{"id":5167,"date":"2026-05-09T09:54:07","date_gmt":"2026-05-09T09:54:07","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5167"},"modified":"2026-05-09T09:54:09","modified_gmt":"2026-05-09T09:54:09","slug":"sodium-ion-vs-agm-batteries-is-your-ups-ready-for-the-sodium-revolution","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/fi\/news\/sodium-ion-vs-agm-batteries-is-your-ups-ready-for-the-sodium-revolution\/","title":{"rendered":"Sodium-ion vs. AGM Batteries: Is Your UPS Ready for the Sodium Revolution?"},"content":{"rendered":"<p>AGM (Absorbent Glass Mat) batteries have long been the industry standard for standby power, but their sensitivity to thermal stress and float-charging degradation is forcing a global shift. As Sodium-ion (Na-ion) emerges as a high-performance alternative, the real hurdle for procurement officers and industrial engineers in the US and Europe isn&#8217;t just cost\u2014it\u2019s technical integration. Can <strong><a href=\"https:\/\/www.kmdpower.com\/fi\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natriumioniakku<\/a><\/strong> truly replace AGM within your existing UPS infrastructure without compromising safety or reliability?<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-12v-100ah-sodium-ion-battery-main-image-002.jpg\" alt=\"\" class=\"wp-image-1181\"\/><\/figure><p class=\"has-text-align-center\"><strong><a href=\"https:\/\/www.kmdpower.com\/fi\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100Ah natriumioniakku<\/a><\/strong><\/p><h2 class=\"wp-block-heading\" id=\"sodium-ion-vs-agm-the-battle-for-the-future-of-standby-power\">Natriumioniakku vs. AGM: Taistelu valmiustehon tulevaisuudesta<\/h2><p>The energy landscape is shifting away from the &#8220;Lead-Acid Trap.&#8221; While Lithium-ion (LFP) has dominated the EV market, Sodium-ion is carving out a dynamic niche in stationary storage. Why? Because sodium is geologically abundant, immune to the price volatility of lithium, and\u2014from a chemical standpoint\u2014significantly more robust in high-demand industrial scenarios.<\/p><p>Kokemuksemme perusteella, jonka olemme saaneet ty\u00f6skennelless\u00e4mme datakeskusten ja tietoliikennepalvelujen tarjoajien kanssa, siirtyminen tiivistyy yleens\u00e4 \"luotettavuuden kolmikantaan\": Syklin kesto, l\u00e4mp\u00f6tilakest\u00e4vyys ja integroinnin helppous. Seuraavassa on tekninen vertailu, joka perustuu nykyiseen kaupalliseen natriumioniin (kerrostettu oksidi) ja korkealuokkaiseen teolliseen AGM:\u00e4\u00e4n:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Ominaisuus<\/th><th>AGM (lyijyhappo)<\/th><th>Natriumioni (Na-ioni)<\/th><th>Tiedonhankinta \/ asiantuntijan huomautus<\/th><\/tr><\/thead><tbody><tr><td><strong>Syklin k\u00e4ytt\u00f6ik\u00e4 (80% DoD)<\/strong><\/td><td>300 - 600 sykli\u00e4<\/td><td>4,000+ sykli\u00e4<\/td><td>Na-ionisyklin kesto riippuu katodityypist\u00e4 (kerroksellinen oksidi vs. preussinsininen).