{"id":5335,"date":"2026-11-25T05:36:02","date_gmt":"2026-11-25T05:36:02","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5335"},"modified":"2026-11-25T05:36:04","modified_gmt":"2026-11-25T05:36:04","slug":"can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/de\/news\/can-sodium-ion-battery-keep-truck-liftgates-working-across-a-full-winter-delivery-route\/","title":{"rendered":"K\u00f6nnen Natrium-Ionen-Batterien den Betrieb von LKW-Hebeb\u00fchnen w\u00e4hrend einer gesamten winterlichen Lieferroute aufrechterhalten?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Eine voll aufgeladene Heckklappenbatterie garantiert nicht, dass gen\u00fcgend Energie f\u00fcr die letzte Auslieferung vorhanden ist. Wiederholte Hydraulikvorg\u00e4nge, kurze Fahrten und eingeschr\u00e4nkte Ladem\u00f6glichkeiten im Winter f\u00fchren zu kumulativen Defiziten. F\u00fcr Heckklappen-Erstausr\u00fcster und Fahrzeugausr\u00fcster, <strong><a href=\"https:\/\/www.kmdpower.com\/de\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natriumbatterie<\/a><\/strong> Die Eignung h\u00e4ngt von der verf\u00fcgbaren Energie am schwierigsten Punkt der Strecke, einer ausreichenden Motorleistung und der Wiederauff\u00fcllung vor dem n\u00e4chsten Arbeitstag ab.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Sodium-Battery-12V-100Ah-Bluetooth-Low-Temperature-Na-Ion-Battery-Supplier-Factory-Manufacturers-001.jpg\" alt=\"\" class=\"wp-image-1451\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/de\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12v 100Ah Natrium-Ionen-Akku<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Warum f\u00fchren wiederholte Stopps zu einem Energieverlust bei der Ladebordwand?<\/h2><p class=\"wp-block-paragraph\">Eine Heckklappenbatterie versorgt die Hydraulikanlage an Haltestellen mit Strom und kann sich w\u00e4hrend der Fahrt wieder aufladen. Eine <a href=\"https:\/\/purkeys.net\/case-study-how-purkeys-direct-helped-keep-under-charged-liftgates-off-the-road\/\" target=\"_blank\" rel=\"noreferrer noopener\">Von Purkeys gemeldeter Fall im Zusammenhang mit der Flotte<\/a> beschreibt, dass entladene Batterien das Anheben der Plattformen verhindern, sodass ein Pannendienst erforderlich wird. Es handelt sich hierbei nicht um einen Feldversuch mit Natrium-Ionen-Batterien.<\/p><p class=\"wp-block-paragraph\">Ein Lkw kann mehrere Paletten entladen und in nur wenigen Minuten zum n\u00e4chsten Kunden weiterfahren. Eine voll aufgeladene Batterie kann eine unzureichende Aufladung am ersten Tag verschleiern, wenn die Aufladung \u00fcber Nacht im Depot nicht ausreicht.<\/p><p class=\"wp-block-paragraph\">Der Winter wirkt sich sowohl auf die Energieversorgung als auch auf den Energiebedarf aus. Kalte Batterien verf\u00fcgen m\u00f6glicherweise \u00fcber weniger verf\u00fcgbare Energie und geringere Ladegrenzen. Kalte Hydraulikfl\u00fcssigkeit kann sich je nach Fl\u00fcssigkeit, Pumpe und Ger\u00e4teauslegung auf die Betriebsdauer und den Motorbedarf auswirken. Messen Sie diese Auswirkungen, anstatt einen pauschalen Winterkorrekturfaktor anzuwenden.<\/p><p class=\"wp-block-paragraph\">Lange Kabel und Anschl\u00fcsse k\u00f6nnen die Ladespannung verringern. Ein spezielles DC\/DC-Ladeger\u00e4t f\u00fcr die Heckklappe kann diesen Verlust ausgleichen, doch sein Vorhandensein bedeutet noch nicht, dass das Ger\u00e4t mit Natrium-Ionen-Batterien kompatibel ist.