratures inf\u00e9rieures \u00e0 z\u00e9ro peut constituer une alternative aux syst\u00e8mes qui limitent la recharge en dessous de z\u00e9ro, \u00e0 condition que les exigences en mati\u00e8re de courant du moteur et de tension soient respect\u00e9es. La recherche sur les cellules ne suffit pas \u00e0 elle seule \u00e0 d\u00e9terminer les limites de recharge d'une batterie finie ni le rendement \u00e9nerg\u00e9tique en hiver.<\/p><p class=\"wp-block-paragraph\">C'est la temp\u00e9rature de la batterie, et non la temp\u00e9rature ambiante, qui d\u00e9termine la limite de charge applicable. Un bloc-batterie mont\u00e9 sur remorque peut rester froid une fois que le moteur a chauff\u00e9, ce qui limite la recharge lors de trajets courts.<\/p><p class=\"wp-block-paragraph\">Un intervalle de conduite de cinq minutes \u00e0 120 W ne fournit que 10 Wh. Si l'ouverture pr\u00e9c\u00e9dente du hayon a consomm\u00e9 18 Wh, un d\u00e9ficit \u00e9nerg\u00e9tique terminal suppl\u00e9mentaire de 8 Wh est report\u00e9, avant m\u00eame de tenir compte des pertes li\u00e9es au stockage. Des intervalles de conduite plus longs plus tard dans la journ\u00e9e pourraient permettre de combler ce d\u00e9ficit, mais ils ne peuvent pas compenser une livraison effectu\u00e9e avant ces intervalles.<\/p><h2 class=\"wp-block-heading\">\u00c0 quel endroit le parcours atteint-il son niveau de r\u00e9serve d'\u00e9nergie le plus bas ?<\/h2><p class=\"wp-block-paragraph\">Les itin\u00e9raires pr\u00e9sentant une consommation journali\u00e8re, une puissance de recharge et une r\u00e9serve finale identiques peuvent avoir des besoins \u00e9nerg\u00e9tiques minimaux diff\u00e9rents, car les \u00e9tapes de livraison et de recharge se d\u00e9roulent dans un ordre diff\u00e9rent.<\/p><p class=\"wp-block-paragraph\">Revenons \u00e0 l'itin\u00e9raire hypoth\u00e9tique consommant 600 Wh et recevant 240 Wh d'\u00e9nergie de recharge. Supposons qu'il commence avec 800 Wh d'\u00e9nergie stock\u00e9e disponible. Divisons la demande en trois blocs de 200 Wh chacun, y compris la consommation en veille allou\u00e9e, et l'apport de charge en deux blocs de 120 Wh. Pour cette comparaison simplifi\u00e9e, supposons que l'\u00e9nergie de charge soit enti\u00e8rement r\u00e9cup\u00e9rable, que la temp\u00e9rature soit constante et qu'aucun des deux blocs de charge ne se heurte \u00e0 une batterie pleine.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Phase d'exploitation<\/th><th class=\"has-text-align-right\" data-align=\"right\">Itin\u00e9raire A \u2014 Livraisons d\u00e9centralis\u00e9es<\/th><th class=\"has-text-align-right\" data-align=\"right\">Itin\u00e9raire B \u2014 Livraisons group\u00e9es<\/th><\/tr><\/thead><tbody><tr><td>D\u00e9part<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><\/tr><tr><td>Premier bloc de livraison<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Prochain \u00e9v\u00e9nement<\/td><td class=\"has-text-align-right\" data-align=\"right\">720 Wh (charge)<\/td><td class=\"has-text-align-right\" data-align=\"right\">400 Wh (\u00e0 la livraison)<\/td><\/tr><tr><td>Prochain \u00e9v\u00e9nement<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (en sortie)<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (charge)<\/td><\/tr><tr><td>Prochain bloc de recharge<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><\/tr><tr><td>Bloc de livraison final<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><\/tr><tr><td>\u00c9nergie restante minimale<\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>440 Wh<\/strong><\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>400 Wh<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png\" alt=\"\" class=\"wp-image-5338\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Les deux itin\u00e9raires aboutissent \u00e0 une consommation de 440 Wh. L'itin\u00e9raire B atteint toutefois son niveau de r\u00e9serve le plus bas avant la premi\u00e8re possibilit\u00e9 de recharge significative. En supposant une r\u00e9serve minimale de fonctionnement de 420 Wh, l'itin\u00e9raire A satisfait aux exigences \u00e9nerg\u00e9tiques, tandis que l'itin\u00e9raire B ne les satisfait pas.