{"id":5340,"date":"2026-11-25T08:26:42","date_gmt":"2026-11-25T08:26:42","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5340"},"modified":"2026-11-25T08:27:02","modified_gmt":"2026-11-25T08:27:02","slug":"how-off-freezer-charging-affects-cold-storage-workstation-productivity-and-sodium-ion-battery-selection","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/cs\/news\/how-off-freezer-charging-affects-cold-storage-workstation-productivity-and-sodium-ion-battery-selection\/","title":{"rendered":"Jak nab\u00edjen\u00ed mimo mraz\u00e1k ovliv\u0148uje produktivitu pracovn\u00edch stanic v chlad\u00edrensk\u00fdch skladech a v\u00fdb\u011br sod\u00edkov\u00fdch iontov\u00fdch bateri\u00ed"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Mobiln\u00ed pracovn\u00ed stanice, kter\u00e1 byla vyjmuta z mraz\u00e1ku za \u00fa\u010delem nabit\u00ed, nem\u016f\u017ee uvnit\u0159 mraz\u00e1ku tisknout \u0161t\u00edtky ani zpracov\u00e1vat z\u00e1soby. Toto p\u0159eru\u0161en\u00ed m\u016f\u017ee zahrnovat p\u0159em\u00edst\u011bn\u00ed voz\u00edku, \u010dek\u00e1n\u00ed na zah\u0159\u00e1t\u00ed baterie, samotn\u00e9 nab\u00edjen\u00ed a n\u00e1vrat do provozu. A <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">sod\u00edkovo-iontov\u00e1 baterie<\/a><\/strong> Tento proces lze zkr\u00e1tit, pokud schv\u00e1len\u00e1 nab\u00edjec\u00ed stanice poskytuje dostate\u010dn\u00fd nab\u00edjec\u00ed v\u00fdkon. Samotn\u00e9 nab\u00edjen\u00ed p\u0159i n\u00edzk\u00e9 teplot\u011b v\u0161ak nen\u00ed dostate\u010dn\u00fdm d\u016fvodem pro zm\u011bnu bateriov\u00e9 platformy. Praktickou ot\u00e1zkou je, kolik \u010dasu str\u00e1ven\u00e9ho na pracovn\u00ed stanici lze u\u0161et\u0159it a zda je tento \u010das natolik cenn\u00fd, aby ovlivnil rozhodnut\u00ed o n\u00e1kupu za\u0159\u00edzen\u00ed.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/Sodium-Battery-12V-100Ah-Bluetooth-Low-Temperature-Na-Ion-Battery-Supplier-Factory-Manufacturers-001.jpg\" alt=\"\" class=\"wp-image-1451\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/cs\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sod\u00edkov\u00e1 baterie Kamada Power 12 V, 100 Ah<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Kde doch\u00e1z\u00ed p\u0159i nab\u00edjen\u00ed mimo mraz\u00e1k ke ztr\u00e1t\u011b produktivn\u00edho \u010dasu?<\/h2><p class=\"wp-block-paragraph\">Na str\u00e1nk\u00e1ch <a href=\"https:\/\/solcon-systemtechnik.de\/en\/product\/mobilwagen-1100g\/?attribute_pa_abklappbare-tischplatten=no&amp;attribute_pa_akku=battery-lead-acid-12v-100ah-350w&amp;attribute_pa_halter=no&amp;attribute_pa_rammschutz=no\" target=\"_blank\" rel=\"noreferrer noopener\">Mobiln\u00ed pracovn\u00ed stanice Solcon 1100G<\/a> Ilustruje t\u0159\u00eddu za\u0159\u00edzen\u00ed: olov\u011bno-kyselinov\u00e1 konfigurace 12 V, 100 Ah, jmenovit\u00fd trval\u00fd v\u00fdkon 350 W, nab\u00edje\u010dka 10 A a voliteln\u00e9 \u0159e\u0161en\u00ed pro v\u00fdm\u011bnu bateri\u00ed. Jeho uzav\u0159en\u00e1 konstrukce je ur\u010dena pro pou\u017eit\u00ed v chlad\u00edrensk\u00fdch prostorech. Jedn\u00e1 se o referen\u010dn\u00ed popis za\u0159\u00edzen\u00ed, nikoli o schv\u00e1lenou sod\u00edko-iontovou instalaci.<\/p><p class=\"wp-block-paragraph\">Na str\u00e1nk\u00e1ch <a href=\"https:\/\/www.acd-gruppe.de\/en\/portable-devices\/mobile-workstations\/mobile-workstation-max\/max-tk\/\" target=\"_blank\" rel=\"noreferrer noopener\">Pracovn\u00ed stanice pro hlubok\u00e9 mra\u017een\u00ed ACD MAX BE TK<\/a> vyu\u017e\u00edv\u00e1 dv\u011b olov\u011bn\u00e9 baterie 12 V, 60 Ah v syst\u00e9mu o nap\u011bt\u00ed 24 V. Provozn\u00ed p\u0159\u00edru\u010dka k za\u0159\u00edzen\u00ed MAX BE\/MAX Plus (V1.03, odstavce 20.3.1 a 25.2) vy\u017eaduje nab\u00edjen\u00ed mimo mraz\u00e1k, doporu\u010duje p\u0159ed nab\u00edjen\u00edm okoln\u00ed teplotu nejm\u00e9n\u011b 15 \u00b0C (59 \u00b0F) a omezuje dobu provozu se stejnou p\u016fvodn\u00ed sadou bateri\u00ed na osm hodin z d\u016fvodu rizika zamrznut\u00ed elektrolytu. Typick\u00e1 doba provozu je p\u0159ibli\u017en\u011b osm hodin p\u0159i zat\u00ed\u017een\u00ed 50 VA, nikoli p\u0159i ka\u017ed\u00e9m zat\u00ed\u017een\u00ed. Tato omezen\u00ed plat\u00ed pro danou konfiguraci za\u0159\u00edzen\u00ed.