{"id":5236,"date":"2026-06-16T06:18:53","date_gmt":"2026-06-16T06:18:53","guid":{"rendered":"https:\/\/www.kmdpower.com\/?p=5236"},"modified":"2026-06-16T06:18:55","modified_gmt":"2026-06-16T06:18:55","slug":"replacing-telecom-lead-acid-batteries-with-sodium-ion-battery-packs-rectifier-compatibility","status":"publish","type":"post","link":"https:\/\/www.kmdpower.com\/cs\/news\/replacing-telecom-lead-acid-batteries-with-sodium-ion-battery-packs-rectifier-compatibility\/","title":{"rendered":"Nahrazen\u00ed olov\u011bn\u00fdch bateri\u00ed v telekomunika\u010dn\u00edm odv\u011btv\u00ed sod\u00edkov\u00fdmi bateriov\u00fdmi moduly: Kompatibilita s usm\u011br\u0148ova\u010di"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Nahrazen\u00ed olov\u011bn\u00fdch bateri\u00ed v telekomunikac\u00edch <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">sod\u00edkov\u00e9 baterie<\/a><\/strong> Nejde jen o v\u00fdm\u011bnu 48V baterie. Jde o ot\u00e1zku kompatibility stejnosm\u011brn\u00e9ho nap\u00e1jec\u00edho syst\u00e9mu.<\/p><p class=\"wp-block-paragraph\">Sod\u00edkov\u00e1 baterie se sice do sk\u0159\u00edn\u011b vejde, ale v\u00e1\u0161 st\u00e1vaj\u00edc\u00ed usm\u011br\u0148ova\u010d m\u016f\u017ee i nad\u00e1le fungovat podle logiky nab\u00edjen\u00ed olov\u011bn\u00fdch bateri\u00ed. Va\u0161e za\u0159\u00edzen\u00ed m\u016f\u017ee sice proj\u00edt testem zapnut\u00ed, ale n\u00e1sledn\u011b selhat p\u0159i skute\u010dn\u00e9m v\u00fdpadku proudu, dob\u00edjen\u00ed, zpracov\u00e1n\u00ed alarm\u016f nebo d\u00e1lkov\u00e9m obnoven\u00ed provozu.<\/p><p class=\"wp-block-paragraph\">Kl\u00ed\u010dov\u00e1 ot\u00e1zka zn\u00ed:&nbsp;<strong>Je v\u00e1\u0161 usm\u011br\u0148ova\u010d schopen nab\u00edjet, chr\u00e1nit, monitorovat a obnovit bateriov\u00fd modul v r\u00e1mci ov\u011b\u0159en\u00fdch limit\u016f modulu a syst\u00e9mu BMS?<\/strong>&nbsp;V\u0161echna nastaven\u00ed je t\u0159eba porovnat s technick\u00fdm listem sady, n\u00e1vodem k BMS, z\u00e1ru\u010dn\u00edmi podm\u00ednkami a provozn\u00edmi limity regul\u00e1toru.<\/p><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.kmdpower.com\/wp-content\/uploads\/kamada-power-12v-100ah-sodium-ion-battery-main-image-002.jpg\" alt=\"\" class=\"wp-image-1181\"\/><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><strong><a href=\"https:\/\/www.kmdpower.com\/cs\/kamada-poewr-12v-100ah-sodium-ion-battery-product\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kamada Power 12V 100Ah sod\u00edkoiontov\u00e1 baterie<\/a><\/strong><\/p><h2 class=\"wp-block-heading\">Kompatibilita usm\u011br\u0148ova\u010d\u016f nen\u00ed tot\u00e9\u017e jako kompatibilita s nap\u011bt\u00edm 48 V<\/h2><p class=\"wp-block-paragraph\">V\u011bt\u0161ina z\u00e1lo\u017en\u00edch syst\u00e9m\u016f v telekomunikac\u00edch vyu\u017e\u00edv\u00e1 usm\u011br\u0148ova\u010de k nap\u00e1jen\u00ed stejnosm\u011brn\u00fdch spot\u0159ebi\u010d\u016f a z\u00e1rove\u0148 k udr\u017eov\u00e1n\u00ed bateriov\u00e9ho pole. A <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">sod\u00edkovo-iontov\u00e1 baterie<\/a><\/strong> Sada m\u016f\u017ee odpov\u00eddat stejn\u00e9 platform\u011b jmenovit\u00e9ho nap\u011bt\u00ed, av\u0161ak samotn\u00e9 jmenovit\u00e9 nap\u011bt\u00ed je\u0161t\u011b neznamen\u00e1, \u017ee jsou usm\u011br\u0148ova\u010de kompatibiln\u00ed.<\/p><p class=\"wp-block-paragraph\">Pokud se pt\u00e1te: \u201eM\u016f\u017ee va\u0161e 48V sod\u00edko-iontov\u00e1 baterie nahradit mou 48V olov\u011bnou bateriovou sestavu?\u201c, je to jen za\u010d\u00e1tek. Lep\u0161\u00ed ot\u00e1zka zn\u00ed: \u201eZvl\u00e1dnou m\u016fj st\u00e1vaj\u00edc\u00ed usm\u011br\u0148ova\u010d a regul\u00e1tor tuto baterii spr\u00e1vn\u011b \u0159\u00eddit?\u201c<\/p><p class=\"wp-block-paragraph\">V\u00e1\u0161 usm\u011br\u0148ova\u010d monitoruje stav baterie prost\u0159ednictv\u00edm vstup\u016f pro nap\u011bt\u00ed, proud, alarmy, teplotu, bezpotenci\u00e1lov\u00fdch kontakt\u016f a n\u011bkdy i datov\u00fdch sign\u00e1l\u016f CAN nebo RS485. Pokud jsou tyto sign\u00e1ly st\u00e1le nastaveny pro baterie typu VRLA nebo olov\u011bn\u00e9 baterie s tekut\u00fdm elektrolytem, m\u016f\u017ee syst\u00e9m p\u0159i uv\u00e1d\u011bn\u00ed do provozu vypadat norm\u00e1ln\u011b, ale m\u016f\u017ee selhat p\u0159i dob\u00edjen\u00ed, zpracov\u00e1n\u00ed alarm\u016f nebo d\u00e1lkov\u00e9m obnoven\u00ed.