<\/p><p class=\"wp-block-paragraph\">Pour le mod\u00e8le simplifi\u00e9 \u00e0 temp\u00e9rature constante et sans pertes :<\/p><p class=\"wp-block-paragraph\"><strong>\u00c9nergie utilisable initiale requise \u2265 d\u00e9ficit \u00e9nerg\u00e9tique cumul\u00e9 maximal de l'itin\u00e9raire + r\u00e9serve d'exploitation requise.<\/strong><\/p><p class=\"wp-block-paragraph\">Dans les conditions pr\u00e9sent\u00e9es \u00e0 titre d'exemple, le d\u00e9ficit cumul\u00e9 maximal est de 360 Wh pour l'itin\u00e9raire A et de 400 Wh pour l'itin\u00e9raire B. Pour maintenir une r\u00e9serve de 420 Wh, il faut respectivement au moins 780 Wh et 820 Wh d'\u00e9nergie utilisable initiale. La r\u00e9serve de 420 Wh est donn\u00e9e \u00e0 titre indicatif et ne constitue pas une recommandation universelle. D\u00e9terminez la r\u00e9serve r\u00e9elle en fonction des cycles de levage restants indispensables, des livraisons impr\u00e9vues, du vieillissement et des al\u00e9as li\u00e9s aux basses temp\u00e9ratures ; v\u00e9rifiez la tension en charge de mani\u00e8re ind\u00e9pendante.<\/p><p class=\"wp-block-paragraph\">Dans la pratique, suivez l'\u00e9nergie disponible apr\u00e8s chaque cycle de distribution et de recharge. Limitez la recharge \u00e0 la marge de stockage disponible et tenez compte des pertes internes. R\u00e9\u00e9valuez l'\u00e9nergie disponible \u00e0 mesure que la temp\u00e9rature de fonctionnement \u00e9volue.<\/p><h2 class=\"wp-block-heading\">Dans quels cas la modernisation du syst\u00e8me de charge s'av\u00e8re-t-elle plus efficace que le remplacement de la batterie ?<\/h2><p class=\"wp-block-paragraph\">Pour les \u00e9quipementiers qui envisagent d'adopter une <a href=\"https:\/\/www.kmdpower.com\/fr\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Batterie sodium-ion 12V 100Ah<\/a>, les configurations en parall\u00e8le homologu\u00e9es par le fabricant offrent une solution potentielle pour augmenter la capacit\u00e9 de stockage. \u00c0 titre d\u2019exemple, sur la base d\u2019une conception nominale de 12 V, les configurations 1P, 2P, 3P et 4P correspondent respectivement \u00e0 100 Ah, 200 Ah, 300 Ah et 400 Ah, soit respectivement 1 200 Wh, 2 400 Wh, 3 600 Wh et 4 800 Wh. Il s\u2019agit de calculs nominaux, et non de l\u2019\u00e9nergie utile mesur\u00e9e. Le catalogue accessible via le lien mentionne un mod\u00e8le de 12,8 V ; la r\u00e9f\u00e9rence technique de 12 V utilis\u00e9e ici ne doit pas \u00eatre consid\u00e9r\u00e9e comme correspondant \u00e0 la m\u00eame version sans confirmation pr\u00e9alable. Veuillez obtenir la r\u00e9f\u00e9rence exacte (SKU) et les limites homologu\u00e9es avant la validation de la conception.<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png\" alt=\"\" class=\"wp-image-5336\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Si un seul bloc d'alimentation ne permet pas de fournir les 820 Wh requis pour le circuit concentr\u00e9, envisagez une configuration homologu\u00e9e plus puissante. D\u00e9terminez l'\u00e9nergie disponible \u00e0 la temp\u00e9rature pr\u00e9vue et \u00e0 la tension de fonctionnement de l'\u00e9quipement, et ne vous fiez pas uniquement \u00e0 la capacit\u00e9 nominale.<\/p><p class=\"wp-block-paragraph\">Si la recharge nocturne au d\u00e9p\u00f4t est suffisante, une batterie de plus grande capacit\u00e9 permet de faire face \u00e0 des livraisons concentr\u00e9es sans avoir recours \u00e0 un chargeur de v\u00e9hicule plus puissant.<\/p><p class=\"wp-block-paragraph\">Sans recharge nocturne, cette capacit\u00e9 suppl\u00e9mentaire ne fait que repousser le d\u00e9ficit quotidien r\u00e9current de 360 Wh.