{"id":5335,"date":"2026-11-25T05:36:02","date_gmt":"2026-11-25T05:36:02","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5335"},"modified":"2026-11-25T05:36:04","modified_gmt":"2026-11-25T05:36:04","slug":"can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/es\/news\/can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route\/","title":{"rendered":"\u00bfPuede una bater\u00eda de iones de sodio mantener en funcionamiento las plataformas elevadoras de los camiones durante toda una ruta de reparto invernal?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Una bater\u00eda de la puerta elevadora completamente cargada no garantiza que haya energ\u00eda suficiente para la \u00faltima entrega. Las operaciones hidr\u00e1ulicas repetidas, los trayectos cortos y las limitaciones de recarga en invierno provocan d\u00e9ficits acumulados. Para los fabricantes de equipos originales (OEM) de puertas elevadoras y los empresas de acondicionamiento de veh\u00edculos, <strong><a href=\"https:\/\/www.kmdpower.com\/es\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">bater\u00eda de sodio<\/a><\/strong> La idoneidad depende de la energ\u00eda disponible en el punto m\u00e1s dif\u00edcil del recorrido, de que el motor tenga potencia suficiente y de que se reponga la energ\u00eda antes de la siguiente jornada laboral.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Sodium-Battery-12V-100Ah-Bluetooth-Low-Temperature-Na-Ion-Battery-Supplier-Factory-Manufacturers-001.jpg\" alt=\"\" class=\"wp-image-1451\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/es\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00eda de iones de sodio Kamada Power 12v 100Ah<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">\u00bfPor qu\u00e9 las paradas repetidas provocan un d\u00e9ficit energ\u00e9tico en la puerta elevadora?<\/h2><p class=\"wp-block-paragraph\">La bater\u00eda de la rampa elevadora alimenta el sistema hidr\u00e1ulico en las paradas y puede recargarse durante el trayecto. Una <a href=\"https:\/\/purkeys.net\/case-study-how-purkeys-direct-helped-keep-under-charged-liftgates-off-the-road\/\" target=\"_blank\" rel=\"noreferrer noopener\">caso relacionado con la flota, seg\u00fan informa Purkeys<\/a> describe c\u00f3mo las bater\u00edas descargadas impiden que las plataformas se eleven, lo que obliga a recurrir al servicio de asistencia en carretera. No se trata de una prueba de campo con bater\u00edas de iones de sodio.<\/p><p class=\"wp-block-paragraph\">Un cami\u00f3n puede descargar varios pal\u00e9s y recorrer en solo unos minutos el trayecto hasta el siguiente cliente. Una bater\u00eda llena puede ocultar una carga insuficiente el primer d\u00eda si la recarga nocturna en el dep\u00f3sito no es suficiente.<\/p><p class=\"wp-block-paragraph\">El invierno afecta tanto al suministro como a la demanda de energ\u00eda. Las bater\u00edas fr\u00edas pueden tener menos energ\u00eda disponible y l\u00edmites de carga m\u00e1s bajos. El l\u00edquido hidr\u00e1ulico fr\u00edo puede afectar a la duraci\u00f3n del funcionamiento y a la demanda del motor, dependiendo del l\u00edquido, la bomba y el dise\u00f1o del equipo. Es mejor medir estos efectos en lugar de aplicar un factor de correcci\u00f3n universal para el invierno.<\/p><p class=\"wp-block-paragraph\">Los cables y las conexiones largos pueden reducir la tensi\u00f3n de carga. Un cargador CC-CC espec\u00edfico para el port\u00f3n trasero puede compensar esta p\u00e9rdida, pero su presencia no garantiza la compatibilidad con las bater\u00edas de iones de sodio.<\/p><h2 class=\"wp-block-heading\">\u00bfCu\u00e1nta energ\u00eda consume una ruta de reparto con carga completa?