<\/td><\/tr><tr><td><strong>Latausl\u00e4mp\u00f6tila-alue<\/strong><\/td><td>0\u00b0C - 40\u00b0C (paras 25\u00b0C:ssa)<\/td><td>-10\u00b0C - 70\u00b0C<\/td><td>Na-ionit voivat latautua alhaisemmissa l\u00e4mp\u00f6tiloissa ilman litiumin pinnoitusriskej\u00e4.<\/td><\/tr><tr><td><strong>Purkausl\u00e4mp\u00f6tila-alue<\/strong><\/td><td>-15\u00b0C - 50\u00b0C<\/td><td>-40\u00b0C - 70\u00b0C<\/td><td>Na-ionit s\u00e4ilytt\u00e4v\u00e4t &gt;80% kapasiteetin pakkasessa.<\/td><\/tr><tr><td><strong>Lataustila<\/strong><\/td><td>3-vaiheinen kelluke<\/td><td>CC\/CV (vakiovirta\/j\u00e4nnite)<\/td><td>Na-ionit vaativat BMS-ohjatun terminoinnin.<\/td><\/tr><tr><td><strong>Itsepurkautuminen<\/strong><\/td><td>3% - 5% \/ kuukausi<\/td><td>&lt;1% - 2% \/ kuukausi<\/td><td>AGM:n \"hyllytt\u00e4minen\" johtaa peruuttamattomaan sulfatoitumiseen.<\/td><\/tr><tr><td><strong>Energiatiheys<\/strong><\/td><td>30 - 50 Wh\/kg<\/td><td>100 - 150 Wh\/kg<\/td><td>Kolmenkertainen painonpudotus alentaa merkitt\u00e4v\u00e4sti lattian kuormauskustannuksia.<\/td><\/tr><tr><td><strong>Turvallisuusstandardi<\/strong><\/td><td>UL 1989<\/td><td>UL 1973 \/ UL 9540A<\/td><td>Na-ion testataan \"levi\u00e4m\u00e4tt\u00f6myyden\" varalta tulipaloskenaarioissa.<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"wp-block-heading\" id=\"the-crucial-difference-in-charge-modes-cccv-vs-float\">Lataustapojen ratkaiseva ero: CCCV vs. Float<\/h2><p>Suurin yksitt\u00e4inen tekninen este AGM-akkujen korvaamiselle natriumioniakkuilla on se, ett\u00e4 n\u00e4iden kemikaalien s\u00e4hk\u00f6\u00e4 vastaanottava toiminta eroaa perustavanlaatuisesti toisistaan.<\/p><p><strong>AGM:n mukavuusalue: jatkuva tippuminen<\/strong>&nbsp;Lyijyakut vaativat&nbsp;<strong>Float-lataus<\/strong>. Ajattele sit\u00e4 jatkuvana, matalapaineisena energian \"tiputuksena\", joka pit\u00e4\u00e4 akun 100%:n tasolla. Koska AGM-akkujen sis\u00e4inen itsepurkautuminen on suurta, t\u00e4m\u00e4 tiputuslataus on pakollinen, jotta voidaan est\u00e4\u00e4&nbsp;<strong>sulfatointi<\/strong>-lyijysulfaattikiteiden muodostuminen, jotka kovettuvat ja tappavat akun.<\/p><p><strong>Natrium-ionin logiikka: Paineistettu s\u00e4ili\u00f6<\/strong>&nbsp;Natriumioni, kuten sen litiumioniserkkunsa, toimii litium-ionin&nbsp;<strong>CC\/CV (vakiovirta \/ vakioj\u00e4nnite)<\/strong>&nbsp;protokolla. Se ottaa nopeasti vastaan valtavan m\u00e4\u00e4r\u00e4n virtaa, saavuttaa j\u00e4nnitekaton, mink\u00e4 j\u00e4lkeen virta v\u00e4henee, kunnes akku on \"tyytyv\u00e4inen\".<\/p><p><strong>Ristiriita: korkea SOC-stressi<\/strong>&nbsp;T\u00e4ss\u00e4 kohtaa UPS:n ostajat joutuvat vaikeuksiin. Jos laitat natriumioniakun perinteiseen AGM-laturiin, laturi yritt\u00e4\u00e4 ty\u00f6nt\u00e4\u00e4 vakioj\u00e4nnitett\u00e4 loputtomiin. Hyvin suunniteltu akunhallintaj\u00e4rjestelm\u00e4 (BMS) suojaa kennoja,&nbsp;<strong>pitk\u00e4aikainen korkea lataustila (SOC) yhdistettyn\u00e4 jatkuvaan j\u00e4nnitepaineeseen.