<\/p><p class=\"wp-block-paragraph\">Mezi p\u0159\u00edklady nab\u00edjen\u00ed mimo mraz\u00e1k mohou pat\u0159it:<\/p><ul class=\"wp-block-list\"><li>Cesta tam a zp\u011bt, p\u0159ipojen\u00ed a odpojen\u00ed.<\/li>\n\n<li>Stabilizace teploty a \u010dek\u00e1n\u00ed na voln\u00e9 nab\u00edjec\u00ed m\u00edsto.<\/li>\n\n<li>Skute\u010dn\u00e1 doba nab\u00edjen\u00ed, b\u011bhem n\u00ed\u017e voz\u00edk nem\u016f\u017ee plnit sv\u016fj p\u0159id\u011blen\u00fd \u00fakol.<\/li><\/ul><p class=\"wp-block-paragraph\">Prostoje voz\u00edku je t\u0159eba po\u010d\u00edtat odd\u011blen\u011b od u\u0161l\u00e9 pracovn\u00ed s\u00edly. Zam\u011bstnanci mohou b\u011bhem nab\u00edjen\u00ed voz\u00edku vykon\u00e1vat jin\u00e9 \u00fakoly, i kdy\u017e jejich kolegov\u00e9 mus\u00ed odlo\u017eit \u00fakoly, k nim\u017e pot\u0159ebuj\u00ed tisk\u00e1rnu nebo termin\u00e1l tohoto voz\u00edku.<\/p><h2 class=\"wp-block-heading\">O kolik se b\u011bhem jedn\u00e9 sm\u011bny sn\u00ed\u017e\u00ed dostupnost pracovn\u00edch stanic?<\/h2><p class=\"wp-block-paragraph\">Dostupnost m\u011b\u0159te podle po\u010dtu hodin, b\u011bhem nich\u017e je voz\u00edk pot\u0159ebn\u00fd ve sv\u00e9 p\u0159id\u011blen\u00e9 pracovn\u00ed z\u00f3n\u011b, a nikoli pouze podle po\u010dtu hodin, kdy je zapnut\u00fd.<\/p><p class=\"wp-block-paragraph\">Se\u010dt\u011bte nep\u0159ekr\u00fdvaj\u00edc\u00ed se intervaly j\u00edzdy, zastaven\u00ed v p\u0159\u00edstavi\u0161ti, zah\u0159\u00edv\u00e1n\u00ed, \u010dek\u00e1n\u00ed ve front\u011b a nab\u00edjen\u00ed, kter\u00e9 br\u00e1n\u00ed poskytov\u00e1n\u00ed slu\u017eby. Pokud k zah\u0159\u00edv\u00e1n\u00ed a \u010dek\u00e1n\u00ed na nab\u00edje\u010dku doch\u00e1z\u00ed sou\u010dasn\u011b, zapo\u010d\u00edtejte tento interval pouze jednou.<\/p><p class=\"wp-block-paragraph\"><strong>Po\u010det dostupn\u00fdch pracovn\u00edch hodin = Pl\u00e1novan\u00e9 provozn\u00ed hodiny \u2013 Nedostupn\u00e9 hodiny, kter\u00e9 se nep\u0159ekr\u00fdvaj\u00ed.<\/strong><\/p><p class=\"wp-block-paragraph\">P\u0159edpokl\u00e1dejme, \u017ee osmhodinov\u00e1 sm\u011bna zahrnuje dv\u011b doj\u00ed\u017e\u010fky za \u00fa\u010delem nab\u00edjen\u00ed, z nich\u017e ka\u017ed\u00e1 vy\u017eaduje 20 minut j\u00edzdy a p\u0159ipojen\u00ed k nab\u00edjec\u00ed stanici, plus 40 minut nep\u0159ekr\u00fdvaj\u00edc\u00ed se prostoje b\u011bhem nab\u00edjen\u00ed. V tomto p\u0159\u00edkladu se nepo\u010d\u00edt\u00e1 s \u017e\u00e1dn\u00fdm dodate\u010dn\u00fdm zah\u0159\u00edv\u00e1n\u00edm ani \u010dek\u00e1n\u00edm ve front\u011b.<\/p><p class=\"wp-block-paragraph\">Voz\u00edk ztrat\u00ed 80 minut, \u010d\u00edm\u017e zb\u00fdv\u00e1 6 hodin a 40 minut provozn\u00ed doby (dostupnost 83,31 TP3T).<\/p><p class=\"wp-block-paragraph\">Schv\u00e1len\u00e9 dokovac\u00ed m\u00edsto v z\u00f3n\u011b, kter\u00e9 eliminuje pouze dobu j\u00edzdy a dokov\u00e1n\u00ed, zvy\u0161uje dostupnost na 7 hodin a 20 minut (91,71 TP3T).<\/p><p class=\"wp-block-paragraph\">Tento hypotetick\u00fd \u010dasov\u00fd pl\u00e1n p\u0159edpokl\u00e1d\u00e1 dostate\u010dnou rekuperaci energie; nejedn\u00e1 se o \u00fadaje z ter\u00e9nn\u00edch test\u016f.<\/p><p class=\"wp-block-paragraph\"><em>Obr\u00e1zek 1. Ilustrativn\u00ed dostupnost sm\u011bn p\u0159i stejn\u00e9 d\u00e9lce nab\u00edjen\u00ed.<\/em><\/p><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"768\" height=\"512\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-workstation-charging-timeline.png\" alt=\"\" class=\"wp-image-5341\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-workstation-charging-timeline.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-workstation-charging-timeline-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-workstation-charging-timeline-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-workstation-charging-timeline-600x400.png 600w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure><p class=\"wp-block-paragraph\">Ka\u017ed\u00fd blok cesty p\u0159edstavuje souhrnnou dobu na cestu tam i zp\u011bt a \u010das na zakotven\u00ed; sch\u00e9ma p\u0159edstavuje p\u0159ehled doby slu\u017eby, nikoli fyzick\u00fd pr\u016fb\u011bh cesty.