<\/h2><p class=\"wp-block-paragraph\">La potencia indicada en la placa de caracter\u00edsticas del motor no determina el consumo energ\u00e9tico diario. El peso de la carga, la altura de elevaci\u00f3n, la eficiencia hidr\u00e1ulica y la duraci\u00f3n del funcionamiento influyen en el consumo, al igual que el hecho de que el descenso se realice de forma motorizada o asistida por gravedad.<\/p><p class=\"wp-block-paragraph\">Mide la tensi\u00f3n y la corriente en los bornes de la bater\u00eda durante operaciones representativas de la puerta trasera elevadora. La energ\u00eda el\u00e9ctrica consumida por ciclo es:<\/p><p class=\"wp-block-paragraph\"><strong>Energ\u00eda del ciclo (Wh) = integral de V(t) \u00d7 I(t) a lo largo del tiempo \u00f7 3.600<\/strong><\/p><p class=\"wp-block-paragraph\">La tensi\u00f3n se mide en voltios, la corriente en amperios y el tiempo en segundos.<\/p><p class=\"wp-block-paragraph\">Registra por separado los ascensos con carga, los desplazamientos sin carga, los retornos y los tiempos de espera, incluidas las paradas especialmente exigentes. No cuentes dos veces los retornos si ya est\u00e1n incluidos en un ciclo completo.<\/p><p class=\"wp-block-paragraph\">La siguiente ruta hipot\u00e9tica ilustra el c\u00e1lculo. Para que se aprecie la escala, el <a href=\"https:\/\/www.maxonlift.com\/sites\/default\/files\/manuals\/2017-01\/operators-handbook-gpc-x1-ld-gpc-x1-ldf-20908422_2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Manual del usuario de MAXON GPC X1-LD\/LDF, p\u00e1gina 5<\/a> Indica 150 A a 12 V y recomienda una bater\u00eda de 88 Ah para su ejemplo de 600 kg de capacidad. A 12 V y 150 A, 36 segundos de funcionamiento motorizado equivalente consumen 18 Wh. Se trata de una ilustraci\u00f3n de orden de magnitud, no de un ciclo medido ni de una afirmaci\u00f3n de que la corriente se mantenga constante.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Par\u00e1metro de energ\u00eda de la ruta<\/th><th class=\"has-text-align-right\" data-align=\"right\">Valor ilustrativo<\/th><\/tr><\/thead><tbody><tr><td>Ciclos completos de elevaci\u00f3n y retorno<\/td><td class=\"has-text-align-right\" data-align=\"right\">30<\/td><\/tr><tr><td>Energ\u00eda media por ciclo<\/td><td class=\"has-text-align-right\" data-align=\"right\">18 Wh<\/td><\/tr><tr><td>Energ\u00eda necesaria para el funcionamiento de la puerta elevadora<\/td><td class=\"has-text-align-right\" data-align=\"right\">540 Wh<\/td><\/tr><tr><td>Consumo del controlador y en modo de espera<\/td><td class=\"has-text-align-right\" data-align=\"right\">60 Wh<\/td><\/tr><tr><td>Demanda total de energ\u00eda en los terminales de la bater\u00eda<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Tiempo efectivo de recarga del veh\u00edculo<\/td><td class=\"has-text-align-right\" data-align=\"right\">2 horas<\/td><\/tr><tr><td>Potencia media de carga admitida<\/td><td class=\"has-text-align-right\" data-align=\"right\">120 W<\/td><\/tr><tr><td>Energ\u00eda suministrada a los bornes de la bater\u00eda<\/td><td class=\"has-text-align-right\" data-align=\"right\">240 Wh<\/td><\/tr><tr><td>D\u00e9ficit energ\u00e9tico diario en la terminal<\/td><td class=\"has-text-align-right\" data-align=\"right\">360 Wh<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">El veh\u00edculo solo recupera 40% de la energ\u00eda consumida. Los 360 Wh restantes deben obtenerse del almacenamiento de la bater\u00eda existente, teniendo en cuenta adem\u00e1s las p\u00e9rdidas internas de la bater\u00eda. Cinco d\u00edas laborables id\u00e9nticos sin recarga adicional dar\u00edan lugar a un d\u00e9ficit energ\u00e9tico acumulado de 1.800 Wh.