{"id":4381,"date":"2025-04-28T10:18:11","date_gmt":"2025-04-28T10:18:11","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=4381"},"modified":"2025-04-28T10:18:13","modified_gmt":"2025-04-28T10:18:13","slug":"what-does-the-rack-unit-u-mean-in-server-racks","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/es\/news\/what-does-the-rack-unit-u-mean-in-server-racks\/","title":{"rendered":"\u00bfQu\u00e9 significa la unidad de bastidor U en los bastidores para servidores?"},"content":{"rendered":"<p>Entrar en una sala de servidores o incluso mirar un rack puede parecer confuso al principio. \u00bfC\u00f3mo encaja todo ese equipo? Ah\u00ed es donde el <strong>Unidad de estanter\u00eda<\/strong>o \"<strong>U<\/strong>. Es la medida est\u00e1ndar del espacio vertical en los racks de servidores. Entender la \"U\" es clave para cualquiera que maneje hardware de servidores: te dice exactamente cu\u00e1nto espacio vertical necesitan los equipos. Simplifica el montaje de todo. Qu\u00e9date conmigo, y vamos a aclarar lo que es una unidad de rack, c\u00f3mo se puede calcular el tama\u00f1o de su propio equipo, ejecutar a trav\u00e9s de las conversiones \u00fatiles, y ver c\u00f3mo funcionan los agujeros de rack.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/WechatIMG3014.jpg\" alt=\"\" class=\"wp-image-2549\"\/><\/figure><p class=\"has-text-align-center\"><strong><a href=\"https:\/\/www.kmdpower.com\/es\/solar-batteries\/\" target=\"_blank\" rel=\"noreferrer noopener\">Bater\u00eda para rack de servidor Kamada Power 1U 2U 3U 4U 5U<\/a><\/strong><\/p><h2 class=\"wp-block-heading\" id=\"what-does-the-rack-unit-u-mean-\">\u00bfQu\u00e9 significa la unidad de estanter\u00eda U?<\/h2><p>A <strong>Unidad de bastidor (U o RU)<\/strong> es b\u00e1sicamente c\u00f3mo medimos la altura de los equipos cuando se construyen para ir en un <strong>bastidor de servidor<\/strong>.<\/p><ul class=\"wp-block-list\"><li><strong>Es una altura fija:<\/strong> Escucha, una Unidad de Rack (<strong>1U<\/strong>) es <em>siempre<\/em> <strong>1,75 pulgadas de alto<\/strong>. Es la medida b\u00e1sica en la que se basa todo lo dem\u00e1s en el mundo de los bastidores. (S\u00ed, tambi\u00e9n es <strong>44,45 mm<\/strong> en m\u00e9trica).<\/li>\n\n<li><strong>Ya es oficial:<\/strong> No se trata de una talla que alguien haya decidido al azar. Esta medida est\u00e1ndar procede del <strong>Alianza de Industrias Electr\u00f3nicas (norma EIA-310)<\/strong>. Esto es fundamental porque es lo que garantiza que los equipos fabricados por distintas empresas encajen f\u00edsicamente en los bastidores est\u00e1ndar fabricados con las mismas especificaciones.<\/li>\n\n<li><strong>Talla Engranaje:<\/strong> Los equipos (servidores, conmutadores de red, bater\u00edas, etc.) tienen alturas que son m\u00faltiplos exactos de este tama\u00f1o U (1U, 2U, 4U, etc.). Est\u00e1n dise\u00f1ados para apilarse perfectamente.<\/li>\n\n<li><strong>Talla Racks:<\/strong> \u00bfY las propias estanter\u00edas? Tambi\u00e9n est\u00e1n dimensionadas en funci\u00f3n del n\u00famero total de U que pueden albergar verticalmente (como esas grandes <strong>Racks 42U<\/strong> que se ve en todas partes).<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"how-to-calculate-rack-units\">C\u00f3mo calcular las unidades de estanter\u00eda<\/h2><p>\u00bfTienes un dispositivo y necesitas su tama\u00f1o U? Utilice este m\u00e9todo r\u00e1pido. Ayuda a planificar el espacio en el rack sin hacer conjeturas.