<\/p><p class=\"wp-block-paragraph\">Zisk \u010din\u00ed 40 minut, co\u017e odpov\u00edd\u00e1 10% p\u016fvodn\u00edho dostupn\u00e9ho \u010dasu.<\/p><p class=\"wp-block-paragraph\">Deset voz\u00edk\u016f podle tohoto harmonogramu u\u0161et\u0159\u00ed 400 minut na vybaven\u00ed, co\u017e se nemus\u00ed nutn\u011b rovnat \u00faspo\u0159e pr\u00e1ce nebo zv\u00fd\u0161en\u00ed v\u00fdkonu.<\/p><p class=\"wp-block-paragraph\">Pokud se nab\u00edjen\u00ed ji\u017e zcela vejde do p\u0159est\u00e1vky, kdy nikdo voz\u00edk nepot\u0159ebuje, p\u0159esunut\u00ed nab\u00edje\u010dky nemus\u00ed p\u0159in\u00e9st \u017e\u00e1dnou v\u00fdznamnou p\u0159idanou hodnotu. Naopak voz\u00edk, kter\u00fd nen\u00ed k dispozici b\u011bhem \u00fazk\u00e9ho m\u00edsta p\u0159i ozna\u010dov\u00e1n\u00ed, m\u016f\u017ee brzdit pr\u00e1ci, i kdy\u017e jsou zam\u011bstnanci k dispozici.<\/p><h2 class=\"wp-block-heading\">M\u016f\u017ee baterie na ionty sod\u00edku zm\u011bnit m\u00edsto nab\u00edjen\u00ed?<\/h2><p class=\"wp-block-paragraph\">D\u016fle\u017eit\u00e1 je teplota p\u0159i nab\u00edjen\u00ed baterie, provozn\u00ed teplota nab\u00edje\u010dky i celkov\u00e9 environment\u00e1ln\u00ed parametry pracovi\u0161t\u011b. Ka\u017ed\u00e1 sou\u010d\u00e1st mus\u00ed z\u016fstat v r\u00e1mci sv\u00fdch mez\u00ed. Um\u00edst\u011bn\u00ed nab\u00edjec\u00edho stanovi\u0161t\u011b mus\u00ed b\u00fdt v souladu s elektrick\u00fdmi, protipo\u017e\u00e1rn\u00edmi a hygienick\u00fdmi p\u0159edpisy dan\u00e9ho za\u0159\u00edzen\u00ed.<\/p><p class=\"wp-block-paragraph\">Mraz\u00e1k s teplotou -25 \u00b0C (-13 \u00b0F) m\u016f\u017ee b\u00fdt nap\u0159\u00edklad chladn\u011bj\u0161\u00ed, ne\u017e je povolen\u00fd rozsah nab\u00edjen\u00ed dan\u00e9 baterie. Baterii, jej\u00ed\u017e nab\u00edjen\u00ed je omezeno na teplotu -20 \u00b0C (-4 \u00b0F) nebo vy\u0161\u0161\u00ed, nelze nab\u00edjet p\u0159i teplot\u011b baterie -25 \u00b0C. Bl\u00ed\u017ee polo\u017een\u00e1, teplej\u0161\u00ed schv\u00e1len\u00e1 nab\u00edjec\u00ed stanice v\u0161ak m\u016f\u017ee i tak u\u0161et\u0159it \u010das str\u00e1ven\u00fd cestov\u00e1n\u00edm.<\/p><p class=\"wp-block-paragraph\">Teplota baterie nemus\u00ed nutn\u011b odpov\u00eddat pokojov\u00e9 teplot\u011b. Chlad\u00edc\u00ed vlo\u017eka m\u016f\u017ee z\u016fstat studen\u00e1 i po p\u0159enesen\u00ed do tepl\u00e9 m\u00edstnosti; \u0159\u00edzen\u00ed nab\u00edjen\u00ed mus\u00ed reagovat na aktu\u00e1ln\u011b nam\u011b\u0159enou teplotu baterie.<\/p><p class=\"wp-block-paragraph\">Uva\u017eujme hypotetick\u00fd syst\u00e9m t\u0159\u00eddy 12 V, kter\u00fd p\u0159ed dal\u0161\u00edm pracovn\u00edm cyklem pot\u0159ebuje nab\u00edt 120 Wh energie p\u0159i pr\u016fm\u011brn\u00e9m nap\u011bt\u00ed na svork\u00e1ch 13,5 V.<\/p><p class=\"wp-block-paragraph\"><strong>Vstupn\u00ed energie p\u0159i nab\u00edjen\u00ed (Wh) = pr\u016fm\u011brn\u00e9 nap\u011bt\u00ed na svork\u00e1ch \u00d7 p\u0159ij\u00edman\u00fd proud \u00d7 doba nab\u00edjen\u00ed (h).<\/strong><\/p><p class=\"wp-block-paragraph\">P\u0159i proudu 10 A trv\u00e1 nabit\u00ed na 120 Wh p\u0159ibli\u017en\u011b 53 minut; p\u0159i proudu 20 A p\u0159ibli\u017en\u011b 27 minut. Nab\u00edje\u010dka s proudem 10 A nem\u016f\u017ee dos\u00e1hnout druh\u00e9ho v\u00fdsledku jen proto, \u017ee n\u00e1hradn\u00ed baterie umo\u017e\u0148uje proud 20 A.<\/p><p class=\"wp-block-paragraph\">B\u011bhem 20minutov\u00e9 p\u0159est\u00e1vky se dod\u00e1 45 Wh p\u0159i proudu 10 A nebo 90 Wh p\u0159i proudu 20 A. Jedn\u00e1 se o v\u00fdpo\u010dty pro vstup konstantn\u00edho proudu na svork\u00e1ch, nikoli o z\u00e1ruky zp\u011btn\u011b z\u00edskateln\u00e9 energie. V\u00fdsledek ovliv\u0148uj\u00ed ztr\u00e1ty p\u0159i ukl\u00e1d\u00e1n\u00ed, pokles proudu, teplota a p\u0159ipojen\u00e1 z\u00e1t\u011b\u017e.<\/p><p class=\"wp-block-paragraph\">P\u0159edchoz\u00ed \u010dasov\u00fd pl\u00e1n vych\u00e1z\u00ed z p\u0159edpokladu, \u017ee doby nab\u00edjen\u00ed jsou stejn\u00e9. Pro ov\u011b\u0159en\u00ed tohoto p\u0159edpokladu uva\u017eujme samostatn\u00fd p\u0159\u00edpad, kter\u00fd vy\u017eaduje 180 Wh vstupn\u00edho v\u00fdkonu na svork\u00e1ch za sm\u011bnu. P\u0159i nap\u011bt\u00ed 13,5 V a proudu 20 A vy\u017eaduje \u201etepl\u00e1\u201c dokovac\u00ed stanice 40 minut nab\u00edjen\u00ed plus 40 minut j\u00edzdy. Schv\u00e1len\u00e1 studen\u00e1 dokovac\u00ed stanice p\u0159i proudu 10 A vy\u017eaduje 80 minut nab\u00edjen\u00ed: nedoch\u00e1z\u00ed k \u017e\u00e1dn\u00e9 \u00faspo\u0159e \u010dasu. P\u0159i proudu 20 A to trv\u00e1 40 minut, \u010d\u00edm\u017e se u\u0161et\u0159\u00ed cel\u00e1 doba vyhrazen\u00e1 na dojezd.