<\/p><p class=\"wp-block-paragraph\">La suficiencia energ\u00e9tica no equivale a la compatibilidad del motor. Una referencia t\u00e9cnica del Kamada Power 12 V\/100 Ah indica una descarga continua m\u00e1xima de 100 A y un pulso de 150 A con una duraci\u00f3n inferior a 3 milisegundos. Esas cifras no permiten que un solo paquete de bater\u00edas soporte una elevaci\u00f3n de 150 A durante varios segundos. Comprueba el perfil de corriente y duraci\u00f3n del motor \u2014incluida la corriente de arranque, los reinicios bajo carga y los l\u00edmites t\u00e9rmicos de ciclos repetidos\u2014 y comp\u00e1ralo con los l\u00edmites aprobados del paquete a la temperatura prevista. Verifica la tensi\u00f3n m\u00ednima en los terminales del motor. Una ca\u00edda excesiva de tensi\u00f3n en el cableado o una desconexi\u00f3n del sistema de gesti\u00f3n de la bater\u00eda (BMS) pueden interrumpir el funcionamiento, incluso cuando a\u00fan queda energ\u00eda almacenada. El corte de protecci\u00f3n de 8 V que se menciona en esa referencia no es, por defecto, una tensi\u00f3n de funcionamiento aceptable para el motor.<\/p><h2 class=\"wp-block-heading\">\u00bfPuede el tiempo de conducci\u00f3n en invierno compensar la energ\u00eda consumida en cada parada?<\/h2><p class=\"wp-block-paragraph\">Un cargador CC-CC con una potencia nominal de 40 A no suministra necesariamente 40 A a la bater\u00eda del port\u00f3n trasero durante todo un viaje en invierno. La corriente de carga admitida depende del suministro el\u00e9ctrico del veh\u00edculo, de las caracter\u00edsticas de salida del cargador, de la temperatura y del estado de carga (SOC) de la bater\u00eda, as\u00ed como de los l\u00edmites especificados para la bater\u00eda en su estado final.<\/p><p class=\"wp-block-paragraph\">La energ\u00eda suministrada durante cada intervalo de conducci\u00f3n es:<\/p><p class=\"wp-block-paragraph\"><strong>Energ\u00eda de carga (Wh) = integral de Vcharge(t) \u00d7 Iaccepted(t) a lo largo del tiempo \u00f7 3.600<\/strong><\/p><p class=\"wp-block-paragraph\">Utiliza la corriente que realmente admite la bater\u00eda, no la potencia m\u00e1xima indicada en la placa de caracter\u00edsticas del cargador. Cuando haya cargas auxiliares activas durante la conducci\u00f3n, tenlas en cuenta por separado o utiliza de forma sistem\u00e1tica la potencia neta en los bornes de la bater\u00eda.<\/p><p class=\"wp-block-paragraph\">Supongamos una tensi\u00f3n de carga hipot\u00e9tica de 13,5 V y un intervalo de conducci\u00f3n de 15 minutos. A 10 A, la bater\u00eda recibe 33,75 Wh. A 20 A, recibe 67,5 Wh. A 40 A, recibe 135 Wh. Estos valores suponen una tensi\u00f3n y una corriente constantes, y no tienen en cuenta las p\u00e9rdidas internas de almacenamiento. No se trata de especificaciones de corriente de carga para una bater\u00eda Kamada Power.<\/p><p class=\"wp-block-paragraph\">A modo de contexto, la referencia t\u00e9cnica de 12 V\/100 Ah indica 10 A entre \u221220 \u00b0C y \u221210 \u00b0C, y 20 A entre \u221210 \u00b0C y 0 \u00b0C. Estos l\u00edmites dependen de la revisi\u00f3n concreta. La referencia describe la carga CC\/CV est\u00e1ndar entre 0 y 45 \u00b0C; comprueba por separado los l\u00edmites de tensi\u00f3n, corriente, desconexi\u00f3n y temperatura por debajo de cero, as\u00ed como el comportamiento del BMS. Un cargador de mayor potencia no puede anular esos l\u00edmites. Tampoco debe la regulaci\u00f3n rutinaria de la corriente depender de las desconexiones de protecci\u00f3n del BMS. El <a href=\"https:\/\/www.purkeys.net\/wp-content\/uploads\/2018\/07\/Direct-01-Installation-Guide.pdf\" target=\"_blank\" rel=\"noopener\">Gu\u00eda de instalaci\u00f3n de Purkeys Direct<\/a> describe c\u00f3mo aumentar la tensi\u00f3n de carga en climas fr\u00edos. Por lo tanto, es necesario comprobar que el perfil de compensaci\u00f3n de temperatura existente para las bater\u00edas de plomo-\u00e1cido se ajuste a los l\u00edmites de tensi\u00f3n y corriente homologados para el paquete de iones de sodio; el valor m\u00e1ximo de referencia de 15,6 V es un l\u00edmite m\u00e1ximo, no un valor de referencia universal para la carga.