<\/p><p class=\"wp-block-paragraph\">D\u00edky \u0161t\u00edtku s ozna\u010den\u00edm 48 V se baterie dostane do sk\u0159\u00edn\u011b. Nastaven\u00ed usm\u011br\u0148ova\u010de ur\u010duje, zda tam bude fungovat bez fale\u0161n\u00fdch poplach\u016f, nedostate\u010dn\u00e9ho nabit\u00ed, spu\u0161t\u011bn\u00ed ochrann\u00fdch mechanism\u016f nebo nutnosti v\u00fdjezdu servisn\u00edho technika.<\/p><h2 class=\"wp-block-heading\">Logiku udr\u017eovac\u00edho a dob\u00edjec\u00edho re\u017eimu u olov\u011bn\u00fdch bateri\u00ed nelze bez rozmyslu kop\u00edrovat<\/h2><p class=\"wp-block-paragraph\">Z\u00e1lo\u017en\u00ed syst\u00e9my s olov\u011bn\u00fdmi bateriemi \u010dasto vyu\u017e\u00edvaj\u00ed udr\u017eovac\u00ed nab\u00edjen\u00ed, zrychlen\u00e9 nab\u00edjen\u00ed, vyrovn\u00e1vac\u00ed re\u017eimy, teplotn\u00ed kompenzaci a nastaven\u00ed LVD (n\u00edzk\u00e9ho nap\u011bt\u00ed), kter\u00e1 jsou volena s ohledem na chov\u00e1n\u00ed bateri\u00ed VRLA nebo zaplaven\u00fdch olov\u011bn\u00fdch bateri\u00ed. Tato nastaven\u00ed by nem\u011bla b\u00fdt bez p\u0159edchoz\u00edho posouzen\u00ed p\u0159en\u00e1\u0161ena do projektu zam\u011b\u0159en\u00e9ho na nahrazen\u00ed sod\u00edkov\u00fdmi iontov\u00fdmi bateriemi.<\/p><p class=\"wp-block-paragraph\">Sod\u00edkov\u011b-iontov\u00e1 baterie m\u00e1 vlastn\u00ed rozsah nab\u00edjec\u00edho nap\u011bt\u00ed, proudov\u00fd limit, ochrann\u00e9 limity, pravidla pro nab\u00edjen\u00ed p\u0159i n\u00edzk\u00fdch teplot\u00e1ch, logiku vyva\u017eov\u00e1n\u00ed a chov\u00e1n\u00ed syst\u00e9mu BMS p\u0159i obnov\u011b. Pokud je udr\u017eovac\u00ed nap\u011bt\u00ed p\u0159\u00edli\u0161 vysok\u00e9, m\u016f\u017ee BMS zablokovat nab\u00edjen\u00ed nebo spustit alarmy. Pokud je p\u0159\u00edli\u0161 n\u00edzk\u00e9, bateriov\u00fd modul nemus\u00ed nikdy dos\u00e1hnout zam\u00fd\u0161len\u00e9ho stavu nabit\u00ed (SOC) v pohotovostn\u00edm re\u017eimu. Pokud z\u016fstane aktivn\u00ed funkce boost nebo vyrovn\u00e1n\u00ed bez schv\u00e1len\u00ed, m\u016f\u017ee syst\u00e9m p\u0159iv\u00e9st baterii do ochrann\u00e9ho re\u017eimu.<\/p><p class=\"wp-block-paragraph\">Mnoho projekt\u016f m\u016f\u017ee i nad\u00e1le vyu\u017e\u00edvat st\u00e1vaj\u00edc\u00ed syst\u00e9m stejnosm\u011brn\u00e9ho nap\u00e1jen\u00ed, pokud je regul\u00e1tor nastaviteln\u00fd a lze zm\u011bnit nastaven\u00ed na m\u00edst\u011b instalace. P\u0159ed vypracov\u00e1n\u00edm nab\u00eddky n\u00e1m pros\u00edm sd\u011blte informace pot\u0159ebn\u00e9 k posouzen\u00ed kompatibility:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Po\u017eadovan\u00e9 informace<\/th><th>Pro\u010d na tom z\u00e1le\u017e\u00ed<\/th><\/tr><\/thead><tbody><tr><td>Model usm\u011br\u0148ova\u010de\/regul\u00e1toru<\/td><td>Potvrzuje rozsah nap\u011bt\u00ed, proudov\u00fd limit, funkci LVD, alarmy a komunikaci<\/td><\/tr><tr><td>Aktu\u00e1ln\u00ed nastaven\u00ed plovouc\u00edho re\u017eimu, boostu a ekvalizace<\/td><td>Ukazuje, zda je t\u0159eba zm\u011bnit logiku nab\u00edjen\u00ed olov\u011bn\u00fdch bateri\u00ed<\/td><\/tr><tr><td>Prahov\u00e9 hodnoty LVD<\/td><td>Zabra\u0148uje p\u0159ed\u010dasn\u00e9mu odpojen\u00ed nebo nouzov\u00e9mu vypnut\u00ed syst\u00e9mu BMS<\/td><\/tr><tr><td>C\u00edlov\u00e1 hodnota vyt\u00ed\u017een\u00ed serveru a po\u010dtu hodin z\u00e1lohov\u00e1n\u00ed<\/td><td>Uv\u00e1d\u00ed kapacitu, vyb\u00edjec\u00ed proud a po\u017eadavky na dob\u00edjen\u00ed<\/td><\/tr><tr><td>Teplotn\u00ed rozsah a po\u010det kus\u016f v balen\u00ed<\/td><td>Kontrola limit\u016f poplatk\u016f, shody SOC a sd\u00edlen\u00ed proudu<\/td><\/tr><tr><td>Protokol monitorov\u00e1n\u00ed nebo rozhran\u00ed alarm\u016f<\/td><td>Potvrzuje stav SOC, SOH a viditelnost alarm\u016f<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Bez t\u011bchto \u00fadaj\u016f lze hovo\u0159it pouze o p\u0159edb\u011b\u017en\u00e9m, nikoli o kone\u010dn\u00e9m schv\u00e1len\u00ed.<\/p><h2 class=\"wp-block-heading\">Usm\u011br\u0148ova\u010d by nem\u011bl b\u00fdt v rozporu s BMS<\/h2><p class=\"wp-block-paragraph\">Syst\u00e9m BMS chr\u00e1n\u00ed sod\u00edko-iontovou baterii p\u0159ed nebezpe\u010dn\u00fdm nap\u011bt\u00edm, proudem, teplotou, nerovnov\u00e1hou, zkratem a hlubok\u00fdm vybit\u00edm. Nem\u011bl by fungovat jako b\u011b\u017en\u00fd regul\u00e1tor nab\u00edjen\u00ed, proto\u017ee usm\u011br\u0148ova\u010d je nespr\u00e1vn\u011b nastaven.