<\/p><p class=\"wp-block-paragraph\"><strong>\u010cist\u00e1 u\u0161et\u0159en\u00e1 doba servisu = U\u0161et\u0159en\u00e1 doba p\u0159epravy a manipulace + Prostoj p\u0159i nab\u00edjen\u00ed za tepla \u2013 Prostoj p\u0159i nab\u00edjen\u00ed za studena.<\/strong><\/p><p class=\"wp-block-paragraph\">V tomto p\u0159\u00edkladu \u010din\u00ed proud rovnov\u00e1hy 10 A; kladn\u00e9 zes\u00edlen\u00ed vy\u017eaduje proud vy\u0161\u0161\u00ed ne\u017e 10 A, pokud nap\u011bt\u00ed a v\u0161echny ostatn\u00ed p\u0159edpoklady z\u016fstanou nezm\u011bn\u011bny. Pou\u017eijte skute\u010dn\u00fd \u010dist\u00fd v\u00fdkon baterie a nep\u0159ekr\u00fdvaj\u00edc\u00ed se prostoje, nikoli jmenovit\u00fd proud nab\u00edje\u010dky. Del\u0161\u00ed dostupn\u00e1 pracovn\u00ed doba m\u016f\u017ee sama o sob\u011b zv\u00fd\u0161it spot\u0159ebu energie, proto v\u00fdpo\u010det energetick\u00e9ho rozpo\u010dtu zopakujte pro upravenou sm\u011bnu.<\/p><p class=\"wp-block-paragraph\"><em>Obr\u00e1zek 2. Ilustrativn\u00ed model rovnov\u00e1hy doby nab\u00edjen\u00ed; nejedn\u00e1 se o nam\u011b\u0159en\u00e9 hodnoty.<\/em><\/p><figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"768\" height=\"512\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-cold-charging-break-even.png\" alt=\"\" class=\"wp-image-5342\" srcset=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-cold-charging-break-even.png 768w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-cold-charging-break-even-300x200.png 300w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-cold-charging-break-even-18x12.png 18w, https:\/\/www.kmdpower.com\/wp-content\/uploads\/f02-cold-charging-break-even-600x400.png 600w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure><p class=\"wp-block-paragraph\">Pro technick\u00e9 posouzen\u00ed, ji\u017e d\u0159\u00edve dodan\u00fd <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sada sod\u00edkov\u00fdch iontov\u00fdch bateri\u00ed Kamada Power<\/a><\/strong> V technick\u00fdch \u00fadaj\u00edch je uvedeno 10 A v rozmez\u00ed -20 a\u017e -10 \u00b0C a 20 A v rozmez\u00ed -10 a\u017e 0 \u00b0C, s v\u00fdhradou p\u0159esn\u00fdch teplotn\u00edch mez\u00ed a potvrzen\u00e9 revize nap\u00e1jec\u00edho zdroje. P\u0159i teplot\u00e1ch pod -20 \u00b0C se nab\u00edjen\u00ed nach\u00e1z\u00ed mimo tento referen\u010dn\u00ed rozsah. Nejedn\u00e1 se o ov\u011b\u0159en\u00e9 specifikace pro ka\u017edou variantu propojen\u00e9ho produktu. Bl\u00ed\u017ee um\u00edst\u011bn\u00e1 schv\u00e1len\u00e1 dokovac\u00ed stanice v n\u00e1razn\u00edkov\u00e9 z\u00f3n\u011b m\u016f\u017ee b\u00fdt proto u\u017eite\u010dn\u011bj\u0161\u00ed ne\u017e dokovac\u00ed stanice uvnit\u0159 mraz\u00e1ku.<\/p><p class=\"wp-block-paragraph\">Pokud motorov\u00fd voz\u00edk odeb\u00edr\u00e1 100 W ze sb\u011brnice stejnosm\u011brn\u00e9ho proudu, kter\u00e1 je nap\u00e1jena 135 W z nab\u00edje\u010dky, zb\u00fdv\u00e1 na nab\u00edjen\u00ed baterie nanejv\u00fd\u0161 35 W p\u0159ed dal\u0161\u00edmi ztr\u00e1tami. P\u0159i vy\u0161\u0161\u00edm odb\u011bru m\u016f\u017ee doj\u00edt k vyb\u00edjen\u00ed baterie. P\u0159i pou\u017eit\u00ed samostatn\u00e9ho nap\u00e1jec\u00edho zdroje p\u0159ipojen\u00e9ho k s\u00edti a nab\u00edje\u010dky baterie nemus\u00ed z\u00e1t\u011b\u017e spot\u0159ebov\u00e1vat v\u00fdstupn\u00ed v\u00fdkon tohoto nab\u00edjec\u00edho obvodu, i kdy\u017e st\u00e1le plat\u00ed omezen\u00ed dan\u00e1 nap\u00e1jec\u00edm zdrojem. Za\u0159\u00edzen\u00ed mus\u00ed v\u00fdslovn\u011b podporovat provoz b\u011bhem nab\u00edjen\u00ed.