{"id":5167,"date":"2026-05-09T09:54:07","date_gmt":"2026-05-09T09:54:07","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5167"},"modified":"2026-05-09T09:54:09","modified_gmt":"2026-05-09T09:54:09","slug":"sodium-ion-vs-agm-batteries-is-your-ups-ready-for-the-sodium-revolution","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/es\/news\/sodium-ion-vs-agm-batteries-is-your-ups-ready-for-the-sodium-revolution\/","title":{"rendered":"Sodium-ion vs. AGM Batteries: Is Your UPS Ready for the Sodium Revolution?"},"content":{"rendered":"<p>AGM (Absorbent Glass Mat) batteries have long been the industry standard for standby power, but their sensitivity to thermal stress and float-charging degradation is forcing a global shift. As Sodium-ion (Na-ion) emerges as a high-performance alternative, the real hurdle for procurement officers and industrial engineers in the US and Europe isn&#8217;t just cost\u2014it\u2019s technical integration. Can <strong><a href=\"https:\/\/www.kmdpower.com\/es\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00eda de iones de sodio<\/a><\/strong> truly replace AGM within your existing UPS infrastructure without compromising safety or reliability?<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-12v-100ah-sodium-ion-battery-main-image-002.jpg\" alt=\"\" class=\"wp-image-1181\"\/><\/figure><p class=\"has-text-align-center\"><strong><a href=\"https:\/\/www.kmdpower.com\/es\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00eda de iones de sodio Kamada Power 12v 100Ah<\/a><\/strong><\/p><h2 class=\"wp-block-heading\" id=\"sodium-ion-vs-agm-the-battle-for-the-future-of-standby-power\">Bater\u00eda de iones de sodio frente a AGM: la batalla por el futuro de la energ\u00eda de reserva<\/h2><p>The energy landscape is shifting away from the &#8220;Lead-Acid Trap.&#8221; While Lithium-ion (LFP) has dominated the EV market, Sodium-ion is carving out a dynamic niche in stationary storage. Why? Because sodium is geologically abundant, immune to the price volatility of lithium, and\u2014from a chemical standpoint\u2014significantly more robust in high-demand industrial scenarios.<\/p><p>Por nuestra experiencia trabajando con centros de datos y proveedores de telecomunicaciones, la transici\u00f3n suele reducirse a la \"Tr\u00edada de la Fiabilidad\": Ciclo de vida, resistencia a la temperatura y facilidad de integraci\u00f3n. He aqu\u00ed una comparaci\u00f3n t\u00e9cnica basada en las actuales bater\u00edas de iones de sodio (\u00f3xido en capas) de calidad comercial frente a las AGM industriales de primera calidad:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Caracter\u00edstica<\/th><th>AGM (plomo-\u00e1cido)<\/th><th>Sodio-i\u00f3n (Na-i\u00f3n)<\/th><th>Obtenci\u00f3n de informaci\u00f3n \/ Nota de experto<\/th><\/tr><\/thead><tbody><tr><td><strong>Ciclo de vida (80% DoD)<\/strong><\/td><td>300 - 600 ciclos<\/td><td>4.000+ ciclos<\/td><td>La vida \u00fatil del ciclo de Na-ion depende del tipo de c\u00e1todo (\u00f3xido estratificado frente a azul de Prusia).<\/td><\/tr><tr><td><strong>Rango de temperatura de carga<\/strong><\/td><td>0\u00b0C a 40\u00b0C (mejor a 25\u00b0C)<\/td><td>-10\u00b0C a 70\u00b0C<\/td><td>El Na-ion puede cargar a temperaturas m\u00e1s bajas sin riesgos de recubrimiento de litio.<\/td><\/tr><tr><td><strong>Rango de temperatura de descarga<\/strong><\/td><td>-15\u00b0C a 50\u00b0C<\/td><td>-40\u00b0C a 70\u00b0C<\/td><td>El Na-ion mantiene una capacidad &gt;80% a temperaturas de congelaci\u00f3n.<\/td><\/tr><tr><td><strong>Modo de carga<\/strong><\/td><td>Flotador de 3 etapas<\/td><td>CC\/CV (Corriente\/Voltaje constantes)<\/td><td>El Na-ion requiere una terminaci\u00f3n controlada por el BMS.