<\/strong>&nbsp;voi johtaa elektrolyytin hapettumiseen ja SEI-kerroksen (Solid Electrolyte Interphase) paksuuntumiseen. Toisin kuin AGM-akut, natriumioniakut eiv\u00e4t halua, ett\u00e4 niit\u00e4 \"t\u00f6nit\u00e4\u00e4n\" jatkuvasti, kun ne on t\u00e4ytetty; ne istuvat mieluummin toimettomina, kunnes niit\u00e4 kutsutaan toimintaan.<\/p><h2 class=\"wp-block-heading\" id=\"float-voltage-compatibility-the-drop-in-myth\">Kelluntaj\u00e4nnitteen yhteensopivuus: \"Drop-in\" myytti<\/h2><p>Konsultointity\u00f6ss\u00e4mme n\u00e4emme usein markkinointimateriaalia, jossa v\u00e4itet\u00e4\u00e4n \"100% Drop-in Replacement\". Insin\u00f6\u00f6rin\u00e4 kehotan sinua suhtautumaan t\u00e4h\u00e4n skeptisesti.<\/p><p><strong>J\u00e4nniteikkunan ongelma<\/strong>\u00a0Tavallinen 12V AGM-akku kelluu yleens\u00e4 v\u00e4lill\u00e4\u00a0<strong>13,5V ja 13,8V<\/strong>. <strong><a href=\"https:\/\/www.kmdpower.com\/fi\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natrium-ioniakut<\/a><\/strong> have a much wider and more linear voltage curve (typically 2.0V to 4.0V per cell). If your UPS firmware is hard-coded for AGM, it might &#8220;think&#8221; the Sodium-ion battery is empty when it is actually at 30% capacity, or it might never trigger the &#8220;Charge Complete&#8221; signal, causing the BMS to trip an Over-Voltage Protection (OVP) alarm.<\/p><p><strong>Viestinn\u00e4n kuilu: suljettu ja avoin silmukka<\/strong>&nbsp;Nykyaikaisessa natriumionihyllyss\u00e4 BMS:n on keskusteltava UPS:n kanssa.<\/p><ul class=\"wp-block-list\"><li><strong>Avoin silmukka:<\/strong>\u00a0UPS antaa virtaa vain j\u00e4nnitteen perusteella. (Riskialtis natriumionien osalta).<\/li>\n\n<li><strong>Suljettu silmukka:<\/strong>\u00a0UPS vastaanottaa tietoja\u00a0<strong>Modbus TCP\/IP, CANbus tai SNMP<\/strong>\u00a0BMS:st\u00e4. Akku kertoo UPS:lle: \"Olen t\u00e4ynn\u00e4, lopeta lataaminen.\"<\/li>\n\n<li><strong>Asiantuntijan n\u00e4kemys:<\/strong>\u00a0Jos olet hankinnoista vastaava virkamies, kysy aina:\u00a0<em>\"Tukeeko t\u00e4m\u00e4 akun BMS-j\u00e4rjestelm\u00e4 suljetun silmukan viestint\u00e4\u00e4 tietyn UPS-merkkini (esim. Vertiv, Eaton tai APC) kanssa?\"<\/em><\/li><\/ul><h2 class=\"wp-block-heading\" id=\"standby-self-discharge-and-the-0v-reality\">Itsepurkautuminen valmiustilassa ja 0V todellisuus<\/h2><p>Jos akku seisoo kauko-ohjatussa tietoliikennekaapissa kuusi kuukautta, toimiiko se edelleen?<\/p><p>AGM-akut ovat pahamaineisia \"hyllytt\u00e4misest\u00e4\". Jos niit\u00e4 ei pidet\u00e4 laturissa, ne menett\u00e4v\u00e4t tarpeeksi mehua ja alkavat sulfatoitua kuukausien kuluessa. Kaukana sijaitsevissa televiestinn\u00e4n tukiasemissa - erityisesti verkon ulkopuolisilla tai ep\u00e4vakaalla verkkoalueella - t\u00e4m\u00e4 on lyijyhappoakkujen kuolemantuomio.<\/p><p><strong>Natrium-ionin salainen ase: 0V Shipping<\/strong>&nbsp;Yksi natriumionien vaikuttavimmista teknisist\u00e4 eduista on kyky k\u00e4ytt\u00e4\u00e4&nbsp;<strong>Alumiiniset virran ker\u00e4\u00e4j\u00e4t<\/strong>&nbsp;sek\u00e4 anodilla ett\u00e4 katodilla. Litiumionissa kupariker\u00e4in liukenee matalilla j\u00e4nnitteill\u00e4. Natrium-ioni voi olla&nbsp;<strong>purkautuu 0,0 V:iin turvallista lentorahtia ja pitk\u00e4aikaista varastointia varten.