<\/p><p class=\"wp-block-paragraph\">V spr\u00e1vn\u011b slad\u011bn\u00e9m syst\u00e9mu se usm\u011br\u0148ova\u010d nab\u00edj\u00ed v r\u00e1mci povolen\u00e9ho rozsahu nap\u011bt\u00ed a proudu akumul\u00e1torov\u00e9ho bloku, p\u0159i\u010dem\u017e cel\u00fd proces \u0159\u00edd\u00ed syst\u00e9m BMS. Pokud v\u00e1\u0161 usm\u011br\u0148ova\u010d pravideln\u011b zp\u016fsobuje p\u0159ep\u011bt\u00ed, zablokov\u00e1n\u00ed nab\u00edjen\u00ed, teplotn\u00ed alarmy nebo nucen\u00e9 odpojen\u00ed, mohou b\u00fdt \u010dl\u00e1nky sice v bezpe\u010d\u00ed, ale z\u00e1lo\u017en\u00ed syst\u00e9m pro telekomunika\u010dn\u00ed za\u0159\u00edzen\u00ed nen\u00ed spolehliv\u00fd.<\/p><p class=\"wp-block-paragraph\">V p\u0159\u00edpad\u011b vzd\u00e1len\u00e9ho stanovi\u0161t\u011b nejsou skute\u010dn\u00fdmi n\u00e1klady pouze po\u0161kozen\u00ed bateri\u00ed. Spu\u0161t\u011bn\u00ed ochrann\u00e9ho mechanismu m\u016f\u017ee v\u00e9st k selh\u00e1n\u00ed nab\u00edjen\u00ed, spu\u0161t\u011bn\u00ed alarmu na stanovi\u0161ti, ztr\u00e1t\u011b monitorov\u00e1n\u00ed, p\u0159eru\u0161en\u00ed provozu nebo nutnosti v\u00fdjezdu servisn\u00edho technika je\u0161t\u011b p\u0159ed dal\u0161\u00edm v\u00fdpadkem. Syst\u00e9m BMS by m\u011bl p\u0159edstavovat posledn\u00ed ochrannou vrstvu, nikoli b\u011b\u017en\u00fd prost\u0159edek k n\u00e1prav\u011b nespr\u00e1vn\u00e9ho profilu nab\u00edjen\u00ed.<\/p><h2 class=\"wp-block-heading\">Nab\u00edjec\u00ed proud ovliv\u0148uje p\u0159ipravenost za\u0159\u00edzen\u00ed po v\u00fdpadku<\/h2><p class=\"wp-block-paragraph\">Z\u00e1lohov\u00e1n\u00ed telekomunika\u010dn\u00edch syst\u00e9m\u016f nekon\u010d\u00ed t\u00edm, \u017ee baterie vydr\u017e\u00ed v\u00fdpadek proudu. Va\u0161e za\u0159\u00edzen\u00ed se mus\u00ed p\u0159ed dal\u0161\u00edm v\u00fdpadkem s\u00edt\u011b vr\u00e1tit do pohotovostn\u00edho re\u017eimu.<\/p><p class=\"wp-block-paragraph\">Pokud je nab\u00edjec\u00ed proud p\u0159\u00edli\u0161 n\u00edzk\u00fd, m\u016f\u017ee se bateriov\u00fd modul po hlubok\u00e9m vybit\u00ed zotavovat p\u0159\u00edli\u0161 pomalu. Pokud je nab\u00edjec\u00ed proud p\u0159\u00edli\u0161 vysok\u00fd, m\u016f\u017ee syst\u00e9m BMS omezit nab\u00edjen\u00ed, aktivovat teplotn\u00ed ochranu nebo zablokovat nab\u00edjen\u00ed, dokud se podm\u00ednky nezlep\u0161\u00ed.<\/p><p class=\"wp-block-paragraph\">To m\u00e1 dopad na re\u00e1ln\u00fd provoz. Va\u0161e za\u0159\u00edzen\u00ed sice m\u016f\u017ee p\u0159i prvn\u00edm v\u00fdpadku splnit po\u017eadovanou dobu z\u00e1lohy, ale pokud je dob\u00edjen\u00ed p\u0159\u00edli\u0161 pomal\u00e9, m\u016f\u017ee do druh\u00e9ho v\u00fdpadku vstoupit s men\u0161\u00ed rezervou, ne\u017e bylo pl\u00e1nov\u00e1no. To je d\u016fle\u017eit\u00e9 zejm\u00e9na u v\u011b\u017e\u00ed na venkov\u011b, v oblastech s nestabiln\u00ed rozvodnou s\u00edt\u00ed, u za\u0159\u00edzen\u00ed vyu\u017e\u00edvaj\u00edc\u00edch sol\u00e1rn\u00ed energii a u vzd\u00e1len\u00fdch rozvad\u011b\u010d\u016f.<\/p><p class=\"wp-block-paragraph\">Nab\u00edjec\u00ed proud z\u00e1vis\u00ed na konstrukci bateriov\u00e9ho modulu, p\u0159ij\u00edmac\u00ed schopnosti syst\u00e9mu BMS, teplot\u011b sk\u0159\u00edn\u011b, hloubce vybit\u00ed, kapacit\u011b usm\u011br\u0148ova\u010de, z\u00e1t\u011b\u017ei v dan\u00e9m m\u00edst\u011b a po\u017eadovan\u00e9 \u00farovni p\u0159ipravenosti. U n\u00e1hradn\u00edch sod\u00edko-iontov\u00fdch bateri\u00ed se jedn\u00e1 o parametr p\u0159ipravenosti dan\u00e9ho m\u00edsta, nikoli pouze o \u00fadaj o rychlosti nab\u00edjen\u00ed.<\/p><h2 class=\"wp-block-heading\">Odpojova\u010d n\u00edzk\u00e9ho nap\u011bt\u00ed mus\u00ed odpov\u00eddat \u010dasov\u00e9mu oknu vyb\u00edjen\u00ed sod\u00edkov\u00fdch iont\u016f<\/h2><p class=\"wp-block-paragraph\">Projekty zam\u011b\u0159en\u00e9 na v\u00fdm\u011bnu olov\u011bn\u00fdch bateri\u00ed se \u010dasto soust\u0159ed\u00ed na nab\u00edjec\u00ed nap\u011bt\u00ed a opom\u00edjej\u00ed str\u00e1nku vyb\u00edjen\u00ed.<\/p><p class=\"wp-block-paragraph\">Telekomunika\u010dn\u00ed syst\u00e9my mohou vyu\u017e\u00edvat nastaven\u00ed odpojen\u00ed p\u0159i n\u00edzk\u00e9m nap\u011bt\u00ed z\u00e1t\u011b\u017ee a baterie. Pokud byly tyto prahov\u00e9 hodnoty nastaveny s ohledem na chov\u00e1n\u00ed olov\u011bn\u00fdch bateri\u00ed, nemus\u00ed odpov\u00eddat nap\u011b\u0165ov\u00e9 k\u0159ivce sod\u00edko-iontov\u00e9ho akumul\u00e1toru ani ochran\u011b proti n\u00edzk\u00e9mu nap\u011bt\u00ed syst\u00e9mu BMS.