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Paso<\/th><th>Qu\u00e9 hacer<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><strong>Mide la altura:<\/strong> Calcula la altura vertical total del aparato. No incluyas protuberancias ni asas adicionales.<\/td><\/tr><tr><td>2<\/td><td><strong>Usa pulgadas:<\/strong> Convierte esa altura a pulgadas si es necesario (1 pulgada = 25,4 mm).<\/td><\/tr><tr><td>3<\/td><td><strong>Divide:<\/strong> Divida la altura en pulgadas por 1,75 (pulgadas por U).<\/td><\/tr><\/tbody><\/table><\/figure><p><strong>F\u00f3rmula:<\/strong><\/p><p>U = Altura del dispositivo (en pulgadas) \u00f7 1,75<\/p><p><strong>Por ejemplo:<\/strong><\/p><ul class=\"wp-block-list\"><li>Un servidor mide <strong>5,25 pulgadas<\/strong> alto.<\/li>\n\n<li>C\u00e1lculo: 5.25 \u00f7 1.75 = <strong>3U<\/strong>.<\/li>\n\n<li>Es un <strong>Servidor 3U<\/strong>.<\/li><\/ul><p>Este sencillo c\u00e1lculo ayuda a confirmar el tama\u00f1o del dispositivo para colocarlo correctamente en el rack.<\/p><h2 class=\"wp-block-heading\" id=\"server-rack-unit-conversion\">Conversi\u00f3n de unidades de bastidor de servidor<\/h2><p>\u00bfNecesita cambiar entre U, pulgadas, mil\u00edmetros o cent\u00edmetros? Estas conversiones son \u00fatiles.<\/p><p>Los factores b\u00e1sicos son: 1U = <strong>1,75 pulgadas<\/strong> = <strong>44,45 mm<\/strong> = <strong>4,445 cm<\/strong>.<\/p><p>Estas sencillas conversiones ahorran tiempo a la hora de comprobar especificaciones o dimensiones.<\/p><h3 class=\"wp-block-heading\" id=\"rack-unit-to-inches\">Rack U a pulgadas<\/h3><p>Una unidad de rack es siempre <strong>1,75 pulgadas<\/strong>.<\/p><p><strong>F\u00f3rmula:<\/strong><\/p><p>1U = 1,75 pulgadas<\/p><p><strong>Por ejemplo:<\/strong><\/p><ul class=\"wp-block-list\"><li>A <strong>3U<\/strong> dispositivo = 3 \u00d7 1,75 = <strong>5,25 pulgadas<\/strong> alto.<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"1u-to-inches\">1U a pulgadas<\/h3><p>Exactamente <strong>1U<\/strong> altura es <strong>1,75 pulgadas<\/strong>.<\/p><p><strong>F\u00f3rmula:<\/strong><\/p><p>1U = 1,75 pulgadas<\/p><p>Esta es la conversi\u00f3n fundamental que debes conocer.<\/p><h3 class=\"wp-block-heading\" id=\"rack-unit-to-millimeters\">Unidad de rack a mil\u00edmetros<\/h3><p>Para convertir U a mil\u00edmetros, multiplique el n\u00famero de U por <strong>44,45 mm<\/strong>.<\/p><p><strong>F\u00f3rmula:<\/strong><\/p><p>Altura (mm) = U \u00d7 44,45<\/p><p><strong>Por ejemplo:<\/strong><\/p><ul class=\"wp-block-list\"><li>A <strong>4U<\/strong> dispositivo = 4 \u00d7 44,45 = <strong>177,8 mm<\/strong> alto.<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"rack-unit-to-centimeters\">Unidad de rack a cent\u00edmetros<\/h3><p>Para convertir U en cent\u00edmetros, multiplique el n\u00famero de U por <strong>4,445 cm<\/strong>.<\/p><p><strong>F\u00f3rmula:<\/strong><\/p><p>Altura (cm) = U \u00d7 4,445<\/p><p><strong>Por ejemplo:<\/strong><\/p><ul class=\"wp-block-list\"><li>A <strong>5U<\/strong> dispositivo = 5 \u00d7 4.445 = <strong>22,225 cm<\/strong> alto.