<\/p><h2 class=\"wp-block-heading\">Wie viel Energie verbraucht eine voll beladene Lieferroute?<\/h2><p class=\"wp-block-paragraph\">Die auf dem Typenschild angegebene Motorleistung sagt nichts \u00fcber den t\u00e4glichen Energiebedarf aus. Das Ladegewicht, die Hubh\u00f6he, der Wirkungsgrad der Hydraulik und die Betriebsdauer beeinflussen den Verbrauch ebenso wie die Frage, ob das Absenken motorisch oder durch Schwerkraft erfolgt.<\/p><p class=\"wp-block-paragraph\">Messen Sie Spannung und Strom an den Batterieklemmen w\u00e4hrend repr\u00e4sentativer Betriebsvorg\u00e4nge der Heckklappe. Die pro Zyklus verbrauchte elektrische Energie betr\u00e4gt:<\/p><p class=\"wp-block-paragraph\"><strong>Energie pro Zyklus (Wh) = Integral von V(t) \u00d7 I(t) \u00fcber die Zeit \u00f7 3.600<\/strong><\/p><p class=\"wp-block-paragraph\">Die Spannung wird in Volt gemessen, der Strom in Ampere und die Zeit in Sekunden.<\/p><p class=\"wp-block-paragraph\">Erfassen Sie Lastfahrten, Leerfahrten, R\u00fcckfahrten und Wartezeiten separat, einschlie\u00dflich ungew\u00f6hnlich anspruchsvoller Stopps. Z\u00e4hlen Sie R\u00fcckfahrten nicht doppelt, wenn sie bereits in einem vollst\u00e4ndigen Zyklus enthalten sind.<\/p><p class=\"wp-block-paragraph\">Die folgende hypothetische Route veranschaulicht die Berechnung. Zur Veranschaulichung der Gr\u00f6\u00dfenordnung dient die <a href=\"https:\/\/www.maxonlift.com\/sites\/default\/files\/manuals\/2017-01\/operators-handbook-gpc-x1-ld-gpc-x1-ldf-20908422_2.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">MAXON GPC X1-LD\/LDF \u2013 Bedienungsanleitung, Seite 5<\/a> gibt 150 A bei 12 V an und empfiehlt f\u00fcr das Beispiel mit einer Traglast von 600 kg eine 88-Ah-Batterie. Bei 12 V und 150 A verbraucht ein 36 Sekunden dauernder, \u00e4quivalenter Betrieb 18 Wh. Dies ist eine Veranschaulichung in der Gr\u00f6\u00dfenordnung, kein gemessener Zyklus und keine Behauptung, dass der Strom konstant bleibt.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Routenenergieparameter<\/th><th class=\"has-text-align-right\" data-align=\"right\">Illustrativer Wert<\/th><\/tr><\/thead><tbody><tr><td>Vollst\u00e4ndige Hub- und R\u00fccklaufzyklen<\/td><td class=\"has-text-align-right\" data-align=\"right\">30<\/td><\/tr><tr><td>Durchschnittlicher Energieverbrauch pro Zyklus<\/td><td class=\"has-text-align-right\" data-align=\"right\">18 Wh<\/td><\/tr><tr><td>Energiebedarf f\u00fcr den Betrieb der Ladebordwand<\/td><td class=\"has-text-align-right\" data-align=\"right\">540 Wh<\/td><\/tr><tr><td>Verbrauch des Controllers und im Standby-Modus<\/td><td class=\"has-text-align-right\" data-align=\"right\">60 Wh<\/td><\/tr><tr><td>Gesamtenergiebedarf an den Batterieklemmen<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>Tats\u00e4chliche Ladezeit des Fahrzeugs<\/td><td class=\"has-text-align-right\" data-align=\"right\">2 Stunden<\/td><\/tr><tr><td>Durchschnittliche zul\u00e4ssige Ladeleistung<\/td><td class=\"has-text-align-right\" data-align=\"right\">120 W<\/td><\/tr><tr><td>An die Batterieklemmen gelieferte Energie<\/td><td