<\/p><p class=\"wp-block-paragraph\">Pokud je hodnota pro odpojen\u00ed nastavena p\u0159\u00edli\u0161 vysoko, m\u016f\u017ee va\u0161e za\u0159\u00edzen\u00ed nevyu\u017e\u00edt \u010d\u00e1st vyu\u017eiteln\u00e9 kapacity sod\u00edkov\u00fdch iont\u016f. Pokud je naopak nastavena p\u0159\u00edli\u0161 n\u00edzko, m\u016f\u017ee se syst\u00e9m BMS odpojit p\u0159ed\u010dasn\u011b, co\u017e vyvol\u00e1 nouzovou ochranu a zkomplikuje obnoven\u00ed provozu. Preferovan\u00fdm postupem je \u0159\u00edzen\u00e9 \u0159\u00edzen\u00ed z\u00e1t\u011b\u017ee, ne\u017e baterie dos\u00e1hne stavu nouzov\u00e9 ochrany.<\/p><p class=\"wp-block-paragraph\">Nespr\u00e1vn\u00e9 nastaven\u00ed LVD m\u016f\u017ee vypadat jako probl\u00e9m s bateri\u00ed: krat\u0161\u00ed v\u00fddr\u017e, n\u00e1hl\u00e9 vypnut\u00ed nebo nutnost ru\u010dn\u00edho z\u00e1sahu k obnoven\u00ed provozu. Ve skute\u010dnosti v\u0161ak m\u016f\u017ee b\u00fdt p\u0159\u00ed\u010dinou zastaral\u00e9 nastaven\u00ed stejnosm\u011brn\u00e9ho syst\u00e9mu, kter\u00e9 nebylo nikdy p\u0159izp\u016fsobeno nov\u00e9mu chemick\u00e9mu slo\u017een\u00ed baterie.<\/p><h2 class=\"wp-block-heading\">Spole\u010dnost BMS Communication m\u011bn\u00ed standard kompatibility<\/h2><p class=\"wp-block-paragraph\">Jednoduchou sadu olov\u011bn\u00fdch bateri\u00ed lze \u0159\u00eddit p\u0159edev\u0161\u00edm na z\u00e1klad\u011b nap\u011bt\u00ed, proudu a teploty. Telekomunika\u010dn\u00ed sada sod\u00edko-iontov\u00fdch bateri\u00ed je obvykle vybavena syst\u00e9mem BMS, kter\u00fd dok\u00e1\u017ee poskytovat \u00fadaje o stavu nabit\u00ed (SOC), stavu zdrav\u00ed (SOH), v\u00fdstrah\u00e1ch, proudov\u00fdch limitech, teplot\u011b modul\u016f, povolen\u00ed nab\u00edjen\u00ed, stavu vyb\u00edjen\u00ed a ochrann\u00fdch ud\u00e1lostech.<\/p><p class=\"wp-block-paragraph\">Tyto \u00fadaje maj\u00ed hodnotu pouze tehdy, pokud je dok\u00e1\u017ee zpracovat v\u00e1\u0161 regul\u00e1tor usm\u011br\u0148ova\u010de nebo syst\u00e9m monitorov\u00e1n\u00ed za\u0159\u00edzen\u00ed. Samotn\u00fd port CAN nebo RS485 nesta\u010d\u00ed. Regul\u00e1tor mus\u00ed rozum\u011bt protokolu, datov\u00e9 struktu\u0159e, v\u00fdznamu alarm\u016f, proudov\u00fdm limit\u016fm, pravidl\u016fm \u0159\u00edzen\u00ed a postup\u016fm pro p\u0159\u00edpad v\u00fdpadku komunikace.<\/p><p class=\"wp-block-paragraph\">V p\u0159\u00edpad\u011b va\u0161eho za\u0159\u00edzen\u00ed by pojem \u201ekompatibiln\u00ed\u201c m\u011bl znamenat v\u00edc ne\u017e jen fyzick\u00e9 p\u0159ipojen\u00ed. M\u011bli byste v\u011bd\u011bt, zda se baterie nab\u00edj\u00ed, vyb\u00edj\u00ed, pracuje s omezen\u00fdm v\u00fdkonem, vyd\u00e1v\u00e1 v\u00fdstra\u017en\u00fd sign\u00e1l nebo \u010dek\u00e1 na n\u00e1vrat teploty do norm\u00e1lu.<\/p><p class=\"wp-block-paragraph\">P\u0159inejmen\u0161\u00edm ov\u011b\u0159te, zda je mo\u017en\u00e9 p\u0159ij\u00edmat nebo zobrazovat \u00fadaje o stavu SOC, kapacit\u011b, povolen\u00ed nab\u00edjen\u00ed\/vyb\u00edjen\u00ed, teplotn\u00edch alarm\u016f, sn\u00ed\u017een\u00ed proudu, ochrann\u00fdch k\u00f3dech a alarm\u016f s bezpotenci\u00e1lov\u00fdmi kontakty.<\/p><h2 class=\"wp-block-heading\">Teplotn\u00ed kompenzaci je t\u0159eba zkontrolovat, nelze ji br\u00e1t jako samoz\u0159ejmost<\/h2><p class=\"wp-block-paragraph\">Syst\u00e9my nab\u00edjen\u00ed olov\u011bn\u00fdch bateri\u00ed \u010dasto vyu\u017e\u00edvaj\u00ed teplotn\u00ed kompenzaci. Toto chov\u00e1n\u00ed nemus\u00ed b\u00fdt u sod\u00edko-iontov\u00fdch bateri\u00ed stejn\u00e9.<\/p><p class=\"wp-block-paragraph\">V chladn\u00fdch podm\u00ednk\u00e1ch m\u016f\u017ee usm\u011br\u0148ova\u010d ur\u010den\u00fd pro olov\u011bn\u00e9 baterie zv\u00fd\u0161it nab\u00edjec\u00ed nap\u011bt\u00ed. U sod\u00edko-iontov\u00fdch bateri\u00ed m\u016f\u017ee b\u00fdt naopak nutn\u00e9 sn\u00ed\u017eit nab\u00edjec\u00ed proud, zpozdit nab\u00edjen\u00ed nebo pomoc\u00ed syst\u00e9mu BMS zablokovat nab\u00edjen\u00ed p\u0159i teplot\u00e1ch ni\u017e\u0161\u00edch, ne\u017e je povolen\u00e1 nab\u00edjec\u00ed teplota. V hork\u00fdch sk\u0159\u00edn\u00edch m\u016f\u017ee b\u00fdt u bateri\u00ed nam\u00edsto pouh\u00e9 \u00fapravy nap\u011bt\u00ed nutn\u00e9 sn\u00ed\u017eit proud nebo pou\u017e\u00edt tepelnou ochranu.