<\/p><p class=\"wp-block-paragraph\">Pro novou 12V platformu, a <a href=\"https:\/\/www.kmdpower.com\/cs\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 100Ah sod\u00edko-iontov\u00e1 baterie<\/a> je vhodnou volbou. Zvolte konkr\u00e9tn\u00ed revizi bateriov\u00e9ho modulu tak, aby odpov\u00eddala rozsahu nap\u011bt\u00ed st\u0159\u00edda\u010de, p\u0159echodov\u00fdm jev\u016fm z\u00e1t\u011b\u017ee, profilu nab\u00edjen\u00ed, limit\u016fm syst\u00e9mu BMS a nab\u00edjec\u00edmu proudu p\u0159i n\u00edzk\u00fdch teplot\u00e1ch. Vyrovn\u00e1v\u00e1n\u00ed olov\u011bn\u00fdch bateri\u00ed nebo teplotn\u00ed kompenzace nemus\u00ed b\u00fdt kompatibiln\u00ed. Ochrann\u00e9 odpojen\u00ed baterie nen\u00ed rovno minim\u00e1ln\u00edmu provozn\u00edmu nap\u011bt\u00ed st\u0159\u00edda\u010de.<\/p><p class=\"wp-block-paragraph\">Konektory a kryty ur\u010den\u00e9 pro provoz v chladn\u00e9m prost\u0159ed\u00ed mus\u00ed rovn\u011b\u017e odol\u00e1vat dan\u00fdm podm\u00ednk\u00e1m prost\u0159ed\u00ed a riziku kondenzace p\u0159i teplotn\u00edch zm\u011bn\u00e1ch. Pokud v\u00fdrobce pracovn\u00ed stanice zakazuje nab\u00edjen\u00ed v mraz\u00e1ku, pou\u017eit\u00ed jin\u00e9 baterie toto omezen\u00ed nezru\u0161\u00ed; nov\u00e1 architektura nab\u00edjen\u00ed vy\u017eaduje schv\u00e1len\u00ed za\u0159\u00edzen\u00ed i provozovny.<\/p><h2 class=\"wp-block-heading\">Jak si v\u00fdm\u011bna bateri\u00ed vede ve srovn\u00e1n\u00ed s dob\u00edjen\u00edm v pracovn\u00ed z\u00f3n\u011b?<\/h2><p class=\"wp-block-paragraph\">V\u00fdm\u011bnn\u00fd syst\u00e9m vr\u00e1t\u00ed voz\u00edk do provozu s nabitou bateri\u00ed, zat\u00edmco vybit\u00e1 baterie se nab\u00edj\u00ed samostatn\u011b. Tento syst\u00e9m se hod\u00ed pro po sob\u011b jdouc\u00ed sm\u011bny, kr\u00e1tk\u00e9 p\u0159est\u00e1vky nebo provozy, kde nen\u00ed povoleno nab\u00edjen\u00ed v mraz\u00e1ku.<\/p><p class=\"wp-block-paragraph\">Nap\u0159\u00edklad voz\u00edk, jeho\u017e z\u00e1suvky st\u0159\u00eddav\u00e9ho proudu dod\u00e1vaj\u00ed v pr\u016fm\u011bru 100 W po dobu osmi hodin, p\u0159i\u010dem\u017e \u00fa\u010dinnost m\u011bni\u010de je 90% a do t\u00e9to \u00fa\u010dinnosti nen\u00ed zahrnuto 80 Wh dodate\u010dn\u00e9ho zat\u00ed\u017een\u00ed na stran\u011b stejnosm\u011brn\u00e9ho proudu, pot\u0159ebuje:<\/p><p class=\"wp-block-paragraph\"><strong>(100 W \u00d7 8 h \u00f7 0,90) + 80 Wh \u2248 969 Wh.<\/strong><\/p><p class=\"wp-block-paragraph\">Jmenovit\u00e1 kapacita 12 V a 100 Ah odpov\u00edd\u00e1 1 200 Wh, tak\u017ee v tomto p\u0159\u00edkladu bez dob\u00edjen\u00ed je t\u0159eba m\u00edt k dispozici alespo\u0148 80,81 TP3T jmenovit\u00e9 energie je\u0161t\u011b p\u0159ed zapo\u010d\u00edt\u00e1n\u00edm rezervy. Do skute\u010dn\u00e9ho profilu zat\u00ed\u017een\u00ed je nutn\u00e9 zahrnout \u0161pi\u010dkov\u00e9 zat\u00ed\u017een\u00ed tisk\u00e1rny, term\u00e1ln\u00ed p\u0159\u00edslu\u0161enstv\u00ed a spot\u0159ebu v pohotovostn\u00edm re\u017eimu. Vyu\u017eiteln\u00e1 energie nad mezn\u00ed hodnotou za\u0159\u00edzen\u00ed mus\u00ed pokr\u00fdt spot\u0159ebu i rezervu. Jmenovit\u00fd v\u00fdkon 350 W nep\u0159edstavuje pr\u016fm\u011brnou spot\u0159ebu.<\/p><p class=\"wp-block-paragraph\">Na stejn\u00e9m nomin\u00e1ln\u00edm z\u00e1klad\u011b p\u0159edstavuj\u00ed schv\u00e1len\u00e9 banky 1P\u20134P hodnoty 1,2, 2,4, 3,6 a 4,8 kWh. K dosa\u017een\u00ed kapacity 969 Wh bez dob\u00edjen\u00ed nebo rezervy jsou zapot\u0159eb\u00ed dostupn\u00e9 frakce p\u0159ibli\u017en\u011b 80,81 TP3T, 40,41 TP3T, 26,91 TP3T a 20,21 TP3T. Jedn\u00e1 se o prahov\u00e9 hodnoty pro dimenzov\u00e1n\u00ed, nikoli o nam\u011b\u0159en\u00fd v\u00fdkon baterie. V\u011bt\u0161\u00ed bateriov\u00e9 soustavy zvy\u0161uj\u00ed hmotnost a vy\u017eaduj\u00ed dostate\u010dn\u00e9 no\u010dn\u00ed dob\u00edjen\u00ed. Paraleln\u00ed roz\u0161\u00ed\u0159en\u00ed zachov\u00e1v\u00e1 nap\u011b\u0165ovou t\u0159\u00eddu 12 V; nem\u016f\u017ee p\u0159\u00edmo nap\u00e1jet architekturu ACD 24 V. Pro syst\u00e9my 24 V nebo v p\u0159\u00edpad\u011b omezen\u00e9ho instala\u010dn\u00edho prostoru je k dispozici samostatn\u011b vyvinut\u00fd OEM akumul\u00e1torov\u00fd modul, kter\u00fd podl\u00e9h\u00e1 schv\u00e1len\u00ed.