class=\"has-text-align-right\" data-align=\"right\">240 Wh<\/td><\/tr><tr><td>T\u00e4gliches Endverbrauchsdefizit<\/td><td class=\"has-text-align-right\" data-align=\"right\">360 Wh<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Das Fahrzeug gibt lediglich 40% der verbrauchten Energie zur\u00fcck. Die verbleibenden 360 Wh m\u00fcssen aus dem vorhandenen Batteriespeicher bezogen werden, wobei zus\u00e4tzliche interne Batterieverluste zu ber\u00fccksichtigen sind. F\u00fcnf identische Arbeitstage ohne zus\u00e4tzliches Aufladen w\u00fcrden zu einem kumulativen Endenergie-Defizit von 1.800 Wh f\u00fchren.<\/p><p class=\"wp-block-paragraph\">Energieausreichendheit ist nicht gleichbedeutend mit Motorkompatibilit\u00e4t. In einem technischen Datenblatt zum Kamada Power 12 V\/100 Ah sind eine maximale Dauerentladung von 100 A und ein Impuls von 150 A mit einer Dauer von weniger als 3 Millisekunden angegeben. Diese Werte reichen nicht aus, um einen einzelnen Akku f\u00fcr einen mehrere Sekunden andauernden 150-A-Hub zu qualifizieren. Vergleichen Sie das Strom-Zeit-Profil des Motors \u2013 einschlie\u00dflich Anlaufstrom, Neustarts unter Last und thermischer Grenzwerte bei wiederholten Zyklen \u2013 mit den zugelassenen Grenzwerten des Akkupacks bei der zu erwartenden Temperatur. \u00dcberpr\u00fcfen Sie die Mindestspannung an den Motorklemmen. Ein \u00fcberm\u00e4\u00dfiger Spannungsabfall im Kabel oder eine Abschaltung durch das Batteriemanagementsystem (BMS) kann den Betrieb unterbrechen, selbst wenn noch gespeicherte Energie vorhanden ist. Die in dieser Referenz angegebene Schutzabschaltung bei 8 V ist standardm\u00e4\u00dfig keine zul\u00e4ssige Betriebsspannung f\u00fcr den Motor.<\/p><h2 class=\"wp-block-heading\">Kann die Fahrzeit im Winter den Energieverbrauch bei jedem Halt ausgleichen?<\/h2><p class=\"wp-block-paragraph\">Ein DC-DC-Ladeger\u00e4t mit einer Nennleistung von 40 A liefert w\u00e4hrend einer Winterfahrt nicht unbedingt durchgehend 40 A an die Heckklappenbatterie. Der zul\u00e4ssige Ladestrom h\u00e4ngt von der Fahrzeugstromversorgung, den Ausgangseigenschaften des Ladeger\u00e4ts, der Temperatur und dem Ladezustand (SOC) der Batterie sowie den f\u00fcr die fertige Batterie festgelegten Grenzwerten ab.<\/p><p class=\"wp-block-paragraph\">Die w\u00e4hrend jedes Fahrintervalls zugef\u00fchrte Energie betr\u00e4gt:<\/p><p class=\"wp-block-paragraph\"><strong>Ladeenergie (Wh) = Integral aus Vcharge(t) \u00d7 Iaccepted(t) \u00fcber die Zeit \u00f7 3.600<\/strong><\/p><p class=\"wp-block-paragraph\">Verwenden Sie den tats\u00e4chlich von der Batterie aufgenommenen Strom und nicht die maximale Nennleistung des Ladeger\u00e4ts. Wenn Nebenlasten w\u00e4hrend der Fahrt aktiv bleiben, ber\u00fccksichtigen Sie diese separat oder verwenden Sie durchgehend die Nettoleistung an den Batterieklemmen.<\/p><p class=\"wp-block-paragraph\">Nehmen wir eine hypothetische Ladespannung von 13,5 V und eine Fahrzeit von 15 Minuten an. Bei 10 A erh\u00e4lt die Batterie 33,75 Wh. Bei 20 A erh\u00e4lt sie 67,5 Wh. Bei 40 A erh\u00e4lt sie 135 Wh. Diese Werte gehen von konstanter Spannung und konstantem Strom aus und ber\u00fccksichtigen keine internen Speicherverluste. Es handelt sich hierbei nicht um Ladestromspezifikationen f\u00fcr eine Kamada Power-Batterie.