<\/p><p class=\"wp-block-paragraph\">Jedn\u00e1 se o jedno z nej\u010dast\u011bj\u0161\u00edch nedorozum\u011bn\u00ed v projektech t\u00fdkaj\u00edc\u00edch se z\u00e1lo\u017en\u00edch zdroj\u016f pro venkovn\u00ed pou\u017eit\u00ed. Sod\u00edkov\u00e9 baterie sice mohou vykazovat vynikaj\u00edc\u00ed v\u00fdkony p\u0159i vyb\u00edjen\u00ed za n\u00edzk\u00fdch teplot, av\u0161ak schopnost vyb\u00edjen\u00ed za chladu automaticky neznamen\u00e1, \u017ee je mo\u017en\u00e9 je bez omezen\u00ed nab\u00edjet za stejn\u00fdch podm\u00ednek. Bateriov\u00fd modul m\u016f\u017ee sice podporovat vyb\u00edjen\u00ed za n\u00edzk\u00fdch teplot, ale z\u00e1rove\u0148 m\u016f\u017ee omezovat nebo zcela znemo\u017e\u0148ovat nab\u00edjen\u00ed pod hranic\u00ed schv\u00e1len\u00e9ho nab\u00edjec\u00edho rozsahu.<\/p><p class=\"wp-block-paragraph\">U venkovn\u00edch telekomunika\u010dn\u00edch sk\u0159\u00edn\u00ed zohledn\u011bte skute\u010dn\u00fd teplotn\u00ed rozsah v dan\u00e9m m\u00edst\u011b, nikoli pouze \u00fadaje pro celou zemi \u010di region. Teplota ve sk\u0159\u00edni se m\u016f\u017ee li\u0161it v z\u00e1vislosti na nadmo\u0159sk\u00e9 v\u00fd\u0161ce, konstrukci sk\u0159\u00edn\u011b, v\u011btr\u00e1n\u00ed, slune\u010dn\u00edm z\u00e1\u0159en\u00ed a dob\u011b v\u00fdpadk\u016f elektrick\u00e9 s\u00edt\u011b v zimn\u00edm obdob\u00ed.<\/p><h2 class=\"wp-block-heading\">Paraleln\u00ed sod\u00edkov\u00e9 baterie zvy\u0161uj\u00ed slo\u017eitost chov\u00e1n\u00ed usm\u011br\u0148ova\u010de<\/h2><p class=\"wp-block-paragraph\">V telekomunika\u010dn\u00edch sk\u0159\u00edn\u00edch se \u010dasto pou\u017e\u00edv\u00e1 v\u00edce bateriov\u00fdch blok\u016f zapojen\u00fdch paraleln\u011b, aby se prodlou\u017eila doba z\u00e1lohov\u00e1n\u00ed nebo zv\u00fd\u0161ila vyb\u00edjec\u00ed kapacita. To komplikuje kompatibilitu usm\u011br\u0148ova\u010d\u016f.<\/p><p class=\"wp-block-paragraph\">Usm\u011br\u0148ova\u010d m\u016f\u017ee vn\u00edmat bateriovou banku jako jeden celek, zat\u00edmco ka\u017ed\u00fd jednotliv\u00fd blok m\u00e1 vlastn\u00ed syst\u00e9m BMS, nap\u011b\u0165ov\u00e9 limity, teplotn\u00ed stav, stav nabit\u00ed (SOC), proudov\u00fd limit a stav ochrany. Pokud je n\u011bkter\u00fd blok chladn\u011bj\u0161\u00ed, star\u0161\u00ed, m\u00e1 ni\u017e\u0161\u00ed stav nabit\u00ed (SOC) nebo je v re\u017eimu ochrany, m\u016f\u017ee p\u0159ij\u00edmat men\u0161\u00ed nab\u00edjec\u00ed proud. Pokud usm\u011br\u0148ova\u010d nap\u00e1j\u00ed celou banku bez koordinace na \u00farovni jednotliv\u00fdch blok\u016f, m\u016f\u017ee doj\u00edt k nerovnom\u011brn\u00e9mu nab\u00edjen\u00ed.<\/p><p class=\"wp-block-paragraph\">P\u0159i p\u0159id\u00e1v\u00e1n\u00ed dal\u0161\u00edch sod\u00edko-iontov\u00fdch bateriov\u00fdch modul\u016f za \u00fa\u010delem prodlou\u017een\u00ed doby z\u00e1lohy nejde pouze o rozhodnut\u00ed ohledn\u011b kapacity. V\u00e1\u0161 syst\u00e9m m\u016f\u017ee p\u0159ed instalac\u00ed vy\u017eadovat tak\u00e9 synchronizaci stavu nabit\u00ed (SOC), komunikaci na \u00farovni jednotliv\u00fdch modul\u016f, pravidla pro sd\u00edlen\u00ed proudu, koordinaci pojistek \u010di jisti\u010d\u016f, agregaci alarm\u016f a definovanou reakci v p\u0159\u00edpad\u011b odpojen\u00ed jednoho modulu.<\/p><p class=\"wp-block-paragraph\">Usm\u011br\u0148ova\u010d, kter\u00fd pracuje s jedn\u00edm sod\u00edko-iontov\u00fdm akumul\u00e1torem, bude mo\u017en\u00e1 je\u0161t\u011b t\u0159eba prov\u011b\u0159it, ne\u017e bude schopen podporovat n\u011bkolik akumul\u00e1tor\u016f zapojen\u00fdch paraleln\u011b.<\/p><h2 class=\"wp-block-heading\">Skute\u010dn\u00e9 hranice kompatibility<\/h2><p class=\"wp-block-paragraph\">Kompatibilita usm\u011br\u0148ova\u010d\u016f je jasn\u011bj\u0161\u00ed, pokud se p\u0159i v\u00fdb\u011bru n\u00e1hradn\u00edho d\u00edlu vych\u00e1z\u00ed sp\u00ed\u0161e z provozn\u00edho chov\u00e1n\u00ed ne\u017e z udan\u00e9ho nap\u011bt\u00ed.