<\/p><p class=\"wp-block-paragraph\">Una bater\u00eda homologada para la recarga a temperaturas bajo cero puede suponer una alternativa a los sistemas que restringen la recarga por debajo del punto de congelaci\u00f3n, siempre que se cumplan los requisitos de corriente y tensi\u00f3n del motor. La investigaci\u00f3n sobre las celdas por s\u00ed sola no permite establecer los l\u00edmites de recarga de la bater\u00eda final ni la recuperaci\u00f3n de energ\u00eda en invierno.<\/p><p class=\"wp-block-paragraph\">La temperatura de la bater\u00eda, y no la temperatura ambiente, es la que determina el l\u00edmite de carga aplicable. Un conjunto de bater\u00edas instalado en un remolque puede permanecer fr\u00edo una vez que el motor se ha calentado, lo que limita la recarga durante los trayectos cortos.<\/p><p class=\"wp-block-paragraph\">Un intervalo de conducci\u00f3n de cinco minutos a 120 W solo aporta 10 Wh. Si la operaci\u00f3n anterior de la puerta trasera consumi\u00f3 18 Wh, se acumula otro d\u00e9ficit de energ\u00eda terminal de 8 Wh, incluso antes de tener en cuenta las p\u00e9rdidas por almacenamiento. Los intervalos de conducci\u00f3n m\u00e1s largos que se produzcan m\u00e1s adelante durante el d\u00eda pueden recuperar ese d\u00e9ficit, pero no sirven de ayuda para una entrega que se realice antes de dichos intervalos.<\/p><h2 class=\"wp-block-heading\">\u00bfEn qu\u00e9 punto de la ruta se alcanza el nivel m\u00e1s bajo de reserva de energ\u00eda?<\/h2><p class=\"wp-block-paragraph\">Las rutas con el mismo consumo diario, la misma potencia de carga y la misma reserva final pueden tener requisitos m\u00ednimos de energ\u00eda diferentes, ya que las operaciones de entrega y recarga se producen en un orden distinto.<\/p><p class=\"wp-block-paragraph\">Volvamos a la ruta hipot\u00e9tica en la que se consumen 600 Wh y se reciben 240 Wh de energ\u00eda de recarga. Supongamos que se parte de 800 Wh de energ\u00eda almacenada disponible. Dividamos la demanda en tres bloques de suministro de 200 Wh, incluido el consumo en modo de espera asignado, y el suministro de carga en dos bloques de 120 Wh. Para esta comparaci\u00f3n simplificada, supongamos que la energ\u00eda de carga es totalmente recuperable, que la temperatura es constante y que ninguno de los bloques de carga se encuentra con la bater\u00eda llena.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Fase operativa<\/th><th class=\"has-text-align-right\" data-align=\"right\">Ruta A \u2014 Entregas distribuidas<\/th><th class=\"has-text-align-right\" data-align=\"right\">Ruta B \u2014 Entregas concentradas<\/th><\/tr><\/thead><tbody><tr><td>Salida<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><\/tr><tr><td>Primer bloque de entregas<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Pr\u00f3ximo evento<\/td><td class=\"has-text-align-right\" data-align=\"right\">720 Wh (carga)<\/td><td class=\"has-text-align-right\" data-align=\"right\">400 Wh (capacidad nominal)<\/td><\/tr><tr><td>Pr\u00f3ximo evento<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (potencia \u00fatil)<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (carga)<\/td><\/tr><tr><td>Siguiente bloque de recarga<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><\/tr><tr><td>Bloque de entrega final<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><\/tr><tr><td>Energ\u00eda m\u00ednima restante<\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>440 Wh<\/strong><\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>400 Wh<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png\" alt=\"\" class=\"wp-image-5338\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Ambas rutas terminan con 440 Wh. Sin embargo, la ruta B alcanza su reserva m\u00ednima antes de la primera oportunidad significativa de recarga. Suponiendo una reserva m\u00ednima de funcionamiento de 420 Wh, la ruta A cumple con los requisitos energ\u00e9ticos, mientras que la ruta B no los cumple.