<\/p><p class=\"wp-block-paragraph\">Zum Kontext: In der technischen Referenz f\u00fcr 12 V\/100 Ah sind 10 A bei \u221220 \u00b0C bis \u221210 \u00b0C und 20 A bei \u221210 \u00b0C bis 0 \u00b0C angegeben. Diese Grenzwerte sind revisionsspezifisch. Die Referenz beschreibt das Standard-CC\/CV-Laden bei 0\u201345 \u00b0C; \u00fcberpr\u00fcfen Sie die Grenzwerte f\u00fcr Spannung, Strom, Ladeabbruch und Temperatur sowie das Verhalten des BMS bei Temperaturen unter Null separat. Ein leistungsst\u00e4rkeres Ladeger\u00e4t kann diese Grenzwerte nicht au\u00dfer Kraft setzen. Auch sollte die routinem\u00e4\u00dfige Stromregelung nicht von Schutzabschaltungen des BMS abh\u00e4ngig sein. Das <a href=\"https:\/\/www.purkeys.net\/wp-content\/uploads\/2018\/07\/Direct-01-Installation-Guide.pdf\" target=\"_blank\" rel=\"noopener\">Purkeys Direct \u2013 Installationsanleitung<\/a> beschreibt die Erh\u00f6hung der Ladespannung bei kaltem Wetter. Ein vorhandenes Temperaturkompensationsprofil f\u00fcr Blei-S\u00e4ure-Batterien muss daher anhand der zugelassenen Spannungs- und Stromgrenzwerte des Natrium-Ionen-Akkus \u00fcberpr\u00fcft werden; der Referenzwert von 15,6 V ist ein H\u00f6chstwert und kein allgemeing\u00fcltiger Ladesollwert.<\/p><p class=\"wp-block-paragraph\">Ein f\u00fcr das Laden bei Minustemperaturen zugelassenes Akku-Pack kann eine Alternative zu Systemen darstellen, die das Laden unterhalb des Gefrierpunkts einschr\u00e4nken, vorausgesetzt, die Anforderungen an Motorstrom und Spannung werden erf\u00fcllt. Allein anhand von Zelluntersuchungen lassen sich keine Grenzwerte f\u00fcr das Laden des fertigen Akku-Packs oder die Energier\u00fcckgewinnung im Winter ermitteln.<\/p><p class=\"wp-block-paragraph\">Die Ladegrenze richtet sich nach der Batterietemperatur und nicht nach der Umgebungstemperatur. Ein im Anh\u00e4nger montierter Akku kann auch nach dem Warmlaufen des Motors noch kalt bleiben, was die Ladef\u00e4higkeit auf kurzen Fahrten einschr\u00e4nkt.<\/p><p class=\"wp-block-paragraph\">Ein f\u00fcnfmin\u00fctiges Fahrintervall bei 120 W liefert lediglich 10 Wh. Wenn der vorangegangene Heckklappenbetrieb 18 Wh verbraucht hat, bleibt ein weiteres Energie-Defizit von 8 Wh bestehen, noch bevor Speicherverluste hinzukommen. L\u00e4ngere Fahrintervalle im weiteren Verlauf des Tages k\u00f6nnen dieses Defizit zwar ausgleichen, helfen jedoch nicht bei einer Lieferung, die vor diesen Intervallen stattfindet.<\/p><h2 class=\"wp-block-heading\">Wo erreicht die Strecke ihren tiefsten Energiespeicher?<\/h2><p class=\"wp-block-paragraph\">Routen mit identischem Tagesverbrauch, identischer Ladeleistung und identischer Endreserve k\u00f6nnen unterschiedliche Mindestenergieanforderungen aufweisen, da die Liefer- und Ladevorg\u00e4nge in unterschiedlicher Reihenfolge stattfinden.<\/p><p class=\"wp-block-paragraph\">Kehren wir zu der hypothetischen Strecke zur\u00fcck, auf der 600 Wh verbraucht und 240 Wh Ladeenergie aufgenommen werden. Nehmen wir an, dass zu Beginn 800 Wh verf\u00fcgbare gespeicherte Energie vorhanden sind. Teilen Sie den Bedarf in drei Lieferbl\u00f6cke zu je 200 Wh auf, einschlie\u00dflich des zugewiesenen Standby-Verbrauchs, und die Ladeenergie in zwei Bl\u00f6cke zu je 120 Wh. Nehmen Sie f\u00fcr diesen vereinfachten Vergleich an, dass die Ladeenergie vollst\u00e4ndig zur\u00fcckgewinnbar ist, die Temperatur konstant bleibt und bei keinem der beiden Ladebl\u00f6cke eine vollgeladene Batterie vorliegt.