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Hranice<\/th><th>Co se mus\u00ed shodovat<\/th><th>Selh\u00e1n\u00ed, pokud je ignorov\u00e1no<\/th><\/tr><\/thead><tbody><tr><td>Nab\u00edjec\u00ed nap\u011bt\u00ed<\/td><td>Nap\u011bt\u00ed usm\u011br\u0148ova\u010de mus\u00ed odpov\u00eddat rozsahu nap\u011bt\u00ed akumul\u00e1torov\u00e9ho modulu<\/td><td>Nedostate\u010dn\u00e9 nabit\u00ed, ochrana, fale\u0161n\u00e9 poplachy<\/td><\/tr><tr><td>Nab\u00edjec\u00ed proud<\/td><td>Hodnota proudov\u00e9ho omezen\u00ed se mus\u00ed shodovat s p\u0159ijateln\u00fdm rozsahem nab\u00edjen\u00ed akumul\u00e1toru<\/td><td>Pomal\u00e9 nab\u00edjen\u00ed nebo ochrana proti nadm\u011brn\u00e9mu nab\u00edjec\u00edmu proudu syst\u00e9mu BMS<\/td><\/tr><tr><td>LVD<\/td><td>Body odpojen\u00ed se mus\u00ed shodovat s v\u00fdstupn\u00edm oknem<\/td><td>Nevyu\u017eit\u00e1 kapacita nebo nouzov\u00e9 odpojen\u00ed syst\u00e9mu BMS<\/td><\/tr><tr><td>Teplotn\u00ed logika<\/td><td>Urovna\u010d mus\u00ed dodr\u017eovat pravidla pro nab\u00edjen\u00ed za tepla a za studena<\/td><td>Blokov\u00e1n\u00ed p\u0159i studen\u00e9m nabit\u00ed nebo teplotn\u00ed alarmy<\/td><\/tr><tr><td>Komunikace BMS<\/td><td>\u0158\u00eddic\u00ed jednotka mus\u00ed \u010d\u00edst hodnoty limit\u016f, alarmy, stav nabit\u00ed baterie (SOC) a stavy ochrany<\/td><td>Baterie je p\u0159ipojena, ale nen\u00ed vid\u011bt<\/td><\/tr><tr><td>Probuzen\u00ed a zotaven\u00ed<\/td><td>Usm\u011br\u0148ova\u010d mus\u00ed po spu\u0161t\u011bn\u00ed ochrany nebo hlubok\u00e9m vybit\u00ed obnovit stav akumul\u00e1torov\u00e9ho bloku<\/td><td>Ru\u010dn\u00ed z\u00e1sah po v\u00fdpadku<\/td><\/tr><tr><td>Paraleln\u00ed provoz<\/td><td>Syst\u00e9m mus\u00ed zvl\u00e1dat rozd\u00edly na \u00farovni balen\u00ed<\/td><td>Nerovnom\u011brn\u00e9 nab\u00edjen\u00ed, v\u00fdpadky baterie, ztr\u00e1ta kapacity<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">Sod\u00edkov\u00e9 baterie netvo\u0159\u00ed jednu jednotnou kategorii v\u00fdrobk\u016f. Chemick\u00e9 slo\u017een\u00ed \u010dl\u00e1nk\u016f, po\u010det s\u00e9ri\u00ed v bateriov\u00e9m modulu, rozsah nap\u011bt\u00ed, logika syst\u00e9mu BMS, mo\u017enost nab\u00edjen\u00ed p\u0159i n\u00edzk\u00fdch teplot\u00e1ch a komunika\u010dn\u00ed protokol se mohou u jednotliv\u00fdch v\u00fdrobc\u016f li\u0161it. V\u00fdm\u011bna proto mus\u00ed b\u00fdt schvalov\u00e1na pro ka\u017ed\u00fd bateriov\u00fd modul zvl\u00e1\u0161\u0165, nikoli pro jednotliv\u00e9 chemick\u00e9 typy.<\/p><h2 class=\"wp-block-heading\">Standardn\u00ed nastaven\u00ed usm\u011br\u0148ova\u010de funguje pouze v jednoduch\u00fdch p\u0159\u00edpadech<\/h2><p class=\"wp-block-paragraph\">St\u00e1vaj\u00edc\u00ed telekomunika\u010dn\u00ed usm\u011br\u0148ova\u010d m\u016f\u017ee b\u00fdt pou\u017eiteln\u00fd, pokud jej lze nastavit tak, aby spl\u0148oval po\u017eadavky na nap\u011bt\u00ed, proud, teplotu, odpojen\u00ed, alarmy, komunikaci a obnoven\u00ed provozu sod\u00edko-iontov\u00e9ho akumul\u00e1toru.<\/p><p class=\"wp-block-paragraph\">Riziko se zvy\u0161uje, pokud m\u00e1 usm\u011br\u0148ova\u010d pevn\u011b nastaven\u00e9 parametry pro olov\u011bn\u00e9 baterie, omezen\u00e9 mo\u017enosti nastaven\u00ed nap\u011bt\u00ed, aktivn\u00ed vyrovn\u00e1vac\u00ed nebo posilovac\u00ed re\u017eim, nevhodnou teplotn\u00ed kompenzaci, chyb\u011bj\u00edc\u00ed komunika\u010dn\u00ed kan\u00e1l s BMS, nedostate\u010dn\u00e9 mapov\u00e1n\u00ed alarm\u016f nebo neuspokojiv\u00e9 chov\u00e1n\u00ed p\u0159i probuzen\u00ed po spu\u0161t\u011bn\u00ed ochrany baterie.<\/p><p class=\"wp-block-paragraph\">Z pohledu rozhodov\u00e1n\u00ed o projektu lze v\u00fdm\u011bnu obvykle posoudit, pokud jsou nastaven\u00ed usm\u011br\u0148ova\u010de nastaviteln\u00e1, prahov\u00e9 hodnoty LVD jsou jasn\u011b definovan\u00e9, lze omezit nab\u00edjec\u00ed proud a lze na\u010d\u00edst alarmy BMS. Riziko je vysok\u00e9, pokud usm\u011br\u0148ova\u010d podporuje pouze pevn\u00fd profil olov\u011bn\u00fdch bateri\u00ed, data regul\u00e1toru nejsou zn\u00e1ma nebo je n\u011bkolik bateriov\u00fdch blok\u016f zapojeno paraleln\u011b bez SOC a strategie alarm\u016f.<\/p><p class=\"wp-block-paragraph\">N\u00e1hrada za sod\u00edkov\u00e9 baterie by zat\u00edm nem\u011bla b\u00fdt schv\u00e1lena, pokud nelze nastavit nap\u011bt\u00ed usm\u011br\u0148ova\u010de, nelze deaktivovat funkce boost\/equalize, nelze zm\u011bnit prahov\u00e9 hodnoty LVD, nelze na\u010d\u00edst alarmy BMS, nen\u00ed ov\u011b\u0159eno probuzen\u00ed po spu\u0161t\u011bn\u00ed ochrany, je zapojeno v\u00edce bateriov\u00fdch blok\u016f do paraleln\u00edho zapojen\u00ed bez slad\u011bn\u00ed stavu nabit\u00ed (SOC) nebo pokud nem\u016f\u017eete poskytnout \u00fadaje o usm\u011br\u0148ova\u010di a z\u00e1t\u011b\u017ei v dan\u00e9m m\u00edst\u011b.