<\/p><p class=\"wp-block-paragraph\">Para el modelo simplificado de temperatura constante y sin p\u00e9rdidas:<\/p><p class=\"wp-block-paragraph\"><strong>Energ\u00eda \u00fatil inicial necesaria \u2265 d\u00e9ficit energ\u00e9tico acumulado m\u00e1ximo de la ruta + reserva operativa necesaria.<\/strong><\/p><p class=\"wp-block-paragraph\">En las condiciones ilustrativas, el d\u00e9ficit acumulado m\u00e1ximo es de 360 Wh para la ruta A y de 400 Wh para la ruta B. Para mantener una reserva de 420 Wh se requieren, como m\u00ednimo, 780 Wh y 820 Wh de energ\u00eda \u00fatil inicial, respectivamente. La reserva de 420 Wh es orientativa, no una recomendaci\u00f3n universal. Establezca la reserva real teniendo en cuenta los ciclos de elevaci\u00f3n restantes esenciales, las entregas imprevistas, el envejecimiento y la incertidumbre derivada de las bajas temperaturas; compruebe la tensi\u00f3n de carga de forma independiente.<\/p><p class=\"wp-block-paragraph\">En la pr\u00e1ctica, hay que realizar un seguimiento de la energ\u00eda disponible tras cada segmento de suministro y recarga. Limitar la recarga al margen de almacenamiento disponible y tener en cuenta las p\u00e9rdidas internas. Reevaluar la energ\u00eda disponible a medida que cambia la temperatura de funcionamiento.<\/p><h2 class=\"wp-block-heading\">\u00bfCu\u00e1ndo resulta m\u00e1s eficaz actualizar el sistema de carga que cambiar la bater\u00eda?<\/h2><p class=\"wp-block-paragraph\">Para los fabricantes de equipos originales que est\u00e9n evaluando un <a href=\"https:\/\/www.kmdpower.com\/es\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00eda de iones de sodio de 12 V y 100 Ah<\/a>, las configuraciones en paralelo aprobadas por el fabricante ofrecen una forma potencial de aumentar la capacidad de almacenamiento. Tomando como ejemplo un dise\u00f1o nominal de 12 V, 1P, 2P, 3P y 4P representan 100 Ah, 200 Ah, 300 Ah y 400 Ah, o 1.200 Wh, 2.400 Wh, 3.600 Wh y 4.800 Wh, respectivamente. Se trata de c\u00e1lculos nominales, no de energ\u00eda \u00fatil medida. El cat\u00e1logo enlazado incluye un modelo de 12,8 V; la referencia t\u00e9cnica de 12 V utilizada aqu\u00ed no debe considerarse como la misma revisi\u00f3n sin confirmaci\u00f3n previa. Obtenga el n\u00famero de referencia exacto (SKU) y los l\u00edmites aprobados antes de la aprobaci\u00f3n del dise\u00f1o.<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png\" alt=\"\" class=\"wp-image-5336\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Si una unidad no puede suministrar los 820 Wh necesarios para la ruta concentrada, eval\u00faa una configuraci\u00f3n homologada de mayor tama\u00f1o. Determina la energ\u00eda disponible a la temperatura prevista y a la tensi\u00f3n de funcionamiento del equipo, y no bas\u00e1ndote \u00fanicamente en la capacidad nominal.<\/p><p class=\"wp-block-paragraph\">Si se realiza una recarga nocturna suficiente en el dep\u00f3sito, un banco de bater\u00edas de mayor capacidad puede cubrir las entregas concentradas sin necesidad de un cargador de veh\u00edculos de mayor potencia.<\/p><p class=\"wp-block-paragraph\">Sin una recarga nocturna, la capacidad adicional solo retrasa el d\u00e9ficit diario recurrente de 360 Wh.