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Betriebsphase<\/th><th class=\"has-text-align-right\" data-align=\"right\">Route A \u2013 Verteilte Lieferungen<\/th><th class=\"has-text-align-right\" data-align=\"right\">Route B \u2013 Geb\u00fcndelte Lieferungen<\/th><\/tr><\/thead><tbody><tr><td>Abfahrt<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">800 Wh<\/td><\/tr><tr><td>Erster Lieferblock<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">600 Wh<\/td><\/tr><tr><td>N\u00e4chste Veranstaltung<\/td><td class=\"has-text-align-right\" data-align=\"right\">720 Wh (Ladung)<\/td><td class=\"has-text-align-right\" data-align=\"right\">400 Wh (Nennleistung)<\/td><\/tr><tr><td>N\u00e4chste Veranstaltung<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (Nennleistung)<\/td><td class=\"has-text-align-right\" data-align=\"right\">520 Wh (Ladung)<\/td><\/tr><tr><td>N\u00e4chster Ladepunkt<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">640 Wh<\/td><\/tr><tr><td>Letzter Lieferblock<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><td class=\"has-text-align-right\" data-align=\"right\">440 Wh<\/td><\/tr><tr><td>Mindestrestenergie<\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>440 Wh<\/strong><\/td><td class=\"has-text-align-right\" data-align=\"right\"><strong>400 Wh<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png\" alt=\"\" class=\"wp-image-5338\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Remaining-Energy-Along-Two-Delivery-Routes.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Beide Routen enden mit 440 Wh. Route B erreicht jedoch ihre niedrigste Reserve bereits vor der ersten nennenswerten Ladem\u00f6glichkeit. Bei einer angenommenen Mindestbetriebsreserve von 420 Wh erf\u00fcllt Route A die Energieanforderung, w\u00e4hrend Route B diese nicht erf\u00fcllt.<\/p><p class=\"wp-block-paragraph\">F\u00fcr das vereinfachte Modell bei konstanter Temperatur und ohne Verluste gilt:<\/p><p class=\"wp-block-paragraph\"><strong>Erforderliche verf\u00fcgbare Startenergie \u2265 maximales kumulatives Energiedefizit der Strecke + erforderliche Betriebsreserve.<\/strong><\/p><p class=\"wp-block-paragraph\">Unter den dargestellten Bedingungen betr\u00e4gt das maximale kumulative Defizit 360 Wh f\u00fcr Route A und 400 Wh f\u00fcr Route B. Um eine Reserve von 420 Wh aufrechtzuerhalten, sind mindestens 780 Wh bzw. 820 Wh an verf\u00fcgbarer Startenergie erforderlich. Die Reserve von 420 Wh dient lediglich als Beispiel und stellt keine allgemeing\u00fcltige Empfehlung dar. Legen Sie die tats\u00e4chliche Reserve unter Ber\u00fccksichtigung der noch erforderlichen Hubzyklen, unerwarteter Lieferungen, des Alterungsprozesses und der Unsicherheiten bei kaltem Wetter fest; \u00fcberpr\u00fcfen Sie die Lastspannung unabh\u00e4ngig davon.<\/p><p class=\"wp-block-paragraph\">Erfassen Sie in der Praxis die verf\u00fcgbare Energie nach jedem Abgabe- und Ladevorgang. Begrenzen Sie die Nachf\u00fcllung auf den verf\u00fcgbaren Speicherplatz und ber\u00fccksichtigen Sie interne Verluste. Passen Sie die verf\u00fcgbare Energie bei \u00c4nderungen der Betriebstemperatur entsprechend an.