<\/strong>&nbsp;vahingoittamatta kemiaa.<\/p><ul class=\"wp-block-list\"><li><strong>Korjaus insin\u00f6\u00f6reille:<\/strong>\u00a0Vaikka Na-ion voi olla\u00a0<em>tallennettu<\/em>\u00a00V:n j\u00e4nnitteell\u00e4, toimivat j\u00e4rjestelm\u00e4t vaativat edelleen\u00a0<strong>Matalan j\u00e4nnitteen katkaisu (~2.0V)<\/strong>. \u00c4l\u00e4 anna UPS:n tyhjent\u00e4\u00e4 akkua 0 V:iin kent\u00e4ll\u00e4, sill\u00e4 BMS vaatii v\u00e4himm\u00e4isj\u00e4nnitteen pysy\u00e4kseen virrallisena ja \"her\u00e4tt\u00e4\u00e4kseen\" j\u00e4rjestelm\u00e4n.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"safety-and-thermal-runaway-moving-beyond-the-fear\">Turvallisuus ja terminen karkaaminen: Liikkuminen pelon ohi<\/h2><p>Laitosten johtajille turvallisuus on \"elefantti huoneessa\". AGM-akut ovat suhteellisen turvallisia, mutta ne voivat kaasuttaa vety\u00e4 ylilatauksen aikana (mik\u00e4 johtaa \"termiseen karkaamiseen\").<\/p><p>Natriumioniakut ovat luonnostaan vakaampia kuin litium-NMC-akut. Oikosulun aikana syntyv\u00e4n suuremman sis\u00e4isen vastuksen ja elektrolyytin suuremman l\u00e4mp\u00f6stabiilisuuden ansiosta natriumioniakkujen palon levi\u00e4minen katastrofaalisesti on paljon ep\u00e4todenn\u00e4k\u00f6isemp\u00e4\u00e4.<\/p><ul class=\"wp-block-list\"><li><strong>UL 9540A -tekij\u00e4:<\/strong>\u00a0Kun hankit Yhdysvalloissa sijaitsevia datakeskuksia, etsi seuraavia seikkoja\u00a0<strong>UL 9540A -testin tulokset<\/strong>. T\u00e4ll\u00e4 testill\u00e4 m\u00e4\u00e4ritet\u00e4\u00e4n, levi\u00e4\u00e4k\u00f6 yhdess\u00e4 akkumoduulissa syttynyt tulipalo seuraavaan. Laadukkaat natriumioniyksik\u00f6t on suunniteltu niin, ett\u00e4 ne eiv\u00e4t p\u00e4\u00e4se levi\u00e4m\u00e4\u00e4n, mik\u00e4 tarkoittaa, ett\u00e4 vaikka yksi kenno vioittuisi, teline pysyy turvallisena. T\u00e4m\u00e4 alentaa merkitt\u00e4v\u00e4sti vakuutusmaksuja ja NFPA 855 -vaatimusten noudattamiseen liittyvi\u00e4 esteit\u00e4.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"suitability-for-ups-standby-applications\">Soveltuvuus UPS- ja valmiussovelluksiin<\/h2><p>Tarkastellaanpa \"Tilan ja tehon\" v\u00e4list\u00e4 kompromissia. Tihe\u00e4ss\u00e4 palvelinhuoneessa lattiapinta-ala on arvokas voimavara.<\/p><ol class=\"wp-block-list\"><li><strong>Lattian kuormitus ja paino:<\/strong>\u00a0Natriumioni on huomattavasti kevyempi kuin AGM. 100 kW:n UPS:n AGM-pankki voi painaa useita tonneja, mik\u00e4 edellytt\u00e4\u00e4 vahvistettua betonilattiaa. Natriumioni tarjoaa saman k\u00e4ytt\u00f6ajan.\u00a0<strong>kolmasosa painosta<\/strong>.<\/li>\n\n<li><strong>Dynaaminen latauksen hyv\u00e4ksyminen (DCA):<\/strong>\u00a0Natriumioni voi ottaa latauksen vastaan paljon nopeammin kuin AGM. S\u00e4hk\u00f6katkoksen j\u00e4lkeen AGM-akku saattaa tarvita 10-24 tuntia saavuttaakseen j\u00e4lleen 100%:n tason. Natriumioniakku saavuttaa usein 80% SOC-arvon alle tunnissa, mik\u00e4 tekee siit\u00e4 huomattavasti paremman kohteissa, joissa on usein \"mikrokatkoksia\" tai ep\u00e4vakaita verkkoja.