<\/p><h2 class=\"wp-block-heading\">Ov\u011b\u0159te cyklus v\u00fdpadku a dob\u00edjen\u00ed<\/h2><p class=\"wp-block-paragraph\">N\u00e1hrada telekomunika\u010dn\u00edho syst\u00e9mu sod\u00edkov\u00fdmi iontov\u00fdmi bateriemi by nem\u011bla b\u00fdt schv\u00e1lena pouze na z\u00e1klad\u011b toho, \u017ee se usm\u011br\u0148ova\u010d zapne a nap\u011bt\u00ed baterie stoupne. Smyslupln\u00fdm ov\u011b\u0159en\u00edm je skute\u010dn\u00fd pr\u016fb\u011bh z\u00e1lohov\u00e1n\u00ed: pohotovostn\u00ed re\u017eim, v\u00fdpadek s\u00ed\u0165ov\u00e9ho nap\u00e1jen\u00ed, vybit\u00ed na pl\u00e1novanou \u00farove\u0148, chov\u00e1n\u00ed p\u0159i n\u00edzk\u00e9m nap\u011bt\u00ed (LVD), restart usm\u011br\u0148ova\u010de, \u0159\u00edzen\u00ed nab\u00edjec\u00edho proudu, hl\u00e1\u0161en\u00ed alarm\u016f syst\u00e9mem BMS, chov\u00e1n\u00ed paraleln\u00edho zapojen\u00ed bateri\u00ed (je-li pou\u017eito) a n\u00e1vrat do pohotovostn\u00edho re\u017eimu.<\/p><p class=\"wp-block-paragraph\">Praktick\u00e1 zkou\u0161ka na m\u00edst\u011b by m\u011bla zahrnovat:<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Testovac\u00ed krok<\/th><th>Co je t\u0159eba ov\u011b\u0159it<\/th><\/tr><\/thead><tbody><tr><td>Pohotovostn\u00ed re\u017eim<\/td><td>Stabiln\u00ed sb\u011brnice stejnosm\u011brn\u00e9ho proudu, \u017e\u00e1dn\u00e9 fale\u0161n\u00e9 poplachy baterie<\/td><\/tr><tr><td>Porucha klimatizace<\/td><td>Podpora nab\u00edjen\u00ed, vybit\u00ed BMS povoleno<\/td><\/tr><tr><td>Pl\u00e1novan\u00e9 propu\u0161t\u011bn\u00ed<\/td><td>Syst\u00e9m LVD se spust\u00ed d\u0159\u00edve ne\u017e nouzov\u00e9 vypnut\u00ed syst\u00e9mu BMS<\/td><\/tr><tr><td>Regenerace klimatizace<\/td><td>Usm\u011br\u0148ova\u010d se restartuje a znovu se p\u0159ipoj\u00ed norm\u00e1ln\u00edm zp\u016fsobem<\/td><\/tr><tr><td>Dob\u00edt<\/td><td>Hodnoty se pohybuj\u00ed v r\u00e1mci limit\u016f syst\u00e9mu BMS a teplotn\u00edch limit\u016f<\/td><\/tr><tr><td>Komunikace<\/td><td>Zobrazen\u00ed stavu SOC, alarm\u016f, limit\u016f a ochrany<\/td><\/tr><tr><td>Akce s paraleln\u00edmi bal\u00ed\u010dky<\/td><td>Alarm u jednoho bal\u00edku nezp\u016fsob\u00ed selh\u00e1n\u00ed cel\u00e9 banky<\/td><\/tr><tr><td>N\u00e1vrat do pohotovostn\u00edho re\u017eimu<\/td><td>Elektr\u00e1rna dos\u00e1hne rezervy je\u0161t\u011b p\u0159ed dal\u0161\u00edm odstaven\u00edm<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">V p\u0159\u00edpad\u011b nov\u00e9ho projektu lze tuto kontrolu nejprve prov\u00e9st na jednom m\u00edst\u011b nebo v jedn\u00e9 sk\u0159\u00edni, ne\u017e se p\u0159istoup\u00ed k rozs\u00e1hlej\u0161\u00ed v\u00fdm\u011bn\u011b. U st\u00e1vaj\u00edc\u00ed s\u00edt\u011b m\u016f\u017ee stejn\u00fd kontroln\u00ed seznam pomoci odli\u0161it m\u00edsta, kde je modernizace snadn\u00e1, od t\u011bch, kter\u00e1 vy\u017eaduj\u00ed upgrade \u0159\u00eddic\u00edch jednotek nebo d\u016fkladn\u011bj\u0161\u00ed technickou anal\u00fdzu.<\/p><h2 class=\"wp-block-heading\">Z\u00e1v\u011br<\/h2><p class=\"wp-block-paragraph\">Nahrazen\u00ed olov\u011bn\u00fdch bateri\u00ed v telekomunikac\u00edch <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/sodium-ion-battery-manufacturers\/\" target=\"_blank\" rel=\"noreferrer noopener\">sod\u00edkovo-iontov\u00e1 baterie<\/a><\/strong> Bateriov\u00e9 moduly vy\u017eaduj\u00ed p\u0159izp\u016fsoben\u00ed nap\u011bt\u00ed nad 48 V. Usporn\u00fd obvod, nastaven\u00ed LVD, komunikace BMS, teplotn\u00ed logika, chov\u00e1n\u00ed p\u0159i probuzen\u00ed, paraleln\u00ed provoz a obnoven\u00ed po v\u00fdpadku mus\u00ed odpov\u00eddat ov\u011b\u0159en\u00fdm limit\u016fm bateriov\u00e9ho modulu.<\/p><p class=\"wp-block-paragraph\">Ne\u017e v\u00e1m za\u0161leme cenovou nab\u00eddku, sd\u011blte n\u00e1m pros\u00edm model usm\u011br\u0148ova\u010de, model regul\u00e1toru, konfiguraci bateri\u00ed, nastaven\u00ed LVD, zat\u00ed\u017een\u00ed v dan\u00e9m m\u00edst\u011b, teplotn\u00ed rozsah, po\u017eadovanou dobu z\u00e1lohy, po\u010det bateriov\u00fdch blok\u016f a po\u017eadavky na monitorov\u00e1n\u00ed. Pokud si nejste jisti t\u011bmito \u00fadaji, za\u0161lete n\u00e1m fotografie typov\u00e9ho \u0161t\u00edtku usm\u011br\u0148ova\u010de, obrazovky regul\u00e1toru, bateriov\u00e9 sk\u0159\u00edn\u011b a st\u00e1vaj\u00edc\u00edch \u0161t\u00edtk\u016f na bateri\u00edch. <strong><a href=\"https:\/\/www.kmdpower.com\/cs\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\">Kontaktujte n\u00e1s<\/a><\/strong> Na z\u00e1klad\u011b t\u011bchto \u00fadaj\u016f m\u016f\u017ee n\u00e1\u0161 t\u00fdm posoudit, zda je v\u00e1\u0161 st\u00e1vaj\u00edc\u00ed syst\u00e9m stejnosm\u011brn\u00e9ho nap\u00e1jen\u00ed pro telekomunika\u010dn\u00ed za\u0159\u00edzen\u00ed vhodn\u00fd pro nahrazen\u00ed sod\u00edkov\u00fdmi iontov\u00fdmi bateriemi.