<\/p><h2 class=\"wp-block-heading\">Wann ist eine Modernisierung des Ladesystems effektiver als der Einbau einer neuen Batterie?<\/h2><p class=\"wp-block-paragraph\">F\u00fcr OEMs, die eine <a href=\"https:\/\/www.kmdpower.com\/de\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 100Ah Natrium-Ionen-Akku<\/a>, bieten vom Hersteller zugelassene Parallelkonfigurationen eine M\u00f6glichkeit, die Speicherkapazit\u00e4t zu erh\u00f6hen. Auf der Grundlage eines beispielhaften 12-V-Nennwert-Designs entsprechen 1P, 2P, 3P und 4P 100 Ah, 200 Ah, 300 Ah und 400 Ah bzw. 1.200 Wh, 2.400 Wh, 3.600 Wh und 4.800 Wh. Hierbei handelt es sich um Nennwerte und nicht um gemessene nutzbare Energie. Der verlinkte Katalog listet ein 12,8-V-Modell auf; die hier verwendete technische Referenz f\u00fcr 12 V darf ohne Best\u00e4tigung nicht als dieselbe Version angesehen werden. Ermitteln Sie vor der Freigabe des Designs die genaue Artikelnummer (SKU) und die zugelassenen Grenzwerte.<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png\" alt=\"\" class=\"wp-image-5336\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Nominal-Parallel-Battery-Energy.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><p class=\"wp-block-paragraph\">Falls ein Akkupack die f\u00fcr den konzentrierten Betrieb erforderlichen 820 Wh nicht liefern kann, sollten Sie eine gr\u00f6\u00dfere zugelassene Konfiguration in Betracht ziehen. Ermitteln Sie die verf\u00fcgbare Energie bei der erwarteten Temperatur und der Betriebsspannung des Ger\u00e4ts und st\u00fctzen Sie sich dabei nicht allein auf die Nennkapazit\u00e4t.<\/p><p class=\"wp-block-paragraph\">Bei ausreichender Aufladung im Depot \u00fcber Nacht kann eine gr\u00f6\u00dfere Batteriebank auch Spitzenauslastungen abdecken, ohne dass ein Ladeger\u00e4t mit h\u00f6herer Nennleistung erforderlich ist.<\/p><p class=\"wp-block-paragraph\">Ohne Aufladen \u00fcber Nacht verz\u00f6gert die zus\u00e4tzliche Kapazit\u00e4t lediglich das wiederkehrende t\u00e4gliche Defizit von 360 Wh.<\/p><p class=\"wp-block-paragraph\">F\u00fcr die Beispielroute sind durchschnittlich mindestens 300 W erforderlich, um den t\u00e4glichen Endverbrauchsbedarf von 600 Wh \u00fcber zwei Stunden effektiver Ladezeit auszugleichen. Bei einer beispielhaften Ladespannung von 13,5 V entspricht dies einem zul\u00e4ssigen Strom von etwa 22,2 A, bevor interne Speicherverluste ber\u00fccksichtigt werden. Bei 13,5 V erh\u00e4lt ein einzelner Akku, der auf 10 A oder 20 A begrenzt ist, in zwei Stunden nur 270 Wh bzw. 540 Wh, was vor Abzug der Verluste ein Defizit von 330 Wh bzw. 60 Wh hinterl\u00e4sst. Ber\u00fccksichtigen Sie die zugelassene Parallel-Ladekapazit\u00e4t, l\u00e4ngere Ladeintervalle oder das Laden im Depot; ein gr\u00f6\u00dferes Ladeger\u00e4t allein kann die Grenzen des Akkupacks nicht \u00fcberwinden.<\/p><p class=\"wp-block-paragraph\">Die Beschaffungsentscheidung erfolgt unter vier Voraussetzungen:<\/p><ul class=\"wp-block-list\"><li><strong>Vor\u00fcbergehender Energieengpass:<\/strong> Erh\u00f6hen Sie den nutzbaren Lagerplatz oder verlegen Sie eine verf\u00fcgbare Ladem\u00f6glichkeit vor den anspruchsvollen Liefertermin.