<\/p><p class=\"wp-block-paragraph\">Pour l\u2019itin\u00e9raire pr\u00e9sent\u00e9 en exemple, l\u2019\u00e9quilibrage d\u2019une demande quotidienne de 600 Wh au niveau du terminal sur deux heures de recharge effective n\u00e9cessite une puissance moyenne d\u2019au moins 300 W. \u00c0 une tension de recharge indicative de 13,5 V, cela correspond \u00e0 un courant admissible d\u2019environ 22,2 A, avant de tenir compte des pertes internes li\u00e9es au stockage. \u00c0 13,5 V, un bloc-batterie unique limit\u00e9 \u00e0 10 A ou 20 A ne re\u00e7oit que 270 Wh ou 540 Wh en deux heures, ce qui laisse un d\u00e9ficit de 330 Wh ou 60 Wh avant m\u00eame de prendre en compte les pertes. M\u00eame en tenant compte d\u2019une capacit\u00e9 de recharge en parall\u00e8le homologu\u00e9e, d\u2019intervalles de recharge plus longs ou d\u2019une recharge en d\u00e9p\u00f4t, un chargeur plus puissant ne peut \u00e0 lui seul surmonter les limites du bloc-batterie.<\/p><p class=\"wp-block-paragraph\">La d\u00e9cision d'achat est soumise \u00e0 quatre conditions :<\/p><ul class=\"wp-block-list\"><li><strong>P\u00e9nurie d'\u00e9nergie temporaire :<\/strong> Augmentez l'espace de stockage disponible ou d\u00e9placez une session de recharge disponible avant la p\u00e9riode de livraisons intense.<\/li>\n\n<li><strong>Sous-facturation r\u00e9currente :<\/strong> Am\u00e9liorer la gestion des r\u00e9approvisionnements compatibles gr\u00e2ce \u00e0 la recharge des v\u00e9hicules ou dans les d\u00e9p\u00f4ts.<\/li>\n\n<li><strong>Ces deux conditions :<\/strong> Comparez les besoins combin\u00e9s en stockage et en recharge \u00e0 l'aide du registre chronologique des itin\u00e9raires.<\/li>\n\n<li><strong>Incompatibilit\u00e9 entre le moteur et la tension :<\/strong> \u00c9vitez le remplacement direct et envisagez une plateforme OEM con\u00e7ue sp\u00e9cifiquement.<\/li><\/ul><p class=\"wp-block-paragraph\">Pour une charge de fonctionnement de 150 A, la r\u00e9partition id\u00e9ale entre les configurations 1P, 2P, 3P et 4P donne respectivement 150 A, 75 A, 50 A et 37,5 A par bloc. Avec la limite continue de r\u00e9f\u00e9rence de 100 A, la configuration 1P ne satisfait pas \u00e0 ce crit\u00e8re initial de courant soutenu ; les configurations 2P \u00e0 4P m\u00e9ritent une \u00e9valuation, mais ne b\u00e9n\u00e9ficient pas d\u2019une homologation automatique. Une configuration 2P pourrait faire supporter 150 A au pack restant si une branche venait \u00e0 se d\u00e9connecter. Le partage effectif du courant, les limites \u00e0 basse temp\u00e9rature, la protection des branches et le comportement de coupure de s\u00e9curit\u00e9 doivent \u00eatre d\u00e9finis. Si les configurations en parall\u00e8le approuv\u00e9es ne permettent pas de r\u00e9pondre aux exigences du moteur ou de la charge, il convient d\u2019envisager un bloc OEM haute puissance plut\u00f4t que de contourner la protection. Les mises \u00e0 niveau doivent respecter les exigences \u00e9lectriques et les conditions d\u2019homologation des constructeurs de v\u00e9hicules et de hayons \u00e9l\u00e9vateurs.<\/p><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png\" alt=\"\" class=\"wp-image-5337\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><h2 class=\"wp-block-heading\">FAQ<\/h2><h3 class=\"wp-block-heading\">Une batterie de 100 Ah peut-elle alimenter un hayon \u00e9l\u00e9vateur ?<\/h3><p class=\"wp-block-paragraph\">C'est possible. Une batterie au sodium-ion de 100 Ah finie doit r\u00e9pondre aux exigences du moteur hydraulique en mati\u00e8re de dur\u00e9e de courant, aux limites de tension en charge et au d\u00e9ficit \u00e9nerg\u00e9tique cumul\u00e9 maximal sur le parcours. Si un seul bloc s'av\u00e8re insuffisant, il est possible d'envisager des configurations en parall\u00e8le approuv\u00e9es par le constructeur ou une batterie OEM con\u00e7ue par un tiers. La capacit\u00e9 nominale ne garantit pas \u00e0 elle seule la compatibilit\u00e9 en vue d'un remplacement direct.<\/p><h3 class=\"wp-block-heading\">Est-ce que deux batteries permettront de rem\u00e9dier aux courtes autonomies ?