<\/p><h2 class=\"wp-block-heading\">\u010cASTO KLADEN\u00c9 DOTAZY<\/h2><h3 class=\"wp-block-heading\"><strong>Mohou sod\u00edkov\u00e9 baterie pou\u017e\u00edvat stejn\u00fd telekomunika\u010dn\u00ed usm\u011br\u0148ova\u010d jako olov\u011bn\u00e9 baterie?<\/strong><\/h3><p class=\"wp-block-paragraph\">N\u011bkdy, av\u0161ak pouze v p\u0159\u00edpad\u011b, \u017ee lze usm\u011br\u0148ova\u010d a regul\u00e1tor nastavit tak, aby vyhovovaly po\u017eadavk\u016fm sod\u00edko-iontov\u00e9ho akumul\u00e1toru na nap\u011bt\u00ed, proud, teplotu, LVD, alarmy a obnoven\u00ed. Pouh\u00e1 shoda s jmenovit\u00fdm nap\u011bt\u00edm 48 V je\u0161t\u011b neznamen\u00e1, \u017ee jsou za\u0159\u00edzen\u00ed kompatibiln\u00ed.<\/p><h3 class=\"wp-block-heading\"><strong>Jak\u00e1 nastaven\u00ed usm\u011br\u0148ova\u010de je t\u0159eba zkontrolovat p\u0159ed v\u00fdm\u011bnou bateri\u00ed VRLA za sod\u00edkov\u00e9 iontov\u00e9 baterie?<\/strong><\/h3><p class=\"wp-block-paragraph\">Zkontrolujte nap\u011bt\u00ed v klidov\u00e9m re\u017eimu, chov\u00e1n\u00ed p\u0159i nab\u00edjen\u00ed nebo vyrovn\u00e1v\u00e1n\u00ed, limit nab\u00edjec\u00edho proudu, prahov\u00e9 hodnoty LVD, teplotn\u00ed kompenzaci, mapov\u00e1n\u00ed alarm\u016f, komunikaci BMS a chov\u00e1n\u00ed p\u0159i probuzen\u00ed po spu\u0161t\u011bn\u00ed ochrany nebo hlubok\u00e9m vybit\u00ed.<\/p><h3 class=\"wp-block-heading\"><strong>Pro\u010d m\u016f\u017ee 48V sod\u00edko-iontov\u00e1 baterie v telekomunika\u010dn\u00ed sk\u0159\u00edni p\u0159esto selhat?<\/strong><\/h3><p class=\"wp-block-paragraph\">Je to toti\u017e mo\u017en\u00e9, \u017ee p\u0159\u00ed\u010dinou poruchy nen\u00ed \u0161t\u00edtek na baterii, ale nesoulad se syst\u00e9mem. Star\u00e9 nastaven\u00ed pro olov\u011bn\u00e9 baterie m\u016f\u017ee v\u00e9st k nedostate\u010dn\u00e9mu nabit\u00ed, spu\u0161t\u011bn\u00ed ochrany BMS, nespr\u00e1vn\u00e9mu na\u010dasov\u00e1n\u00ed LVD, nevyd\u00e1n\u00ed v\u00fdstrah, nerovnom\u011brn\u00e9mu paraleln\u00edmu nab\u00edjen\u00ed nebo ne\u00fasp\u011b\u0161n\u00e9mu obnoven\u00ed provozu po v\u00fdpadku.<\/p>","protected":false},"excerpt":{"rendered":"<p>V\u00fdm\u011bna olov\u011bn\u00fdch bateri\u00ed v telekomunika\u010dn\u00edch za\u0159\u00edzen\u00edch za sod\u00edkov\u00e9 bateriov\u00e9 moduly nen\u00ed pouhou v\u00fdm\u011bnou 48V baterie. Jedn\u00e1 se o ot\u00e1zku kompatibility stejnosm\u011brn\u00e9ho nap\u00e1jec\u00edho syst\u00e9mu. Sod\u00edkov\u00fd bateriov\u00fd modul se sice m\u016f\u017ee do sk\u0159\u00edn\u011b vej\u00edt, ale v\u00e1\u0161 st\u00e1vaj\u00edc\u00ed usm\u011br\u0148ova\u010d m\u016f\u017ee st\u00e1le pracovat podle logiky nab\u00edjen\u00ed olov\u011bn\u00fdch bateri\u00ed. Va\u0161e za\u0159\u00edzen\u00ed m\u016f\u017ee proj\u00edt testem zapnut\u00ed, ale selhat p\u0159i skute\u010dn\u00e9m v\u00fdpadku, dob\u00edjen\u00ed, zpracov\u00e1n\u00ed alarm\u016f...<\/p>","protected":false},"author":1,"featured_media":1180,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[19,26],"tags":[],"class_list":["post-5236","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news_catalog","category-product-news"],"_links":{"self":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts\/5236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/comments?post=5236"}],"version-history":[{"count":1,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts\/5236\/revisions"}],"predecessor-version":[{"id":5237,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/posts\/5236\/revisions\/5237"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/media\/1180"}],"wp:attachment":[{"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/media?parent=5236"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/categories?post=5236"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kmdpower.com\/cs\/wp-json\/wp\/v2\/tags?post=5236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}