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>N\u00e1vrhov\u00fd p\u0159\u00edstup<\/th><th>Hlavn\u00ed v\u00fdhoda z hlediska dostupnosti<\/th><th>Omezen\u00ed, kter\u00e9 m\u016f\u017ee tento p\u0159\u00ednos zma\u0159it<\/th><\/tr><\/thead><tbody><tr><td>Nab\u00edjen\u00ed mimo mraz\u00e1k<\/td><td>Vyu\u017e\u00edv\u00e1 zavedenou a schv\u00e1lenou nab\u00edjec\u00ed z\u00f3nu<\/td><td>Fronty pro cestov\u00e1n\u00ed, dokov\u00e1n\u00ed, zah\u0159\u00edv\u00e1n\u00ed a nab\u00edjen\u00ed<\/td><\/tr><tr><td>Schv\u00e1len\u00e9 dob\u00edjen\u00ed v dan\u00e9 z\u00f3n\u011b<\/td><td>Vyh\u00fdb\u00e1 se n\u011bkter\u00fdm p\u0159esun\u016fm voz\u00edk\u016f<\/td><td>Nedostate\u010dn\u00fd povolen\u00fd proud, omezen\u00fd po\u010det z\u00e1suvek nebo z\u00e1kaz nab\u00edjen\u00ed v mraz\u00e1ku<\/td><\/tr><tr><td>V\u00fdm\u011bna baterie<\/td><td>Zaji\u0161\u0165uje, \u017ee voz\u00edk z\u016fstane k dispozici, zat\u00edmco se dob\u00edj\u00ed samostatn\u00e1 baterie<\/td><td>Nadbyte\u010dn\u00e9 z\u00e1soby, v\u00fdm\u011bnn\u00e1 pracovn\u00ed s\u00edla a nedostate\u010dn\u00e1 kapacita nab\u00edjen\u00ed<\/td><\/tr><tr><td>V\u011bt\u0161\u00ed vestav\u011bn\u00e1 baterie<\/td><td>M\u016f\u017ee eliminovat nutnost dob\u00edjen\u00ed uprost\u0159ed sm\u011bny<\/td><td>Hmotnost voz\u00edku, prostor, vyu\u017eiteln\u00e1 energie a doba nab\u00edjen\u00ed p\u0159es noc<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Syst\u00e9m v\u00fdm\u011bny pot\u0159ebuje dostate\u010dn\u00fd po\u010det bal\u00ed\u010dk\u016f, aby pokryl dobu p\u0159\u00edpravy. Pokud se ka\u017edou hodinu odebere jedna baterie a jej\u00ed op\u011btovn\u00e1 p\u0159\u00edprava trv\u00e1 t\u0159i hodiny, mohou b\u00fdt v ust\u00e1len\u00e9m stavu v procesu v\u00fdm\u011bny t\u0159i baterie. Pokud nab\u00edjen\u00ed zab\u00edr\u00e1 v\u0161echny t\u0159i hodiny, jsou zapot\u0159eb\u00ed t\u0159i nez\u00e1visl\u00e1 nab\u00edjec\u00ed stanovi\u0161t\u011b. Pokud \u010d\u00e1st \u010dasu zab\u00edr\u00e1 oh\u0159\u00edv\u00e1n\u00ed nebo \u010dek\u00e1n\u00ed ve front\u011b, vypo\u010d\u00edtejte obsazenost nab\u00edje\u010dky samostatn\u011b. Po\u010d\u00edtejte s mo\u017en\u00fdmi soub\u011b\u017en\u00fdmi v\u00fdm\u011bnami a zpo\u017ed\u011bn\u00edmi.<\/p><p class=\"wp-block-paragraph\">U v\u00fdm\u011bn, kter\u00e9 vy\u017eaduj\u00ed odst\u00e1vku, zapo\u010d\u00edtejte do prostojov\u00e9 doby transakce ukl\u00e1d\u00e1n\u00ed, restart a p\u0159esun.<\/p><h2 class=\"wp-block-heading\">Kdy m\u016f\u017ee nab\u00edjen\u00ed v mraz\u00e1ku sn\u00ed\u017eit po\u010det pot\u0159ebn\u00fdch pracovn\u00edch stanic?<\/h2><p class=\"wp-block-paragraph\">D\u00edky u\u0161et\u0159en\u00e9mu \u010dasu se m\u016f\u017ee sn\u00ed\u017eit po\u010det voz\u00edk\u016f, kter\u00e9 mus\u00ed integr\u00e1tor zakoupit. Velikost vozov\u00e9ho parku z\u00e1vis\u00ed na celkov\u00e9m po\u010dtu provozn\u00edch hodin, soub\u011b\u017en\u00e9 popt\u00e1vce a rezervn\u00edm vybaven\u00ed.<\/p><p class=\"wp-block-paragraph\">V\u00fdpo\u010det kapacity v prvn\u00edm kroku je n\u00e1sleduj\u00edc\u00ed:<\/p><p class=\"wp-block-paragraph\"><strong>Minim\u00e1ln\u00ed po\u010det voz\u00edk\u016f podle provozn\u00edch hodin = Po\u017eadovan\u00fd po\u010det pracovn\u00edch hodin na pracovn\u00ed stanici za sm\u011bnu \u00f7 Po\u010det dostupn\u00fdch hodin na voz\u00edk, zaokrouhleno nahoru.<\/strong><\/p><p class=\"wp-block-paragraph\">P\u0159edpokl\u00e1dejme, \u017ee sklad pot\u0159ebuje 80 pracovn\u00edch hodin na pracovn\u00ed stanici b\u011bhem osmihodinov\u00e9 sm\u011bny, p\u0159i\u010dem\u017e je t\u0159eba sou\u010dasn\u011b vyu\u017e\u00edvat deset voz\u00edk\u016f. P\u0159edpokl\u00e1dejme flexibiln\u00ed p\u0159id\u011blov\u00e1n\u00ed \u00fakol\u016f a postupn\u00e9 p\u0159eru\u0161en\u00ed pr\u00e1ce. P\u0159idejme pro ilustraci mo\u017enost v\u00fdm\u011bny bateri\u00ed s celkovou dobou prostoje 20 minut na jeden voz\u00edk za sm\u011bnu.