<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"-rack-unit-conversion-formula-\"><strong>F\u00f3rmula de conversi\u00f3n de unidades de rack<\/strong><\/h3><p>Estas son las principales conversiones:<\/p><p>1U = 1,75 pulgadas = 44,45 mil\u00edmetros = 4,445 cent\u00edmetros<\/p><h3 class=\"wp-block-heading\" id=\"rack-u-size-chart\">Tabla de tallas de Rack U<\/h3><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Unidad Rack\uff08u\uff09<\/th><th>Altura RU\uff08mm\uff09<\/th><th>RU Altura\uff08inch\uff09<\/th><th>RU Altura\uff08cm\uff09<\/th><\/tr><\/thead><tbody><tr><td>1U<\/td><td>44,45 mm<\/td><td>1.75&#8243;<\/td><td>4,445 cm<\/td><\/tr><tr><td>2U<\/td><td>88,90 mm<\/td><td>3.50&#8243;<\/td><td>8.890cm<\/td><\/tr><tr><td>3U<\/td><td>133,35 mm<\/td><td>5.25&#8243;<\/td><td>13,335 cm<\/td><\/tr><tr><td>4U<\/td><td>177,80 mm<\/td><td>7.00&#8243;<\/td><td>17,780 cm<\/td><\/tr><tr><td>5U<\/td><td>222,25 mm<\/td><td>8.75&#8243;<\/td><td>22,225 cm<\/td><\/tr><tr><td>6U<\/td><td>266,70 mm<\/td><td>10.50&#8243;<\/td><td>26,670 cm<\/td><\/tr><tr><td>7U<\/td><td>311,15 mm<\/td><td>12.25&#8243;<\/td><td>31,115 cm<\/td><\/tr><tr><td>8U<\/td><td>355,60 mm<\/td><td>14.00&#8243;<\/td><td>35.560cm<\/td><\/tr><tr><td>9U<\/td><td>400,05 mm<\/td><td>15.75&#8243;<\/td><td>40,005 cm<\/td><\/tr><tr><td>10U<\/td><td>444,50 mm<\/td><td>17.50&#8243;<\/td><td>44,450 cm<\/td><\/tr><tr><td>11U<\/td><td>488,95 mm<\/td><td>19.25&#8243;<\/td><td>48,895 cm<\/td><\/tr><tr><td>12U<\/td><td>533,40 mm<\/td><td>21.00&#8243;<\/td><td>53,340 cm<\/td><\/tr><tr><td>13U<\/td><td>577,85 mm<\/td><td>22.75&#8243;<\/td><td>57,785 cm<\/td><\/tr><tr><td>14U<\/td><td>622,30 mm<\/td><td>24.50&#8243;<\/td><td>62,230 cm<\/td><\/tr><tr><td>15U<\/td><td>666,75 mm<\/td><td>26.25&#8243;<\/td><td>66,675 cm<\/td><\/tr><tr><td>16U<\/td><td>711,20 mm<\/td><td>28.00&#8243;<\/td><td>71,120 cm<\/td><\/tr><tr><td>17U<\/td><td>755,65 mm<\/td><td>29.75&#8243;<\/td><td>75,565 cm<\/td><\/tr><tr><td>18U<\/td><td>800,10 mm<\/td><td>31.50&#8243;<\/td><td>80.010cm<\/td><\/tr><tr><td>19U<\/td><td>844,55 mm<\/td><td>33.25&#8243;<\/td><td>84,455 cm<\/td><\/tr><tr><td>20U<\/td><td>889,00 mm<\/td><td>35.00&#8243;<\/td><td>88,900 cm<\/td><\/tr><tr><td>21U<\/td><td>933,45 mm<\/td><td>36.75&#8243;<\/td><td>93,345 cm<\/td><\/tr><tr><td>22U<\/td><td>977,90 mm<\/td><td>38.50&#8243;<\/td><td>97,790 cm<\/td><\/tr><tr><td>23U<\/td><td>1022,35 mm<\/td><td>40.25&#8243;<\/td><td>102,235 cm<\/td><\/tr><tr><td>24U<\/td><td>1066,80 mm<\/td><td>42.00&#8243;<\/td><td>106,680 cm<\/td><\/tr><tr><td>25U<\/td><td>1111,25 mm<\/td><td>43.75&#8243;<\/td><td>111,125 cm<\/td><\/tr><tr><td>26U<\/td><td>1155,70 mm<\/td><td>45.50&#8243;<\/td><td>115,570 cm<\/td><\/tr><tr><td>27U<\/td><td>1200,15 mm<\/td><td>47.25&#8243;<\/td><td>120,015 cm<\/td><\/tr><tr><td>28U<\/td><td>1244,60 mm<\/td><td>49.00&#8243;<\/td><td>124,460 cm<\/td><\/tr><tr><td>29U<\/td><td>1289,05 mm<\/td><td>50.75&#8243;<\/td><td>128,905 cm<\/td><\/tr><tr><td>30U<\/td><td>1333,50 mm<\/td><td>52.50&#8243;<\/td><td>133,350 cm<\/td><\/tr><tr><td>31U<\/td><td>1377,95 mm<\/td><td>54.25&#8243;<\/td><td>137,795 cm<\/td><\/tr><tr><td>32U<\/td><td>1422,40 mm<\/td><td>56.00&#8243;<\/td><td>142,240 cm<\/td><\/tr><tr><td>33U<\/td><td>1466,85 mm<\/td><td>57.75&#8243;<\/td><td>146,685 cm<\/td><\/tr><tr><td>34U<\/td><td>1511,30 mm<\/td><td>59.50&#8243;<\/td><td>151,130 cm<\/td><\/tr><tr><td>35U<\/td><td>1555,75 mm<\/td><td>61.25&#8243;<\/td><td>155,575 cm<\/td><\/tr><tr><td>36U<\/td><td>1600,20 mm<\/td><td>63.00&#8243;<\/td><td>160.020cm<\/td><\/tr><tr><td>37U<\/td><td>1644,65 mm<\/td><td>64.75&#8243;<\/td><td>164,465 cm<\/td><\/tr><tr><td>38U<\/td><td>1689.10mm<\/td><td>66.50&#8243;<\/td><td>168,910 cm<\/td><\/tr><tr><td>39U<\/td><td>1733,55 mm<\/td><td>68.25&#8243;<\/td><td>173,355 cm<\/td><\/tr><tr><td>40U<\/td><td>1778.00mm<\/td><td>70.00&#8243;<\/td><td>177,800 