<\/li>\n\n<li><strong>Wiederholt zu niedrige Abrechnung:<\/strong> Verbesserung der kompatiblen Nachschubversorgung durch Aufladung in Fahrzeugen oder Depots.<\/li>\n\n<li><strong>Beide Bedingungen:<\/strong> Vergleichen Sie die kombinierten Speicher- und Ladeanforderungen anhand des chronologischen Routenprotokolls.<\/li>\n\n<li><strong>Inkompatibilit\u00e4t von Motor oder Spannung:<\/strong> Verzichten Sie auf einen direkten Austausch und ziehen Sie eine separat entwickelte OEM-Plattform in Betracht.<\/li><\/ul><p class=\"wp-block-paragraph\">Bei einer Betriebslast von 150 A ergibt sich bei einer idealen Lastverteilung auf 1P, 2P, 3P und 4P eine Belastung von jeweils 150 A, 75 A, 50 A und 37,5 A pro Batterieblock. Bei einem Referenzwert von 100 A Dauerstromgrenze scheidet 1P bei dieser ersten Pr\u00fcfung des Dauerstroms aus; 2P\u20134P erfordern eine Bewertung, keine automatische Zulassung. Bei einer 2P-Batteriebank k\u00f6nnte der verbleibende Akku 150 A tragen, wenn ein Zweig ausf\u00e4llt. Die tats\u00e4chliche Lastverteilung, Grenzwerte bei niedrigen Temperaturen, der Zweigschutz und das sichere Abschaltverhalten m\u00fcssen festgelegt werden. Wenn zugelassene Parallelschaltungen die Anforderungen an Motor oder Ladung nicht erf\u00fcllen k\u00f6nnen, sollte ein Hochleistungs-OEM-Batteriepaket in Betracht gezogen werden, anstatt den Schutz zu umgehen. Nachr\u00fcstungen m\u00fcssen die elektrischen Anforderungen und Zulassungsbedingungen der Fahrzeug- und Heckklappenhersteller erf\u00fcllen.<\/p><figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png\" alt=\"\" class=\"wp-image-5337\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-1024x683.png 1024w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-768x512.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load-600x400.png 600w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/Per-Pack-Current-Under-a-150A-Liftgate-Load.png 1152w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><h2 class=\"wp-block-heading\">FAQ<\/h2><h3 class=\"wp-block-heading\">Kann ein 100-Ah-Akku eine Heckklappe antreiben?<\/h3><p class=\"wp-block-paragraph\">M\u00f6glicherweise. Eine fertige 100-Ah-Natrium-Ionen-Batterie muss die Anforderungen des Hydraulikmotors hinsichtlich Stromst\u00e4rke und Dauer, die Grenzwerte f\u00fcr die Lastspannung sowie das maximale kumulative Energiedefizit auf der Strecke erf\u00fcllen. Reicht ein Batteriepack nicht aus, k\u00f6nnen vom Hersteller zugelassene Parallelkonfigurationen oder eine eigenst\u00e4ndig entwickelte OEM-Batterie in Betracht gezogen werden. Die Nennkapazit\u00e4t sagt nichts \u00fcber die direkte Austauschkompatibilit\u00e4t aus.<\/p><h3 class=\"wp-block-heading\">Werden zwei Akkus das Problem der kurzen Fahrzeiten beheben?<\/h3><p class=\"wp-block-paragraph\">Zwei zugelassene Parallelbatterien k\u00f6nnen zwischen den Ladem\u00f6glichkeiten eine gr\u00f6\u00dfere Betriebsreserve bieten. Sie erh\u00f6hen jedoch nicht zwangsl\u00e4ufig die bei kurzen Fahrten zur\u00fcckgewonnene Energie. Wenn der t\u00e4gliche Verbrauch weiterhin den Nachschub \u00fcbersteigt, ist nach wie vor eine kompatible Ladeaufr\u00fcstung oder zus\u00e4tzliches Laden im Depot erforderlich.