<\/li>\n\n<li><strong>Omistamisen kokonaiskustannukset (TCO):<\/strong>\u00a0Siirtyminen CAPEX:st\u00e4 OPEX:iin. AGM-j\u00e4rjestelm\u00e4 saattaa maksaa $10 000 aluksi, mutta se on vaihdettava 3-4 vuoden v\u00e4lein. Natriumionij\u00e4rjestelm\u00e4 saattaa maksaa $15 000, mutta kest\u00e4\u00e4 8-10 vuotta. Kun otetaan huomioon\u00a0<strong>\"Truck Roll\" -kulut<\/strong>\u00a0(ty\u00f6voima, lyijyn h\u00e4vitt\u00e4minen ja asennus), natriumioni maksaa itsens\u00e4 yleens\u00e4 takaisin 5. vuoteen menness\u00e4.<\/li><\/ol><h2 class=\"wp-block-heading\" id=\"should-you-switch-today-\">Pit\u00e4isik\u00f6 sinun vaihtaa t\u00e4n\u00e4\u00e4n?<\/h2><p>Natrium-vallankumous ei ole pelkk\u00e4\u00e4 hypetyst\u00e4, vaan vastaus lyijyhapon teknisiin rajoituksiin ja litiumin kustannusrajoituksiin.<\/p><ul class=\"wp-block-list\"><li><strong>Pysy AGM:ss\u00e4, jos:<\/strong>\u00a0Sinulla on pieni, vanhaa tekniikkaa edustava UPS, jossa ei ole laiteohjelmiston s\u00e4\u00e4t\u00f6mahdollisuuksia, ymp\u00e4rist\u00f6si on tiukasti ilmastoitu ja sinulla on hyvin rajallinen budjetti.<\/li>\n\n<li><strong>Switch to Sodium-ion if:<\/strong>\u00a0Olet rakentamassa uutta datakeskusta, toimimassa korkean l\u00e4mp\u00f6tilan ymp\u00e4rist\u00f6iss\u00e4 (L\u00e4hi-It\u00e4, Etel\u00e4-USA, Afrikka) tai k\u00e4sittelem\u00e4ss\u00e4 usein esiintyvi\u00e4 s\u00e4hk\u00f6katkoksia, jotka \"tappaisivat\" AGM-akun.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"-conclusion-\"><strong>P\u00e4\u00e4telm\u00e4<\/strong><\/h2><p><strong><a href=\"https:\/\/www.kmdpower.com\/fi\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natrium-ioniakku<\/a><\/strong> on ylivoimainen valinta nykyaikaiseen varavoimak\u00e4ytt\u00f6\u00f6n, sill\u00e4 se tarjoaa poikkeuksellista l\u00e4mp\u00f6stabiilisuutta ja perinteist\u00e4 AGM-akkua pidemm\u00e4n k\u00e4ytt\u00f6i\u00e4n. Se ei kuitenkaan ole \"sokea\" plug-and-play-ratkaisu. Onnistuminen edellytt\u00e4\u00e4 j\u00e4rjestelm\u00e4tason l\u00e4hestymistapaa: UPS:n latausohjelmiston sovittaminen natriumionij\u00e4nnitek\u00e4yr\u00e4\u00e4n ja vankan BMS-viestinn\u00e4n varmistaminen. Siirtym\u00e4ll\u00e4 suunniteltuun natriumioniratkaisuun voit vaihtaa huoltoa vaativat akut luotettavaan, pitk\u00e4aikaiseen varavoimastrategiaan, joka alentaa TCO:ta ja parantaa laitoksen ESG-luokitusta. <strong><a href=\"https:\/\/www.kmdpower.com\/fi\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Ota yhteytt\u00e4 Kamada Poweriin<\/a><\/strong> our engineering team to audit your UPS compatibility for Sodium-ion today.<\/p><h2 class=\"wp-block-heading\" id=\"-faq-\"><strong>FAQ<\/strong><\/h2><h3 class=\"wp-block-heading\" id=\"-can-i-mix-agm-and-sodium-ion-batteries-in-the-same-string-or-rack-\"><strong>Voinko sekoittaa AGM- ja natriumioniakkuja samaan sarjaan tai telineeseen?