cm<\/td><\/tr><tr><td>41U<\/td><td>1822,45 mm<\/td><td>71.75&#8243;<\/td><td>182,245 cm<\/td><\/tr><tr><td>42U<\/td><td>1866,90 mm<\/td><td>73.50&#8243;<\/td><td>186,690 cm<\/td><\/tr><tr><td>43U<\/td><td>1911,35 mm<\/td><td>75.25&#8243;<\/td><td>191,135 cm<\/td><\/tr><tr><td>44U<\/td><td>1955,80 mm<\/td><td>77.00&#8243;<\/td><td>195,580 cm<\/td><\/tr><tr><td>45U<\/td><td>2000,25 mm<\/td><td>78.75&#8243;<\/td><td>200.025cm<\/td><\/tr><tr><td>46U<\/td><td>2044.70mm<\/td><td>80.50&#8243;<\/td><td>204,470 cm<\/td><\/tr><tr><td>47U<\/td><td>2089.15mm<\/td><td>82.25&#8243;<\/td><td>208,915 cm<\/td><\/tr><tr><td>48U<\/td><td>2133,60 mm<\/td><td>84.00&#8243;<\/td><td>213,360 cm<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"wp-block-heading\" id=\"rack-hole-and-rack-unit-relationship\">Relaci\u00f3n entre el orificio de la estanter\u00eda y la unidad de estanter\u00eda<\/h2><p>F\u00edjate bien en los ra\u00edles verticales del interior de cualquier <strong>bastidor de servidor<\/strong>y ver\u00e1s un mont\u00f3n de agujeros que suben y bajan. \u00a1Estos no son al azar! Estos <strong>orificios de bastidor<\/strong> son exactamente donde atornillas tu equipo, tanto si usas <strong>tornillos o tuercas enjauladas<\/strong>. Y aqu\u00ed est\u00e1 la parte buena: se alinean perfectamente con el sistema de unidades Rack del que hemos estado hablando. Entender su patr\u00f3n hace que trabajar con bastidores sea mucho m\u00e1s claro.<\/p><h3 class=\"wp-block-heading\" id=\"what-is-a-rack-unit-u-\">\u00bfQu\u00e9 es una unidad de estanter\u00eda (U)?<\/h3><p>A modo de resumen r\u00e1pido: Piensa en un <strong>Unidad de rack (U)<\/strong> como la forma est\u00e1ndar de medir la altura vertical de los equipos que van en un rack de servidores. Un <strong>1U<\/strong> espacio es igual a <strong>1,75 pulgadas (unos 44,45 mm)<\/strong>.<\/p><h3 class=\"wp-block-heading\" id=\"what-is-a-rack-hole-\">\u00bfQu\u00e9 es un agujero de cremallera?<\/h3><p>Por lo tanto, estos <strong>orificios de bastidor<\/strong> son los puntos espec\u00edficos perforados en los ra\u00edles del rack donde se realizan las conexiones para montar los equipos. Pero no est\u00e1n repartidos al azar. La clave es que vienen en <strong>grupos<\/strong> a lo largo del ra\u00edl, y estos grupos est\u00e1n espaciados para coincidir exactamente con los tama\u00f1os de U est\u00e1ndar. Uno de estos grupos de agujeros marca la altura de <strong>una U<\/strong>.<\/p><h3 class=\"wp-block-heading\" id=\"how-do-rack-holes-relate-to-rack-units-\">\u00bfQu\u00e9 relaci\u00f3n hay entre los orificios y las unidades de estanter\u00eda?<\/h3><ul class=\"wp-block-list\"><li>Para <strong>1U<\/strong> de equipos, hay <strong>tres agujeros<\/strong> en el estante.<\/li>\n\n<li>Los agujeros est\u00e1n espaciados de forma coherente:<ul class=\"wp-block-list\"><li><strong>Brecha entre la cima y la parte media<\/strong>: <strong>0,625 pulgadas<\/strong> (15,875 mm)<\/li>\n\n<li><strong>Brecha entre el medio y el fondo<\/strong>: <strong>0,625 pulgadas<\/strong><\/li>\n\n<li><strong>Brecha de abajo a arriba<\/strong>: <strong>0,5 pulgadas<\/strong> (12,7 mm)<\/li><\/ul><\/li><\/ul><h2 class=\"wp-block-heading\" id=\"common-rack-unit-applications\">Aplicaciones comunes de las unidades de rack<\/h2><p>Los distintos equipos suelen venir en determinados tama\u00f1os U en funci\u00f3n de necesidades como el espacio o la refrigeraci\u00f3n. Conocerlas te ayudar\u00e1 a planificar tu rack.