<\/p><h3 class=\"wp-block-heading\">Ben\u00f6tigt ein DC\/DC-Ladeger\u00e4t ein Natrium-Ionen-Profil?<\/h3><p class=\"wp-block-paragraph\">Das Ladeger\u00e4t muss den Anforderungen des ausgew\u00e4hlten Akkus hinsichtlich Spannung, Stromst\u00e4rke, Temperatur und Ladeabbruch entsprechen. Ein spezielles Natrium-Ionen-Profil kann zwar geeignet sein, doch seine Bezeichnung allein garantiert noch keine Kompatibilit\u00e4t. Vorhandene Einstellungen f\u00fcr Blei-S\u00e4ure- oder Lithium-Ionen-Akkus sollten nur verwendet werden, wenn ihr tats\u00e4chliches Verhalten f\u00fcr die jeweilige Akku- und Ger\u00e4tekonfiguration zugelassen ist.<\/p><h2 class=\"wp-block-heading\">Schlussfolgerung<\/h2><p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/de\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Natrium-Ionen-Batterien<\/a><\/strong> kommen als Winter-Ladebordwandsysteme f\u00fcr Lkw in Frage, wenn ihre nutzbare Energie, die Motorstrombelastbarkeit, die Betriebsspannung und die temperaturabh\u00e4ngigen Ladegrenzen mit dem Liefer-Arbeitszyklus \u00fcbereinstimmen. Das maximale kumulative Routendefizit bestimmt die erforderliche Startenergie, w\u00e4hrend die t\u00e4gliche Nachf\u00fcllbilanz dar\u00fcber entscheidet, ob das System aufeinanderfolgende Arbeitstage bew\u00e4ltigen kann. F\u00fcr Standard- <strong><a href=\"https:\/\/www.kmdpower.com\/de\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 100Ah Natrium-Ionen-Akku<\/a><\/strong>, zugelassene Parallelkonfigurationen oder m\u00f6gliche kundenspezifische Batteriekonstruktionen f\u00fcr Heckklappen, <a href=\"https:\/\/www.kmdpower.com\/de\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kontaktieren Sie Kamada Power<\/a> Ihre l\u00e4ngste Winterauslieferungsstrecke, das Stromprofil des Hydraulikmotors, die Ladespezifikationen des Fahrzeugs und den erwarteten Batterietemperaturbereich, um eine anwendungsspezifische Batterie- und Ladearchitektur zu er\u00f6rtern.<\/p>","protected":false},"excerpt":{"rendered":"<p>Eine voll aufgeladene Heckklappenbatterie garantiert nicht, dass gen\u00fcgend Energie f\u00fcr die letzte Auslieferung vorhanden ist. Wiederholte Hydraulikvorg\u00e4nge, kurze Fahrten und eingeschr\u00e4nkte Ladem\u00f6glichkeiten im Winter f\u00fchren zu kumulativen Defiziten. F\u00fcr Heckklappen-Erstausr\u00fcster und Fahrzeugausr\u00fcster h\u00e4ngt die Eignung von Natriumbatterien von der nutzbaren Energie am anspruchsvollsten Punkt der Route, einer ausreichenden Motorleistung und der Wiederaufladung vor dem n\u00e4chsten Arbeitstag ab\u2026<\/p>","protected":false},"author":1,"featured_media":1451,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/posts\/5335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/comments?post=5335"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/posts\/5335\/revisions"}],"predecessor-version":[{"id":5339,"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/posts\/5335\/revisions\/5339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/media\/1451"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/media?parent=5335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/categories?post=5335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/de\/wp-json\/wp\/v2\/tags?post=5335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}