<\/td><\/tr><tr><td><strong>Autodescarga<\/strong><\/td><td>3% - 5% \/ mes<\/td><td>&lt;1% - 2% \/ mes<\/td><td>El \"envejecimiento\" de los AGM provoca una sulfataci\u00f3n irreversible.<\/td><\/tr><tr><td><strong>Densidad energ\u00e9tica<\/strong><\/td><td>30 - 50 Wh\/kg<\/td><td>100 - 150 Wh\/kg<\/td><td>La reducci\u00f3n del peso en 3 veces disminuye significativamente los costes de carga del suelo.<\/td><\/tr><tr><td><strong>Norma de seguridad<\/strong><\/td><td>UL 1989<\/td><td>UL 1973 \/ UL 9540A<\/td><td>El Na-ion se somete a pruebas de \"no propagaci\u00f3n\" en escenarios de incendio.<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"wp-block-heading\" id=\"the-crucial-difference-in-charge-modes-cccv-vs-float\">La diferencia crucial en los modos de carga: CCCV vs. Flotaci\u00f3n<\/h2><p>El mayor obst\u00e1culo t\u00e9cnico a la hora de sustituir las bater\u00edas AGM por las de iones de sodio es la diferencia fundamental en la forma en que estas qu\u00edmicas aceptan la electricidad.<\/p><p><strong>La zona de confort de AGM: el goteo constante<\/strong>&nbsp;Las bater\u00edas de plomo-\u00e1cido requieren&nbsp;<strong>Carga del flotador<\/strong>. Piense en ello como un \"goteo\" constante de energ\u00eda a baja presi\u00f3n que mantiene la bater\u00eda a 100%. Dado que las bater\u00edas AGM tienen una elevada autodescarga interna, esta carga lenta es obligatoria para evitar que se descarguen.&nbsp;<strong>sulfataci\u00f3n<\/strong>-la acumulaci\u00f3n de cristales de sulfato de plomo que se endurecen y matan la bater\u00eda.<\/p><p><strong>La l\u00f3gica del ion sodio: El tanque presurizado<\/strong>&nbsp;El i\u00f3n sodio, como su primo el i\u00f3n litio, funciona con un&nbsp;<strong>CC\/CV (Corriente constante \/ Tensi\u00f3n constante)<\/strong>&nbsp;protocolo. Acepta una gran cantidad de corriente r\u00e1pidamente, alcanza un techo de tensi\u00f3n y luego la corriente disminuye hasta que la bater\u00eda est\u00e1 \"satisfecha\".<\/p><p><strong>El conflicto: el alto estr\u00e9s del SOC<\/strong>&nbsp;Aqu\u00ed es donde la cosa se complica para los compradores de SAIs. Si coloca una bater\u00eda de iones de sodio en un cargador de flotaci\u00f3n AGM tradicional, el cargador intentar\u00e1 mantener un voltaje constante indefinidamente. Mientras que un Sistema de Gesti\u00f3n de Bater\u00edas (BMS) bien dise\u00f1ado proteger\u00e1 las celdas,&nbsp;<strong>Estado de carga (SOC) elevado y prolongado combinado con un estr\u00e9s de tensi\u00f3n constante.<\/strong>&nbsp;puede provocar la oxidaci\u00f3n del electrolito y el engrosamiento de la capa SEI (Solid Electrolyte Interphase). A diferencia de las AGM, las de iones de sodio no quieren que se las \"pinche\" constantemente una vez llenas; prefieren permanecer inactivas hasta que se las llame a actuar.<\/p><h2 class=\"wp-block-heading\" id=\"float-voltage-compatibility-the-drop-in-myth\">Compatibilidad de la tensi\u00f3n de flotaci\u00f3n: El mito del \"drop-in<\/h2><p>En nuestro trabajo de consultor\u00eda, a menudo vemos material de marketing que afirma \"100% Drop-in Replacement\". Como ingeniero, le aconsejo que se muestre esc\u00e9ptico al respecto.<\/p><p><strong>El problema de la ventana de tensi\u00f3n<\/strong>\u00a0Una bater\u00eda AGM est\u00e1ndar de 12 V suele flotar entre\u00a0<strong>13,5 V y 13,8 V<\/strong>. <strong><a href=\"https:\/\/www.kmdpower.com\/es\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00edas de iones de sodio<\/a><\/strong> have a much wider and more linear voltage curve (typically 2.0V to 4.0V per cell). If your UPS firmware is hard-coded for AGM, it might &#8220;think&#8221; the Sodium-ion battery is empty when it is actually at 30% capacity, or it might never trigger the &#8220;Charge Complete&#8221; signal, causing the BMS to trip an Over-Voltage Protection (OVP) alarm.