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Architektura nab\u00edjen\u00ed<\/th><th class=\"has-text-align-right\" data-align=\"right\">Dostupn\u00e9 hodiny na voz\u00edk<\/th><th class=\"has-text-align-right\" data-align=\"right\">Minim\u00e1ln\u00ed po\u010det voz\u00edk\u016f podle provozn\u00ed doby<\/th><th class=\"has-text-align-right\" data-align=\"right\">S jedn\u00edm uk\u00e1zkov\u00fdm voz\u00edkem pro pohotovostn\u00ed re\u017eim<\/th><\/tr><\/thead><tbody><tr><td>Nab\u00edjen\u00ed mimo mraz\u00e1k<\/td><td class=\"has-text-align-right\" data-align=\"right\">6.67<\/td><td class=\"has-text-align-right\" data-align=\"right\">12<\/td><td class=\"has-text-align-right\" data-align=\"right\">13<\/td><\/tr><tr><td>Schv\u00e1len\u00e9 dob\u00edjen\u00ed v dan\u00e9 z\u00f3n\u011b<\/td><td class=\"has-text-align-right\" data-align=\"right\">7.33<\/td><td class=\"has-text-align-right\" data-align=\"right\">11<\/td><td class=\"has-text-align-right\" data-align=\"right\">12<\/td><\/tr><tr><td>V\u00fdm\u011bna baterie<\/td><td class=\"has-text-align-right\" data-align=\"right\">7.67<\/td><td class=\"has-text-align-right\" data-align=\"right\">11<\/td><td class=\"has-text-align-right\" data-align=\"right\">12<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Uve\u010fte p\u0159esn\u00fd po\u010det minut, nikoli zaokrouhlen\u00e9 hodiny. Hypotetick\u00e1 mo\u017enost v\u00fdm\u011bny p\u0159edpokl\u00e1d\u00e1 dostate\u010dn\u00fd po\u010det nabit\u00fdch bateri\u00ed a dostate\u010dnou nab\u00edjec\u00ed kapacitu. Jeden n\u00e1hradn\u00ed voz\u00edk slou\u017e\u00ed pouze jako ilustrativn\u00ed rezerva, nejedn\u00e1 se o obecn\u00e9 doporu\u010den\u00ed.<\/p><p class=\"wp-block-paragraph\">\u00daspora 40 minut na jeden voz\u00edk sni\u017euje doln\u00ed hranici servisn\u00ed doby z dvan\u00e1cti voz\u00edk\u016f na jeden\u00e1ct. To v\u0161ak neznamen\u00e1, \u017ee lze jeden voz\u00edk vy\u0159adit: synchronizovan\u00e9 nab\u00edjen\u00ed nebo nerovnom\u011brn\u00e1 popt\u00e1vka mohou zp\u016fsobit, \u017ee skute\u010dn\u00e1 pot\u0159eba bude vy\u0161\u0161\u00ed.<\/p><p class=\"wp-block-paragraph\">Porovnejte popt\u00e1vku s po\u010dtem dostupn\u00fdch voz\u00edk\u016f v jednotliv\u00fdch \u010dasov\u00fdch \u00fasec\u00edch. P\u0159i jeden\u00e1cti voz\u00edc\u00edch a deseti po\u017eadovan\u00fdch sou\u010dasn\u011b by dv\u011b soub\u011b\u017en\u00e1 p\u0159eru\u0161en\u00ed nab\u00edjen\u00ed znamenala, \u017ee by z\u016fstalo k dispozici pouze dev\u011bt voz\u00edk\u016f. Provozn\u00ed flotila mus\u00ed spl\u0148ovat jak doln\u00ed hranici provozn\u00edch hodin, tak skute\u010dn\u00fd pl\u00e1n soub\u011b\u017en\u00e9 popt\u00e1vky, ne\u017e bude mo\u017en\u00e9 p\u0159idat jakoukoli samostatnou pohotovostn\u00ed rezervu. N\u00e1hradn\u00ed baterie nem\u016f\u017ee nahradit porouchanou tisk\u00e1rnu nebo m\u011bni\u010d; n\u00e1hradn\u00ed sady a n\u00e1hradn\u00ed kazety slou\u017e\u00ed k odli\u0161n\u00fdm \u00fa\u010del\u016fm.<\/p><p class=\"wp-block-paragraph\">Pokud ob\u011b varianty p\u0159inesou jeden\u00e1ct voz\u00edk\u016f, porovnejte voln\u00e9 skladov\u00e9 z\u00e1soby, infrastrukturu, \u00fapravy a n\u00e1klady na manipulaci. Pro st\u00e1vaj\u00edc\u00ed plynul\u00fd pracovn\u00ed postup nemus\u00ed b\u00fdt ani jedna z t\u011bchto variant p\u0159\u00edli\u0161 p\u0159\u00ednosn\u00e1.<\/p><p class=\"wp-block-paragraph\">P\u0159epo\u010d\u00edtejte p\u0159\u00edr\u016fstkov\u00e9 n\u00e1klady na za\u0159\u00edzen\u00ed a baterie na ro\u010dn\u00ed b\u00e1zi a porovnejte je s prokazateln\u00fdmi \u00fasporami za n\u00e1kup voz\u00edk\u016f, mzdov\u00fdmi n\u00e1klady a p\u0159eru\u0161en\u00edmi provozu. \u00dasporu za voz\u00edk zapo\u010d\u00edtejte pouze v p\u0159\u00edpad\u011b, \u017ee pl\u00e1n pokr\u00fdv\u00e1 sou\u010dasnou popt\u00e1vku i po\u017eadovanou rezervu. Nevypo\u010d\u00edt\u00e1vejte dvakr\u00e1t u\u0161et\u0159en\u00e9 mzdov\u00e9 n\u00e1klady a propustnost.<\/p><h2 class=\"wp-block-heading\">\u010cASTO KLADEN\u00c9 DOTAZY<\/h2><h3 class=\"wp-block-heading\">Je mo\u017en\u00e9 nab\u00edjet v jak\u00e9mkoli mraz\u00e1ku?<\/h3><p class=\"wp-block-paragraph\">Ne. Baterie, nab\u00edje\u010dka, pracovn\u00ed stanice i za\u0159\u00edzen\u00ed mus\u00ed v\u0161echny umo\u017e\u0148ovat nab\u00edjen\u00ed za skute\u010dn\u00fdch provozn\u00edch podm\u00ednek. Pokud p\u0159edpisy pro za\u0159\u00edzen\u00ed zakazuj\u00ed nab\u00edjen\u00ed v mraz\u00e1ku, pou\u017eijte m\u00edsto toho schv\u00e1lenou vyh\u0159\u00edvanou dokovac\u00ed stanici nebo syst\u00e9m v\u00fdm\u011bny bateri\u00ed.<\/p><h3 class=\"wp-block-heading\">Sta\u010d\u00ed 100 Ah na celou sm\u011bnu?