<\/p><p class=\"wp-block-paragraph\">Para la ruta de ejemplo, equilibrar una demanda diaria de 600 Wh en la terminal a lo largo de dos horas de carga efectiva requiere una potencia media de al menos 300 W. Con una tensi\u00f3n de carga ilustrativa de 13,5 V, eso supone aproximadamente 22,2 A de corriente admitida, sin tener en cuenta las p\u00e9rdidas internas del sistema de almacenamiento. A 13,5 V, un solo paquete limitado a 10 A o 20 A recibe solo 270 Wh o 540 Wh en dos horas, lo que deja un d\u00e9ficit de 330 Wh o 60 Wh antes de las p\u00e9rdidas. Tenga en cuenta la capacidad de carga en paralelo homologada, los intervalos de carga m\u00e1s largos o la carga en el dep\u00f3sito; un cargador m\u00e1s potente por s\u00ed solo no puede superar los l\u00edmites del paquete de bater\u00edas.<\/p><p class=\"wp-block-paragraph\">La decisi\u00f3n de contrataci\u00f3n se rige por cuatro condiciones:<\/p><ul class=\"wp-block-list\"><li><strong>Escasez temporal de energ\u00eda:<\/strong> Aumenta el espacio de almacenamiento \u00fatil o adelanta una oportunidad de recarga disponible antes de que llegue el grupo de entregas m\u00e1s exigente.<\/li>\n\n<li><strong>Cobros insuficientes recurrentes:<\/strong> Mejorar la reposici\u00f3n compatible mediante la recarga en veh\u00edculos o en el dep\u00f3sito.<\/li>\n\n<li><strong>Ambas condiciones:<\/strong> Compara las necesidades combinadas de almacenamiento y recarga utilizando el registro cronol\u00f3gico de rutas.<\/li>\n\n<li><strong>Incompatibilidad del motor o de la tensi\u00f3n:<\/strong> Descarta la sustituci\u00f3n directa y plant\u00e9ate utilizar una plataforma OEM dise\u00f1ada espec\u00edficamente.<\/li><\/ul><p class=\"wp-block-paragraph\">Para una carga operativa de 150 A, el reparto ideal entre los bancos 1P, 2P, 3P y 4P da como resultado 150 A, 75 A, 50 A y 37,5 A por banco, respectivamente. Con el l\u00edmite continuo de referencia de 100 A, el banco 1P no supera esta prueba inicial de corriente sostenida; los bancos 2P a 4P merecen una evaluaci\u00f3n, pero no una aprobaci\u00f3n autom\u00e1tica. Un banco 2P podr\u00eda hacer que el paquete restante tuviera que soportar 150 A si se desconectara una rama. Deben establecerse el reparto real, los l\u00edmites a bajas temperaturas, la protecci\u00f3n de las ramas y el comportamiento de apagado seguro. Si las configuraciones en paralelo aprobadas no pueden cumplir los requisitos del motor o de la carga, eval\u00fae un paquete OEM de alta potencia en lugar de eludir la protecci\u00f3n. Las adaptaciones deben cumplir los requisitos el\u00e9ctricos y las condiciones de homologaci\u00f3n de los fabricantes de veh\u00edculos y de puertas elevadoras.<\/p><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png\" alt=\"\" class=\"wp-image-5337\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><h2 class=\"wp-block-heading\">PREGUNTAS FRECUENTES<\/h2><h3 class=\"wp-block-heading\">\u00bfPuede una bater\u00eda de 100 Ah accionar un port\u00f3n elevador?<\/h3><p class=\"wp-block-paragraph\">En principio, s\u00ed. Una bater\u00eda de iones de sodio de 100 Ah ya montada debe cumplir los requisitos de intensidad y duraci\u00f3n del motor hidr\u00e1ulico, los l\u00edmites de tensi\u00f3n bajo carga y el d\u00e9ficit energ\u00e9tico acumulado m\u00e1ximo de la ruta. Si un solo paquete resulta insuficiente, se pueden considerar configuraciones en paralelo aprobadas por el fabricante o una bater\u00eda OEM dise\u00f1ada de forma independiente. La capacidad nominal no garantiza la compatibilidad para una sustituci\u00f3n directa.<\/p><h3 class=\"wp-block-heading\">\u00bfServir\u00e1n dos bater\u00edas para solucionar los intervalos cortos de conducci\u00f3n?