<\/h3><p class=\"wp-block-paragraph\">Deux batteries parall\u00e8les homologu\u00e9es peuvent offrir une plus grande r\u00e9serve d'autonomie entre deux recharges. Elles n'augmentent pas n\u00e9cessairement la quantit\u00e9 d'\u00e9nergie r\u00e9cup\u00e9r\u00e9e lors de trajets courts. Si la consommation quotidienne continue de d\u00e9passer la recharge, une mise \u00e0 niveau du syst\u00e8me de recharge compatible ou une recharge suppl\u00e9mentaire au d\u00e9p\u00f4t reste n\u00e9cessaire.<\/p><h3 class=\"wp-block-heading\">Un chargeur CC\/CC doit-il disposer d'un profil sodium-ion ?<\/h3><p class=\"wp-block-paragraph\">Le chargeur doit r\u00e9pondre aux exigences de la batterie s\u00e9lectionn\u00e9e en mati\u00e8re de tension, de courant, de temp\u00e9rature et de fin de charge. Un profil d\u00e9di\u00e9 aux batteries sodium-ion peut \u00eatre appropri\u00e9, mais son nom ne garantit pas la compatibilit\u00e9. Les r\u00e9glages existants pour les batteries plomb-acide ou lithium-ion ne doivent \u00eatre utilis\u00e9s que si leur comportement r\u00e9el est valid\u00e9 pour la configuration sp\u00e9cifique de la batterie et de l'\u00e9quipement.<\/p><h2 class=\"wp-block-heading\">Conclusion<\/h2><p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/fr\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Batteries sodium-ion<\/a><\/strong> peuvent \u00eatre envisag\u00e9s pour les syst\u00e8mes de hayon \u00e9l\u00e9vateur de camions en hiver lorsque leur \u00e9nergie disponible, l'intensit\u00e9 admissible du moteur, la tension de fonctionnement et les limites de charge en fonction de la temp\u00e9rature correspondent au cycle de service de livraison. Le d\u00e9ficit cumulatif maximal sur l'itin\u00e9raire d\u00e9termine l'\u00e9nergie de d\u00e9marrage n\u00e9cessaire, tandis que le bilan de recharge quotidien d\u00e9termine si le syst\u00e8me peut assurer plusieurs jours de travail cons\u00e9cutifs. Pour les mod\u00e8les standard <strong><a href=\"https:\/\/www.kmdpower.com\/fr\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Batterie sodium-ion 12V 100Ah<\/a><\/strong>, les configurations en parall\u00e8le homologu\u00e9es ou les conceptions potentielles de batteries sur mesure pour hayons \u00e9l\u00e9vateurs, <a href=\"https:\/\/www.kmdpower.com\/fr\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Contactez Kamada Power<\/a> en nous communiquant votre itin\u00e9raire de livraison hivernal le plus long, le profil de courant du moteur hydraulique, les caract\u00e9ristiques de recharge du v\u00e9hicule et la plage de temp\u00e9rature pr\u00e9vue pour la batterie, afin que nous puissions discuter d'une architecture de batterie et de recharge adapt\u00e9e \u00e0 votre application.<\/p>","protected":false},"excerpt":{"rendered":"<p>Une batterie de hayon \u00e9l\u00e9vateur enti\u00e8rement charg\u00e9e ne garantit pas une autonomie suffisante pour la derni\u00e8re livraison. Les op\u00e9rations hydrauliques r\u00e9p\u00e9t\u00e9es, les trajets courts et les contraintes de recharge en hiver entra\u00eenent des d\u00e9ficits cumul\u00e9s. Pour les \u00e9quipementiers de hayons \u00e9l\u00e9vateurs et les pr\u00e9parateurs de v\u00e9hicules, l\u2019ad\u00e9quation des batteries au sodium d\u00e9pend de l\u2019\u00e9nergie disponible au point le plus exigeant de l\u2019itin\u00e9raire, d\u2019une puissance moteur suffisante et d\u2019une recharge avant la prochaine journ\u00e9e de travail\u2026<\/p>","protected":false},"author":1,"featured_media":1451,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/posts\/5335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/comments?post=5335"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/posts\/5335\/revisions"}],"predecessor-version":[{"id":5339,"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/posts\/5335\/revisions\/5339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/media\/1451"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/media?parent=5335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/categories?post=5335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/fr\/wp-json\/wp\/v2\/tags?post=5335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}