<\/strong><\/h3><p>Ehdottomasti ei. Niiden sis\u00e4iset vastukset ja j\u00e4nnitek\u00e4yr\u00e4t eroavat toisistaan huomattavasti. Niiden sekoittaminen aiheuttaa akkujen \"taistelun\" toisiaan vastaan, mik\u00e4 johtaa tulipalovaaraan tai v\u00e4litt\u00f6m\u00e4\u00e4n j\u00e4rjestelm\u00e4vikaan.<\/p><h3 class=\"wp-block-heading\" id=\"-is-sodium-ion-non-flammable-\"><strong>Is Sodium-ion &#8220;non-flammable&#8221;?<\/strong><\/h3><p>No battery is inherently non-flammable, but Sodium-ion has a significantly higher thermal stability threshold than Lithium NMC. It is much less likely to catch fire under physical stress, making it the preferred choice for high-occupancy buildings.<\/p><h3 class=\"wp-block-heading\" id=\"-what-if-my-ups-doesn-t-have-a-specific-sodium-setting-\"><strong>What if my UPS doesn&#8217;t have a specific &#8220;Sodium&#8221; setting?<\/strong><\/h3><p><strong>A:<\/strong>&nbsp;Most modern UPS units have a &#8220;User Defined&#8221; or &#8220;Custom Lithium&#8221; setting. You can manually input the Bulk and Float voltages provided by the Sodium-ion manufacturer. If your UPS only has a fixed &#8220;Lead-Acid&#8221; switch, you must consult an integrator before upgrading.<\/p><h3 class=\"wp-block-heading\" id=\"-how-does-the-self-discharge-rate-affect-my-black-start-capability-\"><strong>Miten itsepurkautumisnopeus vaikuttaa \"Black Start\" -ominaisuuteeni?<\/strong><\/h3><p>Koska natriumioni menett\u00e4\u00e4 alle 1% kuukaudessa valmiustilassa (jos BMS:n lepovirta on alhainen), se varmistaa, ett\u00e4 \"Black Start\" -kapasiteetti s\u00e4ilyy jopa kuukausien verkon vakauden j\u00e4lkeen. AGM-akut voivat \"pehmenty\u00e4\" samassa ajassa, jos kelluva laturi ei toimi oikein.<\/p>","protected":false},"excerpt":{"rendered":"<p>AGM (Absorbent Glass Mat) batteries have long been the industry standard for standby power, but their sensitivity to thermal stress and float-charging degradation is forcing a global shift. As Sodium-ion (Na-ion) emerges as a high-performance alternative, the real hurdle for procurement officers and industrial engineers in the US and Europe isn&#8217;t just cost\u2014it\u2019s technical integration&#8230;.<\/p>","protected":false},"author":1,"featured_media":1181,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5167","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/posts\/5167","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/comments?post=5167"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/posts\/5167\/revisions"}],"predecessor-version":[{"id":5168,"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/posts\/5167\/revisions\/5168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/media?parent=5167"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/categories?post=5167"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/fi\/wp-json\/wp\/v2\/tags?post=5167"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}