<\/h3><p class=\"wp-block-paragraph\">Dos bater\u00edas en paralelo homologadas pueden proporcionar una mayor reserva operativa entre cada recarga. No aumentan necesariamente la energ\u00eda recuperada durante los trayectos cortos. Si el consumo diario sigue superando la recarga, seguir\u00e1 siendo necesaria una mejora del sistema de recarga compatible o una recarga adicional en el dep\u00f3sito.<\/p><h3 class=\"wp-block-heading\">\u00bfEs necesario que un cargador CC\/CC cuente con un perfil de iones de sodio?<\/h3><p class=\"wp-block-paragraph\">El cargador debe cumplir los requisitos de tensi\u00f3n, corriente, temperatura y finalizaci\u00f3n de la carga de la bater\u00eda seleccionada. Puede que resulte adecuado un perfil espec\u00edfico para bater\u00edas de iones de sodio, pero el hecho de que lleve ese nombre no garantiza la compatibilidad. Los ajustes existentes para bater\u00edas de plomo-\u00e1cido o de iones de litio solo deben utilizarse si su comportamiento real est\u00e1 homologado para la configuraci\u00f3n espec\u00edfica de la bater\u00eda y el equipo.<\/p><h2 class=\"wp-block-heading\">Conclusi\u00f3n<\/h2><p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/es\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00edas de iones de sodio<\/a><\/strong> son una opci\u00f3n v\u00e1lida para los sistemas de puerta elevadora de camiones en invierno cuando su energ\u00eda \u00fatil, la capacidad de corriente del motor, la tensi\u00f3n de funcionamiento y los l\u00edmites de carga en funci\u00f3n de la temperatura se ajustan al ciclo de trabajo de reparto. El d\u00e9ficit acumulado m\u00e1ximo de la ruta determina la energ\u00eda de arranque necesaria, mientras que el saldo de recarga diario determina si el sistema puede mantener d\u00edas laborables consecutivos. Para los modelos est\u00e1ndar <strong><a href=\"https:\/\/www.kmdpower.com\/es\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00eda de iones de sodio de 12 V y 100 Ah<\/a><\/strong>, configuraciones en paralelo homologadas o posibles dise\u00f1os personalizados de bater\u00edas para puertas elevadoras, <a href=\"https:\/\/www.kmdpower.com\/es\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Ponte en contacto con Kamada Power<\/a> junto con tu ruta de reparto invernal m\u00e1s larga, el perfil de corriente del motor hidr\u00e1ulico, las especificaciones de recarga del veh\u00edculo y el rango de temperatura previsto de la bater\u00eda, para analizar una arquitectura de bater\u00eda y recarga espec\u00edfica para tu aplicaci\u00f3n.<\/p>","protected":false},"excerpt":{"rendered":"<p>Una bater\u00eda de la plataforma elevadora completamente cargada no garantiza que haya energ\u00eda suficiente para la \u00faltima entrega. Las operaciones hidr\u00e1ulicas repetidas, los trayectos cortos y las restricciones de recarga en invierno provocan d\u00e9ficits acumulados. Para los fabricantes de equipos originales (OEM) de plataformas elevadoras y los empresas de equipamiento de veh\u00edculos, la idoneidad de las bater\u00edas de sodio depende de la energ\u00eda utilizable en el punto m\u00e1s exigente de la ruta, de una potencia suficiente del motor y de la recarga antes de la siguiente jornada laboral\u2026<\/p>","protected":false},"author":1,"featured_media":1451,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/5335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/comments?post=5335"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/5335\/revisions"}],"predecessor-version":[{"id":5339,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/5335\/revisions\/5339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/media\/1451"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/media?parent=5335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/categories?post=5335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/tags?post=5335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}