<\/p><p><strong>La brecha de comunicaci\u00f3n: bucle cerrado frente a bucle abierto<\/strong>&nbsp;En un bastidor moderno de iones de sodio, el BMS debe hablar con el SAI.<\/p><ul class=\"wp-block-list\"><li><strong>Bucle abierto:<\/strong>\u00a0El SAI s\u00f3lo suministra energ\u00eda en funci\u00f3n de la tensi\u00f3n. (Riesgo para los iones de sodio).<\/li>\n\n<li><strong>Bucle cerrado:<\/strong>\u00a0El SAI recibe datos a trav\u00e9s de\u00a0<strong>Modbus TCP\/IP, CANbus o SNMP<\/strong>\u00a0del BMS. La bater\u00eda le dice al SAI: \"Estoy llena, deja de cargar\".<\/li>\n\n<li><strong>La opini\u00f3n de los expertos:<\/strong>\u00a0Si es usted funcionario de contrataci\u00f3n p\u00fablica, pregunte siempre:\u00a0<em>\"\u00bfEste BMS de bater\u00eda admite la comunicaci\u00f3n en bucle cerrado con mi marca espec\u00edfica de SAI (por ejemplo, Vertiv, Eaton o APC)?\".<\/em><\/li><\/ul><h2 class=\"wp-block-heading\" id=\"standby-self-discharge-and-the-0v-reality\">Autodescarga en modo de espera y la realidad de los 0 V<\/h2><p>Si una bater\u00eda permanece seis meses en un armario de telecomunicaciones, \u00bfseguir\u00e1 funcionando?<\/p><p>Las bater\u00edas AGM son conocidas por su \"envejecimiento\". Si no se mantienen en un cargador, pierden suficiente energ\u00eda como para empezar a sulfatarse en cuesti\u00f3n de meses. En estaciones base de telecomunicaciones remotas -especialmente en zonas sin red o con una red inestable- esto es una sentencia de muerte para las bater\u00edas de plomo-\u00e1cido.<\/p><p><strong>El arma secreta de los iones de sodio: el env\u00edo a 0 V<\/strong>&nbsp;Una de las ventajas t\u00e9cnicas m\u00e1s impresionantes del ion sodio es la posibilidad de utilizar&nbsp;<strong>Colectores de corriente de aluminio<\/strong>&nbsp;tanto en el \u00e1nodo como en el c\u00e1todo. En el i\u00f3n-litio, el colector de cobre se disuelve a bajas tensiones. El i\u00f3n sodio puede ser&nbsp;<strong>descarga a 0,0 V para un transporte a\u00e9reo seguro y un almacenamiento a largo plazo<\/strong>&nbsp;sin da\u00f1ar la qu\u00edmica.<\/p><ul class=\"wp-block-list\"><li><strong>Correcci\u00f3n para ingenieros:<\/strong>\u00a0Mientras que el Na-ion puede ser\u00a0<em>almacenado<\/em>\u00a0a 0V, los sistemas operativos siguen necesitando un\u00a0<strong>Corte por baja tensi\u00f3n (~2,0 V)<\/strong>. No permita que su SAI descargue una bater\u00eda a 0V en el campo, ya que el BMS requiere un voltaje m\u00ednimo para permanecer alimentado y \"despertar\" el sistema.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"safety-and-thermal-runaway-moving-beyond-the-fear\">Seguridad y fuga t\u00e9rmica: M\u00e1s all\u00e1 del miedo<\/h2><p>Para los gestores de instalaciones, la seguridad es el \"Elefante en la habitaci\u00f3n\". Las bater\u00edas AGM son relativamente seguras, pero pueden desprender hidr\u00f3geno durante la sobrecarga (lo que provoca una hinchaz\u00f3n por \"fuga t\u00e9rmica\").<\/p><p>El sodio-i\u00f3n es intr\u00ednsecamente m\u00e1s estable que las bater\u00edas de litio NMC. Debido a su mayor resistencia interna durante un cortocircuito y a la mayor estabilidad t\u00e9rmica del electrolito, es mucho menos probable que el sodio-i\u00f3n sufra una propagaci\u00f3n catastr\u00f3fica del fuego.