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Tama\u00f1o U<\/th><th>Equipo t\u00edpico que ver\u00e1<\/th><\/tr><\/thead><tbody><tr><td><strong>1U<\/strong><\/td><td>Conmutadores de red, cortafuegos, peque\u00f1os servidores, paneles de conexi\u00f3n. Ideal para ahorrar espacio vertical.<\/td><\/tr><tr><td><strong>2U<\/strong><\/td><td>Servidores est\u00e1ndar, servidores de almacenamiento, bater\u00edas de SAI comunes. Necesita m\u00e1s espacio interno.<\/td><\/tr><tr><td><strong>3U<\/strong><\/td><td>Equipos antiguos o especializados, como bibliotecas de cintas y almacenamiento denso. Menos habitual en servidores nuevos.<\/td><\/tr><tr><td><strong>4U<\/strong><\/td><td>Grandes matrices de almacenamiento, servidores GPU, grandes SAI. Necesitan una altura considerable.<\/td><\/tr><tr><td><strong>5U+<\/strong><\/td><td>Sistemas muy grandes, bater\u00edas modulares, equipos a medida.<\/td><\/tr><\/tbody><\/table><\/figure><p>Esto te da una idea r\u00e1pida del espacio que suelen necesitar los distintos tipos de equipos inform\u00e1ticos.<\/p><h2 class=\"wp-block-heading\" id=\"conclusion\">Conclusi\u00f3n<\/h2><p>Conocer las Unidades de Rack (U) es clave para gestionar los racks de servidores y <strong><a href=\"https:\/\/www.kmdpower.com\/es\/solar-batteries\/\" target=\"_blank\" rel=\"noreferrer noopener\">bater\u00eda de bastidor de servidor<\/a><\/strong>. Comprender la U significa que puede elegir el equipo que encaje, planificar bien su espacio y mantenerlo todo organizado. Simplifica la instalaci\u00f3n y ayuda a maximizar el espacio vertical de forma eficiente.<\/p><p><strong><a href=\"https:\/\/www.kmdpower.com\/es\/\" target=\"_blank\" rel=\"noreferrer noopener\">energ\u00eda kamada<\/a><\/strong> como Profesional <strong><a href=\"https:\/\/www.kmdpower.com\/es\/solar-batteries\/\">bater\u00eda de bastidor de servidor <\/a><a href=\"https:\/\/www.kmdpower.com\/es\/solar-batteries\/\" target=\"_blank\" rel=\"noreferrer noopener\">fabricante <\/a><a href=\"https:\/\/www.kmdpower.com\/es\/solar-batteries\/\">en china<\/a><\/strong>bater\u00eda de bastidor de servidor personalizada seg\u00fan los requisitos. <strong><a href=\"https:\/\/www.kmdpower.com\/es\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Contacto kamada power<\/a><\/strong> pida presupuesto.<\/p>","protected":false},"excerpt":{"rendered":"<p>Entrar en una sala de servidores o incluso mirar un rack puede parecer confuso al principio. \u00bfC\u00f3mo encaja todo ese equipo? Ah\u00ed es donde entra en juego la unidad de rack o \"U\". Es la medida est\u00e1ndar del espacio vertical en los racks de servidores. Comprender la \"U\" es clave para cualquiera que maneje hardware de servidor: le indica exactamente...<\/p>","protected":false},"author":1,"featured_media":2549,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-4381","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/4381","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/comments?post=4381"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/4381\/revisions"}],"predecessor-version":[{"id":4382,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/posts\/4381\/revisions\/4382"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/media\/2549"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/media?parent=4381"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/categories?post=4381"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/es\/wp-json\/wp\/v2\/tags?post=4381"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}