<\/h3><p class=\"wp-block-paragraph\">Z\u00e1le\u017e\u00ed na nam\u011b\u0159en\u00e9m zat\u00ed\u017een\u00ed, ztr\u00e1t\u00e1ch p\u0159i p\u0159em\u011bn\u011b energie, dostupn\u00e9 energii baterie p\u0159i provozn\u00ed teplot\u011b, rezerv\u011b a dopln\u011bn\u00ed energie v polovin\u011b sm\u011bny. Samotn\u00e1 jmenovit\u00e1 kapacita 100 Ah nesta\u010d\u00ed k zaji\u0161t\u011bn\u00ed provozu po celou sm\u011bnu.<\/p><h3 class=\"wp-block-heading\">Je v\u00fdm\u011bna lep\u0161\u00ed ne\u017e nab\u00edjen\u00ed na m\u00edst\u011b?<\/h3><p class=\"wp-block-paragraph\">V\u00fdm\u011bna bateri\u00ed se hod\u00ed pro nep\u0159etr\u017eit\u00fd provoz, pokud jsou n\u00e1hradn\u00ed sady k dispozici v\u010das. Nab\u00edjen\u00ed na m\u00edst\u011b m\u016f\u017ee b\u00fdt vhodn\u011bj\u0161\u00ed, pokud schv\u00e1len\u00e1 \u010dasov\u00e1 okna pro nab\u00edjen\u00ed pokr\u00fdvaj\u00ed energetickou spot\u0159ebu, ani\u017e by do\u0161lo k p\u0159eru\u0161en\u00ed po\u017eadovan\u00e9ho provozu. Porovnejte celkov\u00e9 n\u00e1klady na prostoje a n\u00e1klady na z\u00e1soby n\u00e1hradn\u00edch bateri\u00ed.<\/p><h2 class=\"wp-block-heading\">Z\u00e1v\u011br<\/h2><p class=\"wp-block-paragraph\">A <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">sod\u00edkov\u00e1 baterie<\/a><\/strong> m\u016f\u017ee zv\u00fd\u0161it dostupnost pracovn\u00edch stanic v chlad\u00edrensk\u00fdch skladech, pokud jej\u00ed schv\u00e1len\u00e1 nab\u00edjec\u00ed teplota a proud zkr\u00e1t\u00ed proces nab\u00edjen\u00ed, ani\u017e by do\u0161lo k nedostatku energie. V z\u00e1vislosti na typu voz\u00edku m\u016f\u017ee b\u00fdt vhodn\u00fdm \u0159e\u0161en\u00edm standardn\u00ed <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">12V 100Ah sod\u00edkov\u00e1 baterie<\/a><\/strong>, schv\u00e1len\u00e1 paraleln\u00ed banka, na zak\u00e1zku <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sada sod\u00edkov\u00fdch iontov\u00fdch bateri\u00ed od v\u00fdrobce OEM<\/a><\/strong>, p\u0159\u00edpadn\u011b syst\u00e9m v\u00fdm\u011bny; zachov\u00e1n\u00ed st\u00e1vaj\u00edc\u00edho m\u00edsta nab\u00edjen\u00ed m\u016f\u017ee b\u00fdt vhodn\u011bj\u0161\u00ed v p\u0159\u00edpadech, kdy zm\u011bnu br\u00e1n\u00ed omezen\u00ed dan\u00e1 za\u0159\u00edzen\u00edm nebo prostorem. <a href=\"https:\/\/www.kmdpower.com\/cs\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kontakt Kamada Power<\/a> s ohledem na v\u00e1\u0161 rozvrh sm\u011bn, teplotu mraz\u00e1ku, nam\u011b\u0159en\u00e9 zat\u00ed\u017een\u00ed voz\u00edku, \u010dasov\u00e1 okna pro dob\u00edjen\u00ed a soub\u011b\u017enou popt\u00e1vku po pracovn\u00edch stanic\u00edch, abychom mohli projednat dimenzov\u00e1n\u00ed bateri\u00ed a porovnat dostupnost slu\u017eeb u jednotliv\u00fdch architektur.<\/p>","protected":false},"excerpt":{"rendered":"<p>Mobiln\u00ed pracovn\u00ed stanice vyvezen\u00e1 z mraz\u00edrny za \u00fa\u010delem nabit\u00ed nem\u016f\u017ee uvnit\u0159 mraz\u00edrny tisknout \u0161t\u00edtky ani zpracov\u00e1vat z\u00e1soby. Toto p\u0159eru\u0161en\u00ed m\u016f\u017ee zahrnovat p\u0159em\u00edst\u011bn\u00ed voz\u00edku, \u010dek\u00e1n\u00ed na zah\u0159\u00e1t\u00ed baterie, samotn\u00e9 nab\u00edjen\u00ed a n\u00e1vrat do provozu. Sod\u00edko-iontov\u00e1 baterie m\u016f\u017ee tento proces zkr\u00e1tit, pokud schv\u00e1len\u00e1 nab\u00edjec\u00ed stanice poskytuje dostate\u010dnou energii k nab\u00edjen\u00ed. Samotn\u00e9 nab\u00edjen\u00ed p\u0159i n\u00edzk\u00e9 teplot\u011b,\u2026<\/p>","protected":false},"author":1,"featured_media":1181,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5340","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts\/5340","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/comments?post=5340"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts\/5340\/revisions"}],"predecessor-version":[{"id":5343,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts\/5340\/revisions\/5343"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/media\/1181"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/media?parent=5340"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/categories?post=5340"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/tags?post=5340"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}