<\/p><ul class=\"wp-block-list\"><li><strong>El factor UL 9540A:<\/strong>\u00a0Al contratar centros de datos con sede en EE.UU., busque\u00a0<strong>Resultados de la prueba UL 9540A<\/strong>. Esta prueba determina si un incendio en un m\u00f3dulo de bater\u00eda se propagar\u00e1 al siguiente. Las unidades de iones de sodio de alta calidad est\u00e1n dise\u00f1adas para \"no propagarse\", lo que significa que incluso si falla una c\u00e9lula, el bastidor permanece seguro. Esto reduce significativamente las primas de seguros y los obst\u00e1culos de cumplimiento de la norma NFPA 855.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"suitability-for-ups-standby-applications\">Idoneidad para aplicaciones UPS y de reserva<\/h2><p>Analicemos la relaci\u00f3n entre espacio y potencia. En una sala de servidores de alta densidad, el espacio es un bien preciado.<\/p><ol class=\"wp-block-list\"><li><strong>Carga y peso en el suelo:<\/strong>\u00a0Las bater\u00edas de iones de sodio son mucho m\u00e1s ligeras que las AGM. Un banco de AGM para un SAI de 100 kW puede pesar varias toneladas y requerir un suelo de hormig\u00f3n armado. El sodio-i\u00f3n proporciona el mismo tiempo de funcionamiento a\u00a0<strong>un tercio del peso<\/strong>.<\/li>\n\n<li><strong>Aceptaci\u00f3n din\u00e1mica de la carga (DCA):<\/strong>\u00a0Las de iones de sodio pueden aceptar una carga mucho m\u00e1s r\u00e1pido que las AGM. Tras un apag\u00f3n, una bater\u00eda AGM puede tardar entre 10 y 24 horas en volver a alcanzar 100%. Las de iones de sodio pueden alcanzar los 80% SOC en menos de una hora, lo que las hace muy superiores en lugares con frecuentes \"microcortes\" o redes inestables.<\/li>\n\n<li><strong>Coste total de propiedad (TCO):<\/strong>\u00a0Pasar del CAPEX al OPEX. Un sistema AGM puede costar $10.000 por adelantado, pero hay que sustituirlo cada 3-4 a\u00f1os. Un sistema de iones de sodio puede costar $15.000, pero dura entre 8 y 10 a\u00f1os. Si tenemos en cuenta\u00a0<strong>\"Costes de \"Truck Roll<\/strong>\u00a0(mano de obra, eliminaci\u00f3n del plomo e instalaci\u00f3n), Sodium-ion suele amortizarse al quinto a\u00f1o.<\/li><\/ol><h2 class=\"wp-block-heading\" id=\"should-you-switch-today-\">\u00bfDeber\u00eda cambiar hoy?<\/h2><p>La \"revoluci\u00f3n del sodio\" no es s\u00f3lo una exageraci\u00f3n: es una respuesta a las limitaciones t\u00e9cnicas del plomo y el \u00e1cido y a las limitaciones de coste del litio.<\/p><ul class=\"wp-block-list\"><li><strong>Qu\u00e9dese con AGM si:<\/strong>\u00a0Tiene un SAI peque\u00f1o y antiguo sin posibilidad de ajuste de firmware, su entorno est\u00e1 estrictamente climatizado y dispone de un presupuesto inicial muy limitado.<\/li>\n\n<li><strong>Switch to Sodium-ion if:<\/strong>\u00a0Est\u00e1 construyendo un nuevo centro de datos, trabaja en entornos con altas temperaturas (Oriente Medio, sur de EE.UU., \u00c1frica) o tiene que hacer frente a frecuentes bajadas de tensi\u00f3n que acabar\u00edan con el ciclo de una bater\u00eda AGM.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"-conclusion-\"><strong>Conclusi\u00f3n<\/strong><\/h2><p><strong><a href=\"https:\/\/www.kmdpower.com\/es\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00eda de iones de sodio<\/a><\/strong> es la mejor opci\u00f3n para la energ\u00eda de reserva moderna, ya que ofrece una estabilidad t\u00e9rmica excepcional y un ciclo de vida que eclipsa a las AGM tradicionales. Sin embargo, no es una soluci\u00f3n plug-and-play \"a ciegas\". El \u00e9xito requiere un enfoque a nivel de sistema: adaptar el firmware de carga del SAI a la curva de tensi\u00f3n del Sodium-ion y garantizar una s\u00f3lida comunicaci\u00f3n BMS. Al cambiar a una soluci\u00f3n de iones de sodio de ingenier\u00eda, cambia los cambios de bater\u00edas de alto mantenimiento por una estrategia de respaldo fiable y a largo plazo que reduce el coste total de propiedad y mejora la calificaci\u00f3n ESG de sus instalaciones. <strong><a href=\"https:\/\/www.kmdpower.com\/es\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Contacto Kamada Power<\/a><\/strong> our engineering team to audit your UPS compatibility for Sodium-ion today.<\/p><h2 class=\"wp-block-heading\" id=\"-faq-\"><strong>PREGUNTAS FRECUENTES<\/strong><\/h2><h3 class=\"wp-block-heading\" id=\"-can-i-mix-agm-and-sodium-ion-batteries-in-the-same-string-or-rack-\"><strong>\u00bfPuedo mezclar bater\u00edas AGM y de iones de sodio en la misma cadena o bastidor?<\/strong><\/h3><p>Por supuesto que no. Tienen resistencias internas y curvas de tensi\u00f3n muy diferentes. Mezclarlas har\u00e1 que las pilas \"luchen\" entre s\u00ed, con el consiguiente riesgo de incendio o fallo inmediato del sistema.<\/p><h3 class=\"wp-block-heading\" id=\"-is-sodium-ion-non-flammable-\"><strong>Is Sodium-ion &#8220;non-flammable&#8221;?<\/strong><\/h3><p>No battery is inherently non-flammable, but Sodium-ion has a significantly higher thermal stability threshold than Lithium NMC. It is much less likely to catch fire under physical stress, making it the preferred choice for high-occupancy buildings.<\/p><h3 class=\"wp-block-heading\" id=\"-what-if-my-ups-doesn-t-have-a-specific-sodium-setting-\"><strong>What if my UPS doesn&#8217;t have a specific &#8220;Sodium&#8221; setting?<\/strong><\/h3><p><strong>A:<\/strong>&nbsp;Most modern UPS units have a &#8220;User Defined&#8221; or &#8220;Custom Lithium&#8221; setting. You can manually input the Bulk and Float voltages provided by the Sodium-ion manufacturer. If your UPS only has a fixed &#8220;Lead-Acid&#8221; switch, you must consult an integrator before upgrading.<\/p><h3 class=\"wp-block-heading\" id=\"-how-does-the-self-discharge-rate-affect-my-black-start-capability-\"><strong>\u00bfC\u00f3mo afecta la tasa de autodescarga a mi capacidad de \"arranque en negro\"?<\/strong><\/h3><p>Dado que las bater\u00edas de iones de sodio pierden menos de 1% al mes en modo de espera (si la corriente de reposo del BMS es baja), garantizan la conservaci\u00f3n de la capacidad de arranque en negro incluso despu\u00e9s de meses de estabilidad de la red. Las bater\u00edas AGM pueden \"fallar suavemente\" en el mismo periodo de tiempo si el cargador de flotaci\u00f3n funciona mal.<\/p>","protected":false},"excerpt":{"rendered":"<p>AGM (Absorbent Glass Mat) batteries have long been the industry standard for standby power, but their sensitivity to thermal stress and float-charging degradation is forcing a global shift. As Sodium-ion (Na-ion) emerges as a high-performance alternative, the real hurdle for procurement officers and industrial engineers in the US and Europe isn&#8217;t just cost\u2014it\u2019s technical integration&#8230;.<\/p>","protected":false},"author":1,"featured_media":1181,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5167","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/5167","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/comments?post=5167"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/5167\/revisions"}],"predecessor-version":[{"id":5168,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/5167\/revisions\/5168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/media?parent=5167"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/categories?post=5167"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/tags?post=5167"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}